Search USGSSearch

Geology topics

Gerard Olack

Publications and source records attributed to Gerard Olack.

2 recordsLinked to original sources

New biotite and muscovite isotopic reference materials, USGS57 and USGS58, for δ2H measurements–A replacement for NBS 30

The advent of continuous-flow isotope-ratio mass spectrometry (CF-IRMS) coupled with a high temperature conversion (HTC) system enabled faster, more cost effective, and more precise δ 2 H analysis of hydrogen-bearing solids. Accurate hydrogen isotopic analysis by on-line or off-line techniques requires appropriate isotopic reference materials (RMs). A strategy of two-point calibrations spanning δ 2 H range of the unknowns using two RMs is recommended. Unfortunately, the supply of the previously widely used isotopic RM, NBS 30 biotite, is exhausted. In addition, recent measurements have shown that the determination of δ 2 H values of NBS 30 biotite on the VSMOW-SLAP isotope-delta scale by on-line HTC systems with CF-IRMS may be unreliable because hydrogen in this biotite may not be converted quantitatively to molecular hydrogen. The δ 2 H VSMOW-SLAP values of NBS 30 biotite analyzed by on-line HTC systems can be as much as 21 mUr (or ‰) too positive compared to the accepted value of − 65.7 mUr, determined by only a few conventional off-line measurements. To ensure accurate and traceable on-line hydrogen isotope-ratio determinations in mineral samples, we here propose two isotopically homogeneous, hydrous mineral RMs with well-characterized isotope-ratio values, which are urgently needed. The U.S. Geological Survey (USGS) has prepared two such RMs, USGS57 biotite and USGS58 muscovite. The δ 2 H values were determined by both glassy carbon-based on-line conversion and chromium-based on-line conversion, and results were confirmed by off-line conversion. The quantitative conversion of hydrogen from the two RMs using the on-line HTC method was carefully evaluated in this study. The isotopic compositions of these new RMs with 1-σ uncertainties and mass fractions of hydrogen are: USGS57 (biotite) δ 2 H VSMOW-SLAP = − 91.5 ± 2.4 mUr ( n = 24) Mass fraction hydrogen = 0.416 ± 0.002% ( n = 4) Mass fraction water = 3.74 ± 0.02% ( n = 4) USGS58 (muscovite) δ 2 H VSMOW-SLAP = − 28.4 ± 1.6 mUr ( n = 24) Mass fraction hydrogen = 0.448 ± 0.002% ( n = 4) Mass fraction water = 4.03 ± 0.02% ( n = 4). These δ 2 H VSMOW-SLAP values encompass typical ranges for solid unknowns of crustal and mantle origin and are available to users for recommended two-point calibration.

Chemical Geology

Caution on the use of NBS 30 biotite for hydrogen-isotope measurements with on-line high-temperature conversion systems

RATIONALE The supply of NBS 30 biotite is nearly exhausted. During measurements of NBS 30 and potential replacements, reproducible δ 2 H VSMOW-SLAP values could not be obtained by three laboratories using high-temperature conversion (HTC) systems. The cause of this issue has been investigated using the silver-tube technique for hydrogen-isotope measurements of water. METHODS The δ 2 H VSMOW-SLAP values of NBS 30 biotite, other biotites, muscovites, and kaolinite with different particle sizes, along with IAEA-CH-7 polyethylene, and reference waters and NBS 22 oil that were sealed in silver-tube segments, were measured. The effect of absorbed water on mineral surfaces was investigated with waters both enriched and depleted in 2 H. The quantitative conversion of hydrogen from biotite into gaseous hydrogen as a function of mass and particle size was also investigated. RESULTS The δ 2 H VSMOW-SLAP values of NBS 30 obtained by three laboratories were as much as 21 ‰ too high compared with the accepted value of −65.7 ‰, determined by conventional off-line measurements. The experiments showed a strong correlation between grain size and the δ 2 H VSMOW-SLAP value of NBS 30 biotite, but not of biotites with lower iron content. The δ 2 H VSMOW-SLAP values of NBS 30 as a function of particle size show a clear trend toward −65.7 ‰ with finer grain size. CONCLUSIONS Determination of the δ 2 H VSMOW-SLAP values of hydrous minerals and of NBS 30 biotite by on-line HTC systems coupled to isotope-ratio mass spectrometers may be unreliable because hydrogen in this biotite may not be converted quantitatively into molecular hydrogen. Extreme caution in the use and interpretation of δ 2 H VSMOW-SLAP on-line measurements of hydrous minerals is recommended.

Rapid Communications in Mass Spectrometry