Search USGS⌕ Search

USGS · sir20145176

Evaluation of a mass-balance approach to determine consumptive water use in northeastern Illinois

Abstract

A principal component of evaluating and managing water use is consumptive use. This is the portion of water withdrawn for a particular use, such as residential, which is evaporated, transpired, incorporated into products or crops, consumed by humans or livestock, or otherwise removed from the immediate water environment. The amount of consumptive use may be estimated by a water (mass)-balance approach; however, because of the difficulty of obtaining necessary data, its application typically is restricted to the facility scale. The general governing mass-balance equation is: Consumptive use = Water supplied - Return flows . This study explored a mass-balance field-based computation of consumptive use in a residential setting at the scale of a sanitary sewer service area (sewershed). In addition, the feasibility (cost and difficulty) and relative uncertainties (accuracies) associated with applying the approach at this scale were evaluated. The study was conducted during 2011–13 within a 3.5-square mile (mi 2 ) sewershed confined to a predominantly residential area of Elk Grove Village, Illinois. Following background evaluation of the geohydrologic setting, sewershed infrastructure, and possible components of supplied and returned water, the identified primary components were 1. public water deliveries by the Elk Grove Village Department of Public Works, 2. self-served groundwater withdrawals in an included unincorporated neighborhood with public sanitary sewer service, 3. return flows to the sanitary sewer system, and 4. direct return of water discharged from swimming pools to Salt Creek. Water volumes principally were reported for deliveries, measured for sanitary sewer returns by using an acoustic Doppler current-velocity meter, and estimated for domestic withdrawals and swimming pool discharges to storm sewers. All water volumes required some degree of estimation. Observation wells were installed adjacent to sewer pipelines (lines) to determine the depth of the water table relative to that of the sewer lines and to collect water samples for detection of optical brighteners, as they are routinely discharged as clotheswashing waste to sanitary sewers. These data provided qualitative information on gains (inflow and infiltration) and losses (exfiltration) of sewer flow by pipe leakage, which might otherwise not be considered in the sewer flow return measurements. Hydrographs of sewer flow also were evaluated to identify and estimate storm-associated inputs to sewer flow. The volume of sanitary sewer return flow (778 million gallons per year [Mgal/yr]) was determined to substantially exceed the volume of supplied water (566 Mgal/yr), thus, for this study setting, voiding the utility of the applied mass-balance approach for estimating consumptive water use. Mass-balance components, including sanitary sewer flow and supplied-water use, were estimated within reasonable limits of uncertainty. Evidence of a water table that is typically shallower than the area’s sewer lines, yet is sometimes depressed near more deeply buried sewer lines, suggests groundwater infiltration into the sewers contributes to the excess volume of return flow. Technical obstacles and project resources precluded accurate quantification of infiltration volumes and other gains and losses to sanitary sewer flow. As estimated from various simplified methods, a minimum of 26 percent of return flow measured in the sanitary sewer represented groundwater infiltration and stormwater inflow; separately, about 2 percent of return flow was estimated as inflow. On the basis of the alternative winter base-rate method, consumptive use in the sewershed was estimated as 13 percent, which compares favorably with that used by the State of Illinois for Lake Michigan allocation accounting (10 percent) and other States and Canadian Provinces in the Great Lakes region (generally 10-15 percent). The study also provided other findings considered useful to studies of water use and to performance evaluation of sanitary sewer infrastructure. In urban residential settings, the comparatively small volumes of nonpublic sources of water (self-supplied) and direct (nonsanitary) return flow potentially can be ignored in the estimation of consumptive use. An acoustic Doppler current-velocity meter can be used in sanitary sewers to accurately measure discharge and reasonably estimate storm-associated inflows. Hourly to daily patterns of water use can be readily identified and quantified in the return flow record for the sanitary sewers. Relative volumes of infiltration gains (and exfiltration losses) can be substantial, even in sewer systems of communities making significant investments in system upgrades to limit sewer line leakage. Monitoring of optical brighteners in groundwater (and potentially in sanitary sewer flow) can provide a useful means of identifying probable leakage from (and to) sewer lines. Accurate quantification of gains and losses to sanitary sewer flow at the sewershed scale will require additional research effort and technical advances. Under ideal conditions, accurate quantification of consumptive use at the sewershed scale by the described mass-balance approach might be possible. Under most prevailing conditions, quantification likely would be more costly and time consuming than that of the present study, given the freely contributed technical support of the host community and relatively appropriate conditions of the study area. Essentials to quantification of consumptive use are a fully cooperative community, storm and sanitary sewers that are separate, and newer sewer infrastructure and (or) a robust program for limiting infiltration, exfiltration, and inflow.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P.C. Mills, James J. Duncker, Thomas M. Over, Marian Domanski, Frank L. Engel. 2014. Evaluation of a mass-balance approach to determine consumptive water use in northeastern Illinois. https://doi.org/10.3133/sir20145176

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗