Search USGS⌕ Search

SEARCH · Search USGS

Results for “Sensor Review”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Comparing electronic probes for volumetric water content of low-density feathermoss

Purpose - Feathermoss is ubiquitous in the boreal forest and across various land-cover types of the arctic and subarctic. A variety of affordable commercial sensors for soil moisture content measurement have recently become available and are in use in such regions, often in conjunction with fire-susceptibility or ecological studies. Few come supplied with calibrations suitable or suggested for soils high in organics. Aims to test seven of these sensors for use in feathermoss, seeking calibrations between sensor output and volumetric water content. Design/methodology/approach - Measurements from seven sensors installed in live, dead and burned feathermoss samples, drying in a controlled manner, were compared to moisture content measurements. Empirical calibrations of sensor output to water content were determined. Findings - Almost all of the sensors tested were suitable for measuring the moss sample water content, and a unique calibration for each sensor for this material is presented. Differences in sensor design lead to changes in sensitivity as a function of volumetric water content, affecting the spatial averaging over the soil measurement volume. Research limitations/implications - The wide range of electromagnetic sensors available include frequency and time domain designs with variations in wave guide and sensor geometry, the location of sensor electronics and operating frequency. Practical implications - This study provides information for extending the use of electromagnetic sensors to feathermoss. Originality/value - A comparison of volumetric water content sensor mechanics and design is of general interest to researchers measuring soil water content. In particular, researchers working in wetlands, boreal forests and tundra regions will be able to apply these results. ?? Emerald Group Publishing Limited.

Sensor Review↗

Urban heat island and its regional impacts using remotely sensed thermal data – A review of recent developments and methodology

Many novel research algorithms have been developed to analyze urban heat island (UHI) and UHI regional impacts (UHIRIP) with remotely sensed thermal data tables. We present a comprehensive review of some important aspects of UHI and UHIRIP studies that use remotely sensed thermal data, including concepts, datasets, methodologies, and applications. We focus on reviewing progress on multi-sensor image selection, preprocessing, computing, gap filling, image fusion, deep learning, and developing new metrics. This literature review shows that new satellite sensors and valuable methods have been developed for calculating land surface temperature (LST) and UHI intensity, and for assessing UHIRIP. Additionally, some of the limitations of using remotely sensed data to analyze the LST, UHI, and UHI intensity are discussed. Finally, we review a variety of applications in UHI and UHIRIP analyses. The assimilation of time-series remotely sensed data with the application of data fusion, gap filling models, and deep learning using the Google Cloud platform and Google Earth Engine platform also has the potential to improve the estimation accuracy of change patterns of UHI and UHIRIP over long time periods.

Land↗

On the terminology of the spectral vegetation index (NIR – SWIR)/(NIR + SWIR)

The spectral vegetation index (ρNIR – ρSWIR)/(ρNIR + ρSWIR), where ρNIR and ρSWIR are the near-infrared (NIR) and shortwave-infrared (SWIR) reflectances, respectively, has been widely used to indicate vegetation moisture condition. This index has multiple names in the literature, including infrared index (II), normalized difference infrared index (NDII), normalized difference water index (NDWI), normalized difference moisture index (NDMI), land surface water index (LSWI), and normalized burn ratio (NBR), etc. After reviewing each term’s definition, associated sensors, and channel specifications, we found that the index consists of three variants, differing only in the SWIR region (1.2–1.3 µm, 1.55–1.75 µm, or 2.05–2.45 µm). Thus, three terms are sufficient to represent these three SWIR variants; other names are redundant and therefore unnecessary. Considering the spectral representativeness, the term’s popularity, and the “rule of priority” in scientific nomenclature, NDWI, NDII, and NBR, each corresponding to the three SWIR regions, are more preferable terms.

International Journal of Remote Sensing↗

Was the 18 May 1980 lateral blast at Mt St Helens the product of two explosions?

The 18 May 1980 lateral blast at Mt St Helens has been interpreted as the product of a single explosion by some stratigraphers and as two closely spaced explosions by others. The stratigraphic evidence that bears on this question is inconclusive; strata change dramatically over short distances and this complexity provides wide latitude for interpretation. Some independent non-stratigraphic evidence, however, suggests that the blast was the product of two explosions or clusters of explosions. The independent evidence comes from eyewitness accounts and photographs, from satellite sensors, and from seismic records. This paper reviews the pertinent evidence, offers a new interpretation, and concludes that the blast was indeed the product of two explosions or clusters of explosions.

Washington↗

Guidelines and standard procedures for high-frequency groundwater-quality monitoring stations—Design, operation, and record computation

High-frequency water-quality monitoring stations measure and transmit data, often in near real-time, from a wide range of aquatic environments to assess the quality of the Nation’s water resources. Common instrumentation for high-frequency water-quality data collection uses a multi-parameter sonde, which typically has sensors that measure and record water temperature, specific conductance, pH, and dissolved oxygen. Nitrate, turbidity, and fluorescent dissolved organic matter can also be monitored at high frequency. High-frequency groundwater-quality monitoring stations provide high-resolution time-series data to improve understanding of the timing of water-quality changes in the subsurface, especially for aquifer systems with short groundwater-residence times. High-frequency time-series data are used to monitor surface-water to groundwater interaction, quantify contaminant transport rates, and study water-quality variability in relation to variability of precipitation and groundwater pumping rates. High-frequency monitoring for contaminants or their surrogates have the added benefit of providing an early warning to protect valuable or sensitive aquifer resources. High-frequency time-series data also reveal short-term trends in groundwater quality, which may not be identifiable from monthly or annual sampling programs which facilitate the interpretation of decadal conditions. Systematic application of water-quality sonde operational procedures and a standard record-computation process are part of the required quality assurance for producing and documenting complete and accurate high-frequency groundwater-quality monitoring records. To collect quality high-frequency groundwater times-series data, water-quality sondes and sensors require careful field operation, cleaning, and calibration, as well as specific procedures for data computation, evaluation, review, and publication of final records. This report provides guidelines for the use of water-quality sondes and sensors for high-frequency groundwater-quality monitoring and updates the guidance pertaining to standardized records computation procedures for a wide range of groundwater environments. This report builds on previous continuous surface-water-quality monitoring guidance documentation for water temperature, specific conductance, pH, dissolved oxygen, and nitrate. The specific groundwater-quality monitoring guidelines presented in this report address station selection, design, installation, and operations; sonde and sensor inspections and cleaning and calibration methods; troubleshooting procedures; data evaluations, data corrections, and record computations; and record review, approval, and auditing procedures for the groundwater environment.

Techniques and Methods↗

Remote sensing sensors and applications in environmental resources mapping and modeling

The history of remote sensing and development of different sensors for environmental and natural resources mapping and data acquisition is reviewed and reported. Application examples in urban studies, hydrological modeling such as land-cover and floodplain mapping, fractional vegetation cover and impervious surface area mapping, surface energy flux and micro-topography correlation studies is discussed. The review also discusses the use of remotely sensed-based rainfall and potential evapotranspiration for estimating crop water requirement satisfaction index and hence provides early warning information for growers. The review is not an exhaustive application of the remote sensing techniques rather a summary of some important applications in environmental studies and modeling.

Sensors↗

Guidelines and standard procedures for continuous water-quality monitors: Site selection, field operation, calibration, record computation, and reporting

The U.S. Geological Survey uses continuous water-quality monitors to assess variations in the quality of the Nation's surface water. A common system configuration for data collection is the four-parameter water-quality monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data, although systems can be configured to measure other properties such as turbidity or chlorophyll. The sensors that are used to measure these water properties require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. Data from sensors can be used in conjunction with collected samples and chemical analyses to estimate chemical loads. This report provides guidelines for site-selection considerations, sensor test methods, field procedures, error correction, data computation, and review and publication processes. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.

Water-Resources Investigations Report↗

Global positioning system and associated technologies in animal behaviour and ecological research

Biologists can equip animals with global positioning system (GPS) technology to obtain accurate (less than or equal to 30 m) locations that can be combined with sensor data to study animal behaviour and ecology. We provide the background of GPS techniques that have been used to gather data for wildlife studies. We review how GPS has been integrated into functional systems with data storage, data transfer, power supplies, packaging and sensor technologies to collect temperature, activity, proximity and mortality data from terrestrial species and birds. GPS 'rapid fixing' technologies combined with sensors provide location, dive frequency and duration profiles, and underwater acoustic information for the study of marine species. We examine how these rapid fixing technologies may be applied to terrestrial and avian applications. We discuss positional data quality and the capability for high-frequency sampling associated with GPS locations. We present alternatives for storing and retrieving data by using dataloggers (biologging), radio-frequency download systems (e.g. very high frequency, spread spectrum), integration of GPS with other satellite systems (e.g. Argos, Globalstar) and potential new data recovery technologies (e.g. network nodes). GPS is one component among many rapidly evolving technologies. Therefore, we recommend that users and suppliers interact to ensure the availability of appropriate equipment to meet animal research objectives.

Philosophical Transactions of the Royal Society B:↗

Applications of unoccupied aerial systems (UAS) in landscape ecology: A review of recent research, challenges and emerging opportunities

Context Unoccupied aerial systems/vehicles (UAS/UAV, a.k.a. drones) have become an increasingly popular tool for ecological research. But much of the recent research is concerned with developing mapping and detection approaches, with few studies attempting to link UAS data to ecosystem processes and function. Landscape ecologists have long used high resolution imagery and spatial analyses to address ecological questions and are therefore uniquely positioned to advance UAS research for ecological applications. Objectives The review objectives are to: (1) provide background on how UAS are used in landscape ecological studies, (2) identify major advancements and research gaps, and (3) discuss ways to better facilitate the use of UAS in landscape ecology research. Methods We conducted a systematic review based on PRISMA guidelines using key search terms that are unique to landscape ecology research. We reviewed only papers that applied UAS data to investigate questions about ecological patterns, processes, or function. Results We summarize metadata from 161 papers that fit our review criteria. We highlight and discuss major research themes and applications, sensors and data collection techniques, image processing, feature extraction and spatial analysis, image fusion and satellite scaling, and open data and software. Conclusion We observed a diversity of UAS methods, applications, and creative spatial modeling and analysis approaches. Key aspects of UAS research in landscape ecology include modeling wildlife micro-habitats, scaling of ecosystem functions, landscape and geomorphic change detection, integrating UAS with historical aerial and satellite imagery, and novel applications of spatial statistics.

Landscape Ecology↗

Ambient field seismology in critical zone hydrological sciences

Passive ambient noise monitoring is an emerging tool in environmental seismology, leveraging the ambient seismic field to assess temporal variations in shallow subsurface properties. This review focuses on the potential and challenges of using scattered coda waves from noise correlation functions to monitor critical zone dynamics. The sensitivity of seismic velocities to various environmental factors, including precipitation, snowmelt, atmospheric pressure, and groundwater fluctuations, underscores the method’s versatility. While coda waves excel in detecting subtle changes due to their scattered nature, ballistic waves provide higher spatial resolution, albeit with challenges in source stability. Advances in seismic sensing, including distributed acoustic sensing and low-cost geophone networks, have enabled high-resolution monitoring of hydrological processes, subsurface deformation, and seismic hazards. Integrating seismic data with hydrological models provides insights into water storage, pore pressure changes, and soil moisture dynamics. However, limitations in spatial resolution, calibration with ground truth data, and coupled effects between environmental factors remain key challenges. This review emphasizes the importance of interdisciplinary approaches in refining methodologies, enhancing sensor deployments, and addressing data gaps. Passive seismic monitoring offers opportunities to understand critical zone processes and their broader impacts on seismic hazards and environmental sustainability.

Comptes Rendus. Géoscience↗

Using diurnal temperature signals to infer vertical groundwater-surface water exchange

Heat is a powerful tracer to quantify fluid exchange between surface water and groundwater. Temperature time series can be used to estimate pore water fluid flux, and techniques can be employed to extend these estimates to produce detailed plan-view flux maps. Key advantages of heat tracing include cost-effective sensors and ease of data collection and interpretation, without the need for expensive and time-consuming laboratory analyses or induced tracers. While the collection of temperature data in saturated sediments is relatively straightforward, several factors influence the reliability of flux estimates that are based on time series analysis (diurnal signals) of recorded temperatures. Sensor resolution and deployment are particularly important in obtaining robust flux estimates in upwelling conditions. Also, processing temperature time series data involves a sequence of complex steps, including filtering temperature signals, selection of appropriate thermal parameters, and selection of the optimal analytical solution for modeling. This review provides a synthesis of heat tracing using diurnal temperature oscillations, including details on optimal sensor selection and deployment, data processing, model parameterization, and an overview of computing tools available. Recent advances in diurnal temperature methods also provide the opportunity to determine local saturated thermal diffusivity, which can improve the accuracy of fluid flux modeling and sensor spacing, which is related to streambed scour and deposition. These parameters can also be used to determine the reliability of flux estimates from the use of heat as a tracer.

Groundwater↗

Experimental design and quality assurance: in situ fluorescence instrumentation

Both instrument design and capabilities of fluorescence spectroscopy have greatly advanced over the last several decades. Advancements include solid-state excitation sources, integration of fiber optic technology, highly sensitive multichannel detectors, rapid-scan monochromators, sensitive spectral correction techniques, and improve data manipulation software (Christian et al., 1981, Lochmuller and Saavedra, 1986; Cabniss and Shuman, 1987; Lakowicz, 2006; Hudson et al., 2007). The cumulative effect of these improvements have pushed the limits and expanded the application of fluorescence techniques to numerous scientific research fields. One of the more powerful advancements is the ability to obtain in situ fluorescence measurements of natural waters (Moore, 1994). The development of submersible fluorescence instruments has been made possible by component miniaturization and power reduction including advances in light sources technologies (light-emitting diodes, xenon lamps, ultraviolet [UV] lasers) and the compatible integration of new optical instruments with various sampling platforms (Twardowski et at., 2005 and references therein). The development of robust field sensors skirt the need for cumbersome and or time-consuming filtration techniques, the potential artifacts associated with sample storage, and coarse sampling designs by increasing spatiotemporal resolution (Chen, 1999; Robinson and Glenn, 1999). The ability to obtain rapid, high-quality, highly sensitive measurements over steep gradients has revolutionized investigations of dissolved organic matter (DOM) optical properties, thereby enabling researchers to address novel biogeochemical questions regarding colored or chromophoric DOM (CDOM). This chapter is dedicated to the origin, design, calibration, and use of in situ field fluorometers. It will serve as a review of considerations to be accounted for during the operation of fluorescence field sensors and call attention to areas of concern when making this type of measurement. Attention is also given to ways in which in-water fluorescence measurements have revolutionized biogeochemical studies of CDOM and how those measurements can be used in conjunction with remotely sense satellite data to understand better the biogeochemistry of DOM in aquatic environments.

Book chapter↗

Ad hoc instrumentation methods in ecological studies produce highly biased temperature measurements

In light of global climate change, ecological studies increasingly address effects of temperature on organisms and ecosystems. To measure air temperature at biologically relevant scales in the field, ecologists often use small, portable temperature sensors. Sensors must be shielded from solar radiation to provide accurate temperature measurements, but our review of 18 years of ecological literature indicates that shielding practices vary across studies (when reported at all), and that ecologists often invent and construct ad hoc radiation shields without testing their efficacy. We performed two field experiments to examine the accuracy of temperature observations from three commonly used portable data loggers (HOBO Pro, HOBO Pendant, and iButton hygrochron) housed in manufactured Gill shields or ad hoc, custom‐fabricated shields constructed from everyday materials such as plastic cups. We installed this sensor array (five replicates of 11 sensor‐shield combinations) at weather stations located in open and forested sites. HOBO Pro sensors with Gill shields were the most accurate devices, with a mean absolute error of 0.2°C relative to weather stations at each site. Error in ad hoc shield treatments ranged from 0.8 to 3.0°C, with the largest errors at the open site. We then deployed one replicate of each sensor‐shield combination at five sites that varied in the amount of urban impervious surface cover, which presents a further shielding challenge. Bias in sensors paired with ad hoc shields increased by up to 0.7°C for every 10% increase in impervious surface. Our results indicate that, due to variable shielding practices, the ecological literature likely includes highly biased temperature data that cannot be compared directly across studies. If left unaddressed, these errors will hinder efforts to predict biological responses to climate change. We call for greater standardization in how temperature data are recorded in the field, handled in analyses, and reported in publications.

Ecology and Evolution↗

Editorial: Synthetic Aperture Radar and natural hazards: Applications and outlooks

The ability of Synthetic Aperture Radar (SAR) to image the Earth’s surface, even through dense cloud cover and in night-and-day conditions, can facilitate the evaluation and monitoring of natural hazards and the management of natural disasters. The family of SAR satellite sensors orbits the Earth at an altitude ranging from 500 to 800 km, following sun-synchronous, near-polar orbits, slightly inclined with respect to Earth meridians. The most commonly used bands in SAR applications are the C-band (5–6 GHz, ~5,6 cm wavelength), the X-band (8–12 GHz, ~3,1 cm wavelength) and the L-band (1–2 GHz ~23 cm wavelength) with a temporal resolution depending on the satellite revisiting time. The availability of SAR has made a new spectrum of measurements possible on a global and spatial scale not attainable by ground-based studies, revealing critical insights into remote or poorly understood areas (e.g., Biggs et al., 2014). This Research Topics presents a review of articles on the state-of-art in the application of SAR sensors to study surface deformation in different geologic environments and triggered by a variety of processes. The topics discussed range from the analysis of co-seismic deformation (Marryman Boncori) to studies of volcanic unrest (Dzurisin et al., Garthwaite et al.), monitoring of landslides (Bianchini et al.) and ground subsidence in urban areas (Solari et al.).

Frontiers in Earth Science↗

MODIS and SeaWIFS on-orbit lunar calibration

The Moon plays an important role in the radiometric stability monitoring of the NASA Earth Observing System's (EOS) remote sensors. The MODIS and SeaWIFS are two of the key instruments for NASA's EOS missions. The MODIS Protoflight Model (PFM) on-board the Terra spacecraft and the MODIS Flight Model 1 (FM1) on-board the Aqua spacecraft were launched on December 18, 1999 and May 4, 2002, respectively. They view the Moon through the Space View (SV) port approximately once a month to monitor the long-term radiometric stability of their Reflective Solar Bands (RSB). SeaWIFS was launched on-board the OrbView-2 spacecraft on August 1, 1997. The SeaWiFS lunar calibrations are obtained once a month at a nominal phase angle of 7??. The lunar irradiance observed by these instruments depends on the viewing geometry. The USGS photometric model of the Moon (the ROLO model) has been developed to provide the geometric corrections for the lunar observations. For MODIS, the lunar view responses with corrections for the viewing geometry are used to track the gain change for its reflective solar bands (RSB). They trend the system response degradation at the Angle Of Incidence (AOI) of sensor's SV port. With both the lunar observation and the on-board Solar Diffuser (SD) calibration, it is shown that the MODIS system response degradation is wavelength, mirror side, and AOI dependent. Time-dependent Response Versus Scan angle (RVS) Look-Up Tables (LUT) are applied in MODIS RSB calibration and lunar observations play a key role in RVS derivation. The corrections provided by the RVS in the Terra and Aqua MODIS data from the 412 nm band are as large as 16% and 13%, respectively. For SeaWIFS lunar calibrations, the spacecraft is pitched across the Moon so that the instrument views the Moon near nadir through the same optical path as it views the Earth. The SeaWiFS system gain changes for its eight bands are calibrated using the geometrically-corrected lunar observations. The radiometric corrections to the SeaWiFS data, after more than ten years on orbit, are 19% at 865 nm, 8% at 765 nm, and 1-3% in the other bands. In this report, the lunar calibration algorithms are reviewed and the RSB gain changes observed by the lunar observations are shown for all three sensors. The lunar observations for the three instruments are compared using the USGS photometric model. The USGS lunar model facilitates the cross calibration of instruments with different spectra bandpasses whose measurements of the Moon differ in time and observing geometry.

Conference Paper↗

Guidelines and standard procedures for continuous water-quality monitors: Station operation, record computation, and data reporting

The U.S. Geological Survey uses continuous water-quality monitors to assess the quality of the Nation's surface water. A common monitoring-system configuration for water-quality data collection is the four-parameter monitoring system, which collects temperature, specific conductance, dissolved oxygen, and pH data. Such systems also can be configured to measure other properties, such as turbidity or fluorescence. Data from sensors can be used in conjunction with chemical analyses of samples to estimate chemical loads. The sensors that are used to measure water-quality field parameters require careful field observation, cleaning, and calibration procedures, as well as thorough procedures for the computation and publication of final records. This report provides guidelines for site- and monitor-selection considerations; sensor inspection and calibration methods; field procedures; data evaluation, correction, and computation; and record-review and data-reporting processes, which supersede the guidelines presented previously in U.S. Geological Survey Water-Resources Investigations Report WRIR 00-4252. These procedures have evolved over the past three decades, and the process continues to evolve with newer technologies.

Techniques and Methods↗

A review of near-surface QS estimation methods using active and passive sources

Seismic attenuation and the associated quality factor ( Q ) have long been studied in various sub-disciplines of seismology, ranging from observational and engineering seismology to near-surface geophysics and soil/rock dynamics with particular emphasis on geotechnical earthquake engineering and engineering seismology. Within the broader framework of seismic site characterization, various experimental techniques have been adopted over the years to measure the near-surface shear-wave quality factor ( Q S ). Common methods include active- and passive-source recording techniques performed at the free surface of soil deposits and within boreholes, as well as laboratory tests. This paper intends to provide an in-depth review of what Q is and, in particular, how Q S is estimated in the current practice. After motivating the importance of this parameter in seismology, we proceed by recalling various theoretical definitions of Q and its measurement through laboratory tests, considering various deformation modes, most notably Q P and Q S . We next provide a review of the literature on Q S estimation methods that use data from surface and borehole sensor recordings. We distinguish between active- and passive-source approaches, along with their pros and cons, as well as the state-of-the-practice and state-of-the-art. Finally, we summarize the phenomena associated with the high-frequency shear-wave attenuation factor (kappa) and its relation to Q , as well as other lesser-known attenuation parameters.

Journal of Seismology↗

Monitoring the Riverine Pulse: Applying high-frequency nitrate data to advance integrative understanding of biogeochemical and hydrological processes

Widespread deployment of sensors that measure river nitrate (NO3-) concentrations has led to many recent publications in water resources journals including review papers focused on data quality assurance, improved load calculations, and better nutrient management. The principal objective of this paper is to review and synthesize studies of high-frequency NO3- data that have aimed to improve understanding of the hydrologic and biogeochemical processes underlying episodic, diel, and long-term stream NO3- dynamics. Investigations have provided unprecedented detail on hysteresis and flushing patterns during high flow, seasonal variation during baseflow, and responses to multi-year climate variation. Analyses of high-frequency data have led to notable advances in understanding how climate variation affects spatial and temporal NO3- patterns, especially dry-wet cycles and antecedent moisture. Further advances have been limited by few investigations that include high-frequency measurements outside the channel and the short duration of many records. High-frequency data for multiple constituents have provided new insight to the relative roles of hydrology and biogeochemistry as highlighted by studies of the roles of autotrophic uptake, denitrification, riparian evapotranspiration, and temperature-driven changes in viscosity as drivers of diel patterns. Comparisons of short-duration high-frequency data with long-duration low frequency data have described similarities and differences in concentration – discharge patterns and highlighted the role of legacy stores. Investigators have applied innovative analysis approaches not previously possible with low-frequency or temporally-irregular data. Future availability of long-duration high-frequency data will provide new insight to processes, resulting in improved conceptual models and a deeper understanding of the role of climate variation.

WIREs Water↗