Search USGSSearch

SEARCH · Search USGS

Results for “Nuclear Instruments and Methods In Physics Research”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

15 recordsLinked to original sources

Graphite sample preparation for AMS in a high pressure and temperature press

A high pressure-temperature press is used to make target material for accelerator mass spectrometry. Graphite was produced from typical **1**4C samples including oxalic acid and carbonates. Beam strength of **1**2C was generally adequate, but random radioactive contamination by **1**4C made age measurements impractical.

Nuclear Instruments and Methods in Physics Researc

Inter-pulse high-resolution gamma-ray spectra using a 14 MeV pulsed neutron generator

A neutron generator pulsed at 100 s-1 was suspended in an artificial borehole containing a 7.7 metric ton mixture of sand, aragonite, magnetite, sulfur, and salt. Two Ge(HP) gamma-ray detectors were used: one in a borehole sonde, and one at the outside wall of the sample tank opposite the neutron generator target. Gamma-ray spectra were collected by the outside detector during each of 10 discrete time windows during the 10 ms period following the onset of gamma-ray build-up after each neutron burst. The sample was measured first when dry and then when saturated with water. In the dry sample, gamma rays due to inelastic neutron scattering, neutron capture, and decay were counted during the first (150 ??s) time window. Subsequently only capture and decay gamma rays were observed. In the wet sample, only neutron capture and decay gamma rays were observed. Neutron capture gamma rays dominated the spectrum during the period from 150 to 400 ??s after the neutron burst in both samples, but decreased with time much more rapidly in the wet sample. A signal-to-noise-ratio (S/N) analysis indicates that optimum conditions for neutron capture analysis occurred in the 350-800 ??s window. A poor S/N in the first 100-150 ??s is due to a large background continuum during the first time interval. Time gating can be used to enhance gamma-ray spectra, depending on the nuclides in the target material and the reactions needed to produce them, and should improve the sensitivity of in situ well logging. ?? 1984.

Nuclear Instruments and Methods In Physics Researc

Radioisotope dilution analyses of geological samples using 236U and 229Th

The use of 236U and 229Th in alpha spectrometric measurements has some advantages over the use of other tracers and measurement techniques in isotope dilution analyses of most geological samples. The advantages are: (1) these isotopes do not occur in terrestrial rocks, (2) they have negligible decay losses because of their long half lives, (3) they cause minimal recoil contamination to surface-barrier detectors, (4) they allow for simultaneous determination of the concentration and isotopic composition of uranium and thorium in a variety of sample types, and (5) they allow for simple and constant corrections for spectral inferences, 0.5% of the 238U activity is subtracted for the contribution of 235U in the 236U peak and 1% of the 229Th activity is subtracted from the 230Th activity. Disadvantages in using 236U and 229Th are: (1) individual separates of uranium and thorium must be prepared as very thin sources for alpha spectrometry, (2) good resolution in the spectrometer system is required for thorium isotopic measurements where measurement times may extend to 300 h, and (3) separate calibrations of the 236U and 229Th spike solution with both uranium and thorium standards are required. The use of these tracers in applications of uranium-series disequilibrium studies has simplified the measurements required for the determination of the isotopic composition of uranium and thorium because of the minimal corrections needed for alpha spectral interferences. ?? 1984.

Nuclear Instruments and Methods In Physics Researc

Synchrotron radiation determination of elemental concentrations in coal

The variations with depth of the elemental concentrations in vitrinites in a series of vitrites have been determined using radiation from the Cornell high energy synchrotron source. All of the vitrites were selected from a single drill core sample of coal from the Emery coalfield, Utah. The results are compared with similar determinations using the Heidelberg proton microprobe. The advantages and disadvantages of the two techniques are discussed. Results are reported for S, Ca, Ti, Fe, Zn, Br, and Sr. For example, it is found that Fe increases from top to bottom of the coal bed in contrast to S, which decreases from top to bottom of the bed. Other features of the two data sets are also described. ?? 1984.

Nuclear Instruments and Methods in Physics Researc

Determination of the occurrence of gold in an unoxidized Carlin-type ore sample using synchrotron radiation

The occurrence of the so-called invisible gold in two unoxidized Carlin-type gold samples from Nevada has been determined using synchrotron X-ray fluorescence (SXRF) analysis at the National Synchrotron Light Source, Brookhaven National Laboratory. A bedded sample from the East ore zone of the Carlin deposit and a breccia sample from Horse Canyon were analyzed. Preliminary results show that gold is found only in the Horse Canyon breccia sample. Experimental details including other X-ray line and diffraction peak interferences, standards used, and minimum detection limits (MDLs) are discussed. Gold, with a MDL range of 0.8 to 3 ppm, was not detected in euhedral pyrite crystals except in the interior porous portion of one grain. Gold was detected in some parts of the matrix. The phase which contains gold has not yet been identified. The highest content of gold so far analyzed is about 40 ppm. There are interesting implications of these new findings. ?? 1987.

Nuclear Instruments and Methods in Physics Researc

The uses of synchrotron radiation sources for elemental and chemical microanalysis

Synchrotron radiation sources offer important features for the analysis of a material. Among these features is the ability to determine both the elemental composition of the material and the chemical state of its elements. For microscopic analysis synchrotron X-ray fluorescence (SXRF) microprobes now offer spatial resolutions of 10 ??m with minimum detection limits in the 1-10 ppm range depending on the nature of the sample and the synchrotron source used. This paper describes the properties of synchrotron radiation and their importance for elemental analysis, existing synchrotron facilities and those under construction that are optimum for SXRF microanalysis, and a number of applications including the high energy excitation of the K lines of heavy elements, microtomography, and XANES and EXAFS spectroscopies. ?? 1990.

Nuclear Instruments and Methods in Physics Researc

36C1 measurements and the hydrology of an acid injection site

In an area in western Tennessee (United States), an industrial firm is injecting acidic (pH = 0.1) iron chloride into permeable zones of carbonate rocks at depths ranging from 1000 to 2200 m below land surface. Overlying the injection zone at a depth of approximately 500 m below land surface is a regional fresh-water aquifer, the Knox aquifer. A study is currently underway to investigate whether the injection wells are hydraulically isolated from the fresh-water aquifer. Drilling of a test well that will reach a total depth of 2700 m has been initiated. The 36Cl content of 15 samples from the Knox aquifer, from monitor wells in the vicinity of the injection site, and from the test well have been analyzed. ?? 1990.

Nuclear Instruments and Methods in Physics Researc

Rare earth element concentrations in geological and synthetic samples using synchrotron X-ray fluorescence analysis

The concentrations of rare earth elements (REEs) in specific mineral grains from the Bayan Obo ore deposit and synthetic high-silica glass samples have been measured by synchrotron X-ray fluorescence (SXRF) analysis using excitation of the REE K lines between 33 and 63 keV. Because SXRF, a nondestructive analytical technique, has much lower minimum detection limits (MDLs) for REEs, it is an important device that extends the in situ analytical capability of electron probe microanalysis (EPMA). The distribution of trace amounts of REEs in common rock-forming minerals, as well as in REE minerals and minerals having minor quantities of REEs, can be analyzed with SXRF. Synchrotron radiation from a bending magnet and a wiggler source at the National Synchrotron Light Source, Brookhaven National Laboratory, was used to excite the REEs. MDLs of 6 ppm (La) to 26 ppm (Lu) for 3600 s in 60-??m-thick standard samples were obtained with a 25-??m diameter wiggler beam. The MDLs for the light REEs were a factor of 10-20 lower than the MDLs obtained with a bending magnet beam. The SXRF REE concentrations in mineral grains greater than 25 ??m compared favorably with measurements using EPMA. Because EPMA offered REE MDLs as low as several hundred ppm, the comparison was limited to the abundant light REEs (La, Ce, Pr, Nd). For trace values of medium and heavy REEs, the SXRF concentrations were in good agreement with measurements using instrumental neutron activation analysis (INAA), a bulk analysis technique. ?? 1993.

Nuclear Instruments and Methods in Physics Researc

Active neutron interrogation experiments and simulation verification using the SIngle-scintillator Neutron and Gamma-Ray spectrometer (SINGR) for geosciences

We present a new SIngle-scintillator Neutron and Gamma Ray spectrometer (SINGR) instrument for use with both passive and active measurement techniques. Here we discuss the application of SINGR for planetary exploration missions, however, hydrology, nuclear non-proliferation, and resource prospecting are all potential areas where the instrument could be applied. SINGR uses an elpasolite scintillator, Cs 2 YLiCl 6 :Ce (CLYC), that has been shown to have high neutron efficiency even at small volumes, with a gamma-ray energy resolution of approximately 4% full-width-at-half-maximum at 662 keV. Active gamma-ray and neutron (GRNS) measurements were performed with SINGR at the NASA Goddard Space Flight Center (GSFC) Goddard Geophysical and Astronomical Observatory (GGAO) outdoor test site using a pulsed neutron generator (PNG) to interrogate geologically relevant materials (basalt and granite monuments). These experimental results, combined with simulations, demonstrate that SINGR is capable of generating neutron die-away curves that can be used to reconstruct the bulk hydrogen abundance and the depth distribution of hydrogen within the monuments. We compare our experimental results with Monte Carlo N-Particle (MCNP) 6.1 transport simulations to constrain the uncertainties in depth and hydrogen abundance from the neutron die-away data generated by SINGR. For future planetary exploration missions, SINGR provides a single detector system for interrogating the shallow subsurface to characterize the presence and abundance of hydrated phases and to provide bulk elemental analysis.

Nuclear Instruments and Methods in Physics Researc

Measurement of in situ-produced cosmogenic nuclides in fine-grained quartz from shale

In situ -produced 10 Be in quartz is widely used to constrain exposure ages and denudation rates, traditionally measured in sand-sized grains. Here we report a new method for isolating fine-grained quartz from shale and demonstrate its reliability for grain sizes down to single microns. Sequential dissolution tests and analyses of grain size separates show that meteoric 10 Be is eliminated and that recoil losses during cosmogenic nuclide production are balanced by implantation from other mineral grains. High-temperature combustion leads to diffusion of meteoric 10 Be into fine-grained quartz and must be used with caution.

Nuclear Instruments and Methods in Physics Researc

Use of chlorine-36 to determine regional-scale aquifer dispersivity, eastern Snake River Plain aquifer, Idaho/USA

Chlorine-36 (36Cl) derived from processed nuclear waste that was disposed at the US Department of Energy's Idaho National Engineering and Environmental Laboratory (INEEL) through a deep injection well in 1958, was detected 24-28 yr later in groundwater monitoring wells approximately 26 km downgradient from the source. Groundwater samples covering the period 1966-1995 were selected from the US Geological Survey's archived-sample library at the INEEL and analyzed for 36Cl by accelerator mass spectrometry (AMS). The smaller 36Cl peak concentrations in water from the far-field monitoring wells relative to the input suggest that aquifer dispersivity may be large. However, the sharpness of the 1958 disposal peak of 36Cl is matched by the measured 36Cl concentrations in water from these wells. This implies that a small aquifer dispersivity may be attributed to preferential groundwater flowpaths. Assuming that tracer arrival times at monitoring wells are controlled by preferential flow, a 1-D system-response model was used to estimate dispersivity by comparing the shape of predicted 36Cl-concentration curves to the shape of 36Cl-concentration curves measured in water from these observation wells. The comparisons suggest that a 1-D dispersivity of 5 m provides the best fit to the tracer data. Previous work using a 2-D equivalent porous-media model concluded that longitudinal dispersivity (equivalent to 1-D dispersivity in our model) was 90 m (Ackerman, 1991). A 90 m dispersivity value eliminates the 1958 disposal peak in our model output curves. The implications of the arrival of 36Cl at downgradient monitoring wells are important for three reasons: (1) the arrival times and associated 36Cl concentrations provide quantitative constraints on residence times, velocities, and dispersivities in the aquifer; (2) they help to refine our working hypotheses of groundwater flow in this aquifer and (3) they may suggest a means of estimating the distribution of preferential flowpaths in the aquifer. ?? 2000 Elsevier Science B.V. All rights reserved.

Nuclear Instruments and Methods in Physics Researc

Chlorine-36 and cesium-137 in ice-core samples from mid-latitude glacial sites in the Northern Hemisphere

Chlorine-36 (36Cl) concentrations, 36Cl/Cl ratios, and 36Cl fluxes in ice-core samples collected from the Upper Fremont Glacier (UFG) in the Wind River Mountain Range, Wyoming, United States and the Nangpai Gosum Glacier (NGG) in the Himalayan Mountains, Nepal, were determined and compared with published results from the Dye-3 ice-core drilling site on the Greenland Ice Sheet. Cesium-137 (137Cs) concentrations in the NGG also were determined. The background fluxes for 36Cl for each glacial site were similar: (1.6??0.3)??10-2 atoms/cm2 s for the UFG samples, (0.7??0.1)??10-2 atoms/cm2 s for the NGG samples, and (0.4??0.1)??10-2 atoms/cm2 s for the Dye-3 samples. The 36Cl fluxes in ice that was deposited as snow during peak atmospheric nuclear weapon test (1957-1958) were (33??1)??10-2 atoms/cm2 s for the UFG site, (291??3)??10-2 atoms/cm2 s for the NGG site, and (124??5)??10-2 atoms/ cm2 s for the Dye-3 site. A weapon test period 137Cs concentration of 0.79??0.05 Bq/kg in the NGG ice core also was detected in the same section of ice that contained the largest 36Cl concentration. ?? 2000 Elsevier Science B.V. All rights reserved.

Nuclear Instruments and Methods in Physics Researc

Environmental 90Sr measurements

90Sr (T1/2 = 28.5 years) is a long-lived radionuclide produced in nuclear fission. Fast radiochemical detection of 90Sr in environmental samples is not feasible using current analytical methods. Accelerator Mass Spectrometry (AMS) measurements of 90Sr were made with the Rehovot 14UD Pelletron accelerator at a terminal voltage of 11 or 12 MV using our standard detection system. Injection of hydride ions (SrH3-) was chosen owing to high beam intensity and low Coulomb explosion effects. 90Sr ions were identified and discriminated from isobaric 90Zr by measuring time of flight, total energy and three independent energy-loss signals in an ionization chamber. A reference sample and a ground-water sample were successfully measured. The detection limit determined for a laboratory blank by the residual counts in the 90Sr region is 90Sr/Sr = 3 ?? 10-13, corresponding in practice to (2-4) ?? 10790Sr atoms or about 0.5-1 pCi/L in environmental water samples.

Nuclear Instruments and Methods in Physics Researc

Quantitative analysis of major elements in silicate minerals and glasses by micro-PIXE

The Guelph micro-PIXE facility has been modified to accommodate a second Si(Li) X-ray detector which records the spectrum due to light major elements (11 ??? Z ??? 20) with no deleterious effects from scattered 3 MeV protons. Spectra have been recorded from 30 well-characterized materials, including a broad range of silicate minerals and both natural and synthetic glasses. Sodium is mobile in some of the glasses, but not in the studied mineral lattices. The mean value of the instrumental constant H for each of the elements Mg, Al, and Si in these materials is systematically 6-8% lower than the H-value measured for the pure metals. Normalization factors are derived which permit the matrix corrections requisite for trace-element measurements in silicates to be based upon pure metal standards for Mg, Al and Si, supplemented by well-established, silicate mineral standards for the elements Na, K and Ca. Rigorous comparisons of electron microprobe and micro-PIXE analyses for the entire, 30-sample suite demonstrate the ability of micro-PIXE to produce accurate analysis for the light major elements in silicates. ?? 1997 Elsevier Science B.V.

Nuclear Instruments and Methods in Physics Researc

Field experiment provides ground truth for surface nuclear magnetic resonance measurement

The need for sustainable management of fresh water resources is one of the great challenges of the 21st century. Since most of the planet's liquid fresh water exists as groundwater, it is essential to develop non-invasive geophysical techniques to characterize groundwater aquifers. A field experiment was conducted in the High Plains Aquifer, central United States, to explore the mechanisms governing the non-invasive Surface NMR (SNMR) technology. We acquired both SNMR data and logging NMR data at a field site, along with lithology information from drill cuttings. This allowed us to directly compare the NMR relaxation parameter measured during logging, T 2 , to the relaxation parameter T 2 * measured using the SNMR method. The latter can be affected by inhomogeneity in the magnetic field, thus obscuring the link between the NMR relaxation parameter and the hydraulic conductivity of the geologic material. When the logging T 2 data were transformed to pseudo- T 2 * data, by accounting for inhomogeneity in the magnetic field and instrument dead time, we found good agreement with T 2 * obtained from the SNMR measurement. These results, combined with the additional information about lithology at the site, allowed us to delineate the physical mechanisms governing the SNMR measurement. Such understanding is a critical step in developing SNMR as a reliable geophysical method for the assessment of groundwater resources.

Geophysical Research Letters