Search USGS⌕ Search

USGS · sir20055063

Variability of differences between two approaches for determining ground-water discharge and pumpage, including effects of time trends, Lower Arkansas River Basin, southeastern Colorado, 1998-2002

Abstract

In the mid-1990s, the Colorado Division of Water Resources (CDWR) adopted rules governing measurement of tributary ground-water pumpage for the Arkansas River Basin. The rules allowed ground-water pumpage to be determined using one of two approaches?power conversion coefficient (PCC) or totalizing flowmeters (TFM). In addition, the rules allowed a PCC to be applied to the electrical power usage up to 4 years in the future to estimate ground-water pumpage. As a result of concerns about potential errors in applying the PCC approach forward in time, a study was done by the U.S. Geological Survey, in cooperation with CDWR and Colorado Water Conservation Board, to evaluate the variability in differences in pumpage between the two approaches, including the effects of time trends. This report compared measured ground-water pumpage using TFMs to computed ground-water pumpage using PCCs by developing statistical models of relations between explanatory variables, such as site, time, and pumping water level, and dependent variables, which are based on discharge, PCC, and pumpage. When differences in pumpage (diffP) were computed using PCC measurements and power consumption for the same year (1998-2002), the median diffP, depending on the year, ranged from +0.1 to -2.9 percent; the median diffP for the entire period was -1.5 percent. However, when diffP was computed using PCC measurements applied to the next year's power consumption, the median diffP was -0.3 percent; and when PCC measurements were applied 2, 3, or 4 years into the future, median diffPs were +1.8 percent for a 2-year forward lag and +5.3 percent for a 4-year forward lag, indicating that pumpage computed with the PCC approach, as generally applied under the ground-water pumpage measurement rules by CDWR, tended to overestimate pumpage as compared to pumpage using TFMs when PCC measurement was applied to future years of measured power consumption. Analyses were done to better understand the causes of the time trend; an estimate of the overall trend with time (uncorrected for pumping water-level changes) yielded a trend of about 2.2 percent per lag year for diffP. A separate analysis that incorporated a surface-water diversion term in the statistical model rendered the time-trend term insignificant, indicating that the time trend in the models served as a surrogate for other variables, some of which reflect underlying hydrologic conditions. A more precise explanation of the potential causes of the time trend was not obtained with the available data. However, the model results with the surface-water diversion term indicate that much of the trend of 2.2 percent per lag year in diffP resulted from applying a PCC to estimate pumpage under hydrologic conditions different from those under which the PCC was measured. Although there is no evidence to conclude that the upward time trend determined in the data for this 5-year period would hold in the future, historical static ground-water levels in the study area generally have exhibited small variations over multidecadal time scales. Therefore, the approximately 2 percent per lag year trend determined in these data is expected to be a reasonable guideline for estimating potential errors in the PCC approach resulting from temporally varying hydrologic conditions between time of PCC measurement and pumpage estimation. Comparisons also were made between total, or aggregated, pumpage for a network of wells as computed by the PCC approach and the TFM approach. For 100 wells and a lag of 4 years between PCC measurement and pumpage estimation, there was a 95-percent probability that the difference between total network pumpage measured by the PCC approach and that measured using a TFM would be between 5.2 and 14.4 percent. These estimates were based on a bias of 2.2 percent per lag year estimated for the period 1998-2002 during which hydrologic conditions were known to have changed. Using the same assumptions, the estimated d

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Brent M. Troutman, Patrick Edelmann, Russell G. Dash. 2005. Variability of differences between two approaches for determining ground-water discharge and pumpage, including effects of time trends, Lower Arkansas River Basin, southeastern Colorado, 1998-2002. https://doi.org/10.3133/sir20055063

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗