Search USGS⌕ Search

Geology topics

John H. Williams

Publications and source records attributed to John H. Williams.

At least 55 records · Page 3Linked to original sources

Integrated analysis of flow, temperature, and specific-conductance logs and depth-dependent water-quality samples from three deep wells in a fractured-sandstone aquifer, Ventura County, California

Analysis of flow, temperature, and specific-conductance logs and depth-dependent water-quality samples collected under ambient and pumped conditions provided a preliminary delineation of flow zones and water quality in three deep abandoned water-supply wells. The integrated analysis was completed as part of the characterization of a fractured-sandstone aquifer in the mountainous setting of the Santa Susana Field Laboratory in southern Ventura County, California. In the deepest well, which was 1,768 feet deep and had the highest specific capacity (120 gallons per minute per foot), flow zones were detected at 380 feet (base of casing) and at 440, 595, and 770 feet in the open hole. Under ambient conditions, measured flow was downward from the 380- and 440-foot zones to the 595- and 770-foot zones. Under pumped conditions, most of flow was contributed by the 595-foot zone. Flow from the 380- and 440-foot zones appeared to have lower specific conductance and higher trichloroethylene concentrations than that from the 595-foot zone. In the shallowest well, which was reportedly 940 feet deep but only logged to 915 feet due to blockage, flow zones were detected behind the perforated casing and at 867 feet in the open hole. Under ambient conditions, downward and upward flows appeared to exit at a zone behind the perforated casing at 708 feet. Most of the pumped flow was contributed from zones behind the perforated casing between 565 and 708 feet. Pumped flow also was contributed by zones at 867 feet and below the logged depth. Volatile organic compounds were not detected in the ambient and pumped flows. In the third well, which was 1,272 feet deep and had the lowest specific capacity (3.6 gallons per minute per foot), flow zones were detected in the open hole above and just below the water level near 337 feet and at 615, 785, 995, and 1,070 feet. Under ambient conditions, measured flow in well was downward from the shallowmost zones to the 995-foot zone. Fracture zones at 615, 785, and 995 feet each contributed about one-third of the pumped flow measured below the pump. Volatile organic compounds were not detected in the ambient and pumped flows.

California↗

Geophysical log analysis of selected test holes and wells in the High Plains Aquifer, Central Platte River Basin, Nebraska

The U.S. Geological Survey in cooperation with the Central Platte Natural Resources District is investigating the hydrostratigraphic framework of the High Plains aquifer in the Central Platte River basin. As part of this investigation, a comprehensive set of geophysical logs was collected from six test holes at three sites and analyzed to delineate the penetrated stratigraphic units and characterize their lithology and physical properties. Flow and fluid-property logs were collected from two wells at one of the sites and analyzed along with the other geophysical logs to determine the relative transmissivity of the High Plains aquifer units. The integrated log analysis indicated that the coarse-grained deposits of the alluvium and the upper part of the Ogallala Formation contributed more than 70 percent of the total transmissivity at this site. The lower part of the Ogallala with its moderately permeable sands and silts contributed some measureable transmissivity, as did the fine-grained sandstone of the underlying Arikaree Group, likely as a result of fractures and bedding-plane partings. Neither the lower nor the upper part of the siltstone- and claystone-dominated White River Group exhibited measurable transmissivity. The integrated analysis of the geophysical logs illustrated the utility of these methods in the detailed characterization of the hydrostratigraphy of the High Plains aquifer.

Nebraska↗

Flow-log analysis for hydraulic characterization of selected test wells at the Indian Point Energy Center, Buchanan, New York

Flow logs from 24 test wells were analyzed as part of the hydraulic characterization of the metamorphosed and fractured carbonate bedrock at the Indian Point Energy Center in Buchanan, New York. The flow logs were analyzed along with caliper, optical- and acoustic-televiewer, and fluid-resistivity and temperature logs to determine the character and distribution of fracture-flow zones and estimate their transmissivities and hydraulic heads. Many flow zones were associated with subhorizontal to shallow-dipping fractured zones, southeast-dipping bedding fractures, northwest-dipping conjugate fractures, or combinations of bedding and conjugate fractures. Flow-log analysis generally provided reasonable first-order estimates of flow-zone transmissivity and head differences compared with the results of conventional hydraulic-test analysis and measurements. Selected results of an aquifer test and a tracer test provided corroborating information in support of the flow-log analysis.

New York↗

Preliminary delineation of contaminated water-bearing fractures intersected by open-hole bedrock wells

Contaminated water‐bearing fractures intersected by open‐hole bedrock wells were preliminarily delineated through a combination of geophysical logging, vertical‐flow measurements, and downhole water sampling as part of remedial site investigations in southeastern New York. The wells investigated range from 100 to 450 feet in depth, have only shallow surface casing, and intersect multiple water‐bearing zones. The distribution of water‐bearing zones that intersect the wells was determined from single‐point resistance, caliper, fluid‐resistivity, temperature, and acoustic‐televiewer logs. Measurable flow in the wells was downward from upper producing zones to lower receiving zones that are poorly connected in the aquifer and that differ in hydraulic head as a result of nearby pumping. A down hole sampler was used to collect discrete and composite water samples for analysis of volatile organic compounds from producing zones that are self‐purging as a result of flow in the wells. The results obtained at two of the study sites are presented—the Spring Valley wellfield and the Mahopac business district. At the Spring Valley wellfield, a supply well completed in Mesozoic sandstone and conglomerate intersects water‐bearing zones at depths of 204 to 245 feet that produced contaminated water that was received by a zone at 278 feet. In the same well, a deeper zone at 345 feet produced uncontaminated water that was received by a zone at 403 feet. Correlation of information from the well, geophysical logs and drill cores from nearby monitoring wells, and bedrock outcrops indicates that most of the water‐bearing zones are bedding‐plane separations that probably provide pathways for contaminant transport in the bedrock aquifer for significant distances. In the Mahopac business district, a deep test well completed in Precambrian gneiss intersected shallow waterbearing zones at 50 to 79 feet that produced contaminated water that was received by deep zones at 260 and 328 feet. The water‐bearing zones consist of single or closely spaced multiple fractures with dips of 5 to 50 degrees. By analogy with the results from this test well, deep open‐hole wells in the area may serve as “short circuits” in the ground water flow system and allow direct transport of contaminants to deeper zones in the fractured‐bedrock aquifer. The methods presented can be used to investigate ground water flow and contamination in fractured‐bedrock aquifers in advance of more focused monitoring programs. The methods can be applied in existing open‐hole wells before test drilling and monitoring well installation to provide for efficient program design. The methods also can be used during the installation of monitoring wells to help determine completion depths and open intervals and to ensure that the wells are not serving as conduits for the flow of contaminated water.

New York↗

Application of electromagnetic logging to contamination investigations in glacial sand-and-gravel aquifers

Electromagnetic (EM) logging provides an efficient method for high‐resolution, vertical delineation of electrically conductive contamination in glacial sand‐and‐gravel aquifers. LM. gamma, and lithologic logs and specific conductance data from sand‐and‐gravel aquifers at five sites in the northeastern United States were analyzed to define the relation of KM conductivity to aquifer lithology and water quality. Municipal waste disposal, septic waste discharge, or highway deicing salt application at these sites has caused contaminant plumes in which the dissolved solids concentration and specific conductance of ground water exceed background levels by as much as 10 to 20 limes. The major hydrogeologic factors that affected KM log response at the five sites were the dissolved solids concentration of the ground water and the silt and clay content in the aquifer. KM conductivity of sand and gravel with uncontaminated water ranged from less than 5 to about 10 millisiemens per meter (mS/m); that of silt and clay zones ranged from about 15 to 45 mS/m: and that of the more highly contaminated zones in sand and gravel ranged from about 10 to more than 80 mS/m. Specific conductance of water samples from screened intervals in sand and gravel at selected monitoring well installations was significantly correlated with KM conductivity. CM logging can be used in glacial sand‐and‐gravel aquifer investigations to (1) determine optimum depths for the placement of monitoring well screens: (2) provide a nearly continuous vertical profile of specific conductance to complement depth‐specific water quality samples; and (3) identify temporal changes in water quality through sequential logging. Detailed lithologic or gamma logs, preferably both, need to be collected along with the F.M logs to define zones in which elevated EM conductivity is caused by the presence of sill and clay beds rather than contamination.

Connecticut, Massachusetts, New York, Vermont↗

Combined use of borehole geophysics and packers to site potable wells in a contaminated area in Montville, Connecticut

A leaking underground gasoline tank contaminated a crystalline bedrock aquifer in Montville, Connecticut, USA with MTBE and benzene. At the original residential bedrock supply wells, the median MTBE concentration was 165 micrograms per liter (mg/L), and the median benzene concentration was 320 mg/L. The maximum concentrations of MTBE and benzene were 4,300 mg/l and 1,700 mg/L, respectively. Because of the unavailability of a public water supply and the long-term expense of point-of-use (on-site) treatment systems, the Connecticut Department of Environmental Protection Leaking Underground Storage Tank Program considered drilling replacement wells for water supply, if suitable drill sites could be located. Borehole geophysical methods were used as part of the investigation to find suitable drill sites. The U.S. Geological Survey performed borehole radar logging in three of the most contaminated wells. Other geophysical logs were run in two of the wells to enhance the hydrogeological characterizations. These data, combined with straddle-packer testing provided by a drilling contractor, formed the basis of a conceptual model used in the search for discrete fractures with better water quality than provided by an open-hole sample. At Property A, a single transmissive fracture was identified at the bottom of the well. This well, although having historically lower gasoline concentrations than the other two wells, had persistent high iron bacteria fouling of the filtration system. By 2002, concentrations of MTBE and benzene had decreased to 59 and 3 mg/L, respectively, and the water was treatable except for the iron. Because no water-bearing fractures were encountered above the well bottom, an alternate well site was selected based on a set of vertical fractures observed in a nearby outcrop, rather than on the geophysical data. The new well, sited along the strike of these fractures, yielded 9 gallons per minute (gpm) but was found to be more contaminated than the original well. MTBE and benzene were detected at 224 and 7 mg/L, respectively. At Property B, the isolated fractures associated with four radar reflections contained MTBE in concentrations ranging from 460 to 680 mg/L, with concentration increasing with depth. A new well site was selected based upon topography and physical limitations of the property. A target drilling depth was selected to avoid encountering the most contaminated fracture, as projected from the radar data in the contaminated well. A new well, drilled to the target depth, yielded 2 gpm, which was sufficient for domestic supply. No contaminants were detected during 7 years of annual sampling. Over the next 2 years, MTBE was detected twice at 2 and 8 mg/L. At Property C, the isolated fractures associated with 12 radar reflections and acoustic televiewer images yielded MTBE concentrations ranging from 47 to 1,200 mg/L and benzene concentrations from 6 to 1,000 mg/L, with concentrations generally increasing with depth. A new well site was selected based upon physical limitations of the site. A target drilling depth was chosen to avoid encountering the most contaminated fractures, as projected from the radar data in the contaminated well. A new well, drilled to the target depth, yielded 6 gpm. MTBE was detected at concentrations ranging from trace levels to 12 mg/L for 6 years. Benzene was not detected. These case histories suggest that the combined use of borehole geophysics and discrete-fracture sampling can, in some cases, be used to predict the locations of less contaminated or uncontaminated fractures, at distances of tens of feet from contaminated bedrock wells. This information may be used to improve the chances of successfully siting alternate potable water wells. Likewise, the same data and approach potentially could be used for targeting specific fractures for remediation.

Connecticut↗

Geophysical, stratigraphic, and flow-zone logs of selected test, monitor, and water-supply wells in Cayuga County, New York

Volatile-organic compounds have been detected in water sampled from more than 50 supply wells between the City of Auburn and Village of Union Springs in Cayuga County, New York, and the area was declared a Superfund site in 2002. In 2001-04, geophysical logs were collected from 37 test, monitor, and water-supply wells as a preliminary part of the investigation of volatile-organic compound contamination in the carbonate-bedrock aquifer system. The geophysical logs included gamma, induction, caliper, wellbore image, deviation, fluid resistivity and temperature, and flowmeter. The geophysical logs were analyzed along with core samples and outcrops of the bedrock to define the stratigraphic units and flow zones penetrated by the wells. This report describes the logging methods used in the study and presents the geophysical, stratigraphic, and flow-zone logs.

Open-File Report↗

Hydraulic logging methods - A summary and field demonstration in Conyers, Rockdale County, Georgia

Geophysical surveying techniques provide important information for ground-water investigations (Zohdy and others, 1974; Keys, 1997; Haeni and others, 2001). Subsurface-geophysical methods are used to delineate and characterize hydraulically active zones; the extent of contamination, and contaminant sources; identify geologic features; optimize monitoring well placement; and guide remediation efforts. Borehole-geophysical methods provide information about the physical, chemical, and hydraulic properties of rock, sediments, and fluids in the subsurface and provide important information on subsurface bedrock structures including lithology, rock fabric, location, orientation, and hydraulic properties of fractures (Keys, 1990). Effective use of geophysical data requires that the data be interpreted in the context of known local and regional geology and hydrogeology. In addition, because of the complexity and heterogeneity of crystalline-rock aquifers, a suite of borehole geophysical methods is used to determine the location, extent, and nature of fractures and other structural features in the bedrock aquifer. The geophysical data from each borehole and method are analyzed together to provide an integrated interpretation, thereby reducing the ambiguity that can occur by interpreting each geophysical log individually (Shapiro and others, 1999). Previous work using borehole geophysics to characterize ground-water availability in crystalline rock aquifers includes Chapman and Lane (1996), Mack and others (1998), and Johnson and others (1999). Other investigations that focused on contamination in fractured-rock aquifers used geophysical methods to relate highly transmissive features to structural features in the bedrock (Hansen and Lane, 1995; and Lane and others, 2002).

Georgia↗

Characterization of fractures and flow zones in a contaminated shale at the Watervliet Arsenal, Albany County, New York

Flow zones in a fractured shale in and near a plume of volatile organic compounds at the Watervliet Arsenal in Albany County, N. Y. were characterized through the integrated analysis of geophysical logs and single- and cross-hole flow tests. Information on the fracture-flow network at the site was needed to design an effective groundwater monitoring system, estimate offsite contaminant migration, and evaluate potential containment and remedial actions. Four newly drilled coreholes and four older monitoring wells were logged and tested to define the distribution and orientation of fractures that intersected a combined total of 500 feet of open hole. Analysis of borehole-wall image logs obtained with acoustic and optical televiewers indicated 79 subhorizontal to steeply dipping fractures with a wide range of dip directions. Analysis of fluid resistivity, temperature, and heat-pulse and electromagnetic flowmeter logs obtained under ambient and short-term stressed conditions identified 14 flow zones, which consist of one to several fractures and whose estimated transmissivity values range from 0.1 to more than 250 feet squared per day. Cross-hole flow tests, which were used to characterize the hydraulic connection between fracture-flow zones intersected by the boreholes, entailed (1) injection into or extraction from boreholes that penetrated a single fracture-flow zone or whose zones were isolated by an inflatable packer, and (2) measurement of the transient response of water levels and flow in surrounding boreholes. Results indicate a wellconnected fracture network with an estimated transmissivity of 80 to 250 feet squared per day that extends for at least 200 feet across the site. This interconnected fracture-flow network greatly affects the hydrology of the site and has important implications for contaminant monitoring and remedial actions.

New York↗

Application of advanced geophysical logging methods in the characterization of a fractured-sedimentary bedrock aquifer, Ventura County, California

An integrated suite of advanced geophysical logging methods was used to characterize the geology and hydrology of three boreholes completed in fractured-sedimentary bedrock in Ventura County, California. The geophysical methods included caliper, gamma, electromagnetic induction, borehole deviation, optical and acoustic televiewer, borehole radar, fluid resistivity, temperature, and electromagnetic flowmeter. The geophysical logging 1) provided insights useful for the overall geohydrologic characterization of the bedrock and 2) enhanced the value of information collected by other methods from the boreholes including core-sample analysis, multiple-level monitoring, and packer testing. The logged boreholes, which have open intervals of 100 to 200 feet, penetrate a sequence of interbedded sandstone and mudstone with bedding striking 220 to 250 degrees and dipping 15 to 40 degrees to the northwest. Fractures intersected by the boreholes include fractures parallel to bedding and fractures with variable strike that dip moderately to steeply. Two to three flow zones were detected in each borehole. The flow zones consist of bedding-parallel or steeply dipping fractures or a combination of bedding-parallel fractures and moderately to steeply dipping fractures. About 75 to more than 90 percent of the measured flow under pumped conditions was produced by only one of the flow zones in each borehole.

California↗

Use of advanced borehole geophysical techniques to delineate fractured-rock ground-water flow and fractures along water-tunnel facilities in northern Queens County, New York

Advanced borehole geophysical methods were used to assess the geohydrology of crystalline bedrock along the course of a new water tunnel for New York City. The logging methods include natural gamma, spontaneous potential, single-point resistance, mechanical and acoustic caliper, focused electromagnetic induction, electromagnetic resistivity, magnetic susceptibility, borehole-fluid temperature and conductance, differential temperature, heat-pulse flowmeter, acoustic televiewer, borehole deviation, optical televiewer, and borehole radar. Integrated interpretation of the geophysical logs from an 825-foot borehole (1) provided information on the extent, orientation, and structure (foliation and fractures) within the entire borehole, including intensely fractured intervals from which core recovery may be poor; (2) delineated transmissive fracture zones intersected by the borehole and provided estimates of their transmissivity and hydraulic head; and (3) enabled mapping of the location and orientation of structures at distances as much as 100 ft from the borehole. Analyses of the borehole-wall image and the geophysical logs from the borehole on Crescent Street, in northern Queens County, are presented here to illustrate the application of the methods. The borehole penetrates gneiss and other crystalline bedrock that has predominantly southeastward dipping foliation and nearly horizontal and southeastward-dipping fractures. The heat-pulse flowmeter logs obtained under pumping and nonpumping conditions, together with the other geophysical logs, indicate five transmissive fracture zones. More than 90 percent of the open-hole transmissivity is associated with a fracture zone 272 feet BLS (below land surface). A transmissive zone at 787 feet BLS that consists of nearly parallel fractures lies within the projected tunnel path; here the hydraulic head is 12 to 15 feet lower than that of transmissive zones above the 315-foot depth. The 60-megahertz directional borehole radar logs indicate the location and orientation of two closely spaced radar reflectors that would intersect the projection of the borehole below its drilled depth. Subsequent excavation of the tunnel past the borehole allowed comparison of the log analysis with conditions observed in the tunnel. The tunnel was found to intersect gneiss with southeastward dipping foliation; many nearly horizontal fractures; and a southeastward dipping fracture zone whose location, character, and orientation was consistent with that of the mapped radar reflectors. The fracture zone produced inflow to the tunnel at a rate of 50 to 100 gallons per minute. All conditions indicated by the logging methods were consistent with those observed within the tunnel.

New York↗

Borehole-wall imaging with acoustic and optical televiewers for fractured-bedrock aquifer investigations

Imaging with acoustic and optical televiewers results in continuous and oriented 360 degree views of the borehole wall from which the character and orientation of lithologic and structural features can be defined for fractured-bedrock aquifer investigations. Fractures are more clearly defined under a wider range of conditions on acoustic images than on optical images including dark-colored rocks, cloudy borehole water, and coated borehole walls. However, optical images allow for the direct viewing of the character of and relation between lithology, fractures, foliation, and bedding. The most powerful approach is the combined application of acoustic and optical imaging with integrated interpretation. Borehole-wall imaging provides information useful for the collection and interpretation of flowmeter and other geophysical logs, core samples, and hydraulic and water-quality data from packer testing and monitoring.

Conference Paper↗

Design, operation, and data analysis for a wireline packer system in open boreholes, with field-test results from Belvidere, Illinois

A wireline-operated packer was designed for use with a standard geophysical logging system. The packer probe consists of a downhole packer inflated with water removed from the borehole by an in-line submersible pump, and a differential pressure transducer calibrated to measure the hydraulic-head difference between the zones above and below the packer. Analysis of the packer data is based on a numerical model that predicts the water levels above and below the packer for a given set of aquifer zones of specified hydraulic head and transmissivity. Various computations are used to indicate the sensitivity of the packer measurements to the hydraulic head and transmissivity contrasts between aquifer zones. The wireline-packer probe was field tested in a series of open-bedrock boreholes in Belvidere, Illinois, at a site where vertical hydraulic-head differences are produced in a horizontally stratified aquifer by water production from an underlying aquifer. Analysis of the wireline-packer data produced estimates of hydraulic-head gradient and aquifer-zone transmissivity consistent with results from straddle-packer hydraulic tests. However, the wireline-packer data also indicated that there are significant variations of vertical hydraulic gradient with depth, and that the gradient is sharply reversed near the bottom of the boreholes. This result is consistent with upward ambient flow measured on previous occasions near the bottom of these boreholes, and has important consequences for the monitoring of ground-water flow at the study site.

Illinois↗

Hydrogeology and groundwater quality of the glaciated valleys of Bradford, Tioga, and Potter Counties, Pennsylvania

The most important sources of groundwater in Bradford, Tioga, and Potter Counties are the stratified-drift aquifers. Saturated sand and gravel primarily of outwash origin forms extensive unconfined aquifers in the valleys. Outwash is underlain in most major valleys by silt, clay, and very fine sand of lacustrine origin that comprise extensive confining units. The lacustrine confining units locally exceed 100 feet in thickness. Confined aquifers of ice-contact sand and gravel are buried locally beneath the lacustrine deposits. Bedrock and till are the basal confining units of the stratifies-drift aquifer systems. Recharge to the stratified-drift aquifers if by direct infiltration of precipitation, tributary-stream infiltration, infiltration of unchanneled runoff at the valley walls, and groundwater inflow from the bedrock and till uplands. Valley areas underlain by superficial sand and gravel contribute about 1 million gallons per day per square mile of water from precipitation to the aquifers. Tributary streams provide recharge of nearly 590 gallons per day per foot of stream reach. Water is added at the rate of 1 million gallons per day per square mile of bordering uplands not drained by tributary streams to the stratified-drift aquifers from unchanneled runoff and groundwater inflow. Induced infiltration can be a major source of recharge to well fields completed in unconfined stratified-drift aquifers that are in good hydraulic connection with surface water. The well fields of an industrial site in North Towanda, a public-water supplier at Tioga Point, and the U.S. Fish and Wildlife Service at Asaph accounted for 75 percent of the 10.8 million gallons per day pf groundwater withdrawn by public suppliers and other selected users in 1985. The well fields tap stratified-drift aquifers that are substantially recharged by induced infiltration or tributary-stream infiltration. Specific-capacity data from 95 wells indicate that most wells completed in stratified-drift aquifers have specific capacities an order of magnitude greater than those completed in till and bedrock, Wells completed in unconfined stratified-drift aquifers and in bedrock aquifers have the highest and lowest median specific capacities -- 24 and 0.80 gallons per minute per foot of drawdown, respectively. Wells completed in confined stratified-drift aquifers and in till have median specific capacties of 11 and 0.87 gallons per minute per foot of drawdown, respectively. The results of 223 groundwater-quality analyses indicate two major hydrogeochemical zones: (1) a zone of unrestricted groundwater flow that contains water of the calcium bicarbonate type (this zone is found in almost all of the stratified-drift aquifers, till, and shallow bedrock systems); and (2) a zone of restricted groundwater slow that contains water of the sodium chloride type (this zone is found in the bedrock, and, in some areas, in till and confined stratified-drift aquifers). Samples pumped from wells that penetrate restricted-flow zones have median concentrations of total dissolved solids, dissolved chloride, and dissolved barium of 840 and 350 milligrams per liter, and 2,100 micrograms per liter, respectively. Excessive concentrations of iron and manganese are common in the groundwater of the study area; about 50 percent of the wells sampled contain water that has iron and manganese concentrations that exceed the U.S. Environmental Protection Agency secondary maximum contaminant levels of 300 and 50 micrograms per liter, respectively. Only water in the unconfined stratified-drift aquifers and the Catskill Formation has median concentrations lower than these limits.

Pennsylvania↗