Search USGS⌕ Search

Geology topics

Paul M. Buszka

Publications and source records attributed to Paul M. Buszka.

18 recordsLinked to original sources

Water-withdrawal and groundwater-level fluctuations, physical and infiltration characteristics of Ohio River sediment, and isotope-based estimates of water sources relative to a riverbank filtration system in an alluvial aquifer, Louisville, Kentucky, 2000–20

The U.S. Geological Survey and the Louisville Water Company, from 2000 to 2020, cooperatively investigated physical and hydrologic conditions in the Ohio River alluvial aquifer and adjacent riverbed sediments in the northeast part of Louisville, Kentucky, to increase knowledge of processes affecting water sources to collector wells during operation of a riverbank filtration system (RBF). The RBF, in 2020, included an initial collector well (CW1) completed in 1999 and a tunnel and collector well system (TCWS) composed of four collector wells (CW2–CW5) completed in late 2010 that were connected by a tunnel that routed water to a pumping station and a treatment plant. Daily mean water-withdrawal rates typically ranged from about 10.4 to 20.7 million gallons per day (Mgal/d) from 2005 to 2007, then were cyclic from 2008 to 2010 and ranged from as low as about 9 to 13 Mgal/d in winter-spring months up to about 19 to 20 Mgal/d in summer-autumn months. From 2011 through 2017, peak daily mean water-withdrawal rates from CW2–CW5 fluctuated between winter-spring lows of about 20–30 Mgal/d to summer-autumn peak rates of about 41.6 Mgal/d in 2013 to about 48.2 Mgal/d in 2012. From 2017 to 2020, TCWS peak daily mean water-withdrawal rates decreased from about 45.7 Mgal/d in 2017 to about 37.5 Mgal/d in 2020 and peak daily mean rates from CW1 ranged from about 20.7 Mgal/d in 2020 to about 21.6 Mgal/d in 2018. Periods in 2019–20 with tunnel pumping station daily mean water-withdrawal rates smaller than about 30 Mgal/d had generally stable water levels in CW2 and indicated the sustainable yield of the TCWS collector wells under the prevailing hydrologic conditions. Drawdown during July–August of 2008 and 2009 was associated with CW1, the sole operating collector well. Groundwater-flow directions outside the CW1 cone of depression during July–August of 2008 and 2009 were from areas near the alluvial valley margin toward the Ohio River and in 2009 toward Harrods Creek. Collector wells CW2 through CW5 derived water during 2011–19 surveys from surface-water infiltration, as indicated by drawdown that extended beneath the Ohio River and Harrods Creek. Increases in drawdown toward the alluvial valley margins in July–August of 2013 and 2015, compared with July 2011, indicated less available recharge from those flow directions and decreased yield of groundwater from the aquifer after progressively longer TCWS water withdrawals. Drawdown at CW2–CW5 and at observation wells between them lessened in October 2019 and indicated that onshore groundwater levels can recover when collector well withdrawals decrease. Overlapping cones of depression in 2011–15 potentiometric surfaces centered around CW2, CW3, CW4, and CW5, and drawdown along divides between those wells indicated well interference between collector wells. Well-interference effects increased during 2013 and 2015 survey periods, despite decreased water-withdrawal rates compared with July 2011, and expanded to include CW1 when its use resumed. Groundwater-level fluctuations in observation wells near the Ohio River were consistent with gradual depletion of groundwater yield during tunnel pumping station operation at river elevations of about 420 feet above the National Geodetic Vertical Datum of 1929 (NGVD 29) and enhanced recharge of the aquifer when river elevations were above flood stage of about 430 feet above NGVD 29. Groundwater-level declines in observation wells near the Ohio River were most apparent in summer and some autumn months between 2012 and 2017 during periods when tunnel pumping station mean daily water-withdrawal rates were about 35 Mgal/d or more. Periods of relatively stable groundwater levels during 2019–20 in observation wells between CW2–CW5, when tunnel pumping station water-withdrawal rates were about 30–33 Mgal/d or less, also indicated that the prevailing sustainable yield was about 30 Mgal/d or less. Wells associated with CW3 and CW4 had the largest increases in slopes of best-fit lines relating water-level difference to water-withdrawal rate between 2012 and 2020, an indication of decreased efficiencies of those wells to supply water or of changes in groundwater yield around the well. Increased slopes of best-fit lines relating water-level difference to water-withdrawal rate from 2019 to 2020, when groundwater levels were otherwise relatively stable, also indicated that the specific capacity of one or more TCWS collector wells may have declined during that period. Riverbed surface elevation, roughness, and hardness changes between hydroacoustic surveys indicated active accretion and erosion of bed sediment offshore from the riverbank filtration system in 2002–4. Riverbed hydraulic conductivity computed from 2013 to 2015 in tests at 11 sites ranged from 0.2 to 230 feet per day. Ten temporary piezometer sites with adjacent operating collector wells had drawdowns that ranged from about 4 to 11.7 feet and hammer blows greater than or equal to 49 counts, which indicated a relatively great density of alluvial sediments and the potential for diminished riverbed infiltration rates. Contributions of Ohio River infiltration to collector wells estimated from deuterium and oxygen-18 isotopic ratios in representative Ohio River and groundwater samples were considerably larger in warmer months than cooler months and ranged from 80–90 percent in CW1–CW5 in May 2020 to 100 percent in May 2019 at CW2, CW4, and CW5. Groundwater contributions to water withdrawals by collector wells increased in cooler autumn months and ranged from 40 percent at CW3 and CW5 in November 2020 to 70 percent at CW2, CW4, and CW5 in November–December 2019. November 2019 and November 2020 isotopic compositions of water from the collector wells had enriched deuterium and oxygen-18 isotopic ratios consistent with mixtures of evaporation-modified water from the Ohio River and meteoric-origin groundwater.

Indiana, Kentucky↗

Per- and polyfluoroalkyl substances in groundwater from the Great Miami buried-valley aquifer, southwestern Ohio, 2019–20

Groundwater samples were collected during 2019 and 2020 from 23 wells in the Great Miami buried-valley aquifer (GM-BVA) in southwestern Ohio by the U.S. Geological Survey, in cooperation with the Miami Conservancy District, Dayton, Ohio, to determine concentrations of selected per- and polyfluoroalkyl substances (PFAS). The GM-BVA is a glacial outwash and alluvial fill aquifer that is the sole source of water supply for much of the region. Wells had total depths that ranged from 21 to 101 feet below land surface, and groundwater levels that ranged from 1.39 to 52.15 feet below land surface before sampling in 2019. Groundwater and related quality-control samples were sequentially collected from 22 of the 23 wells and analyzed for 24 different PFAS by 2 methods that used proprietary isotope-dilution based adaptations of U.S. Environmental Protection Agency (EPA) method 537.1, termed methods 1 and 2. Method 2 had smaller reporting limits (RL) for 22 of 24 PFAS analyzed and smaller detection limits (DLs) for all 24 PFAS analyzed compared with method 1, which made method 2 more sensitive to detect PFAS. Concentrations of perfluorooctanesulfonate (PFOS) in a groundwater (GW)-method 2 sample from well CL–275 of 1.9 nanograms per liter (ng/L) and perfluorooctanoate (PFOA) in a GW-method 2 sample from well BU–1106 of 2.1 ng/L were greater than their EPA interim health advisory guidances for drinking water (as of June 2022) by about 9,500 and 52,500 percent, respectively. The EPA interim health advisory guidances for PFOS (0.02 ng/L) and PFOA (0.004 ng/L) were also 65 and 215 times less, respectively, than the smallest method 2 DLs for PFOS (1.3 ng/L) and PFOA (0.86 ng/L). Other PFAS were either not detected in GM-BVA groundwater samples or were detected in concentrations less than Ohio action levels or Federal health-risk-based guidance. The most detected PFAS in groundwater was perfluorobutanesulfonate (PFBS), which had concentrations in samples from eight wells that ranged from 1.0 to 8.0 ng/L or from 0.05 to 0.4 percent of its EPA health advisory of 2,000 ng/L for drinking water. The similarity of PFBS (7.8 ng/L), perfluoropentanesulfonate (PFPeS; 8.1 ng/L), and perfluorohexanesulfonate (PFHxS; 14 ng/L) concentrations yielded from the GW-method 1 sample from well CL–275 on July 9, 2019, to those of PFBS (8.0 ng/L), PFPeS (7.8 ng/L), and PFHxS (16 ng/L) from the paired GW-method 2 sample demonstrated the capability of both methods to reproduce PFAS concentrations that were greater than their respective DLs. Non-detection of these PFAS in follow-up GW-method 1 and sequential replicate (Rep–GW-method 1) samples from CL–275 on April 21, 2020, indicated that the 2019 results represented a transient detection in groundwater. Eleven of twenty-three wells sampled in 2019 had from 1 to 4 PFAS detected in one or more groundwater samples or in a paired replicate sample: PFBS in 8 wells and 9 samples; PFHxS in 4 wells and 5 samples; and PFPeS, PFOS, perfluorobutanoate, perfluoropentanoate, PFOA, and perfluorooctanesulfonamide in 1 well and 1 sample each. More PFAS were detected in GW-method 2 samples than GW-method 1 samples because method 2 had smaller RLs and DLs. Results indicate benefits from the analysis of paired samples, sequential replicate samples, and other quality-control samples using analytical methods with sensitive RLs and DLs to verify PFAS concentrations in groundwater. Groundwater-age estimates indicate that water produced from all sampled wells had infiltrated to the water table within the 1947–present (2022) period of PFAS use or environmental presence. Eight wells with detectable PFBS in groundwater from 2019 samples also had groundwater-recharge dates that ranged from 1991 to 2016. Those ages coincided with the possible environmental presence of PFBS as a PFAS byproduct or use as an alternative to PFOS after about 2002. Two wells that had detections of PFHxS in 2019 groundwater samples also had post-2000 groundwater-recharge dates that coincided with the period of use of PFHxS as an alternative to PFOS. Six of nine wells with more than 66-percent of urban land use that was within 0.3 miles of each well, as of 2012, also had 1 to 4 PFAS detected in one of their groundwater samples. Seven of nine wells that produced groundwater in 2019 with an oxic redox category also had one or more PFAS detected in a sample.

Ohio↗

Microbial source tracking and evaluation of best management practices for restoring degraded beaches of Lake Michigan

Attempts to mitigate shoreline microbial contamination require a thorough understanding of pollutant sources, which often requires multiple years of data collection (e.g., point/nonpoint) and the interacting factors that influence water quality. Because restoration efforts can alter shoreline or beach morphology, revisiting source inputs is often necessary. Microbial source tracking (MST) using source-specific molecular markers, genomic community analyses, and physical modeling was used to identify contamination sources along three Lake Michigan beaches of the Laurentian Great Lakes with historically high fecal indicator bacteria (FIB, E. coli ) concentrations. Genetic markers for human (Bacteroides HF183) and mixed gull species ( Catellicoccus marimammalium ) fecal sources were tested from water and sediment. Gene sequencing (16S rRNA) was used to identify similarities in bacterial communities in nearshore water, river inputs, sand, sediment, and groundwater. Synoptic surveys of water exchange were conducted to determine nearshore-offshore interactions of FIB. In addition to these MST studies, best management practices to mitigate FIB, including gull deterrence, slope grading, wetland establishment, and shoreline plantings, were reviewed for their effectiveness at reducing FIB concentrations over time. Using multiple tools for MST helped identify primary and secondary sources of FIB (gulls, stormwater inputs) and the physical processes that exacerbate FIB concentrations (onshore currents, limited circulation). Management actions were successful in the short-term at reducing FIB, but scope of success was temporally limited, with FIB concentrations often rebounding. Results highlight the usefulness of MST to inform best management practices and the need for a sustained adaptive approach that adjusts for changes in the coastal system.

Illinois, Wisconsin↗

Supporting data and simulation of hypothetical bighead carp egg and larvae development and transport in the Ohio River between Markland Locks and Dam and McAlpine Locks and Dam, Kentucky and Indiana, by use of the Fluvial Egg Drift Simulator

Data collection, along with hydraulic and fluvial egg transport modeling, was completed along a 70.9-mile reach of the Ohio River between Markland Locks and Dam and McAlpine Locks and Dam in Kentucky and Indiana. Water-quality data collected in this reach included surface measurements and vertical profiles of water temperature, specific conductance, pH, dissolved oxygen, turbidity, relative chlorophyll, and relative phycocyanin. Data were collected during two surveys: October 27–November 4, 2016, and June 26–29, 2017. Streamflow and velocity data were collected simultaneously with the water-quality data at cross sections and along longitudinal lines (corresponding to the water-quality surface measurements) and at selected stationary locations (corresponding to the water-quality vertical profiles). The data were collected to understand variability of flow and water-quality conditions relative to simulated reaches of the Ohio River and to aid in identifying parts of the reach that may provide conditions favorable to spawning and recruitment habitat for Hypophthalmichthys nobilis (bighead carp). A copy of an existing step-backwater model of Ohio River flows was obtained from the National Weather Service and used to simulate hydraulic conditions for four different streamflows. Streamflows were selected to represent typical conditions ranging from a high-streamflow event to a seasonal dry-weather event, with two streamflows between these extremes for this reach of the Ohio River. Outputs from the hydraulic model, a range of five water temperatures observed in water-quality data, and four potential spawning locations were used as input to the Fluvial Egg Drift Simulator to simulate the extents and quantile positions of developing bighead carp, from egg hatching to the gas bladder inflation stage, under each scenario. A total of 80 simulations were run. Results from the Fluvial Egg Drift Simulator scenarios (which include only the hydraulic influences on survival that result from settling, irrespective of mortality from other physical or biological factors such as excess turbulence, fertilization failure, predation, or starvation) indicate that most eggs will hatch, about half will die, and a quarter of the surviving larvae will reach the gas bladder inflation stage within the model reach. The overall mean percentage of embryos surviving to the gas bladder inflation stage was 13.1 percent. Individual simulations have embryo survival percentages as high as 49.1 percent. The highest embryo survival percentages occurred for eggs spawned at a streamflow of 38,100 cubic feet per second and water temperatures of 24 to 30 degrees Celsius. Conversely, embryo survival percentages were lowest for the lowest and highest streamflows regardless of water temperature or spawn location. Under low water temperature and high-streamflow conditions, some of the eggs did not hatch nor did the larvae reach the gas bladder inflation stage until passing beyond the downstream model domain. Although the final quantile positions of the eggs and larvae beyond the downstream model domain are unknown, the outcomes still provide useful information about conditions favorable to spawning and recruitment habitat for bighead carp in the Ohio River.

Indiana, Kentucky↗

Geochemical characterization of iron and steel slag and its potential to remove phosphate and neutralize acid

Iron and steel slags from legacy and modern operations in the Chicago-Gary area of Illinois and Indiana, USA, are predominantly composed of Ca (10 - 44 wt. % CaO), Fe, (0.3 - 28 wt. % FeO), and Si (10 - 44 wt. % SiO2), with generally lesser amounts of Al (< 1 15 wt. % Al2O3), Mg (2 11 wt. % MgO), and Mn (0.3 9 wt. % MnO). Mineralogy is dominated by CaMgAl silicates, FeCa oxides, Ca-carbonates, and high temperature SiO2 phases. Chromium and Mn concentrations in most samples may be environmentally significant based on comparison with generic soil contaminant guidelines. However, simulated weathering tests suggest these elements are present in generally insoluble phases making use in water treatment applications possible; generation of high pH and alkaline solutions may be an issue. As for water treatment applications, batch and flow-through experiments document effective removal of phosphate from synthetic solutions for nearly all slag samples. Air-cooled fine fractions (< 10 mm) of modern slag were most effective; other types, including modern granulated, modern air-cooled coarse fractions (> 10 mm), and legacy slag removed phosphate, but to a lesser degree. An additional water treatment application is the use of slag to neutralize acidic waters. Most slag samples are extremely alkaline and have high net neutralization potentials (NNP) (400 830 kg CaCO3/t), with the highest approximately equivalent to 80% the neutralization potential of calcite. Overall, phosphate removal capacity and NNP correlate positively with total Ca content and the dissolution of Ca minerals facilitates secondary Ca phosphate formation and consumes acid during hydrolysis. Utilizing locally available slag to treat waste or agricultural waters in this region may be a higher value alternative than use in construction, potentially offsetting restoration costs to degraded legacy areas and decreasing steel manufacturers current waste footprint.

Minerals↗

Geochemistry and microbiology of groundwater and solids from extraction and monitoring wells and their relation to well efficiency at a Federally operated confined disposal facility, East Chicago, Indiana

In cooperation with the U.S. Army Corps of Engineers, Chicago District, the U.S. Geological Survey investigated the processes affecting water quality, geochemistry, and microbiology in representative extraction and monitoring wells at a confined disposal facility (CDF) in East Chicago, Indiana. The CDF is a 140-acre Federally-managed facility that was the former location of an oil refinery and is now used for the long-term disposal and storage of dredge material from the Indiana Harbor and Indiana Harbor Canal. Residual petroleum hydrocarbons and leachate from the CDF are contained within the facility by use of a groundwater cutoff wall. The wall consists of a soil-bentonite slurry and a gradient control system made up of an automated network of 96 extraction wells, 42 monitoring wells, and 2 ultrasonic sensors that maintain an inward hydraulic gradient at the site. The pumps in the extraction wells require vigilant maintenance and must be replaced when unable to withdraw water at a rate sufficient to maintain the required inward gradient. The wells are screened in the Calumet aquifer, a coarse-grained sand and gravel unit that extends approximately 35 feet below the land surface and is not utilized for drinking-water supply at the CDF or in the surrounding area. This study was initiated to identify the cause of decreased pump discharges and to identify potential mitigation strategies. For this study, the U.S. Geological Survey collected groundwater and solids from monitoring and extraction wells. Groundwater samples were collected during June 2014 for precautionary health screening and on four occasions during September 2014 through November 2014. Groundwater samples collected from two extraction wells during June 2014 were analyzed for concentrations of anthropogenic organic constituents. During September through November 2014, groundwater samples were collected from one additional extraction well, and samples from three monitoring wells were analyzed for concentrations of inorganic and organic constituents, dissolved gases, and bacterial abundance and diversity. Solid samples were collected during April 2014, during September 2014 through November 2014, and during November 2016. Solid samples were collected from the exterior of extraction-well pumps and as flocculent from water samples. Solid samples were collected from 10 wells, including 1 extraction well and 3 monitoring wells sampled for water quality. Solid samples were analyzed for mineralogy, solid-phase habit, geochemistry, and organic composition. The following is a list of observations that were made during this study: (1) the water quality is substantially variable among the six well locations sampled as part of this study—lower (more negative) redox values and higher concentrations of many constituents (including calcium, magnesium, sodium, and sulfate) and properties (including dissolved solids, hardness, and turbidity) were detected in sampled wells located near the extraction wells with the highest frequency of failure; (2) water-level drawdown is variable between extraction wells—wells with the greatest drawdown may pull deeper groundwater into the borehole; (3) dissolved gas results indicate reducing oxidation-reduction processes in the aquifer material that can feasibly contribute iron, carbon dioxide, and other byproducts from hydrocarbon degradation to precipitates and solids that accumulate on and impair pump operation; (4) crystalline and amorphous solid-phase minerals are precipitating in the borehole; (5) several types of bacteria are present in water pumped from extraction wells and are likely responsible for bonding mineral and microbiologic matter to the pump (and other well components); and (6) bacteria may create microenvironments that facilitate precipitation of solids or inhibit dissolution of unstable minerals once the bacteria adhere to biofilm attached to the pump. Results of the study indicate that bacteria may be accumulating and entrapping solid material on the exterior of pumps. This accumulation reduces heat transfer and water discharge from the pump and may lead to decreased efficiency or mechanical failure. Observations could not be made on the well screen, gravel pack, or surrounding geologic formation; therefore, mitigating measures in the borehole may not solve well-productivity issues. Remedies for the pump fouling problems were derived from the review and interpretation of data collected during this study and from information documented in other sources about groundwater well fouling. Potential remedies to problems associated with pump fouling at the CDF may include the following: (1) reducing attractiveness of the extraction wells for microbiological growth by modifying the chemical or physical environment of the well, (2) modifying the pump exterior to decrease microbiological adherence, (3) changing the pumping regime to control the chemistry of water entering the well from the surrounding aquifer material, (4) modifying the pumps to be less physically and thermally attractive, and (5) removing hydrocarbons from groundwater and the aquifer material surrounding the wells or adding surfactants to make them more mobile. Pilot scale testing may be necessary to identify the most effective treatment or combination of treatments.

Indiana↗

Identifying and eliminating sources of recreational water quality degradation along an urban coast

Restoration of highly degraded urban coastal waters often requires large-scale, complex projects, but in the interim, smaller-scale efforts can provide immediate improvements to water quality conditions for visitor use. We examined short-term efforts to improve recreational water quality near the Grand Calumet River (GC) in the Laurentian Great Lakes. Identified as an Area of Concern (AOC) by the International Joint Commission, the GC has experienced years of industrial and municipal waste discharges, and as a result, coastal beaches have some of the highest rates of beach closings (>70%) in the United States. Project objectives were to identify sources of microbial contamination and to evaluate a short-term management solution to decrease beach closings: during 2015 (partial) and 2016 (season-long), canines were used to deter gull presence. Water samples were analyzed for Escherichia coli in 2015 and 2016, and fecal sources were evaluated using microbial source tracking markers (2015): human ( Bacteroides HF183, Methanobrevibacter nifH ), gull (Gull2), and dog (DogBact). Hydrometeorological conditions were simultaneously measured. Results indicated that human, gull, and canine fecal sources were present, with gulls being the dominant source. Escherichia coli densities were highly correlated with number of gulls present, Gull2 marker, and turbidity. Gull deterrence decreased E. coli and Gull2 marker detection during 2015, but numbers rebounded after program completion. The full-season program in 2016 resulted in lower E. coli densities and fewer beach closings. Large-scale restoration efforts are underway at this location, but short-term, small-scale projects can be useful for reducing beach closings and restoring ecosystem services.

Indiana↗

Application of hydrogeology and groundwater-age estimates to assess the travel time of groundwater at the site of a landfill to the Mahomet Aquifer, near Clinton, Illinois

The U.S. Geological Survey used interpretations of hydrogeologic conditions and tritium-based groundwater age estimates to assess the travel time of groundwater at a landfill site near Clinton, Illinois (the “Clinton site”) where a chemical waste unit (CWU) was proposed to be within the Clinton landfill unit #3 (CLU#3). Glacial deposits beneath the CWU consist predominantly of low-permeability silt- and clay-rich till interspersed with thin (typically less than 2 feet in thickness) layers of more permeable deposits, including the Upper and Lower Radnor Till Sands and the Organic Soil unit. These glacial deposits are about 170 feet thick and overlie the Mahomet Sand Member of the Banner Formation. The Mahomet aquifer is composed of the Mahomet Sand Member and is used for water supply in much of east-central Illinois. Eight tritium analyses of water from seven wells were used to evaluate the overall age of recharge to aquifers beneath the Clinton site. Groundwater samples were collected from six monitoring wells on or adjacent to the CLU#3 that were open to glacial deposits above the Mahomet aquifer (the upper and lower parts of the Radnor Till Member and the Organic Soil unit) and one proximal production well (approximately 0.5 miles from the CLU#3) that is screened in the Mahomet aquifer. The tritium-based age estimates were computed with a simplifying, piston-flow assumption: that groundwater moves in discrete packets to the sampled interval by advection, without hydrodynamic dispersion or mixing. Tritium concentrations indicate a recharge age of at least 59 years (pre-1953 recharge) for water sampled from deposits below the upper part of the Radnor Till Member at the CLU#3, with older water expected at progressively greater depth in the tills. The largest tritium concentration from a well sampled by this study (well G53S; 0.32 ± 0.10 tritium units) was in groundwater from a sand deposit in the upper part of the Radnor Till Member; the shallowest permeable unit sampled by this study. That result indicated that nearly all groundwater sampled from well G53S entered the aquifer as recharge before 1953. Tritium was detected in a trace concentration in one sample from a second monitoring well open to the upper part of the Radnor Till Member (well G07S; 0.11 ± 0.09 tritium units), and not detected in samples collected from two monitoring wells open to a sand deposit in the lower part of the Radnor Till Member, from two samples collected from two monitoring wells open to the Organic Soil unit, and in two samples collected from a production well screened in the middle of the Mahomet aquifer (a groundwater sample and a sequential replicate sample). The lack of tritium in five of the six groundwater samples collected from the shallow permeable units beneath CLU#3 site and the two samples from the one Mahomet aquifer well indicates an absence of post-1952 recharge. Groundwater-flow paths that could contribute post-1952 recharge to the lower part of the Radnor Till Member, the Organic Soil unit, or the Mahomet aquifer at the CLU#3 are not indicated by these data. Hypothetical two-part mixtures of tritium-dead, pre-1953 recharge water and decay-corrected tritium concentrations in post-1952 recharge were computed and compared with tritium analyses in groundwater sampled from monitoring wells at the CLU#3 site to evaluate whether tritium concentrations in groundwater could be represented by mixtures involving some post-1952 recharge. Results from the hypothetical two-part mixtures indicate that groundwater from monitoring well (G53S) was predominantly composed of pre-1953 recharge and that if present, younger, post-1955 recharge, contributed less than 2.5 percent to that sample. The hypothetical two-part mixing results also indicated that very small amounts of post-1952 recharge composing less than about 2.5 percent of the sample volume could not be distinguished in groundwater samples with tritium concentrations less than about 0.15 TU. The piston-flow based age of recharge determined from the tritium concentration in the groundwater sample from monitoring well G53S yielded an estimated maximum vertical velocity from the land surface to the upper part of the Radnor Till Member of 0.85 feet per year or less. This velocity, ifassumed to apply to the remaining glacial till deposits above the Mahomet aquifer, indicates that recharge flows through the 170 feet of glacial deposits between the base of the proposed chemical waste unit and the top of the Mahomet aquifer in a minimum of 200 years or longer. Analysis of hydraulic data from the site, constrained by a tritium-age based maximum groundwater velocity estimate, computed minimum estimates of effective porosity that range from about 0.021 to 0.024 for the predominantly till deposits above the Mahomet aquifer. Estimated rates of transport of recharge from land surface to the Mahomet aquifer for the CLU#3 site computed using the Darcy velocity equation with site-specific data were about 260 years or longer. The Darcy velocity-based estimates were computed using values that were based on tritium data, estimates of vertical velocity and effective porosity and available site-specific data. Solution of the Darcy velocity equation indicated that maximum vertical groundwater velocities through the deposits above the aquifer were 0.41 or 0.61 feet per year, depending on the site-specific values of vertical hydraulic conductivity (laboratory triaxial test values) and effective porosity used for the computation. The resulting calculated minimum travel times for groundwater to flow from the top of the Berry Clay Member (at the base of the proposed chemical waste unit) to the top of the Mahomet aquifer ranged from about 260 to 370 years, depending on the velocity value used in the calculation. In comparison, plausible travel times calculated using vertical hydraulic conductivity values from a previously published regional groundwater flow model were either slightly less than or longer than those calculated using site data and ranged from 230 to 580 years. Tritium data from 1996 to 2011 USGS regional sampling of groundwater from domestic wells in the confined part of the Mahomet aquifer—which are 2.5 to about 40 miles from the Clinton site—were compared with site-specific data from a production well at the Clinton site. Tritium-based groundwater-age estimates indicated predominantly pre- 1953 recharge dates for USGS and other prior regional samples of groundwater from domestic wells in the Mahomet aquifer. These results agreed with the tritium-based, pre-1953 recharge age estimated for a groundwater sample and a sequential replicate sample from a production well in the confined part of the Mahomet aquifer beneath the Clinton site. The regional tritium-based groundwater age estimates also were compared with pesticide detections in samples from distal domestic wells in the USGS regional network that are about 2.5 to 40 miles from the Clinton site to identify whether very small amounts of post-1952 recharge have in places reached confined parts of the Mahomet aquifer at locations other than the Clinton site in an approximately 2,000 square mile area of the Mahomet aquifer. Very small amounts of post-1952 recharge were defined in this analysis as less than about 2.5 percent of the total recharge contributing to a groundwater sample, based on results from the two-part mixing analysis of tritium data from the Clinton site. Pesticide-based groundwater-age estimates based on 22 detections of pesticides (13 of these detections were estimated concentrations), including atrazine, deethylatrazine (2-Chloro-4-isopropylamino-6-amino- s-triazine), cyanazine, diazinon, metolachlor, molinate, prometon, and trifluralin in groundwater samples from 10 domestic wells 2.5 to about 40 miles distant from the Clinton site indicate that very small amounts of post-1956 to post-1992 recharge can in places reach the confined part of the Mahomet aquifer in other parts of central Illinois. The relative lack of tritium in these samples indicate that the amounts of post-1956 to post-1992 recharge contributing to the 10 domestic wells were a very small part of the overall older groundwater sampled from those wells. The flow process by which very small amounts of pesticide-bearing groundwater reached the screened intervals of the 10 domestic wells could not be distinguished between well-integrity related infiltration and natural hydrogeologic features. Potential explanations include: (1) infiltration through man-made avenues in or along the well, (2) flow of very small amounts of post-1956 to post-1992 recharge through sparsely distributed natural permeable aspects of the glacial till and diluted by mixing with older groundwater, or (3) a combination of both processes. Presuming the domestic wells sampled by the USGS in 1996–2011 in the regional study of the confined part of the Mahomet aquifer are adequately sealed and produce groundwater that is representative of aquifer conditions, the regional tritium and pesticide-based groundwater-age results indicate substantial heterogeneity in the glacial stratigraphy above the Mahomet aquifer. The pesticide-based groundwater-age estimates from the domestic wells distant from the Clinton site also indicate that parts of the Mahomet aquifer with the pesticide detections can be susceptible to contaminant sources at the land surface. The regional pesticide and tritium results from the domestic wells further indicate that a potential exists for possible contaminants from land surface to be transported through the glacial drift deposits that confine the Mahomet aquifer in other parts of central Illinois at faster rates than those computed for recharge at the Clinton site, including CLU#3. This analysis indicates the potential value of sub-microgram-per-liter level concentrations of land-use derived indicators of modern recharge to indicate the presence of very small amounts of modern, post-1952 age recharge in overall older, pre-1953 age groundwater.

Illinois↗

Relation of hydrologic processes to groundwater and surface-water levels and flow directions in a dune-beach complex at Indiana Dunes National Lakeshore and Beverly Shores, Indiana

The potential for high groundwater levels to cause wet basements (groundwater flooding) is of concern to residents of communities in northwestern Indiana. Changes in recharge from precipitation increases during 2006-9, water-level changes from restoration of nearby wetlands in the Great Marsh in 1998-2002, and changes in recharge due to the end of groundwater withdrawals for water supply since 2005 in a community at Beverly Shores, Ind., were suspected as factors in increased groundwater levels in an unconfined surficial aquifer beneath nearby parts of a dune-beach complex. Results of this study indicate that increased recharge from precipitation and snowmelt was the principal cause of raised water levels in the dune-beach complex from 2006 to 2009. Annual precipitation totals in 2006-9 ranged from 43.88 to 55.75 inches per year (in/yr) and were substantially greater than the median 1952-2009 precipitation of 36.35 in/yr. Recharge to groundwater from precipitation in 2006-9 ranged from 13.5 to 22 in/yr; it was higher than the typical 11 in/yr because of large precipitation events and precipitation amounts received during non-growing-season months. An estimated increase in net recharge from reduced groundwater use in Beverly Shores since 2005 ranged from 1.6 in/yr in 2006 to 1.9 in/yr in 2009. Surface-water levels in the wetland were as much as about 1.1 feet higher in 2007-9 (after the 1998-2002 wetland restoration) than during seasonally wet periods in 1979-89. Similar surface-water levels and ponded water were likely during winter and spring wet periods before and after wetland restoration. High water levels similar to those in 2009 were measured elsewhere in the dune-beach complex near a natural wetland during the spring months in 1991 and 1993 after receipt of near record precipitation. Recharge from similarly high precipitation amounts in 2008-9 was also a likely cause of high groundwater levels in other parts of the dune-beach complex, such as at Beverly Shores. Perennial mounding of the water table in the surficial aquifer indicates that the recharge that created the water-table mound originates within the dune-beach complex and not through flow from the adjacent hydrologic boundaries: the restored wetland, Lake Michigan, and Derby Ditch. Infiltrating precipitation causes most seasonal and episodic rises in groundwater levels beneath the dune-beach complex. Groundwater-level fluctuations lasting days to weeks in the dune-beach complex in 2008-9 were superimposed on a seasonal high water-table altitude that began with the recharge from snowmelt and rain in February 2009 and maintained through July 2009. Increases in water-table-mound altitude under the dune-beach complex recurred in 2008-9 in response to the largest rain events of 1 inch or more and to snowmelt. Smaller, shorter-term rises in water level after individual rain events persisted over hours to less than 1 week. Groundwater-level fluctuations varied over a relatively narrow range of about 2 to 3 feet, with no net fluctuations greater than 4 feet. Groundwater levels in or near low parts of the dune-beach complex were frequently within 0 to 6 feet of the land surface and indicate the potential for groundwater flooding. Groundwater-level gradients from the water-table mound to wells next to surface-water discharges increase after rainfall and snowmelt events and recede slowly as groundwater discharges from the aquifer. Evapotranspiration is responsible for part of the general pattern of decreasing water-table altitudes observed from May to August 2009. Rapid water-level rises in the restored wetland after precipitation do not likely have an effect on groundwater flooding elsewhere in the dune-beach complex. Surface-water-level fluctuations during this study generally varied over a narrower range, approximately from 1 to 1.5 feet, as compared with groundwater fluctuations, except after a very large, 10.77-inch rainfall. Time-delayed and smaller groundwater-level

Indiana↗

Estimates of groundwater age from till and carbonate bedrock hydrogeologic units at Jefferson Proving Ground, Southeastern Indiana, 2007-08

During 2007-08, the U.S. Geological Survey, in cooperation with the U.S. Department of the Army, conducted a study to evaluate the relative age of groundwater in Pre-Wisconsinan till and underlying shallow and deep carbonate bedrock units in and near an area at Jefferson Proving Ground (JPG), southeastern Indiana, which was used during 1984-94 to test fire depleted uranium (DU) penetrators. The shallow carbonate unit includes about the upper 40 feet of bedrock below the bedrock-till surface; the deeper carbonate unit includes wells completed at greater depth. Samples collected during April 2008 from 15 wells were analyzed for field water-quality parameters, dissolved gases, tritium, and chlorofluorocarbon (CFC) compounds; samples from 14 additional wells were analyzed for tritium only. Water-level gradients in the Pre-Wisconsinan till and the shallow carbonate unit were from topographically higher areas toward Big Creek and Middle Fork Creek, and their tributaries. Vertical gradients were strongly downward from the shallow carbonate unit toward the deep carbonate unit at 3 of 4 paired wells where water levels recovered after development; indicating the general lack of flow between the two units. The lack of post development recovery of water levels at 4 other wells in the deep carbonate unit indicate that parts of that unit have no appreciable permeability. CFC and tritium-based age dates of Pre-Wisconsinan till groundwater are consistent with infiltration of younger (typically post-1960 age) recharge that 'mixes' with older recharge from less permeable or less interconnected strata. Part of the recharge to three till wells dated from the early to mid-1980s (JPG-DU-03O, JPG-DU-09O, and JPG-DU-10O). Age dates of young recharge in water from two till wells predated 1980 (JPG-DU-04O and JPG-DU-06O). Tritium-based age dates of water from seven other till wells indicated post-1972 age recharge. Most wells in the Pre-Wisconsinan till have the potential to produce groundwater that partially was recharged during or after DU penetrator testing; their water quality can indicate the presence of DU-related contaminants. The shallow carbonate unit near Big Creek is a karst flow system that may be recharged in part from areas with smaller thicknesses of overlying till or through more permeable parts of the till. This is indicated by CFC- and tritium-based piston-flow (non-mixing) model age dates of early-1980s for water from JPG-DU-02I, similar tritium-based ages of water produced from nearby wells MW-5 and MW-11, and cave development along the creek. The CFC and tritium-based age dates indicate that water samples from JPG-DU-01I and JPG-DU-03I were best described as mixtures of post-1984 modern recharge and submodern (1953 or older) recharge. These five wells produced groundwater that was recharged, at least partially, during or after DU-penetrator testing and are within or downgradient from the DU Impact Area with respect to groundwater flow directions inferred from water-level contours. Wells with groundwater age dates that are near to or after the onset (1984) of DU penetrator testing and that have a plausible connection to a contaminant source can be used to indicate the presence or absence of contaminants from DU penetrator or DU-related corrosion products in groundwater. Groundwater-age dates indicate that the ages of recharge sampled from shallow carbonate unit wells JPG-DU-04I, JPG-DU-05I, JPG-DU-06I, JPG-DU-09I, and JPG-DU-10D in easternmost (upgradient) and southernmost wells in the shallow carbonate unit are submodern (1953 or older) and predate the DU testing by at least 30 or more years. Water-quality data from these five wells are not likely to represent effects from DU-projectile testing or corrosion for years. Well JPG-DU-09D in the deep carbonate unit produced groundwater samples with a submodern (1953 or older) age date. The slow recovery of water levels in most wells in the deep carbonate unit is consis

Indiana↗

Hydrogeology, Ground-Water-Age Dating, Water Quality, and Vulnerability of Ground Water to Contamination in a Part of the Whitewater Valley Aquifer System near Richmond, Indiana, 2002-2003

Assessments of the vulnerability to contamination of ground-water sources used by public-water systems, as mandated by the Federal Safe Drinking Water Act Amendments of 1996, commonly have involved qualitative evaluations based on existing information on the geologic and hydrologic setting. The U.S. Geological Survey National Water-Quality Assessment Program has identified ground-water-age dating; detailed water-quality analyses of nitrate, pesticides, trace elements, and wastewater-related organic compounds; and assessed natural processes that affect those constituents as potential, unique improvements to existing methods of qualitative vulnerability assessment. To evaluate the improvement from use of these methods, in 2002 and 2003, the U.S. Geological Survey, in cooperation with the City of Richmond, Indiana, compiled and interpreted hydrogeologic data and chemical analyses of water samples from seven wells in a part of the Whitewater Valley aquifer system in a former glacial valley near Richmond. This study investigated the application of ground-water-age dating, dissolved-gas analyses, and detailed water-quality analyses to quantitatively evaluate the vulnerability of ground water to contamination and to identify processes that affect the vulnerability to specific contaminants in an area of post-1972 greenfield development. The aquifer system in the study area includes an unconfined sand and gravel aquifer used for public-water supply (upper aquifer) and a confined sand and gravel aquifer (lower aquifer) separated by a till confining unit. Several hydrogeologic and cultural measures indicate that the upper aquifer is qualitatively vulnerable to contamination: the upper aquifer is unconfined and has a shallow depth to the water table (from about 4.75 to 14 feet below land surface), low-permeability sediments in the unsaturated zone are thin (less than 10 feet thick), estimated ground-water-flow rates through the upper aquifer are relatively rapid (the highest estimated rates ranged from 0.44 to about 5.0 feet per day), and potential contaminant sources were present. Ground-water-age dates indicate that ground-water samples represented recharge from about the time greenfield development began south of the ground-water-flow divide and that changes in water quality would lag changes in contaminant inputs. Estimates of ground-water age, computed with dichlorodifluoromethane (CFC-12) and trichlorotrifluoroethane (CFC-113) concentrations in water samples collected from seven observation wells in February and March 2003, indicated that water in the upper aquifer had recharged within about 13 to 30 years before sampling. Ground-water ages were youngest (from about 13 to 15 years since recharge) in water from the shallow wells along the glacial-valley margin and oldest (30 years) in water from a well at the base of the aquifer in the valley center. Ground-water ages determined for the shallow wells may be affected by mixing of recent recharge with older ground water from deeper in the aquifer, as indicated by upward hydraulic gradients between paired shallow and deep wells in the upper aquifer. Other parts of the Whitewater Valley aquifer system with similar hydrogeologic characteristics could be expected to have similarly young ground-water ages and residence times. Analyses of water samples collected from the seven observation wells in August and September 2002 indicated that concentrations of chloride, sodium, and nitrate generally were larger in ground water from the upper aquifer than in other parts of the Whitewater Valley aquifer system. Drinking-water-quality standards for Indiana were exceeded in water samples from one well for chloride concentrations, from four wells for dissolved-solids concentrations, and from one well for nitrate concentrations. Application of low-level methods for trace-element analyses determined that concentrations of aluminum, cobalt, iron, lithium, molybdenum, nickel, selenium, uranium, vanadium, and zinc were less than or equal to 8 micrograms per liter; concentrations of arsenic, cadmium, chromium, and copper were less than or equal to 1 microgram per liter. Application of low-level analytical methods to water samples enabled the detection of several pesticides and volatile, semivolatile, and wastewater-related organic compounds; concentrations of individual pesticides and volatile organic compounds were less than 0.1 microgram per liter and concentrations of individual wastewater organic compounds were less than 0.5 microgram per liter. The low-level analytical methods will provide useful data with which to compare future changes in water quality. Results of detailed water-quality analyses, ground-waterage dating, and dissolved-gas analyses indicated the vulnerability of ground water to specific types of contamination, the sequence of contaminant introduction to the aquifer relative to greenfield development, and processes that may mitigate the contamination. Concentrations of chloride and sodium and chloride/bromide weight ratios in sampled water from five wells indicated the vulnerability of the upper aquifer to roaddeicer contamination. Ground-water-age estimates from these wells indicated the onset of upgradient road-deicer use within the previous 25 years. Nitrate in the upper aquifer predates the post-1972 development, based on a ground-water-age date (30 years) and the nitrate concentration (5.12 milligrams per liter as nitrogen) in water from a deep well. Vulnerability of the aquifer to nitrate contamination is limited partially by denitrification. Detection of one to four atrazine transformation products in water samples from the upper aquifer indicated biological and hydrochemical processes that may limit the vulnerability of the ground water to atrazine contamination. Microbial processes also may limit the aquifer vulnerability to small inputs of halogenated aliphatic compounds, as indicated by microbial transformations of trichlorofluoromethane and trichlorotrifluoroethane relative to dichlorodifluoromethane. The vulnerability of ground water to contamination in other parts of the aquifer system also may be mitigated by hydrodynamic dispersion and biologically mediated transformations of nitrate, pesticides, and some organic compounds. Identification of the sequence of contamination and processes affecting the vulnerability of ground water to contamination would have been unlikely with conventional assessment methods.

Indiana, Ohio↗

Evaluation of ground-water and boron sources by use of boron stable-isotope ratios, tritium, and selected water-chemistry constituents near Beverly Shores, northwestern Indiana, 2004

Concentrations of boron greater than the U.S. Environmental Protection Agency (USEPA) 900 μg/L removal action level (RAL) standard were detected in water sampled by the USEPA in 2004 from three domestic wells near Beverly Shores, Indiana. The RAL regulates only human-affected concentrations of a constituent. A lack of well logs and screened depth information precluded identification of whether water from sampled wells, and their boron sources, were from human-affected or natural sources in the surficial aquifer, or associated with a previously defined natural, confined aquifer source of boron from the subtill or basal sand aquifers. A geochemically-based classification of the source of boron in ground water could potentially determine the similarity of boron to known sources or mixtures between known sources, or classify whether the relative age of the ground water predated the potential sources of contamination. The U.S. Geological Survey (USGS), in cooperation with the USEPA, investigated the use of a geochemical method that applied boron stable isotopes, and concentrations of boron, tritium, and other constituents to distinguish between natural and human-affected sources of boron in ground water and thereby determine if the RAL was applicable to the situation. Boron stable-isotope ratios and concentrations of boron in 17 ground-water samples and tritium concentrations in 9 ground-water samples collected in 2004 were used to identify geochemical differences between potential sources of boron in ground water near Beverly Shores, Indiana. Boron and δ 11 B analyses for this investigation were made on unacidified samples to assure consistency of the result with unacidified analyses of δ 11 B values from other investigations. Potential sources of boron included surficial-aquifer water affected by coal-combustion products (CCP) or domestic-wastewater, upward discharge of ground water from confined aquifers, and unaffected water from the surficial aquifer that was distant from human-affected boron sources. Boron concentrations in potential ground-water sources of boron were largest (15,700 to 24,400 μg/L) in samples of CCP-affected surficial aquifer water from four wells at a CCP landfill and smallest (27 to 63 μg/L) in three wells in the surficial aquifer that were distant from human-affected boron sources. Boron concentrations in water from the basal sand aquifer ranged from 656 μg/L to 1,800 μg/L. Boron concentrations in water from three domestic-wastewater-affected surficial aquifer wells ranged from 84 to 387 μg/L. Among the representative ground-water samples, boron concentrations from all four samples of CCP-affected surficial aquifer water and four of five samples of water from the basal sand aquifer had concentrations greater than the RAL. A comparison of boron concentrations in acid-preserved and unacidified samples indicated that boron concentrations reported for this investigation may be from about 11 to 16 percent less than would be reported in a standard analysis of an acidified sample. The stable isotope boron-11 was most enriched in comparison to boron-10 in ground water from a confined aquifer, the basal sand aquifer (δ 11 B, 24.6 to 34.0 per mil, five samples); it was most depleted in CCP-affected water from the surficial aquifer (δ 11 B, 0.1 to 6.6 per mil, four samples). Domestic-wastewater-affected water from the surficial aquifer (δ 11 B, 8.7 to 11.7 per mil, four samples) was enriched in boron-11, in comparison to individual samples of a borax detergent additive and a detergent with perborate bleach; it was intermediate in composition between basal sand aquifer water and CCP-affected water from the surficial aquifer. The similarity between a ground-water sample from the surficial aquifer and a hypothetical mixture of unaffected surficial aquifer and basal sand aquifer waters indicates the potential for long-term upward discharge of ground water into the surficial aquifer from one or more confined aquifers. Estimated δ 11 B values for acidified samples were depleted by 1.9 to 2.8 per mil in comparison to unacidified samples from the four wells sampled; those differences were small in comparison to the differences between δ 11 B values of representative sources of boron in ground water. Tritium concentrations ranged from 7.0 to 10.3 tritium units in six samples from the surficial aquifer and were less than 0.8 tritium units in three samples from the basal sand aquifer. Water from wells in the surficial aquifer represents predominantly modern, post-1972 recharge and sources of boron and other constituents. Water from the basal sand aquifer is associated with pre-1952 recharge from sources not affected by local boron inputs. Ground water from six wells (five domestic wells and one public-supply well) where the ground-water source was unknown had boron concentrations, boron isotope ratios, and tritium concentrations similar to water from the basal sand aquifer. Boron concentrations greater than the RAL were found in water from four of these six wells. The boron isotope and tritium data from these four wells indicate a natural source of boron in ground water; therefore, the RAL does not apply to boron concentrations in water from these wells. Water samples from two domestic wells where the ground-water source was unknown had boron concentrations less than the RAL and boron isotope ratios and tritium concentrations that were similar to domestic-wastewater-affected water from the surficial aquifer. The boron isotope ratio for a sample from one domestic well was similar to that of CCP-affected water from the surficial aquifer and detergent compositions; the boron concentration of that sample was less than the RAL. The classifications of differences among representative sources of boron in ground water and water samples from wells where the ground-water source was unknown generally agreed with distinctions based on strontium-87/strontium-86 ratios and concentrations of strontium, chloride, nitrate, and ammonia. This application of boron concentrations, boron isotope ratios, and tritium concentrations to classify differences in relation to potential sources of boron in ground water was able to distinguish between boron from natural sources and from human-affected sources that are subject to regulation.

Indiana↗

Reconnaissance of surface-water and ground-water quality at the Lincoln Boyhood National Memorial near Lincoln City, Indiana, 2001-02

In cooperation with the National Park Service, the U.S. Geological Survey investigated water quality of key water bodies at the Lincoln Boyhood National Memorial near Lincoln City in southwestern Indiana. The key water bodies were a stock pond, representing possible nonpoint agricultural effects on water quality; an ephemeral stream, representing the water quality of drainage from forested areas of the park; parking-lot runoff, representing water quality related to roads and parking lots; an unnamed ditch below the parking lot, representing the water quality of drainage from the parking lot and from an adjacent railroad track; and Lincoln Spring, a historical ground-water source representing ground-water conditions near a former diesel-fuel-spill site along a rail line. Water samples were analyzed for pH, temperature, specific conductance, and dissolved oxygen and for concentrations of selected major ions and trace metals, nutrients, organic constituents, and Escherichia coli bacteria. Surface-water-quality data of water samples from the park represent baseline conditions for the area in relation to the data available from previous studies of area streams. Specific-conductance values and concentrations of most major ions and various nutrients in surface-water samples from the park were smaller than those reported for samples collected in other USGS studies in areas adjacent to the park. Water-quality-management issues identified by this investigation include potentially impaired water quality from parking-lot runoff, unknown effects on surface-water quality from adjacent railroads, and the potential impairment of water quality in Lincoln Spring from human influences. Parking-lot runoff is a source of calcium, alkalinity, iron, lead, and organic carbon in the water samples from the unnamed ditch. Detection of small concentrations of petroleum hydrocarbons in water from Lincoln Spring could indicate residual contamination from a 1995 diesel-fuel spill and cleanup. The concentration of nitrite plus nitrate in water from Lincoln Spring was 16.5 milligrams per liter as nitrogen, greater than the State of Indiana standard for nitrate in drinking water (10 milligrams per liter as nitrogen). Lead concentrations in samples from the stock pond, parking-lot runoff, and the unnamed ditch exceeded the Indiana chronic aquatic criteria.

Indiana↗

Effects of highway-deicer application on ground-water quality in a part of the Calumet Aquifer, northwestern Indiana

The effects of highway-deicer application on ground-water quality were studied at a site in northwestern Indiana using a variety of geochemical indicators. Site characteristics such as high snowfall rates; large quantities of applied deicers; presence of a high-traffic highway; a homogeneous, permeable, and unconfined aquifer; a shallow water table; a known ground-water-flow direction; and minimal potential for other sources of chloride and sodium to complicate source interpretation were used to select a study area where ground water was likely to be affected by deicer application. Forty-three monitoring wells were installed in an unconfined sand aquifer (the Calumet aquifer) near Beverly Shores in northwestern Indiana. Wells were installed along two transects that approximately paralleled groundwater flow in the Calumet aquifer and crossed US–12. US–12 is a highway that receives Indiana’s highest level of maintenance to maintain safe driving conditions. Ground-water quality and water-level data were collected from the monitoring wells, and precipitation and salt-application data were compiled from 1994 through 1997. The water-quality data indicated that chloride was the most easily traced indicator of highway deicers in ground water. Concentration ratios of chloride to iodide and chloride to bromide and Stiff diagrams of major element concentrations indicated that the principal source of chloride and sodium in ground water from the uppermost one-third to one-half of the Calumet aquifer and downgradient from US–12 was from a halite highway-deicer source. Borehole logs of relative electromagnetic conductivity defined a distinct plume of deicer-affected water in the uppermost 8 feet of aquifer at about 9 feet horizontally from the paved roadway edge and a zone of higher conductivity than background in the lower one-third of the aquifer. Chloride and sodium in the deep parts of the aquifer originated from natural sources. Chloride and sodium from highway deicers were present in the aquifer throughout the year. The highest concentrations of chloride and sodium in ground water were determined in samples collected during the spring and summer from wells open to the water table within about 9 feet of the highway. Chloride concentrations in ground water that were attributable to highway deicers also were found in tested wells about 400 feet downgradient from US–12 during the fall and winter and at greater depths than in wells closer to US–12. Chloride concentrations exceeded the U.S. Environmental Protection Agency’s (USEPA) secondary maximum contaminant level of 250 milligrams per liter for drinking water at seven wells downgradient from the highway during late winter, spring, and summer samplings. The chloride standard was exceeded only in water from wells with total depths that are less than about 10 feet below land surface. Sodium concentrations in water periodically exceeded the USEPA drinking-water equivalency level of 20 milligrams per liter in both the uppermost (deicer 2 Effects of Highway-Deicer Application on Ground-Water Quality in a Part of the Calumet Aquifer, Northwestern Indiana affected) and lower one-thirds of the aquifer. Sodium concentrations in ground water downgradient from US–12 and in the upper 5 feet of the aquifer also occasionally exceeded drinking-water standards for sodium (160 milligrams per liter) as set by the State of Florida and a standard for taste (200 milligrams per liter) as set by the World Health Organization. Dispersion was identified by analysis of aquifer-test data, isotopic dating of ground water, and water-quality data to be the process most responsible for reducing concentrations of highway deicers in the aquifer. Chemical analyses of the sand composing the aquifer indicated that cation exchange decreased the mass of deicerrelated sodium in ground water, although the sand has a limited capacity to sustain the process. Automated daily measurements of specific conductance, correlated to chloride concentrations, indicated that some deicer is retained in the aquifer near the highway throughout the entire year and acts as a continuous chloride source for ground water. Peak concentrations of deicerrelated constituents occasionally were detected by the daily, automated measurements of specific conductance that were made between the monthly samplings of ground water. Data analysis indicated that more frequent sampling than monthly intervals would be necessary if maximum chloride concentrations were to be measured. Some deicer may be retained in the aquifer and unsaturated zone between annual salt-application periods. Chloride concentrations at wells 1-DG-WT and 2-DG-WT remained greater than background through much or all of the year. The estimated masses of chloride transported in ground water past 2-DG in 1995 and 1996 were either slightly greater than (1995) or less than (1996) the masses of chloride applied to US–12 during the study.

Indiana↗

Hydrogeologic framework and geochemistry of the Edwards aquifer saline-water zone, south-central Texas

The Edwards aquifer supplies drinking water for more than 1 million people in south-central Texas. The saline-water zone of the Edwards aquifer extends from the downdip limit of freshwater to the southern and eastern edge of the Stuart City Formation. Water samples from 16 wells in the Edwards aquifer saline-water zone were collected during July&ndash;September 1990 and analyzed for major and minor dissolved constituents, selected stable isotopes, and radioisotopes. These data, supplemental data from an extensive water-quality data base, and data from other previous studies were interpreted to clarify the understanding of the saline-waterzone geochemistry. Most of the isotope and geochemical data indicate at least two distinct hydrological and geochemical regimes in the saline-water zone of the Edwards aquifer. On the basis of hydrogen and oxygen isotopes and radiocarbon data, the shallower updip regime is predominantly meteoric water that has been recharged probably from the freshwater zone within recent geologic time (less than tens of thousands of years). Also, on the basis of hydrogen and oxygen isotope data, water in the hydrologically stagnant regime (downdip) has been thermally altered in reactions with the carbonate rocks of the zone. The deeper water probably is much older than water in the shallow zone and is nearly stagnant relative to that in the shallow zone. The geochemical grouping observed in the wellwater data from well samples in the saline-water zone indicates that the zone is hydrologically compartmentalized, in part because of faults that function as barriers to downdip flow of recharge water. These fault barriers also probably impede updip flow. Flow compartmentalization and the resulting disparity in geochemistry between the two regimes indicate that updip movement of substantial amounts of saline water toward the freshwater zone is unlikely. Estimated in-place temperature of the samples collected indicates an increase with depth and (or) distance from the downdip limit of freshwater. The pH of the samples decreases with increasing distance from the downdip limit of freshwater, but the decrease is caused partly by the increase in temperature. Dissolved major ions and dissolved solids concentrations all indicate a progressive but monotonic increase in salinity from updip to downdip. The alkalinity of the water samples is predominantly bicarbonate because the low-molecular weight aliphatic-acid anion concentrations are small relative to the bicarbonate concentrations. The dissolved organic carbon concentrations also are lower than expected for an aquifer with economic amounts of oil and gas hydrocarbons.

Texas↗

Hydrogeologic and water-quality data from wells near the Hueco Bolson Recharge Project area, El Paso, Texas, 1990 and 1991

Tertiary-treated wastewater currently (1991) is being injected into the Hueco bolson aquifer at a site in northeastern El Paso, Texas, to supplement the quantity of available freshwater. Hydrologic data were compiled and water-quality and bacterial data were collected from existing wells near the Hueco Bolson Recharge Project (HBRP) in August and September 1990 and 1991. Borehole tracer tests indicated upward ground-water flow in nearly all tested intervals of several observation wells. The cumulative volume of injected water was less than the volume produced from wells adjacent to the HBRP area. Water levels in three production wells, located more than 1.5 miles from the injection wells, declined at rates comparable to those observed before injection operations. Water levels in wells located within 0.75 mile of the injection-well pipeline declined at a slower rate after HBRP injection operations had begun. Between 1985 and 1991, water levels in observation wells located within 700 feet of an injection well either did not appreciably decline, or declined at smaller rates than water levels in more distant production wells. Trihalomethane compounds were detected in water from 8 of the 16 observation and production wells sampled in 1990 and in 10 of the 17 wells sampled in 1991. Concentrations of trihalomethane compounds in these samples ranged from 0.05 to 1.9 |lg/L (micrograms per liter) in 1990 and from 0.05 to 1.4 |ig/L in 1991. Concentrations of trihalomethane compounds in samples of injected water from two wells were 27.8 and 34.6 |J,g/L respectively, in 1991. Dibromomethane and dichloromethane were detected in water from injection wells and from observation wells within about 700 feet of the injection wells. Aerobic bacteria were determined to be the only bacteria type present in ground water except for samples from two wells, which also contained denitrifying bacteria. The populations of aerobic bacteria determined in ground water ranged from 80 to more than 160,000 most probable number of organisms per milliliter of sample.

Texas↗

Relation of water chemistry of the Edwards aquifer to hydrogeology and land use, San Antonio Region, Texas

Water-chemistry data from the Edwards aquifer for 1976-85, consisting of nearly 1,500 chemical analyses from 280 wells and 3 springs, were used to statistically evaluate relations among ground-water chemistry, hydrogeology, and land use. Five land uses associated with sampled wells were classified on the basis of published information and field surveys. Four major subareas of the aquifer were defined to reflect the relative susceptibility of ground water to contamination originating from human activities using hydrogeologic and tritium data. Water from an agricultural area over the unconfined zone of the aquifer had the largest median concentration of nitrite plus nitrate. Large nitrite plus nitrate concentrations were spatially associated with large tritium concentrations and nitrogen isotopic ratios characteristic of streamflow recharge. Detections of fecal-coliform bacteria were associated mainly with water from wells completed in the unconfined zone. Most of the occurrences of tetrachloroethylene, l,2-(trans)-dichloroethylene, trichlorofluoromethane, 1,1,1-trichloroethane, and 2,4-D in ground water were associated with wells completed in the unconfined zone of the aquifer. Fatty acids detected in water from some wells may commonly be present naturally in ground water. The percentage of samples in which arsenic, barium, lead, and zinc were detected was similar among subareas; the samples were from the freshwater parts of the aquifer. Large lead and zinc concentrations were associated with volumes of pumpage less than 1,000 gallons. In general, the quality of ground water in the freshwater parts of the aquifer (north of the "bad-water" line) is suitable for all uses including human consumption. Two areas that are exceptions are: (1) Northeast of Garner Field in Uvalde, Texas, where PCE (tetrachloroethylene) has been detected in groundwater samples, and (2) north-central Bexar County near the former West Avenue landfill where PCE and benzene have been detected in ground-water samples. Concentrations of these organic compounds in water from many wells in the two areas exceed the maximum contaminant level for human consumption set by the U.S. Environmental Protection Agency.

Water-Resources Investigations Report↗