Search USGS⌕ Search

Geology topics

Research about Pennsylvania

Source-linked reports with geographic coverage including Pennsylvania.

At least 289 records · Page 16Linked to original sources

Relations among pH, sulfate, and metals concentrations in anthracite and bituminous coal-mine discharges, Pennsylvania

Water-quality data for discharges from 140 abandoned mines in the Bituminous and Anthracite Coalfields of Pennsylvania illustrate relations among pH, sulfate, and dissolved metal concentrations. The pH for the 140 samples ranged from 2.7 to 7.3, with two modes at pH 2.5 to 4 (acidic) and 6 to 7 (near neutral). Generally, flow rates were smaller and solute concentrations were greater for low-pH samples; flow rates increased with pH. Although the pH distribution was similar for the bituminous and anthracite subsets, the bituminous discharges had smaller median flow rates, greater concentrations of sulfate, iron, and aluminum, and smaller concentrations of barium and lead than anthracite discharges with the same pH values. The observed relations between the pH and constituent concentrations can be attributed to (1) dilution of acidic water by alkaline ground water; (2) solubility control of aluminum, iron, manganese, barium, and lead by hydroxide, sulfate, and/or carbonate minerals; and (3) aqueous sulfate-complex formation. The formation of AlSO 4 + and AlHSO 4 +2 complexes adds to the total dissolved aluminum concentration at pH of equilibrium with aluminum hydroxide or hydroxysulfate minerals and can account for 10 to 20 times greater concentrations of dissolved aluminum in bituminous discharges compared to anthracite discharges at similar pH. Sulfate complexation also can account for 10 to 30 times greater concentrations of dissolved ferric iron concentrations at equilibrium with ferrihydrite (Fe(OH) 3 ) and/or schwertmannite (Fe 8 O 8 (OH) 4.5 (SO 4 ) 1.75 ) at pH of 3 to 5. In contrast, lower barium and lead concentrations in bituminous than anthracite discharges indicates elevated sulfate concentration could decrease mobility of these metals by the formation of insoluble minerals such as barite (BaSO 4 ) or anglesite (PbSO 4 ). Most samples were saturated with barite, but none were saturated with anglesite. Hence, lead concentrations could be controlled by coprecipitation with barite and/or by adsorption to schwertmannite or another sulfate-bearing oxide.

Pennsylvania↗

Influence of fracture anisotropy on ground water ages and chemistry, Valley and Ridge province, Pennsylvania

Model ground water ages based on chlorofluorocarbons (CFCs) and tritium/helium-3 (3H/3He) data were obtained from two arrays of nested piezometers located on the north limb of an anticline in fractured sedimentary rocks in the Valley and Ridge geologic province of Pennsylvania. The fracture geometry of the gently east plunging fold is very regular and consists predominately of south dipping to subhorizontal to north dipping bedding-plane parting and east striking, steeply dipping axial-plane spaced cleavage. In the area of the piezometer arrays, which trend north-south on the north limb of the fold, north dipping bedding-plane parting is a more dominant fracture set than is steeply south dipping axial-plane cleavage. The dating of ground water from the piezometer arrays reveals that ground water traveling along paths parallel to the dip direction of bedding-plane parting has younger 3H/3He and CFC model ages, or a greater component of young water, than does ground water traveling along paths opposite to the dip direction. In predominantly unmixed samples there is a strong positive correlation between age of the young fraction of water and dissolved sodium concentration. The travel times inferred from the model ages are significantly longer than those previously calculated by a ground water flow model, which assumed isotropically fractured layers parallel to topography. A revised model factors in the directional anisotropy to produce longer travel times. Ground water travel times in the watershed therefore appear to be more influenced by anisotropic fracture geometry than previously realized. This could have significant implications for ground water models in other areas underlain by similarly tilted or folded sedimentary rock, such as elsewhere in the Valley and Ridge or the early Mesozoic basins.

Pennsylvania↗

Effect of sewage sludge on formation of acidic ground water at a reclaimed coal mine

Data on rock, ground water, vadose water, and vadose gas chemistry were collected for two years after sewage sludge was applied at a reclaimed surface coal mine in Pennsylvania to determine if surface-applied sludge is an effective barrier to oxygen influx, contributes metals and nutrients to ground water, and promotes the acidification of ground water. Acidity, sulfate, and metals concentrations were elevated in the ground water (6- to 21-m depth) from spoil relative to unmined rock because of active oxidation of pyrite and dissolution of aluminosilicate, carbonate, and Mn-Fe-oxide minerals in the spoil. Concentrations of acidity, sulfate, metals (Fe, Mn, Al, Cd, Cu, Cr, Ni, Zn), and nitrate, and abundances of iron-oxidizing bacteria were elevated in the ground water from sludge-treated spoil relative to untreated spoil having a similar mineral composition; however, gaseous and dissolved oxygen concentrations did not differ between the treatments. Abundances of iron-oxidizing bacteria in the ground water samples were positively correlated with concentrations of ammonia, nitrate, acidity, metals, and sulfate. Concentrations of metals in vadose water samples (<5-m depth) from sludge-treated spoil (pH 5.9) were not elevated relative to untreated spoil (pH 4.4). In contrast, concentrations of nitrate were elevated in vadose water samples from sludge-treated spoil, frequently exceeding 10 mg/L. Downgradient decreases in nitrate to less than 3 mg/L and increases in sulfate concentrations in underlying ground water could result from oxidation of pyrite by nitrate. Thus, sewage sludge added to pyritic spoil can increase the growth of iron-oxidizing bacteria, the oxidation of pyrite, and the acidification of ground water. Nevertheless, the overall effects on ground water chemistry from the sludge were small and probably short-lived relative to the effects from mining only.

Pennsylvania↗

Fractured-aquifer hydrogeology from geophysical logs: Brunswick group and Lockatong Formation, Pennsylvania

The Brunswick Group and the underlying Lockatong Formation are composed of lithified Mesozoic sediments that constitute part of the Newark Basin in southeastern Pennsylvania. These fractured rocks form an important regional aquifer that consists of gradational sequences of shale, siltstone, and sandstone, with fluid transport occurring primarily in fractures. An extensive suite of geophysical logs was obtained in seven wells located at the borough of Lansdale, Pennsylvania, in order to better characterize the areal hydrogeologic system and provide guidelines for the refinement of numerical ground water models. Six of the seven wells are approximately 120 m deep and the seventh extends to a depth of 335 m. Temperature, fluid conductivity, and flowmeter logs are used to locate zones of fluid exchange and to quantify transmissivities. Electrical resistivity and natural gamma logs together yield detailed stratigraphic information, and digital acoustic televiewer data provide magnetically oriented images of the borehole wall from which almost 900 fractures are identified. Analyses of the geophysical data indicate that the aquifer penetrated by the deep well can be separated into two distinct structural domains, which may, in turn, reflect different mechanical responses to basin extension by different sedimentary units: 1. In the shallow zone (above 125 m), the dominant fracture population consists of gently dipping bedding plane partings that strike N46°E and dip to the northwest at about 11 degrees. Fluid flow is concentrated in the upper 80 m along these subhorizontal fractures, with transmissivities rapidly diminishing in magnitude with depth. 2. The zone below 125 m marks the appearance of numerous high-angle fractures that are orthogonal to the bedding planes, striking parallel but dipping steeply southeast at 77 degrees. This secondary set of fractures is associated with a fairly thick (approximately 60 m) high-resistivity, low-transmissivity sandstone unit that is abruptly terminated by a thin shale bed at a depth of 190 m. This lower contact effectively delineates the aquifer's vertical extent at this location because no detectable evidence of ground water movement is found below it. Thus, fluid flow is controlled by fractures, but fracture type and orientation are related to lithology. Finally, a transient thermal-conduction model is successfully applied to simulate observed temperature logs, thereby confirming the effects of ground-surface warming that occurred in the area as a result of urbanization at the turn of the century. The systematic warming of the upper 120 m has increased the transmissivity of this aquifer by almost 10%, simply due to changes in fluid viscosity and density.

Pennsylvania↗

Estimates of ground-water recharge based on streamflow-hydrograph methods: Pennsylvania

This study, completed by the U.S. Geological Survey (USGS) in cooperation with the Pennsylvania Department of Conservation and Natural Resources, Bureau of Topographic and Geologic Survey (T&GS), provides estimates of ground-water recharge for watersheds throughout Pennsylvania computed by use of two automated streamflow-hydrograph-analysis methods--PART and RORA. The PART computer program uses a hydrograph-separation technique to divide the streamflow hydrograph into components of direct runoff and base flow. Base flow can be a useful approximation of recharge if losses and interbasin transfers of ground water are minimal. The RORA computer program uses a recession-curve displacement technique to estimate ground-water recharge from each storm period indicated on the streamflow hydrograph. Recharge estimates were made using streamflow records collected during 1885-2001 from 197 active and inactive streamflow-gaging stations in Pennsylvania where streamflow is relatively unaffected by regulation. Estimates of mean-annual recharge in Pennsylvania computed by the use of PART ranged from 5.8 to 26.6 inches; estimates from RORA ranged from 7.7 to 29.3 inches. Estimates from the RORA program were about 2 inches greater than those derived from the PART program. Mean-monthly recharge was computed from the RORA program and was reported as a percentage of mean-annual recharge. On the basis of this analysis, the major ground-water recharge period in Pennsylvania typically is November through May; the greatest monthly recharge typically occurs in March.

Pennsylvania↗

Occurrence of fecal-indicator bacteria and protocols for identification of fecal-contamination sources in selected reaches of the West Branch Brandywine Creek, Chester County, Pennsylvania

The presence of fecal-indicator bacteria indicates the potential presence of pathogens originating from the fecal matter of warm-blooded animals. These pathogens are responsible for numerous human diseases ranging from common diarrhea to meningitis and polio. The detection of fecal-indicator bacteria and interpretation of the resultant data are, therefore, of great importance to water-resource managers. Current (2005) techniques used to assess fecal contamination within the fluvial environment primarily assess samples collected from the water column, either as grab samples or as depth- and (or) width-integrated samples. However, current research indicates approximately 99 percent of all bacteria within nature exist as attached, or sessile, bacteria. Because of this condition, most current techniques for the detection of fecal contamination, which utilize bacteria, assess only about 1 percent of the total bacteria within the fluvial system and are, therefore, problematic. Evaluation of the environmental factors affecting the occurrence and distribution of bacteria within the fluvial system, as well as the evaluation and modification of alternative approaches that effectively quantify the larger population of sessile bacteria within fluvial sediments, will present water-resource managers with more effective tools to assess, prevent, and (or) eliminate sources of fecal contamination within pristine and impaired watersheds. Two stream reaches on the West Branch Brandywine Creek in the Coatesville, Pa., region were studied between September 2002 and August 2003. The effects of sediment particle size, climatic conditions, aquatic growth, environmental chemistry, impervious surfaces, sediment and soil filtration, and dams on observed bacteria concentrations were evaluated. Alternative approaches were assessed to better detect geographic sources of fecal contamination including the use of turbidity as a surrogate for bacteria, the modification and implementation of sandbag bacteria samplers, and the use of optical brighteners. For the purposes of this report, sources of bacteria were defined as geographic locations where elevated concentrations of bacteria are observed within, or expected to enter, the main branch of the West Branch Brandywine Creek. Biologic sources (for example, waterfowl) were noted where applicable; however, no specific study of biologic sources (such as bacterial source tracking) was conducted. Data indicated that specific bacterial populations within fluvial sediments could be related to specific particle-size ranges. This relation is likely the result of the reduced porosity and permeability associated with finer sediments and the ability of specific bacteria to tolerate particular environments. Escherichia coli (E. coli) showed a higher median concentration (2,160 colonies per gram of saturated sediment) in the 0.125 to 0.5-millimeter size range of natural sediments than in other ranges, and enterococcus bacteria showed a higher median concentration (61,830 colonies per gram of saturated sediment) in the 0.062 to 0.25-millimeter size range of natural sediments than in other ranges. There were insufficient data to assess the particle-size relation to fecal coliform bacteria and (or) fecal streptococcus bacteria. Climatic conditions were shown to affect bacteria concentrations in both the water column and fluvial sediments. Drought conditions in 2002 resulted in lower overall bacteria concentrations than the more typically wet year of 2003. E. coli concentrations in fluvial sediment along the Coatesville study reach in 2002 had a median concentration of 92 colonies per gram of saturated sediment; in 2003, the median concentration had risen to 4,752 colonies per gram of saturated sediment. Symbiotic relations between bacteria and aquatic growth were likely responsible for increased bacteria concentrations observed within an impoundment area on the Coatesville study reach. This reach showed evidence of elevated aquatic growth and sharp increases in E. coli concentrations from upstream to downstream through the impoundment area in both 2002 and 2003. In 2003, E. coli concentrations within the waters column increased from 940 colonies per 100 milliliters upstream to 6,000 colonies per 100 milliliters at the dam crest. Given that these bacteria likely resulted from natural bacterial regrowth, the use of E. coli as an indicator of fecal contamination was severely impaired. Variable environmental conditions along the West Branch Brandywine Creek made the common field-chemical parameters of specific conductance, temperature, pH, and dissolved oxygen ineffective and (or) impossible to use for the determination of inputs of fecal contamination. Extreme variations in chemical gradients commonly were related to the urban/industrial signature of the watershed. For example, during base-flow sampling in 2002, specific-conductance values exceeding 1,000 microsiemens per centimeter observed in effluent from a local steel mill. This effluent raised the specific conductance within the West Branch Brandywine from just above 200 microsiemens per centimeter upstream from the outfall to just below 500 microsiemens per centimeter downstream from the outfall. These chemical gradients also, likely, had an effect on the initial colonization of bacteria, the formation of biofilms, and the persistence of certain types of bacteria along the study reach. Data collected in 2003 indicated that nutrients increased during both base-flow and stormflow conditions along the Coatesville study reach. For example, during base-flow sampling in 2003, 20 pounds of phosphorus was shown to enter the West Branch Brandywine Creek along the Coatesville study reach. The largest contributors to this base-flow nutrient load were likely two wastewater-treatment facilities adjacent to the study reach. During stormflow sampling in 2003, 480 pounds of phosphorus was shown to enter the West Branch Brandywine Creek along the Coatesville study reach. Data, along with other research, indicated the largest contributor to this stormflow nutrient load was likely remobilized sediment originating from a large dam impoundment. These elevated nutrient concentrations were considered sufficient to promote accelerated aquatic growth along the reach. Data collected in 2003 showed that wastewater constituents entered the West Branch Brandywine Creek largely from urban storm-sewer systems. Samples from the primary storm sewer for the city of Coatesville had detections for 20 of 69 wastewater constituents. These constituents included both strong and weak indicators of fecal contamination and generally indicated the storm-sewer system along the Coatesville study reach was a likely source of fecal-indicator bacteria and fecal contamination under base-flow conditions. By comparison, 5 constituents were detected in samples from the upstream end of the reach, and 10 constituents were detected in samples from the downstream end of the reach. During stormflow, numbers of detections were similar along the entire length of the study reach-five in samples from the upstream end, eight in samples from the center of the reach, and seven in samples from the downstream end of the reach. These data indicate that point sources (such as culverts and pipes, septic systems, and wastewater-treatment facilities) are not likely the origin of bacteria contamination during stormflow. The bacteria concentrations observed during stormflow events probably result from remobilized sessile bacteria stored within fluvial sediments. In this case, these bacteria should not be considered indicators of current fecal contamination. Impervious surfaces were found to increase bacteria concentrations along the West Branch Brandywine Creek because contaminated runoff from impervious areas generally flows into, and is concentrated within, the confines of the local storm-sewer system. During 2002, storm-sewer outfalls draining impervious areas were associated with all major locations of elevated bacterial concentrations (greater than 1,200 colonies per gram of saturated sediment) in fluvial sediments. During 2003, wetter conditions and overall bacteria concentrations higher than in 2002 resulted in point sources of bacterial contamination becoming less pronounced; however, the storm-sewer system, draining adjacent impervious areas, was still observed to be the primary source of bacteria along the reach. Where stormwater and (or) other runoff from these areas was allowed to infiltrate and (or) flow through wetland and riparian buffers, bacteria concentrations were not observed to be elevated above background levels commonly observed throughout similar areas of the same reach. Two run-of-the-river dams along the Coatesville study reach were evaluated for their effects on observed bacterial concentrations. These dams were shown to have greater or lesser effects on bacterial concentrations depending on the size of the structure and the capacity of the structure to impede flows. The smaller upstream dam had an approximate height of 3 feet and showed little observed effect on measured turbidity values; these data indicated that the dam did not effectively impede the flow of water or sediment within the West Branch Brandywine Creek. Consequently, this small dam did not show any observed effect on bacterial concentrations either upstream or downstream of the structure. The larger dam, near the middle of the reach, had an approximate height of 20 feet and showed greater effects on both turbidity and bacteria concentrations. The capacity of the larger dam to impede flows, combined with nutrients entering the reach, resulted in increased biologic activity throughout the impoundment area. Within this larger impoundment, enterococcus bacteria populations were observed to decrease sharply and E. coli bacteria populations were observed to increase sharply as flow approached the dam crest. All bacteria levels were then observed to drop to background levels, in both the water column and fluvial sediment, immediately downstream from the dam crest. Additional study is required to determine the cause for this rapid die off. Turbidity was assessed as a potential surrogate for E. coli bacteria. Regression analysis indicated higher turbidity levels usually can indicate higher concentrations of bacteria (R2 = 0.67), but the relation was too sporadic on the West Branch Brandywine Creek to use turbidity as a surrogate for estimated bacteria concentrations. Evaluation of data from individual base-flow and stormflow events resulted in variable and generally poor statistical relations between E. coli bacteria and turbidity (R2 values ranged from 0.02 to 0.94). Sandbag samplers were used in 2003 to determine their suitability for the assessment of fecal contamination. Sandbag samplers rely on the ability of bacteria to attach to surfaces and use the larger sessile bacteria populations instead of the more commonly used planktonic bacteria populations. E. coli bacteria concentrations observed in the sandbag samplers, after 1 week in place, were similar to those found within natural sediments collected concurrently. Enterococcus bacteria concentrations within the same sandbag samplers were not similar, and were generally lower, than those observed within the natural sediments. This discrepancy was likely because sand within the samplers was sieved to a size that was likely too coarse for enterococcus bacteria to persist. Optical-brightener samplers were installed along with each sandbag sampler. Optical brighteners are additives used in common household detergents; therefore, detection of optical brighteners, along with elevated fecal-indicator bacteria concentrations, strongly indicates a link to humans. Positive results for optical brighteners were detected only at the outfalls of two sewage-treatment facilities; because of treatment of the effluent from these facilities, these samples did not have elevated bacteria concentrations. The lack of additional positive results was largely because this method is not sensitive to low concentrations of optical brighteners.

Pennsylvania↗

Effects of historical coal mining and drainage from abandoned mines on streamflow and water quality in Bear Creek, Dauphin County, Pennsylvania — March 1999–December 2002

More than 100 years of anthracite coal mining has changed surface- and ground-water hydrology and contaminated streams draining the Southern Anthracite Coal Field in east-central Pennsylvania. Bear Creek drains the western prong of the Southern Anthracite Coal Field and is affected by metals in drainage from abandoned mines and streamwater losses. Total Maximum Daily Loads (TMDL) developed for dissolved iron of about 5 lb/d (pounds per day) commonly are exceeded in the reach downstream of mine discharges. Restoration of Bear Creek using aerobic ponds to passively remove iron in abandoned mine drainage is under consideration (2004) by the Dauphin County Conservation District. This report, prepared in cooperation with the Dauphin County Conservation District, evaluates chemical and hydrologic data collected in Bear Creek and its receiving waters prior to implementation of mine-drainage treatment. The data collected represent the type of baseline information needed for documentation of water-quality changes following passive treatment of mine drainage in Pennsylvania and in other similar hydrogeologic settings. Seven surface-water sites on Bear Creek and two mine discharges were monitored for nearly three years to characterize the chemistry and hydrology of the following: (1) Bear Creek upstream of the mine discharges (BC-UMD), (2) water draining from the Lykens-Williamstown Mine Pool at the Lykens Water-Level Tunnel (LWLT) and Lykens Drift (LD) discharges, (3) Bear Creek after mixing with the mine discharges (BC-DMD), and (4) Bear Creek prior to mixing with Wiconisco Creek (BCM). Two sites on Wiconisco Creek, upstream and downstream of Bear Creek (WC-UBC and WC-DBC, respectively), were selected to evaluate changes in streamflow and water quality upon mixing with Bear Creek. During periods of below-normal precipitation, streamwater loss was commonly 100 percent upstream of site BC-UMD (streamflow range = 0 to 9.7 ft3/s (cubic feet per second)) but no loss was detected downstream owing to sustained mine water drainage from the Lykens Water-Level Tunnel (range = 0.41 to 3.7 ft3/s), Lykens Drift (range = 0.40 to 6.1 ft3/s), and diffuse zones of seepage. Collectively, mine water inputs contributed about 84 percent of base flow and 53 percent of stormflow measured in the downstream reach. An option under consideration by the Dauphin County Conservation District for treatment of the discharge from the LWLT requires the source of the discharge to be captured and rerouted downstream, bypassing approximately 1,000 feet of stream channel. Because streamwater loss upstream of the tunnel was commonly 100 percent, rerouting the discharge from the LWLT may extend the reach of Bear Creek that is subject to dryness. Differences in the chemistry of water discharging from the LWLT compared to the LD suggest that the flow path through the Lykens-Williamstown Mine Pool to each mine discharge is unique. The LWLT is marginally alkaline (median net acid neutralizing capacity (ANC) = 9 mg/L (milligrams per liter) as CaCO3; median pH = 5.9), commonly becomes acidic (minimum net ANC = -74 mg/L as CaCO3) at low flow, and may benefit from alkaline amendments prior to passive treatment. Water discharging from the LD provides excess ANC (median net ANC = 123 mg/L as CaCO3; median pH = 6.5) to the downstream reach and is nearly anoxic at its source (median dissolved oxygen = 0.5 mg/L). Low dissolved oxygen water with relatively high ANC and metals concentrations discharging from the LD is characteristic of a deeper flow path and longer residence time within the mine pool than the more acidic, oxygenated water discharging from the LWLT. TMDLs for iron have been developed for dissolved species only. Consequently, distinguishing between dissolved and suspended iron in Bear Creek is important for evaluating water-quality improvement through TMDL attainment. Median total iron concentration increased from 550 mg/L (micrograms per liter) at site BC-UM

Pennsylvania↗

Hydrogeologic setting and conceptual hydrologic model of the Spring Creek Basin, Centre County, Pennsylvania, June 2005

The Spring Creek Basin, Centre County, Pa., is experiencing some of the most rapid growth and development within the Commonwealth. This trend has resulted in land-use changes and increased water use, which will affect the quantity and quality of stormwater runoff, surface water, ground water, and aquatic resources within the basin. The U.S. Geological Survey (USGS), in cooperation with the ClearWater Conservancy (CWC), Spring Creek Watershed Community (SCWC), and Spring Creek Watershed Commission (SCWCm), has developed a Watershed Plan (Plan) to assist decision makers in water-resources planning. One element of the Plan is to provide a summary of the basin characteristics and a conceptual model that incorporates the hydrogeologic characteristics of the basin. The report presents hydrogeologic data for the basin and presents a conceptual model that can be used as the basis for simulating surface-water and ground-water flow within the basin. Basin characteristics; sources of data referenced in this text; physical characteristics such as climate, physiography, topography, and land use; hydrogeologic characteristics; and water-quality characteristics are discussed. A conceptual model is a simplified description of the physical components and interaction of the surface- and ground-water systems. The purpose for constructing a conceptual model is to simplify the problem and to organize the available data so that the system can be analyzed accurately. Simplification is necessary, because a complete accounting of a system, such as Spring Creek, is not possible. The data and the conceptual model could be used in development of a fully coupled numerical model that dynamically links surface water, ground water, and land-use changes. The model could be used by decision makers to manage water resources within the basin and as a prototype that is transferable to other watersheds.

Pennsylvania↗

Water budgets for selected watersheds in the Delaware River basin, eastern Pennsylvania and western New Jersey

This pilot study, done by the U.S. Geological Survey in cooperation with the Delaware River Basin Commission, developed annual water budgets using available data for five watersheds in the Delaware River Basin with different degrees of urbanization and different geological settings. A basin water budget and a water-use budget were developed for each watershed. The basin water budget describes inputs to the watershed (precipitation and imported water), outputs of water from the watershed (streamflow, exported water, leakage, consumed water, and evapotranspiration), and changes in ground-water and surface-water storage. The water-use budget describes water withdrawals in the watershed (ground-water and surface-water withdrawals), discharges of water in the watershed (discharge to surface water and ground water), and movement of water of water into and out of the watershed (imports, exports, and consumed water). The water-budget equations developed for this study can be applied to any watershed in the Delaware River Basin. Data used to develop the water budgets were obtained from available long-term meteorological and hydrological data-collection stations and from water-use data collected by regulatory agencies. In the Coastal Plain watersheds, net ground-water loss from unconfined to confined aquifers was determined by using ground-water-flow-model simulations. Error in the water-budget terms is caused by missing data, poor or incomplete measurements, overestimated or underestimated quantities, measurement or reporting errors, and the use of point measurements, such as precipitation and water levels, to estimate an areal quantity, particularly if the watershed is hydrologically or geologically complex or the data-collection station is outside the watershed. The complexity of the water budgets increases with increasing watershed urbanization and interbasin transfer of water. In the Wissahickon Creek watershed, for example, some ground water is discharged to streams in the watershed, some is exported as wastewater, and some is exported for public supply. In addition, ground water withdrawn outside the watershed is imported for public supply or imported as wastewater for treatment and discharge in the watershed. A GIS analysis was necessary to quantify many of the water-budget components. The 89.9-square mile East Branch Brandywine Creek watershed in Pennsylvania is a rural watershed with reservoir storage that is underlain by fractured rock. Water budgets were developed for 1977-2001. Average annual precipitation, streamflow, and evapotranspiration were 46.89, 21.58, and 25.88 inches, respectively. Some water was imported (average of 0.68 inches) into the watershed for public-water supply and as wastewater for treatment and discharge; these imports resulted in a net gain of water to the watershed. More water was discharged to East Branch Brandywine Creek than was withdrawn from it; the net discharge resulted in an increase in streamflow. Most ground water was withdrawn (average of 0.25 inches) for public-water supply. Surface water was withdrawn (average of 0.58 inches) for public-water and industrial supply. Discharge of water by sewage-treatment plants and industries (average of 1.22 inches) and regulation by Marsh Creek Reservoir caused base flow to appear an average of 7.2 percent higher than it would have been without these additional sources. On average, 67 percent of the difference was caused by sewage-treatment-plant and industrial discharges, and 33 percent was caused by regulation of the Marsh Creek Reservoir. Water imports, withdrawals, and discharges have been increasing as the watershed becomes increasingly urbanized. The 64-square mile Wissahickon Creek watershed in Pennsylvania is an urban watershed underlain by fractured rock. Water budgets were developed for 1987-98. Average annual precipitation, streamflow, and evapotranspiration were 47.23, 22.24, and 23.12 inches, respectively. The watershed is highly u

Pennsylvania↗

Drought-sensitive aquifer settings in southeastern Pennsylvania

This report describes the results of a study conducted by the U.S. Geological Survey, in cooperation with the Pennsylvania Department of Conservation and Natural Resources, Bureau of Topographic and Geologic Survey, to determine drought-sensitive aquifer settings in southeastern Pennsylvania. Because all or parts of southeastern Pennsylvania have been in drought-warning or drought-emergency status during 6 of the past 10 years from 1994 through 2004, this information should aid well owners, drillers, and water-resource managers in guiding appropriate well construction and sustainable use of Pennsylvania's water resources. 'Drought-sensitive' aquifer settings are defined for this study as areas unable to supply adequate quantities of water to wells during drought. Using information from previous investigations and a knowledge of the hydrogeology and topography of the study area, drought-sensitive aquifer settings in southeastern Pennsylvania were hypothesized as being associated with two factors - a water-table decline (WTD) index and topographic setting. The WTD index is an estimate of the theoretical water-table decline at the ground-water divide for a hypothetical aquifer with idealized geometry. The index shows the magnitude of ground-water decline after cessation of recharge is a function of (1) distance from stream to divide, (2) ground-water recharge rate, (3) transmissivity, (4) specific yield, and (5) duration of the drought. WTD indices were developed for 39 aquifers that were subsequently grouped into categories of high, moderate, and low WTD index. Drought-sensitive settings determined from the hypothesized factors were compared to locations of wells known to have been affected (gone dry, replaced, or deepened) during recent droughts. Information collected from well owners, drillers, and public agencies identified 2,016 wells affected by drought during 1998-2002. Most of the available data on the location of drought-affected wells in the study area were from Chester and Montgomery Counties because those counties have well-construction regulations that identify wells that failed during drought. The locations of drought-affected wells in Chester and Montgomery Counties indicated the most highly sensitive settings are uplands and slopes in aquifers with high WTD index and uplands in aquifers with moderate WTD index. The least sensitive settings are in aquifers with low WTD index, in valleys, or on slopes. A map was developed showing the relative drought sensitivity (low, moderate, and high) of aquifers in southeastern Pennsylvania. Study results were limited by the inability to obtain much information about the location of drought-affected wells, with the exception of Montgomery and Chester Counties. Also, the construction characteristics (particularly depth) of drought-affected wells generally were not available. Well depth could be used to distinguish between problems caused by shallow well depth (generally less than 100 ft) and those caused by deficiency of the aquifer to supply water. With the exception of owner-derived information from a public survey on drought-affected wells (35 wells), depth data were not obtained. Data from the 35 drought-affected wells indicated most were drilled (not dug) and were completed to depths greater than 100 feet. This finding indicates that the affects of recent droughts in southeastern Pennsylvania were not restricted to shallow dug wells, but also affected deeper drilled wells.

Pennsylvania↗

Hydrogeology and simulation of source areas of water to production wells in a colluvium-mantled carbonate-bedrock aquifer near Shippensburg, Cumberland and Franklin Counties, Pennsylvania

This report presents the results of a study by the U.S. Geological Survey in cooperation with the Shippensburg Borough Authority to evaluate the source areas of water to production wells in a colluvium-mantled carbonate-bedrock aquifer in Cumberland and Franklin Counties, Pa. The areal extent of the zone of contribution was simulated for three production wells near Shippensburg, Pa. by use of a ground-water-flow model. A 111-square-mile area was selected as the model area and includes areas of the South Mountain Section and the Great Valley Section of the Valley and Ridge Physiographic Province. Within the model area, the geologic units in the South Mountain area are predominantly metamorphic rocks and the geologic units in the Great Valley are predominantly carbonate rocks. Hydrologic and geologic information were compiled to establish a conceptual model of ground-water flow. Characteristics of aquifer materials were determined, and streamflow and water levels were measured. Streamflow measurements in November 2003 showed all streams lost water as they flowed from South Mountain over the colluvium-mantled carbonate aquifer into the Great Valley. Some streams lost more than 1 cubic foot per second to the aquifer in this area. The Shippensburg Borough Authority owns three production wells in the model area. Two wells, Cu 969 and Fr 823, are currently (2004) used as production wells and produce 500,000 and 800,000 gallons per day, respectively. Well Cu 970 is intended to be brought on line as a production well in the future. Water levels were measured in 43 wells to use for model calibration. Water-level fluctuations and geophysical logs indicated confined conditions in well Cu 970. Ground-water flow was simulated with a model that consisted of two vertical layers, with five zones in each layer. The units were hydrostratigraphic units that initially were based on geologic formations, but boundaries were adjusted during model calibration. Model calibration resulted in a root mean square error of 9.8 feet. A parameter-estimation package was used during model calibration to estimate three parameters. The parameter estimation resulted in a value of 233 feet per day for horizontal hydraulic conductivity of the highly fractured carbonate rocks and sandy colluvium in layer 1; 3.97 feet per day for horizontal hydraulic conductivity of the ridge-forming unit in layer 1; and a value of 1.73 for horizontal anisotropy in both layers. The calibrated model was used to delineate the areal extent of the zone of contribution for wells Cu 969 and Fr 823. Although well Cu 970 is not currently (2004) being used, the areal extent of its zone of contribution also was simulated without additional model calibration. The shape of the areal extent of the zone of contribution was similar for each well and included an area that extended from the well southwest along the Tomstown Formation, and then extended southeast into the metamorphic rocks of South Mountain. The contributing areas from the watersheds of losing streams were also delineated because losing stream reaches bisect the areal extent of the zones of contribution. Spatial uncertainty of the areal extent of the zone of contribution was illustrated using a Monte-Carlo analysis. The model was run 1,000 times using randomly generated parameter sets that were normally distributed within the confidence interval around the optimal values for the three estimated parameters. The model converged and had a reasonable water budget for 980 of the model runs. For each of those 980 model runs, the recharge area was determined, and the results for all runs were compiled and contoured. The results of the Monte-Carlo analysis were compared to the results of the deterministic model, illustrating that the deterministic model has the greatest certainty in the area closest to each well in the Tomstown Formation. The areas farther from the well, upgradient, and in the metamorphic rocks have a higher degree

Pennsylvania↗

Effects of removing Good Hope Mill Dam on selected physical, chemical, and biological characteristics of Conodoguinet Creek, Cumberland County, Pennsylvania

The implications of dam removal on channel characteris-tics, water quality, benthic invertebrates, and fish are not well understood because of the small number of removals that have been studied. Comprehensive studies that document the effects of dam removal are just beginning to be published, but most research has focused on larger dams or on the response of a sin-gle variable (such as benthic invertebrates). This report, pre-pared in cooperation with the Conodoguinet Creek Watershed Association, provides an evaluation of how channel morphol-ogy, bed-particle-size distribution, water quality, benthic inver-tebrates, fish, and aquatic habitat responded after removal of Good Hope Mill Dam (a small 'run of the river' dam) from Conodoguinet Creek in Cumberland County, Pa. Good Hope Mill Dam was a 6-foot high, 220-foot wide concrete structure demolished and removed over a 3-day period beginning with the initial breach on November 2, 2001, at 10:00 a.m. eastern standard time. To isolate the effects of dam removal, data were collected before and after dam removal at five monitoring stations and over selected reaches upstream, within, and downstream of the impoundment. Stations 1, 2, and 5 were at free-flowing control locations 4.9 miles upstream, 2.5 miles upstream, and 5 miles downstream of the dam, respec-tively. Stations 3 and 4 were located where the largest responses were anticipated, 115 feet upstream and 126 feet downstream of the dam, respectively Good Hope Mill Dam was not an effective barrier to sedi-ment transport. Less than 3 inches of sediment in the silt/clay-size range (less than 0.062 millimeters) coated bedrock within the 7,160-foot (1.4-mile) impoundment. The bedrock within the impoundment was not incised during or after dam removal, and the limited sediment supply resulted in no measurable change in the thalweg elevation downstream of the dam. The cross-sec-tional areas at stations 3 and 4, measured 17 days and 23 months after dam removal, were within 3 percent of the area measured before removal. Some of the impounded silt/clay at station 3 and other sed-iment in the work area downstream of the dam were initially entrained over the 3-day removal period and deposited on sub-strate at station 4. Remaining silt/clay at station 3 and deposits at station 4 were transported downstream by the flows mea-sured over the 23 months after removal (daily mean flow ranged from 38 to 5,180 cubic feet per second). The median bed-parti-cle size at station 3 increased by approximately 32 millimeters in the 23-month period after removal. Bed-particle-size distri-bution at station 4 became finer when silt/clay was initially deposited but coarsened as high flows flushed it downstream; median bed-particle size was 77.7 millimeters before removal compared to 31.3 millimeters 17 days after removal and 99 mil-limeters 23 months after removal. Good Hope Mill Dam had either no effect on water-quality characteristics or the effect was so small it was masked by sea-sonal and periodic variability. Measurements of daily mean temperature, dissolved-oxygen concentration, pH, and specific conductance on a short time scale (every 15 minutes) indicate the daily range of temperature was suppressed under impounded conditions and daily extremes of temperature, dis-solved-oxygen concentration, pH, and specific conductance at station 2 were out of phase by approximately 12 hours with station 3. Once the dam was removed, the pattern at station 3 shifted and converged with the pattern at station 2. The offset before removal may be related to a lag time resulting from a decrease in velocity through the impoundment. Total nitrogen and suspended-sediment concentrations increased upon the initial dam breach but were within the range of concentrations measured from March 2001 through April 2002 over varying flow conditions at station 1. Total nitrogen concentration at station 4 was 4.66 milligrams per liter upon the initial breach of the dam,

Pennsylvania↗

Acidity and Alkalinity in mine drainage: Practical considerations

In this paper, we emphasize that the Standard Method hot peroxide treatment procedure for acidity determination (hot acidity) directly measures net acidity or net alkalinity, but that more than one water-quality measure can be useful as a measure of the severity of acid mine drainage. We demonstrate that the hot acidity is related to the pH, alkalinity, and dissolved concentrations of Fe, Mn, and Al in fresh mine drainage. We show that the hot acidity accurately indicates the potential for pH to decrease to acidic values after complete oxidation of Fe and Mn, and it indicates the excess alkalinity or that required for neutralization of the sample. We show that the hot acidity method gives consistent, interpretable results on fresh or aged samples. Regional data for mine-drainage quality in Pennsylvania indicated the pH of fresh samples was predominantly acidic (pH 2.5 to 4) or near neutral (pH 6 to 7); approximately 25 percent of the samples had intermediate pH values. This bimodal frequency distribution of pH was distinctive for fully oxidized samples; oxidized samples had acidic or near-neutral pH, only. Samples that had nearneutral pH after oxidation had negative hot acidity; samples that had acidic pH after oxidation had positive hot acidity. Samples with comparable pH values had variable hot acidities owing to variations in their alkalinities and dissolved Fe, Mn, and Al concentrations. The hot acidity was comparable to net acidity computed on the basis of initial pH and concentrations of Fe, Mn, and Al minus the initial alkalinity. Acidity computed from the pH and dissolved metals concentrations, assuming equivalents of 2 per mole of Fe and Mn and 3 per mole of Al, was comparable to that computed on the basis of aqueous species and FeII/FeIII. Despite changes in the pH, alkalinity, and metals concentrations, the hot acidities were comparable for fresh and aged samples. Thus, meaningful “net” acidity can be determined from a measured hot acidity or by calculation from the pH, alkalinity, and dissolved metals concentrations. Together, these water-quality data can be useful for evaluating the potential for toxicity, corrosion, or encrustation and can be helpful for determining the appropriate remediation. By demonstrating the measurements on fresh and aged samples, we hope to encourage (1) consistent use of the hot peroxide treatment procedure for acidity determination and (2) consistent reporting of negative acidity values.

Pennsylvania↗

Optimization of limestone drains for long- term treatment of acidic mine drainage, Swatara Creek Basin, Schuylkill County, PA

Limestone drains were constructed in 1995, 1997, and 2000 to treat acidic mine drainage (AMD) from the Orchard, Buck Mtn., and Hegins discharges, respectively, in the Swatara Creek Basin, Southern Anthracite Coalfield, east-central Pennsylvania. This report summarizes the construction characteristics and performance of each of the limestone drains on the basis of influent and effluent quality and laboratory tests of variables affecting limestone dissolution rates. Data for influent and effluent indicate substantial alkalinity production by the Orchard and Buck Mtn. limestone drains and only marginal benefits from the Hegins drain. Nevertheless, the annual alkalinity loading rates have progressively declined with age of all three systems. Collapsible-container (cubitainer) testing was conducted to evaluate current scenarios and possible options for reconstruction and maintenance of the limestone drains to optimize their long-term performance. The cubitainer tests indicated dissolution rates for the current configurations that were in agreement with field flux data (net loading) for alkalinity and dissolved calcium. The dissolution rates in cubitainers were larger for closed conditions than open conditions, but the rates were comparable for coated and uncoated limestone for a given condition. Models developed on the basis of the cubitainer testing indicate (1) exponential declines in limestone mass and corresponding alkalinity loading rates with increased age of limestone drains and (2) potential for improved performance with enlargement, complete burial, and/or regular flushing of the systems.

Pennsylvania↗

From the field: Efficacy of detecting Chronic Wasting Disease via sampling hunter-killed white-tailed deer

Surveillance programs for Chronic Wasting Disease (CWD) in free-ranging cervids often use a standard of being able to detect 1% prevalence when determining minimum sample sizes. However, 1% prevalence may represent >10,000 infected animals in a population of 1 million, and most wildlife managers would prefer to detect the presence of CWD when far fewer infected animals exist. We wanted to detect the presence of CWD in white-tailed deer ( Odocoileus virginianus ) in Pennsylvania when the disease was present in only 1 of 21 wildlife management units (WMUs) statewide. We used computer simulation to estimate the probability of detecting CWD based on a sampling design to detect the presence of CWD at 0.1% and 1.0% prevalence (23-76 and 225-762 infected deer, respectively) using tissue samples collected from hunter-killed deer. The probability of detection at 0.1% prevalence was <30% with sample sizes of ???6,000 deer, and the probability of detection at 1.0% prevalence was 46-72% with statewide sample sizes of 2,000-6,000 deer. We believe that testing of hunter-killed deer is an essential part of any surveillance program for CWD, but our results demonstrated the importance of a multifaceted surveillance approach for CWD detection rather than sole reliance on testing hunter-killed deer.

Pennsylvania↗

Survival rates, mortality causes, and habitats of Pennsylvania white-tailed deer fawns

Estimates of survival and cause-specific mortality of white-tailed deer ( Odocoileus virginianus ) fawns are important to population management. We quantified cause-specific mortality, survival rates, and habitat characteristics related to fawn survival in a forested landscape and an agricultural landscape in central Pennsylvania. We captured and radiocollared neonatal (<3 weeks) fawns in 2000–2001 and monitored fawns from capture until death, transmitter failure or collar release, or the end of the study. We estimated survivorship functions and assessed influence on fawn survival of road density, habitat edge density, habitat patch diversity, and proportion of herbaceous habitat. We captured 110 fawns in the agricultural landscape and 108 fawns in the forested landscape. At 9 weeks after capture, fawn survival was 72.4% (95% Cl = 63.3–80.0%) in the agricultural landscape and 57.2% (95% Cl = 47.5–66.3%) in the forested landscape. Thirty-four-week survival was 52.9% (95% Cl = 42.7–62.8%) in the agricultural landscape and 37.9% (95% Cl = 27.7–49.3%) in the forested landscape. We detected no relationship between fawn survival and road density, percent herbaceous cover, habitat edge density, or habitat patch diversity (all P >0.05). Predation accounted for 46.2% (95% Cl = 37.6–56.7%) of 106 mortalities through 34 weeks. We attributed 32.7% (95% Cl = 21.9–48.6%) and 36.7% (95% Cl = 25.5–52.9%) of 49 predation events to black bears ( Ursus americanus ) and coyotes ( Canis latrans ), respectively. Natural causes, excluding predation, accounted for 27.4% (95% Cl = 20.1–37.3) of mortalities. Fawn survival in Pennsylvania was comparable to reported survival in forested and agricultural regions in northern portions of the white-tailed deer range. We have no evidence to suggest that the fawn survival rates we observed were preventing population growth. Because white-tailed deer are habitat generalists, home-range-scale habitat characteristics may be unrelated to fawn survival; therefore, future studies should consider landscape-related characteristics on fawn survival.

Pennsylvania↗

Assessment of water chemistry, habitat, and benthic macroinvertebrates at selected stream-quality monitoring sites in Chester County, Pennsylvania, 1998-2000

Biological, chemical, and habitat data have been collected from a network of sites in Chester County, Pa., from 1970 to 2003 to assess stream quality. Forty sites in 6 major stream basins were sampled between 1998 and 2000. Biological data were used to determine levels of impairment in the benthic-macroinvertebrate community in Chester County streams and relate the impairment, in conjunction with chemical and habitat data, to overall stream quality. Biological data consisted of benthic-macroinvertebrate samples that were collected annually in the fall. Water-chemistry samples were collected and instream habitat was assessed in support of the biological sampling. Most sites in the network were designated as nonimpacted or slightly impacted by human activities or extreme climatic conditions on the basis of biological-metric analysis of benthic-macroinvertebrate data. Impacted sites were affected by factors, such as nutrient enrichment, erosion and sedimentation, point discharges, and droughts and floods. Streams in the Schuylkill River, Delaware River, and East Branch Brandywine Creek Basins in Chester County generally had low nutrient concentrations, except in areas affected by wastewater-treatment discharges, and stream habitat that was affected by erosion. Streams in the West Branch Brandywine, Christina, Big Elk, and Octoraro Creek Basins in Chester County generally had elevated nutrient concentrations and streambottom habitat that was affected by sediment deposition. Macroinvertebrate communities identified in samples from French Creek, Pigeon Creek (Schuylkill River Basin), and East Branch Brandywine Creek at Glenmoore consistently indicate good stream conditions and were the best conditions measured in the network. Macroinvertebrate communities identified in samples from Trout Creek (site 61), West Branch Red Clay Creek (site 55) (Christina River Basin), and Valley Creek near Atglen (site 34) (Octoraro Creek Basin) indicated fair to poor stream conditions and were the worst conditions measured in the network. Trout Creek is heavily impacted due to erosion, and Valley Creek near Atglen and West Branch Red Clay Creek are influenced by wastewater discharges. Hydrologic conditions in 1999, including a prolonged drought and a flood, influenced chemical concentrations and macroinvertebrate community structure throughout the county. Concentrations of nutrients and ions were lower in 1999 when compared to 1998 and 2000 concentrations. Macroinvertebrate communities identified in samples from 1999 contained lower numbers of individuals when compared to 1998 and 2000 but had similar community structure. Results from chemical and biological sampling in 2000 indicated that the benthic-macroinvertebrate community structure and the concentrations of nutrients and ions recovered to pre-1999 levels.

Pennsylvania↗