Search USGSSearch

USGS · 70034361

Loss of volatile hydrocarbons from an LNAPL oil source

Abstract

The light nonaqueous phase liquid (LNAPL) oil pool in an aquifer that resulted from a pipeline spill near Bemidji, Minnesota, was analyzed for volatile hydrocarbons (VHCs) to determine if the composition of the oil remains constant over time. Oil samples were obtained from wells at five locations in the oil pool in an anaerobic part of the glacial outwash aquifer. Samples covering a 21-year period were analyzed for 25 VHCs. Compared to the composition of oil from the pipeline source, VHCs identified in oil from wells sampled in 2008 were 13 to 64% depleted. The magnitude of loss for the VHCs analyzed was toluene ≫ o-xylene, benzene, C 6 and C 10–12 n-alkanes > C 7 –C 9 n-alkanes > m-xylene, cyclohexane, and 1- and 2-methylnaphthalene > 1,2,4-trimethylbenzene and ethylbenzene. Other VHCs including p-xylene, 1,3,5- and 1,2,3-trimethylbenzenes, the tetramethylbenzenes, methyl- and ethyl-cyclohexane, and naphthalene were not depleted during the time of the study. Water–oil and air–water batch equilibration simulations indicate that volatilization and biodegradation is most important for the C 6 –C 9 n-alkanes and cyclohexanes; dissolution and biodegradation is important for most of the other hydrocarbons. Depletion of the hydrocarbons in the oil pool is controlled by: the lack of oxygen and nutrients, differing rates of recharge, and the spatial distribution of oil in the aquifer. The mass loss of these VHCs in the 5 wells is between 1.6 and 7.4% in 29 years or an average annual loss of 0.06–0.26%/year. The present study shows that the composition of LNAPL changes over time and that these changes are spatially variable. This highlights the importance of characterizing the temporal and spatial variabilities of the source term in solute-transport models.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 47.3762° to 47.6177° latitude; -95.0373° to -94.6844° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mary Jo Baedecker, Robert P. Eganhouse, Barbara A. Bekins, Geoffrey N. Delin. 2011. Loss of volatile hydrocarbons from an LNAPL oil source. https://doi.org/10.1016/j.jconhyd.2011.06.006

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Distinguishing natural from mining-related metal sources by including streambank groundwater data in a stream mass loading study

Distinguishing stream metal loading caused by mine features from that caused by natural background sources remains challenging, yet this distinction is essential for making effective remedial decisions at many legacy mine sites. We combine a stream tracer injection and synoptic sampling study with data from shallow near-stream groundwater wells to estimate left-bank versus right-bank metal loading contributions at the 100-m spatial scale. The study was performed in the East Mancos River, a mountain headwater stream in Colorado, USA. The dominant source of elevated stream metal concentrations could be either groundwater infiltration through right-bank Doyle Mine waste piles or natural acid rock drainage from hydrothermally altered bedrock located mainly on the left bank. For the five metals of concern (Cu, Al, Zn, Cd, and Mn), we find that 15 % of the load contributed by diffuse groundwater inputs in the section potentially influenced by Doyle mine waste originates from the right bank. This right-bank potential mine contribution equates to only 3 % of the total watershed instream load for these metals. Furthermore, apparent 3 H/ 3 He groundwater ages in segments contributing most of the right-bank metal loading are sufficiently old (9–12 yr) to suggest that infiltration through the waste piles, located only 140–180 m from the stream, is unlikely. Estimated potential Doyle mine loading contributions can therefore be considered maximum values. Study results thus indicate that Doyle mine waste piles are a minor source of metal loading under low-flow conditions, and streambank groundwater data can provide valuable additional information in stream mass loading studies.

Colorado

Per- and polyfluoroalkyl substances (PFAS) mass flux and mass balance at an aqueous film-forming foam release site in semiarid eastern New Mexico, USA

Passive flux meters (PFMs) directly measure groundwater chemistry mass flux and Darcy flux, providing insight into contaminant source-zone architecture and transport properties. This study uses PFMs to characterize PFAS flux in groundwater at a semiarid site with a thick (greater than 90-m) unsaturated zone where groundwater has been contaminated with per - and polyfluoroalkyl substances (PFAS) related to the use of aqueous film-forming foam (AFFF) for fire training and fire suppression. PFAS mass discharge (PFAS mass flux integrated over a control plane) in groundwater downgradient from several PFAS release areas is calculated using PFM results. In groundwater downgradient from fire-training areas, total PFAS mass discharge (summed across 14 compounds) was estimated to be between 6.0 and 31 g per day in 2020 and between 5.9 and 23 g per day in 2021. Site-specific documentation, generic information on AFFF properties, and literature values of PFAS concentration in AFFF are used to estimate site-specific PFAS-application rates at fire-training areas. These PFAS-application rates are compared to groundwater PFAS-discharge rates. Results suggest that transformation processes (exact pathways unknown) have led to increased discharge of measured PFAS in groundwater relative to initial AFFF formulations. The mass balance approach has broad applicability as a high-level approach that can provide insight into PFAS transport at AFFF sites.

New Mexico

Concentration-discharge relations and transient metal loads reveal spatiotemporal variability in solute-generation mechanisms in a mine-affected watershed

Concentration-discharge (CQ) relations are commonly used to understand geochemical and hydrologic controls on the generation of solutes in watersheds. Despite the widespread application of CQ relations, this technique has been infrequently applied to acid mine drainage (AMD) sites, but the CQ framework may allow mechanistic understanding of remedial outcomes such as impoundment of water within underground mines. Results of CQ analyses and changes in metal loads in an AMD affected watershed in Colorado, USA indicate that dissolved loads increased at many individual locations following water impoundment within mine workings. Although increased loads were observed at most individual locations, these increases were offset by a large decrease in loading from the largest mine. A loading analysis that included data from an instream monitoring location showed a statistically significant decrease in Fe and Zn after bulkhead emplacement, indicating a net positive effect of bulkheads. Streams generally displayed dilution CQ patterns whereas mines and springs showed either flushing or chemostatic patterns prior to bulkheading, which transitioned to chemostatic patterns following bulkheading, indicating a transition from dynamic to equilibrium geochemical processes. Saturation indices for sulfide and secondary minerals indicated that mines and springs were near equilibrium for phases including schwertmannite, fluorite, and gypsum. Saturation indices vary through time for mines suggesting progressive leaching of sulfide minerals as the mass of available minerals in the mine workings decreases. Together, these diverse analyses provide an integrated understanding of the variability in solute generating processes in this watershed and may inform remediation plans for similarly affected sites by indicating the nature of mineralogic controls on water quality.

Colorado