Death Valley regional groundwater flow system, Nevada and California: Hydrogeologic framework and transient groundwater flow model

Abstract

A numerical three-dimensional (3D) transient groundwater flow model of the Death Valley region was developed by the U.S. Geological Survey for the U.S. Department of Energy programs at the Nevada Test Site and at Yucca Mountain, Nevada. Decades of study of aspects of the groundwater flow system and previous less extensive groundwater flow models were incorporated and reevaluated together with new data to provide greater detail for the complex, digital model. A 3D digital hydrogeologic framework model (HFM) was developed from digital elevation models, geologic maps, borehole information, geologic and hydrogeologic cross sections, and other 3D models to represent the geometry of the hydrogeologic units (HGUs). Structural features, such as faults and fractures, that affect groundwater flow also were added. The HFM represents Precambrian and Paleozoic crystalline and sedimentary rocks, Mesozoic sedimentary rocks, Mesozoic to Cenozoic intrusive rocks, Cenozoic volcanic tuffs and lavas, and late Cenozoic sedimentary deposits of the Death Valley regional groundwater flow system (DVRFS) region in 27 HGUs. Information from a series of investigations was compiled to conceptualize and quantify hydrologic components of the groundwater flow system within the DVRFS model domain and to provide hydraulic-property and head-observation data used in the calibration of the transient-flow model. These studies reevaluated natural groundwater discharge occurring through evapotranspiration (ET) and spring flow; the history of groundwater pumping from 1913 through 1998; groundwater recharge simulated as net infiltration; model boundary inflows and outflows based on regional hydraulic gradients and water budgets of surrounding areas; hydraulic conductivity and its relation to depth; and water levels appropriate for regional simulation of prepumped and pumped conditions within the DVRFS model domain. Simulation results appropriate for the regional extent and scale of the model were provided by acquiring additional data, by reevaluating existing data using current technology and concepts, and by refining earlier interpretations to reflect the current understanding of the regional groundwater flow system. Groundwater flow in the Death Valley region is composed of several interconnected, complex groundwater flow systems. Groundwater flow occurs in three subregions in relatively shallow and localized flow paths that are superimposed on deeper, regional flow paths. Regional groundwater flow is predominantly through a thick Paleozoic carbonate rock sequence affected by complex geologic structures from regional faulting and fracturing that can enhance or impede flow. Spring flow and ET are the dominant natural groundwater discharge processes. Groundwater also is withdrawn for agricultural, commercial, and domestic uses. Groundwater flow in the DVRFS was simulated using MODFLOW-2000, the U.S. Geological Survey 3D finitedifference modular groundwater flow modeling code that incorporates a nonlinear least-squares regression technique to estimate aquifer parameters. The DVRFS model has 16 layers of defined thickness, a finite-difference grid consisting of 194 rows and 160 columns, and uniform cells 1,500 meters (m) on each side. Prepumping conditions (before 1913) were used as the initial conditions for the transient-state calibration. The model uses annual stress periods with discrete recharge and discharge components. Recharge occurs mostly from infiltration of precipitation and runoff on high mountain ranges and from a small amount of underflow from adjacent basins. Discharge occurs primarily through ET and spring discharge (both simulated as drains) and water withdrawal by pumping and, to a lesser amount, by underflow to adjacent basins simulated by constant-head boundaries. All parameter values estimated by the regression are reasonable and within the range of expected values. The simulated hydraulic heads of the final calibrated transient model generally fit observed heads reasonably well (residuals with absolute values less than 10 meters) with two exceptions: in most areas of nearly flat hydraulic gradient the fit is considered moderate (residuals with absolute values of 10 to 20 meters), and in areas of steep hydraulic gradient along the Eleana Range and western part of Yucca Flat, southern part of the Owlshead Mountains, southern part of the Bullfrog Hills, and the north-northwestern part of the model domain (residuals with absolute values greater than 20 meters). Groundwater discharge residuals are fairly random, with as many areas where simulated flows are less than observed flows as areas where simulated flows are greater. The highest unweighted groundwater discharge residuals occur at Death Valley, Sarcobatus Flat (northeastern area), Tecopa, and early observations at Manse Spring in Pahrump Valley. High weighted-discharge residuals were computed in Indian Springs Valley and parts of Death Valley. Most of these inaccuracies in head and discharge can be attributed to insufficient representation of the hydrogeology in the HFM and(or) discharge estimates, misrepresentation of water levels, and(or) model error associated with grid-cell size. The model represents the large and complex groundwater flow system of the Death Valley region at a greater degree of refinement and accuracy than has been possible previously. The representation of detail provided by the 3D digital hydrogeologic framework model and the numerical groundwater flow model enabled greater spatial accuracy in every model parameter. The lithostratigraphy and structural effects of the hydrogeologic framework; recharge estimates from simulated net infiltration; discharge estimates from ET, spring flow, and pumping; and boundary inflow and outflow estimates all were reevaluated, some additional data were collected, and accuracy was improved. Uncertainty in the results of the flow model simulations can be reduced by improving on the quality, interpretation, and representation of the water-level and discharge observations used to calibrate the model and improving on the representation of the HGU geometries, the spatial variability of HGU material properties, the flow model physical framework, and the hydrologic conditions.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 35.5° to 38.1117° latitude; -117.7° to -115° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wayne Belcher, Frank A. D’Agnese, Grady M. O’Brien, Donald S. Sweetkind, Carma A. San Juan, Randell J. Laczniak, Christopher J. Potter, Heather Putnam, Claudia C. Faunt, Joan B. Blainey, Mary C. Hill, M. S. Bedinger, J. R. Harrill. 2010. Death Valley regional groundwater flow system, Nevada and California: Hydrogeologic framework and transient groundwater flow model. https://doi.org/10.3133/pp1711

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Resurvey of the Marble Canyon and Bridge Canyon dam sites in Grand Canyon National Park—Changes in sediment storage and evidence supporting the occurrence of bedrock incision through the mid-20th century

The Bureau of Reclamation developed an extensive plan for a network of dams, water tunnels, and hydropower plants in and around Grand Canyon, Arizona, in the 1940s through 1960s. The two largest of these planned dams were the Marble Canyon and Bridge Canyon Dams on the Colorado River. Though these dams were ultimately never built, Reclamation conducted extensive topographic, bathymetric, and subsurface exploration work at the sites proposed for these dams in the 1940s and 1950s. Resurveys of these dam sites were conducted between 1998 and 2021 to determine the changes in sediment storage at these dam sites caused by the upstream construction and operation of Glen Canyon Dam and by the recession of Lake Mead, the reservoir impounded by Hoover Dam. The resurveys of the Marble Canyon dam sites indicate that the post-1950s changes in sediment storage at these dam sites are broadly consistent with flux-based estimates of voluminous sand erosion from Marble Canyon since the 1963 closure of Glen Canyon Dam. These resurveys also suggest that the pre-dam longitudinal variation in sediment thickness over bedrock played a key role in determining the locations of the sand erosion induced by Glen Canyon Dam; more sand eroded from locations where more sand was present in the 1950s. The resurvey of the Bridge Canyon dam sites indicates that the Colorado River’s incision of the Lake Mead delta is regulated both by bed-sediment grain size and downstream hydraulic controls. Finally, analyses of bed-sediment thickness and sedimentological data at the dam sites, and observations of bed scour and gravel transport, suggest that sufficient bedrock was exposed to allow bedrock incision during commonly recurring pre-dam snowmelt floods that entrained small boulders into transport.

Arizona

The eruptive behavior of distributed volcanism forming low shield edifices—A case study of Sentinel-Arlington volcanic field, U.S.A.

Distributed volcanic fields are present in various tectonic settings worldwide, and their characteristics reflect differing influences from magmatic and tectonic processes. In the southwestern United States alone, there are 37 Quaternary distributed volcanic fields. After the primary period of extensional tectonics in the southern Basin and Range 15–5 million years ago, the Sentinel-Arlington volcanic field developed in southwestern Arizona between 4 and 1 million years ago. The Sentinel-Arlington volcanic field consists primarily of low relief shield volcanoes, a type of distributed volcanism with poorly understood temporal evolution. The Sentinel-Arlington volcanic field is less than 200 kilometers (km) from the Colorado Plateau, Gulf of California, and southern San Andreas Fault system. This work identifies and examines controls on the emplacement of the Sentinel-Arlington volcanic field by documenting shallow and surficial structures as well as eruption characteristics and style through time. The Sentinel-Arlington volcanic field consists of 21 volcanoes with a total of 33 vents over an area of about 770 square kilometers (km 2 ). The prominence of low relief shield volcanoes may be explained by ascent of basaltic magmas through thin Basin and Range crust, without much crustal contamination, and low viscosities common to mafic compositions. Typical eruption characteristics involve the construction of low relief shield volcanoes followed by Strombolian fissure eruptions at the summits or near-summit medial areas that produce scoria lapilli, which may weld to form agglomerate. The total lifetime erupted volume of about 4.3 cubic kilometers (km 3 ) represents an average eruptive flux of approximately 2x10 -3 km 3 per thousand years (k.y.). This erupted volume is low relative to Neogene basaltic intraplate distributed volcanic fields worldwide, which typically range from 10 -3 to 1 km 3 k.y. -1 . Sentinel-Arlington volcanic field eruptions were likely triggered by intermittent rejuvenation of transient magmatic zones that exist in thinned crust. Instantaneous flux from point sources feeding the lava flows is estimated to be on the order of 10 -1 to 10 cubic meters per second.

Arizona

Capitalization of positional (Lower/Middle/Upper) and temporal (Early/Middle/Late) adjectives in the names of formal chronostratigraphic and geochronologic units of the Phanerozoic

Many authors are understandably confused about the capitalization of the words “lower,” “middle,” “upper,” “early,” and “late.” Where these words are used simply as descriptive adjectives, they should be in lowercase; where they form the first word of a formal chronostratigraphic or geochronologic unit name, they should be in uppercase.

Professional Paper