Evaluation of a mass-balance approach to determine consumptive water use in northeastern Illinois

A principal component of evaluating and managing water use is consumptive use. This is the portion of water withdrawn for a particular use, such as residential, which is evaporated, transpired, incorporated into products or crops, consumed by humans or livestock, or otherwise removed from the immediate water environment. The amount of consumptive use may be estimated by a water (mass)-balance approach; however, because of the difficulty of obtaining necessary data, its application typically is restricted to the facility scale. The general governing mass-balance equation is: Consumptive use = Water supplied - Return flows . This study explored a mass-balance field-based computation of consumptive use in a residential setting at the scale of a sanitary sewer service area (sewershed). In addition, the feasibility (cost and difficulty) and relative uncertainties (accuracies) associated with applying the approach at this scale were evaluated. The study was conducted during 2011–13 within a 3.5-square mile (mi 2 ) sewershed confined to a predominantly residential area of Elk Grove Village, Illinois. Following background evaluation of the geohydrologic setting, sewershed infrastructure, and possible components of supplied and returned water, the identified primary components were 1. public water deliveries by the Elk Grove Village Department of Public Works, 2. self-served groundwater withdrawals in an included unincorporated neighborhood with public sanitary sewer service, 3. return flows to the sanitary sewer system, and 4. direct return of water discharged from swimming pools to Salt Creek. Water volumes principally were reported for deliveries, measured for sanitary sewer returns by using an acoustic Doppler current-velocity meter, and estimated for domestic withdrawals and swimming pool discharges to storm sewers. All water volumes required some degree of estimation. Observation wells were installed adjacent to sewer pipelines (lines) to determine the depth of the water table relative to that of the sewer lines and to collect water samples for detection of optical brighteners, as they are routinely discharged as clotheswashing waste to sanitary sewers. These data provided qualitative information on gains (inflow and infiltration) and losses (exfiltration) of sewer flow by pipe leakage, which might otherwise not be considered in the sewer flow return measurements. Hydrographs of sewer flow also were evaluated to identify and estimate storm-associated inputs to sewer flow. The volume of sanitary sewer return flow (778 million gallons per year [Mgal/yr]) was determined to substantially exceed the volume of supplied water (566 Mgal/yr), thus, for this study setting, voiding the utility of the applied mass-balance approach for estimating consumptive water use. Mass-balance components, including sanitary sewer flow and supplied-water use, were estimated within reasonable limits of uncertainty. Evidence of a water table that is typically shallower than the area’s sewer lines, yet is sometimes depressed near more deeply buried sewer lines, suggests groundwater infiltration into the sewers contributes to the excess volume of return flow. Technical obstacles and project resources precluded accurate quantification of infiltration volumes and other gains and losses to sanitary sewer flow. As estimated from various simplified methods, a minimum of 26 percent of return flow measured in the sanitary sewer represented groundwater infiltration and stormwater inflow; separately, about 2 percent of return flow was estimated as inflow. On the basis of the alternative winter base-rate method, consumptive use in the sewershed was estimated as 13 percent, which compares favorably with that used by the State of Illinois for Lake Michigan allocation accounting (10 percent) and other States and Canadian Provinces in the Great Lakes region (generally 10-15 percent). The study also provided other findings considered useful to studies of water use and to performance evaluation of sanitary sewer infrastructure. In urban residential settings, the comparatively small volumes of nonpublic sources of water (self-supplied) and direct (nonsanitary) return flow potentially can be ignored in the estimation of consumptive use. An acoustic Doppler current-velocity meter can be used in sanitary sewers to accurately measure discharge and reasonably estimate storm-associated inflows. Hourly to daily patterns of water use can be readily identified and quantified in the return flow record for the sanitary sewers. Relative volumes of infiltration gains (and exfiltration losses) can be substantial, even in sewer systems of communities making significant investments in system upgrades to limit sewer line leakage. Monitoring of optical brighteners in groundwater (and potentially in sanitary sewer flow) can provide a useful means of identifying probable leakage from (and to) sewer lines. Accurate quantification of gains and losses to sanitary sewer flow at the sewershed scale will require additional research effort and technical advances. Under ideal conditions, accurate quantification of consumptive use at the sewershed scale by the described mass-balance approach might be possible. Under most prevailing conditions, quantification likely would be more costly and time consuming than that of the present study, given the freely contributed technical support of the host community and relatively appropriate conditions of the study area. Essentials to quantification of consumptive use are a fully cooperative community, storm and sanitary sewers that are separate, and newer sewer infrastructure and (or) a robust program for limiting infiltration, exfiltration, and inflow.

Illinois↗

Evaluation of the potential for hysteresis in index-velocity ratings for the Chicago Sanitary and Ship Canal near Lemont, Illinois

The U.S. Geological Survey (USGS) is responsible for monitoring flows in the Chicago Sanitary and Ship Canal (CSSC) near Lemont, Illinois, as a part of the Lake Michigan Diversion Accounting overseen by the U.S. Army Corps of Engineers, Chicago District. Lake Michigan Diversion Accounting is mandated by a U.S. Supreme Court decree in order to monitor, and limit, the State of Illinois’ annual diversion of Great Lakes water through the manmade CSSC. Every 5 years, a technical review committee consisting of practicing engineers and academics reviews USGS streamgaging practices in the CSSC near Lemont, Illinois. The sixth technical review committee expressed concern that the index-velocity rating—the method used to estimate mean cross-sectional velocity from a measured index velocity—may be subject to hysteresis at this site because of the unique, unsteady hydraulics of the canal. Hysteresis in index-velocity ratings can occur at sites where the flow distribution in the channel varies significantly between the rising and falling limbs of the hydrograph for the same discharge. Presently, hysteresis in index-velocity ratings has been documented only in tidally affected sites. This report investigates whether hysteresis can occur at this nontidal site, and the conditions under which it is likely to occur, by using both a theoretical approach and a three-dimensional hydrodynamic model. The theoretical analysis investigated the conditions required for hysteresis in the index-velocity rating, and the modeling analysis focused on the effect of the timing of the inflows from the CSSC and the Cal-Sag Channel on the potential for hysteresis and whether highly resolved simulations of actual high-flow events show any evidence of hysteresis. Based on both a theoretical analysis using observed historical data and an analysis using a three-dimensional hydrodynamic model, there is no conclusive evidence for the existence of hysteresis in the index-velocity rating at the USGS streamgage on the CSSC near Lemont, Illinois. Although the theoretical analysis indicated the possibility of hysteresis at this site, the hydrodynamic conditions required to generate hysteresis are not present at this site based on historical data. Ongoing streamgaging practices at this site will use the information in this report and include periodic assessment of the index-velocity rating for any signs of hysteresis that might result from future changes to the operation of this manmade canal.

Illinois↗

Effect of temporal resolution on the accuracy of ADCP measurements

The application of acoustic Doppler current profilers (ADCP's) in river flow measurements is promoting a great deal of progress in hydrometry. ADCP's not only require shorter times to collect data than traditional current meters, but also allow streamflow measurements at sites where the use of conventional meters is either very expensive, unsafe, or simply not possible. Moreover, ADCP's seem to offer a means for collecting flow data with spatial and temporal resolutions that cannot be achieved with traditional current-meters. High-resolution data is essential to characterize the mean flow and turbulence structure of streams, which can in turn lead to a better understanding of the hydrodynamic and transport processes in rivers. However, to properly characterize the mean flow and turbulence intensities of stationary flows in natural turbulent boundary layers, velocities need to be sampled over a long-enough time span. The question then arises, how long should velocities be sampled in the flow field to achieve an adequate temporal resolution? Theoretically, since velocities cannot be sampled over an infinitely long time interval, the error due to finite integration time must be considered. This error can be estimated using the integral time scale. The integral time scale is not only a measure of the time interval over which a fluctuating function is correlated with itself but also a measure of the time span over which the function is dependent on itself. This time scale, however, is not a constant but varies spatially in the flow field. In this paper we present an analysis of the effect of the temporal resolution (sampling time span) on the accuracy of ADCP measurements based on the integral time scale. Single ping velocity profiles collected with frequencies of 1 Hz in the Chicago River at Columbus Drive using an uplooking 600 kHz ADCP are used in this analysis. The integral time scale at different depths is estimated based on the autocorrelation function of the velocity fluctuations and is used to evaluate the mean-square error as a function of the integration time. The implications of these errors in typical ADCP measurements for discharge estimates in natural streams are discussed. Copyright ASCE 2004.

Conference Paper↗

The role of the U.S. Geological Survey in Lake Michigan Diversion Accounting in Illinois, 1984-2010

The State of Illinois' annual withdrawl from Lake Michigan is limited by a U.S. Supreme Court decree. The U.S. Geological Survey (USGS) is responsible for monitoring flows in the Chicago area waterway system (CAWS) as part of the Lake Michigan Diversion Accounting (LMDA) overseen by the U.S. Army Corps of Engineers, Chicago District. Every five years, the USGS streamgage practices in the CAWS are reviewed by a committee of practicing engineers and academics to ensure that the best engineering practices are implemented in accordance with the U.S. Supreme Court decree and as part of LMDA. This report provides a perspective on the role of the USGS in LMDA from 1984 to 2010 including the responses to the review committees. Six technical review committees have been convened by the U.S. Corps of Engineers to evaluate the key components of LMDA especially the USGS streamgages within the CAWS. Any changes in streamgaging practices at CAWS gaging stations require detailed analysis to ensure the change will not adversely affect the ability of the USGS to accurately monitor flows.

Illinois↗

Comparison of index velocity measurements made with a horizontal acoustic Doppler current profiler

The State of Illinois' annual withdrawal from Lake Michigan is limited by a U.S. Supreme Court decree, and the U.S. Geological Survey (USGS) is responsible for monitoring flows in the Chicago Sanitary and Ship Canal (CSSC) near Lemont, Illinois as a part of the Lake Michigan Diversion Accounting overseen by the U.S. Army Corps of Engineers, Chicago District. Every 5 years, a technical review committee consisting of practicing engineers and academics is convened to review the U.S. Geological Survey's streamgage practices in the CSSC near Lemont, Illinois. The sixth technical review committee raised a number of questions concerning the flows and streamgage practices in the CSSC near Lemont and this report provides answers to many of those questions. In addition, it is the purpose of this report to examine the index velocity meters in use at Lemont and determine whether the acoustic velocity meter (AVM), which is now the primary index velocity meter, can be replaced by the horizontal acoustic Doppler current profiler (H-ADCP), which is currently the backup meter. Application of the AVM and H-ADCP to index velocity measurements in the CSSC near Lemont, Illinois, has produced good ratings to date. The site is well suited to index velocity measurements in spite of the large range of velocities and highly unsteady flows at the site. Flow variability arises from a range of sources: operation of the waterway through control structures, lockage-generated disturbances, commercial and recreational traffic, industrial withdrawals and discharges, natural inflows, seiches, and storm events. The influences of these factors on the index velocity measurements at Lemont is examined in detail in this report. Results of detailed data comparisons and flow analyses show that use of bank-mounted instrumentation such as the AVM and H-ADCP appears to be the best option for index velocity measurement in the CSSC near Lemont. Comparison of the rating curves for the AVM and H-ADCP demonstrates that the H-ADCP is a suitable replacement for the AVM as the primary index velocity meter in the CSSC near Lemont. A key component to Lake Michigan Diversion Accounting is the USGS gaging station on the CSSC near Lemont, Illinois. The importance of this gaging station in monitoring withdrawals from Lake Michigan has made it one of the most highly scrutinized gaging stations in the country. Any changes in streamgaging practices at this gaging station requires detailed analysis to ensure the change will not adversely affect the ability of the USGS to accurately monitor flows. This report provides a detailed analysis of the flow structure and index velocity measurements in the CSSC near Lemont, Illinois, to ensure that decisions regarding the future of this streamgage are made with the best possible understanding of the site and the characteristics of the flow.

Illinois↗

Control-structure ratings on the Chicago Sanitary and Ship Canal near Lockport, Illinois

The U.S. Army Corps of Engineers and the Metropolitan Water Reclamation District of Greater Chicago regulate flows through control structures along the Lake Michigan lakefront and the Chicago Sanitary and Ship Canal (CSSC) for Lake Michigan diversion accounting, flood control, sanitary, and navigation purposes. This report documents the measurement and computation of flow through the Lockport Controlling Works (LCW) and the Lockport Powerhouse. This analysis aided in evaluation of the ratings at both structures, and the development of new ratings at the controlling works. The LCW structure consists of seven 30-feet (ft) wide sluice gates and is used to divert water from the CSSC and into the Des Plaines River. The flow regimes for the sluice gate included both free and submerged weir. Forty and 491 flow values from U.S. Geological Survey streamflow-gaging stations were used to develop equations describing free- and submerged-weir flow, respectively, through the sluice gates. The equations were developed for canal headwater elevations ranging from -7.0 to -10.5 ft Chicago City Datum (CCD), and tailwater (Des Plaines River at Lockport) to headwater (CSSC-LCW-Base) ratios ranging from 0.31 to 0.66. The Lockport Powerhouse structure consists of nine 9-ft wide by 14-ft high sluice gates and two 10-ft diameter turbines. Both tailwater and no-tailwater effect flow regimes occurred during nine measurements. Also, the canal headwater elevations ranged from -2.74 to -8.45 ft CCD, and the gates were configured six different ways during the measurements.

Illinois↗

Computation and error analysis of discharge for the Lake Michigan Diversion Project in Illinois: 1997-99 water years

Acoustic velocity meters (AVM's) and acoustic Doppler current profilers (ADCP's) were used to measure streamflow at four streamflow-gaging stations in the Chicago River system. The streamflow data were used to compute discharge and to determine the uncertainty in the computed annual mean discharge at each station for the Lake Michigan Diversion Project in Illinois. Descriptions of the instrumentation at each station, stage-area and index-velocity ratings, and methods utilized for computing discharge and estimating missing record are given. Daily mean and annual mean discharges were computed for each station for 1997-99 water years (WY's). A water year is defined as the 12-month period from October 1 through September 30. The water year is designated by the calendar year in which it ends and which includes 9 of the 12 months. Thus, the year ending September 30, 1999, is called the 1999 water year. A first-order error analysis was applied to acoustic velocity meter (AVM) data, stage-area, and index-velocity ratings at each streamflow-gaging station. The error analysis results indicate that the uncertainty is sensitive to the value of uncertainty associated with acoustic Doppler cur-rent profiler (ADCP) discharge measurement data. At the Chicago River at Columbus Drive at Chicago, Illinois station for the 1997-99 WY's, the uncertainty, expressed as a standard deviation of the average annual discharge, ranged from 13 to 18 cubic feet per second (ft3/s) when ADCP uncertainty was not included, whereas total uncertainty ranged from 55 to 69 ft3/s when ADCP uncertainty was included. At the Chicago Sanitary and Ship Canal at Romeoville, Illinois station for the 1997-99 WY's, the uncertainty ranged from 18 to 20 ft3/s when ADCP uncertainty was not included, whereas it ranged from 64 to 68 ft3/s when it was included. At the Calumet River below O'Brien Lock and Dam at Chicago, Illinois station for the 1997-99 WY's, the uncertainty ranged from 13 to 22 ft3/s when ADCP uncertainty was not included, whereas it ranged from 35 to 53 ft3/s when it was included. At the North Shore Channel at Wilmette, Illinois station for the 1997-99 WY's, when the record was entirely estimated, the uncertainty ranged from 8 to 12 ft3/s when the ADCP uncertainty was not included, and from 16 to 17 ft3/s when it was included. For the 2000 WY, the estimated uncertainty was 8.6 ft3/s when ADCP uncertainty is not included and 12.5 ft3/s when ADCP uncertainty was included.

Illinois↗

Comparison of estimates of uncertainty of discharge at US geological survey index-velocity gages on the Chicago sanitary and ship canal, Illinois

Estimates of uncertainty of discharge at time scales from 5 minutes to 1 year were obtained for two index-velocity gages on the Chicago Sanitary and Ship Canal (CSSC), Ill., instrumented with acoustic velocity meters (AVMs). The velocity measurements obtained from the AVMs are corrected to a mean channel velocity by use of an index velocity rating (IVR). The IVR is a regression-derived relation between the AVM velocity estimates and those obtained using acoustic Doppler current profilers (ADCPs). The uncertainty estimation method is based on the first-order variance method, but the AVM velocity error is estimated from an empirical perspective, using the statistics of the IVR regression. Some uncertainty exists regarding whether to include the standard error of the IVR regression (????2) in the discharge uncertainty. At the 5-minute time scale when ?? ??2 is included, it has the dominant contribution to the discharge uncertainty, and the discharge uncertainty (expressed as the standard deviation of the discharge estimate) is about 5 m3/s at one gage and 8 m3/s at the other, independent of discharge. When ????2 is not included, the discharge uncertainty at the 5-minute time scale is much smaller (about 0.5 m3/s) and depends more strongly on discharge. For time scales one day or greater and when ????2 is not included, the uncertainty of the IVR parameters dominates the discharge uncertainty. The value of the discharge uncertainty is about 0.4 m3/s for one gage and 0.5 m3/s for the other gage at long time scales.

Conference Paper↗

Measurement of velocities with an acoustic velocity meter, one side-looking and two upward-looking acoustic Doppler current profilers in the Chicago Sanitary and Ship Canal, Romeoville, Illinois

In 1998, a prototype 300 kHz, side-looking Acoustic Doppler Current Profiler (ADCP) was deployed in the Chicago Sanitary and Ship Canal (CSSC) at Romeoville, Illinois. Additionally, two upward-looking ADCP's were deployed in the same acoustic path as the side-looking ADCP and in the reach defined by the upstream and downstream acoustic velocity meter (AVM) paths. All three ADCP's were synchronized to the AVM clock at the gaging station so that data were sampled simultaneously. The three ADCP's were deployed for six weeks measuring flow velocities from 0.0 to 2.5 ft/s. Velocities measured by each ADCP were compared to AVM path velocities and to velocities measured by the other ADCP's.

Proceedings of the IEEE Working Conference on Curr↗

Rainfall in and near Du Page County, Illinois, October 1991-September 1995

Twenty-four hour rainfall data are presented for 11 rain gages in and near Du Page County, Illinois. Daily rainfall totals were recorded from October 1, 1991, to September 30, 1995. Station descriptions include site identifiers, locations, drainage basins, types of instrumentation, accuracy, and periods of record. Missing and partial rainfall data, and precipitation totals affected by snowfall have been noted for the periods of record.

Open-File Report↗

Regional rainfall-runoff relations for simulation of streamflow for watersheds in Du Page County, Illinois

Rainfall and streamflow data collected from July 1986 through September 1993 were utilized to calibrate and verify a continuous-simulation rainfall-runoff model for three watersheds (11.8--18.0 square miles in area) in Du Page County. Classification of land cover into three categories of pervious (grassland, forest/wetland, and agricultural land) and one category of impervious subareas was sufficient to accurately simulate the rainfall-runoff relations for the three watersheds. Regional parameter sets were obtained by calibrating jointly all parameters except fraction of ground-water inflow that goes to inactive ground water (DEEPFR), interflow recession constant (IRC), and infiltration (INFILT) for runoff from all three watersheds. DEEPFR and IRC varied among the watersheds because of physical differences among the watersheds. Two values of INFILT were obtained: one representing the rainfall-runoff process on the silty and clayey soils on the uplands and lake plains that characterize Sawmill Creek, St. Joseph Creek, and eastern Du Page County; and one representing the rainfall-runoff process on the silty soils on uplands that characterize Kress Creek and parts of western Du Page County. Regional rainfall-runoff relations, defined through joint calibration of the rainfall-runoff model and verified for independent periods, presented in this report, allow estimation of runoff for watersheds in Du Page County with an error in the total water balance less than 4.0 percent; an average absolute error in the annual-flow estimates of 17.1 percent with the error rarely exceeding 25 percent for annual flows; and correlation coefficients and coefficients of model-fit efficiency for monthly flows of at least 87 and 76 percent, respectively. Close reproduction of the runoff-volume duration curves was obtained. A frequency analysis of storm-runoff volume indicates a tendency of the model to undersimulate large storms, which may result from underestimation of the amount of impervious land cover in the watershed and errors in measuring rainfall for convective storms. Overall, the results of regional calibration and verification of the rainfall-runoff model indicate the simulated rainfall-runoff relations are adequate for stormwater-management planning and design for watersheds in Du Page County.

Water-Resources Investigations Report↗

Regional rainfall-runoff relations for simulation of streamflow for watersheds in Lake County, Illinois

Rainfall and streamflow data collected in Lake County, Ill., from March 1990 through September 1993 were used to (1) calibrate a rainfall-runoff model for an area encompassing three watersheds (individual areas of 17.2, 35.7, and 37.0 mi 2 (square miles) and (2) verify the regional model parameter set obtained from the calibration by applying the parameter set to rainfall-runoff models for an additional small (6.3 mi 2 ) watershed and a large (59.6 mi 2 ) watershed. In addition, rainfall and streamflow data collected from April 1991 through September 1993 were used to calibrate the rainfall-runoff model for three single land-use watersheds (38.2-305 acres), called hydrologic response units (HRU's). Significant differences were found between the best parameters used in the HRU models and in the larger watershed models. The main channels in the HRU's are intermittent streams; thus, the parameters in the HRU models were selected such that a fluctuating water table could be simulated; runoff from the larger watersheds is not as sensitive to the effects of a fluctuating water table. Classification of land cover into two pervious subareas (forest and grass) and one impervious subarea (including parking lots, streets, and rooftops, among others) was sufficient to simulate the rainfall-runoff relations for all watersheds accurately. The model parameters presented in this report, which were refined through regional calibration and verified for watersheds not considered in the calibration, allow simulation of runoff in watersheds in Lake County, Ill., with approximately 93-percent accuracy in the total water balance, an average absolute error in the annual- flow estimates of 10.9 percent (and an error rarely exceeding 25 percent for annual flow), and monthly water balances with correlation coefficients of 93 percent and coefficients of model-fit efficiency of 86 percent. The models closely reproduced the partial-duration series of runoff and storm-runoff frequencies for the modeled watersheds.

Illinois↗

Rainfall in and near Lake County, Illinois, December 1989-September 1993

Rainfall quantity data for 23 rainfall-gaging stations located in and near Lake County, Ill., are presented. The rainfall data were collected from December 1989 through September 1993 as part of an on-going rainfall-runoff investigation. Station descriptions identify the location of and equipment installed at each rainfall-gaging station. Total daily rainfall is tabulated for each rainfall-gaging station for each water year. Periods of missing record and snow-affected precipitation totals are identified. The data are presented graphically using annual hyetographs and mass plots.

Open-File Report↗

Rainfall in and near Du Page County, Illinois, February 1986-September 1991

Rainfall for 14 rainfall-gaging stations located in and near Du Page County, Illinois, are presented. The rainfall data were collected from February 1986 through September 1991 as part of an on-going cooperative rainfall-runoff investigation. Station descriptions identify the location of and equpiment installed at each rainfall-gaging station. Total daily rainfall is tabulated for each rainfall-gaging staion for each water year. Periods of missing record and snow-affected precipitation totals are identified.

Open-File Report↗