Search USGS⌕ Search

Geology topics

Russell G. Dash

Publications and source records attributed to Russell G. Dash.

3 recordsLinked to original sources

Variability of differences between two approaches for determining ground-water discharge and pumpage, including effects of time trends, Lower Arkansas River Basin, southeastern Colorado, 1998-2002

In the mid-1990s, the Colorado Division of Water Resources (CDWR) adopted rules governing measurement of tributary ground-water pumpage for the Arkansas River Basin. The rules allowed ground-water pumpage to be determined using one of two approaches?power conversion coefficient (PCC) or totalizing flowmeters (TFM). In addition, the rules allowed a PCC to be applied to the electrical power usage up to 4 years in the future to estimate ground-water pumpage. As a result of concerns about potential errors in applying the PCC approach forward in time, a study was done by the U.S. Geological Survey, in cooperation with CDWR and Colorado Water Conservation Board, to evaluate the variability in differences in pumpage between the two approaches, including the effects of time trends. This report compared measured ground-water pumpage using TFMs to computed ground-water pumpage using PCCs by developing statistical models of relations between explanatory variables, such as site, time, and pumping water level, and dependent variables, which are based on discharge, PCC, and pumpage. When differences in pumpage (diffP) were computed using PCC measurements and power consumption for the same year (1998-2002), the median diffP, depending on the year, ranged from +0.1 to -2.9 percent; the median diffP for the entire period was -1.5 percent. However, when diffP was computed using PCC measurements applied to the next year's power consumption, the median diffP was -0.3 percent; and when PCC measurements were applied 2, 3, or 4 years into the future, median diffPs were +1.8 percent for a 2-year forward lag and +5.3 percent for a 4-year forward lag, indicating that pumpage computed with the PCC approach, as generally applied under the ground-water pumpage measurement rules by CDWR, tended to overestimate pumpage as compared to pumpage using TFMs when PCC measurement was applied to future years of measured power consumption. Analyses were done to better understand the causes of the time trend; an estimate of the overall trend with time (uncorrected for pumping water-level changes) yielded a trend of about 2.2 percent per lag year for diffP. A separate analysis that incorporated a surface-water diversion term in the statistical model rendered the time-trend term insignificant, indicating that the time trend in the models served as a surrogate for other variables, some of which reflect underlying hydrologic conditions. A more precise explanation of the potential causes of the time trend was not obtained with the available data. However, the model results with the surface-water diversion term indicate that much of the trend of 2.2 percent per lag year in diffP resulted from applying a PCC to estimate pumpage under hydrologic conditions different from those under which the PCC was measured. Although there is no evidence to conclude that the upward time trend determined in the data for this 5-year period would hold in the future, historical static ground-water levels in the study area generally have exhibited small variations over multidecadal time scales. Therefore, the approximately 2 percent per lag year trend determined in these data is expected to be a reasonable guideline for estimating potential errors in the PCC approach resulting from temporally varying hydrologic conditions between time of PCC measurement and pumpage estimation. Comparisons also were made between total, or aggregated, pumpage for a network of wells as computed by the PCC approach and the TFM approach. For 100 wells and a lag of 4 years between PCC measurement and pumpage estimation, there was a 95-percent probability that the difference between total network pumpage measured by the PCC approach and that measured using a TFM would be between 5.2 and 14.4 percent. These estimates were based on a bias of 2.2 percent per lag year estimated for the period 1998-2002 during which hydrologic conditions were known to have changed. Using the same assumptions, the estimated d

Scientific Investigations Report↗

Comparison of two approaches for determining ground-water discharge and pumpage in the lower Arkansas River Basin, Colorado, 1997-98

In March 1994, the Colorado Division of Water Resources (CDWR) adopted “Rules Governing the Measurement of Tributary Ground Water Diversions Located in the Arkansas River Basin” (Office of the State Engineer, 1994); these initial rules were amended in February 1996 (Office of the State Engineer, 1996). The amended rules require users of wells that divert tributary ground water to annually report the water pumped monthly by each well. The rules allow a well owner to report the pumpage measured by a totalizing flowmeter (TFM) or pumpage determined from electrical power data and a power conversion coefficient (PCC) (Hurr and Litke, 1989). Opinions by representatives of the State of Kansas, presented before the Special Master hearing a court case [State of Kansas v. State of Colorado, No. 105 Original (1996)] concerning post-Compact well pumping, stated that the PCC approach does not provide the same level of accuracy and reliability as a TFM when used to determine pumpage. In 1997, the U.S. Geological Survey (USGS), in cooperation with the CDWR, began a 2-year study to compare ground-water pumpage estimates made using the TFM and the PCC approaches. The study area was along the Arkansas River between Pueblo, Colorado, and the Colorado-Kansas State line (fig. 1). The two approaches for estimating ground-water discharge and pumpage were compared for more than 100 wells completed in the alluvial aquifer of the Arkansas River Basin. The TFM approach uses an inline flowmeter to directly measure instantaneous discharge and the total volume of water pumped at a well. The PCC approach uses electrical power consumption records and a power conversion coefficient to estimate the pumpage at ground-water wells. This executive summary describes the results of the comparison of the two approaches. Specifically, (1) the differences in instantaneous discharge measured with three portable flowmeters and measured with an inline TFM are evaluated, and the statistical differences in paired instantaneous discharge between the two approaches are determined; (2) short- and long-term variations in the PCC’s are presented; (3) differences in pumpage between the two approaches are evaluated, and the statistical differences in pumpage between the two approaches are determined; (4) potential sources of discrepancy between pumpage estimates are discussed; and (5) differences in total network pumpage using the two approaches are presented. During the irrigation seasons of 1997 and 1998, instantaneous discharge and electrical power demand were measured at randomly selected wells to determine PCC’s. At more than 100 wells, the PCC’s determined during the 1998 season were applied to total electrical power consumption data that was recorded between the initial and final readings at each network well site in 1998 to estimate total ground-water pumpage. At each site, an inline TFM was installed in a full-flowing, acceptable test section of pipe on the discharge side of the pump where the measurement of discharge was made. Measurements of instantaneous ground-water discharge also were made using three different types of portable flowmeters. The average velocity multiplied by the cross-sectional area of the discharge pipe was used to compute the discharge in gallons per minute. Whenever possible, discharge measurements were made at each network site using all three types of portable flowmeters.

Colorado↗

Water-quality data for the Arkansas River Basin, southeastern Colorado, 1990-93

Water-quality data were collected and compiled for 59 surface-water stations in the Arkansas River Basin of Colorado. The purpose of the data collection was to describe selected water-quality characteristics of the Arkansas River from the headwaters downstream to the Colorado-Kansas State line. Data are presented for 19 Arkansas River stations, 31 tributary stations, 2 mine-drainage stations, and 7 transmountain diversion stations. Water-quality data presented in this report include instantaneous discharge; onsite measurements of specific conductance, pH, water temperature, and dissolved oxygen; analytical concentrations of bacteria, dissolved solids, major nutrients, trace elements, pesticides, radiochemicals, and suspended sediment; and quality-assurance data for selected water-quality constituents. Sampling began in April 1990 and continued through March 1993 at the 59 surface-water stations. The basinwide water-quality study was initiated in 1988 by the U.S. Geological Survey in cooperation with 14 local agencies and the Bureau of Reclamation.

Colorado↗