Search USGS⌕ Search

SEARCH · Search USGS

Results for “Rapid Communications in Mass Spectrometry”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Investigation of preparation techniques for δ2H analysis of keratin materials and a proposed analytical protocol

Accurate hydrogen isotopic measurements of keratin materials have been a challenge due to exchangeable hydrogen in the sample matrix and the paucity of appropriate isotopic reference materials for calibration. We found that the most reproducible δ 2 H VSMOW‐SLAP and mole fraction of exchangeable hydrogen, x (H) ex , of keratin materials were measured with equilibration at ambient temperature using two desiccators and two different equilibration waters with two sets of the keratin materials for 6 days. Following equilibration, drying the keratin materials in a vacuum oven for 4 days at 60 °C was most critical. The δ 2 H analysis protocol also includes interspersing isotopic reference waters in silver tubes among samples in the carousel of a thermal conversion elemental analyzer (TC/EA) reduction unit. Using this analytical protocol, δ 2 H VSMOW‐SLAP values of the non‐exchangeable fractions of USGS42 and USGS43 human‐hair isotopic reference materials were determined to be –78.5 ± 2.3 ‰ and –50.3 ± 2.8 ‰, respectively. The measured x (H) ex values of keratin materials analyzed with steam equilibration and N 2 drying were substantially higher than those previously published, and dry N 2 purging was unable to remove absorbed moisture completely, even with overnight purging. The δ 2 H values of keratin materials measured with steam equilibration were about 10 ‰ lower than values determined with equilibration in desiccators at ambient temperatures when on‐line evacuation was used to dry samples. With steam equilibrations the x (H) ex of commercial keratin powder was as high as 28 %. Using human‐hair isotopic reference materials to calibrate other keratin materials, such as hoof or horn, can introduce bias in δ 2 H measurements because the amount of absorbed water and the x (H) ex values may differ from those of unknown samples. Correct δ 2 H VSMOW‐SLAP values of the non‐exchangeable fractions of unknown human‐hair samples can be determined with atmospheric moisture equilibration by normalizing with USGS42 and USGS43 human‐hair reference materials when all materials have the same powder size.

Rapid Communications in Mass Spectrometry↗

Stable isotope reference materials and scale definitions – Outcomes of the 2024 IAEA experts meeting

The participants of the 12 th International Atomic Energy Agency (IAEA) meeting on stable isotope reference materials reached a consensus, acknowledging the existence and use of two carbon isotope delta scales: the VPDB (Vienna Peedee belemnite) scale and the VPDB-LSVEC (LSVEC - lithium carbonate prepared by H. J. Svec). Conversion models between the two scales can be established and used but introduce uncertainty. A format for isotope delta scale definition was agreed upon and was used to define the two carbon isotope delta scales and the two main oxygen isotope delta scales, VSMOW-SLAP (Vienna Standard Mean Ocean Water–Standard Light Antarctic Precipitation) and VPDB. Confirmation or identification of a second-scale–defining point is still necessary for the nitrogen and sulfur isotope delta scales. Efforts are encouraged to improve consistency among laboratories in the isotopic analysis of “non-exchangeable hydrogen” in bulk organic materials and oxygen in carbonates using the phosphoric acid reaction. Additional topics discussed include (1) need for improvement in reference materials for accurate greenhouse gas isotopic analyses; (2) reference materials under production by the IAEA, the US Geological Survey (USGS), and the US National Institute of Standards and Technology (NIST); (3) methods for value and uncertainty assignment of reference materials; and (4) calculation of carbon-13 isotope delta and oxygen-18 isotope delta of CO 2 measured by dual-inlet isotope ratio mass spectrometry.

Rapid Communications in Mass Spectrometry↗

Reaffirming the consistency of the original stock of NBS 19 limestone and its byproduct with finer grain size for δ13C and δ18O calibrations—Both distributed internationally

Rationale Approximately 3–4 kg of NBS 19 limestone, prepared in 1982 by the U.S. Geological Survey (USGS), serves as a primary reference for the carbon isotope scales VPDB and VPDB-LSVEC and the oxygen isotope scale VPDB. Its consensus values are +1.95‰ for δ 13 C and −2.2‰ for δ 18 O measurements. After more than three decades of distribution, the number of units labeled “NBS 19” shrunk substantially, and the remaining material was quarantined, with a small fraction retained at the USGS and a larger fraction entrusted to the International Atomic Energy Agency (IAEA) for secure storage. Given the critical role of NBS 19, verifying the integrity of its δ 13 C and δ 18 O values across these storage locations is essential. Method Samples from IAEA and USGS stock materials were selected to ensure traceability of carbon and oxygen isotopes to NBS 19 distribution units from various storage locations. To achieve this, distribution units labeled as NBS 19 from both the IAEA and the National Institute of Standards and Technology (NIST) were included. During evaluation, two distinct grain sizes were identified within these units. Grain size was assessed using sieves on five selected samples. The δ 13 C and δ 18 O values of finer and coarser fractions (both labeled NBS 19) were measured at USGS using continuous-flow isotope-ratio mass spectrometry on 100- and 200-μg samples. Results Expanded 95% measurement uncertainties ( k = 2) for δ 13 C and δ 18 O determinations are 0.027‰ and 0.038‰ or better, respectively, for quarantined NBS 19 stocks and finer byproduct calcite, which we term “NBS-19 byproduct,” regardless of storage location. Between the 1990s and circa 2011, NBS-19 byproduct labeled “NBS 19,” distributed by NIST and the IAEA, shows these findings. Conclusions NBS 19 primary isotopic reference material should be used for calibration of new isotopic reference materials rather than NBS-19 byproduct secondary isotopic reference material.

Rapid Communications in Mass Spectrometry↗

Documenting utility of paddlefish otoliths for quantification of metals using inductively coupled plasma mass spectrometry

RATIONALE The otoliths of the inner ear of fishes record the environment of their surrounding water throughout their life. For paddlefish ( Polyodon spathula ), otoliths have not been routinely used by scientists since their detriments were outlined in the early 1940s. We sought to determine if paddlefish otoliths were useful for resolving elemental information contained within. METHODS Adult paddlefish were collected from two wild, self-sustaining populations in Oklahoma reservoirs in the Arkansas River basin. Juveniles were obtained from a hatchery in the Red River basin of Oklahoma. Otoliths were removed and laser ablation, inductively coupled plasma mass spectrometry (ICP-MS) was used to quantify eight elements (Li, Mg, Mn, Rb, Sr, Y, Ba, and Pb) along the core and edge portions, which were analyzed for differences between otolith regions and among paddlefish sources. RESULTS Differences were found among samples for six of the eight elements examined. Otoliths from Red River basin paddlefish born in a hatchery had significantly lower amounts of Mg and Mn, but higher levels of Rb than otoliths from wild paddlefish in the Arkansas River basin. Concentrations of Y, Sr, and Ba were reduced on the edges of adult paddlefish from both reservoirs compared with the cores. CONCLUSIONS This research shows the utility of using an ICP-MS analysis of paddlefish otoliths. Future research that seeks to determine sources of paddlefish production, such as which reservoir tributaries are most important for reproduction or what proportion of the population is composed of wild versus hatchery-produced individuals, appears promising. Published in 2013. This article is a U.S. Government work and is in the public domain in the USA.

Rapid Communications in Mass Spectrometry↗

Nicotine, acetanilide and urea multi-level 2 H-, 13 C- and 15 N-abundance reference materials for continuous-flow isotope ratio mass spectrometry

Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the S values of these reference materials should bracket the isotopic range of samples with unknown S values. While the practice of analyzing two isotopically distinct reference materials is common for water (VSMOW-SLAP) and carbonates (NBS 19 and L-SVEC), the lack of widely available organic reference materials with distinct isotopic composition has hindered the practice when analyzing organic materials by elemental analysis/isotope ratio mass spectrometry (EA-IRMS). At present only L-glutamic acids USGS40 and USGS41 satisfy these requirements for ?? 13 C and ?? 13 N, with the limitation that L-glutamic acid is not suitable for analysis by gas chromatography (GC). We describe the development and quality testing of (i) four nicotine laboratory reference materials for on-line (i.e. continuous flow) hydrogen reductive gas chromatography-isotope ratio mass-spectrometry (GC-IRMS), (ii) five nicotines for oxidative C, N gas chromatography-combustion-isotope ratio mass-spectrometry (GC-C-IRMS, or GC-IRMS), and (iii) also three acetanilide and three urea reference materials for on-line oxidative EA-IRMS for C and N. Isotopic off-line calibration against international stable isotope measurement standards at Indiana University adhered to the 'principle of identical treatment'. The new reference materials cover the following isotopic ranges: ?? 2 H nicotine -162 to -45%o, ?? 13 C nicotine -30.05 to +7.72%, ?? 15 N nicotine -6.03 to +33.62%; ?? 15 N acetanilide +1-18 to +40.57%; ?? 13 C urea -34.13 to +11.71%, ?? 15 N urea +0.26 to +40.61% (recommended ?? values refer to calibration with NBS 19, L-SVEC, IAEA-N-1, and IAEA-N-2). Nicotines fill a gap as the first organic nitrogen stable isotope reference materials for GC-IRMS that are available with different ?? 13 N values. Comparative ?? 13 C and ?? 15 N on-line EA-IRMS data from 14 volunteering laboratories document the usefulness and reliability of acetanilides and ureas as EA-IRMS reference materials.

Rapid Communications in Mass Spectrometry↗

Three new calcium formate reference materials for δ13C measurements and a redetermination of the R(13C/12C) ratio for VPDB based on proton nuclear magnetic resonance measurements

Rationale Isotope ratio mass spectrometry (IRMS) and proton nuclear magnetic resonance ( 1 H NMR) spectroscopy are independent techniques for determining the isotope ratio R ( 13 C/ 12 C) in organic compounds. However, the lack of suitable reference materials has limited intercalibration of results from these methods. Methods Three high-purity calcium formate isotopic reference materials were developed, each ideal for accurate isotope ratio measurements by both 1 H NMR and isotope-ratio mass spectrometry (IRMS). For each material, R ( 13 C/ 12 C) was determined by 1 H NMR, and the relative isotope abundance ( δ 13 C VPDB-LSVEC ) by IRMS. The combined IRMS and NMR results were used to determine the R ( 13 C/ 12 C) value of Vienna Peedee belemnite (VPDB). Results The combined datasets yield a value for R ( 13 C/ 12 C) of 0.0111050 ± 0.0000047 ( k = 2) for VPDB, which is 6.7‰ lower than the commonly cited value of 0.011180, but similar to other recent determinations. These three calcium formate reference materials exhibit high accuracy across both analytical methods and provide robust tools for instrument calibration, method validation, and inter-laboratory comparison in carbon stable isotope ratio analysis. Conclusions An accurate R ( 13 C/ 12 C) value for VPDB strengthens the link between relative ( δ 13 C VPDB-LSVEC ) values from IRMS and R ( 13 C/ 12 C) isotope ratios from NMR and other techniques. These three calcium formate isotopic reference materials (USGS106, USGS107, and USGS108) are available from the US Geological Survey and provide reference materials for calibration, method validation, and inter-laboratory comparison in carbon isotope ratio analysis.

Rapid Communications in Mass Spectrometry↗

Preliminary assessment of stable nitrogen and oxygen isotopic composition of USGS51 and USGS52 nitrous oxide reference gases and perspectives on calibration needs

Rationale Despite a long history and growing interest in isotopic analyses of N 2 O, there is a lack of isotopically characterized N 2 O isotopic reference materials (standards) to enable normalization and reporting of isotope‐delta values. Here we report the isotopic characterization of two pure N 2 O gas reference materials, USGS51 and USGS52, which are now available for laboratory calibration ( https://isotopes.usgs.gov/lab/referencematerials.html ). Methods A total of 400 sealed borosilicate glass tubes of each N 2 O reference gas were prepared from a single gas filling of a high vacuum line. We demonstrated isotopic homogeneity via dual‐inlet isotope‐ratio mass spectrometry. Isotopic analyses of these reference materials were obtained from eight laboratories to evaluate interlaboratory variation and provide preliminary isotopic characterization of their δ 15 N, δ 18 O, δ 15 N α , δ 15 N β and site preference ( S P ) values. Results The isotopic homogeneity of both USGS51 and USGS52 was demonstrated by one‐sigma standard deviations associated with the determinations of their δ 15 N, δ 18 O, δ 15 N α , δ 15 N β and S P values of 0.12 mUr or better. The one‐sigma standard deviations of S P measurements of USGS51 and USGS52 reported by eight laboratories participating in the interlaboratory comparison were 1.27 and 1.78 mUr, respectively. Conclusions The agreement of isotope‐delta values obtained in the interlaboratory comparison was not sufficient to provide reliable accurate isotope measurement values for USGS51 and USGS52. We propose that provisional values for the isotopic composition of USGS51 and USGS52 determined at the Tokyo Institute of Technology can be adopted for normalizing and reporting sample data until further refinements are achieved through additional calibration efforts.

Rapid Communications in Mass Spectrometry↗

Two new organic reference materials for δ13C and δ15N measurements and a new value for the δ13C of NBS 22 oil

Analytical grade L-glutamic acid is chemically stable and has a C/N mole ratio of 5, which is close to that of many of natural biological materials, such as blood and animal tissue. Two L-glutamic acid reference materials with substantially different 13 C and 15 N abundances have been prepared for use as organic reference materials for C and N isotopic measurements. USGS40 is analytical grade L-glutamic acid and has a δ 13 C value of −26.24‰ relative to VPDB and a δ 15 N value of −4.52‰ relative to N 2 in air. USGS41 was prepared by dissolving analytical grade L-glutamic acid with L-glutamic acid enriched in 13 C and 15 N. USGS41 has a δ 13 C value of +37.76‰ and a δ 15 N value of +47.57‰. The δ 13 C and δ 15 N values of both materials were measured against the international reference materials NBS 19 calcium carbonate ( δ 13 C = +1.95‰), L-SVEC lithium carbonate ( δ 13 C = −46.48‰), IAEA-N-1 ammonium sulfate ( δ 15 N = 0.43‰), and USGS32 potassium nitrate ( δ 15 N = 180‰) by on-line combustion continuous-flow and off-line dual-inlet isotope-ratio mass spectrometry. Both USGS40 and USGS41 are isotopically homogeneous; reproducibility of δ 13 C is better than 0.13‰, and that of δ 15 N is better than 0.13‰ in 100-μg amounts. These two isotopic reference materials can be used for (i) calibrating local laboratory reference materials, and (ii) quantifying drift with time, mass-dependent fractionations, and isotope-ratio-scale contraction in the isotopic analysis of various biological materials. Isotopic results presented in this paper yield a δ 13 C value for NBS 22 oil of −29.91‰, in contrast to the commonly accepted value of −29.78‰ for which off-line blank corrections probably have not been quantified satisfactorily.

Rapid Communications in Mass Spectrometry↗

Detection of bacteria from biological mixtures using immunomagnetic separation combined with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

A rapid method for identifying specific bacteria from complex biological mixtures using immunomagnetic separation coupled to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry has been developed. The technique employs commercially available magnetic beads coated with polycolonal antibodies raised against specific bacteria and whole cell analysis by MALDI-MS. A suspension of a bacterial mixture is mixed with the immunomagnetic beads specific for the target microorganism. After a short incubation period (20 mins) the bacteria captured by the beads are washed, resuspended in deionized H2O and directly applied onto a MALDI probe. Liquid suspensions containing bacterial mixtures can be screened within 1 h total analysis time. Positive tests result in the production of a fingerprint mass spectrum primarily consisting of protein biomarkers characteristic of the targeted microorganism. Using this procedure, Salmonella choleraesuis was isolated and detected from standard bacterial mixtures and spiked samples of river water, human urine, and chicken blood. Copyright ?? 2001 John Wiley & Sons, Ltd.

Rapid Communications in Mass Spectrometry↗

Lake Louise Water (USGS47): A new isotopic reference water for stable hydrogen and oxygen isotope measurements

"RATIONALE: Because of the paucity of isotopic reference waters for daily use, a new secondary isotopic reference material has been prepared from Lake Louise water from Alberta, Canada for international distribution. MOTHODS: This water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This isotopic reference water is available by the case of 144 glass ampoules containing 5 mL of water in each ampoule. RESULTS: The δ2H and δ18O values of this reference water are –150.2 ± 0.5 ‰ and –19.80 ± 0.02 ‰, respectively, relative to VSMOW on scales normalized such that the δ2H and δ18O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty (U = 2uc) about the reference value that provides an interval that has about a 95-percent probability of encompassing the true value. CONCLUSION: This isotopic reference material, designated as USGS47, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and stable oxygen isotopic analysis of water with a mass spectrometer or a laser absorption spectrometer. "

Rapid Communications in Mass Spectrometry↗

Biscayne aquifer drinking water (USGS45): a new isotopic reference material for δ 2 H and δ 18 O measurements of water

RATIONALE As a result of the scarcity of isotopic reference waters for daily use, a new secondary isotopic reference material for international distribution has been prepared from drinking water collected from the Biscayne aquifer in Ft. Lauderdale, Florida. METHODS This isotopic reference water was filtered, homogenized, loaded into glass ampoules, sealed with a torch, autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available by the case of 144 glass ampoules containing either 4 mL or 5 mL of water in each ampoule. RESULTS The δ 2 H and δ 18 O values of this reference material are –10.3 ± 0.4 ‰ and –2.238 ± 0.011 ‰, respectively, relative to VSMOW, on scales normalized such that the δ 2 H and δ 18 O values of SLAP reference water are, respectively, –428 and –55.5 ‰. Each uncertainty is an estimated expanded uncertainty ( U  = 2 u c ) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. CONCLUSIONS This isotopic reference material, designated as USGS45, is intended as one of two isotopic reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer.

Rapid Communications in Mass Spectrometry↗

A new isotopic reference material for stable hydrogen and oxygen isotope-ratio measurements of water—USGS50 Lake Kyoga Water

Rationale As a result of the need for isotopic reference waters having high δ 2 H VSMOW-SLAP and δ 18 O VSMOW-SLAP values for daily use, especially for tropical and equatorial-zone freshwaters, a new secondary isotopic reference material for international distribution was prepared from water collected from Lake Kyoga, Uganda. Methods This isotopic reference lakewater was filtered through a membrane with 0.2-µm pore size, homogenized, loaded into glass ampoules that were sealed with a torch and autoclaved to eliminate biological activity, and measured by dual-inlet isotope-ratio mass spectrometry. This reference material is available in a case of 144 glass ampoules each containing 5 mL of water. Results The δ 2 H and δ 18 O values of this reference material are +32.8 ± 0.4 and +4.95 ± 0.02 mUr (milliurey = 0.001 = 1 ‰), respectively, relative to VSMOW, on scales normalized such that the δ 2 H and δ 18 O values of SLAP reference water are, respectively, −428 and −55.5 mUr. Each uncertainty is an estimated expanded uncertainty ( U  = 2 u c ) about the reference value that provides an interval that has about a 95 % probability of encompassing the true value. Conclusions This isotopic reference material, designated as USGS50, is intended as one of two reference waters for daily normalization of stable hydrogen and oxygen isotopic analysis of water with an isotope-ratio mass spectrometer or a laser absorption spectrometer, of use especially for isotope-hydrology laboratories analyzing freshwater samples from equatorial and tropical regions.

Lake Kyoga↗

The influence of sample matrix on the accuracy of nitrite N and O isotope ratio analyses with the azide method

Rationale The isotope ratios of nitrogen ( 15 N/ 14 N) and oxygen ( 18 O/ 16 O) in nitrite (NO 2 − ) can be measured by conversion of the nitrite into nitrous oxide (N 2 O) with azide, followed by mass spectrometric analysis of N 2 O by gas chromatography isotope ratio mass spectrometry (GC/IRMS). While applying this method to brackish samples, we noticed that the N and O isotope ratio measurements of NO 2 − are highly sensitive to sample salinity and to the pH at which samples are preserved. Methods We investigated the influence of sample salinity and sample preservation pH on the N and O isotope ratios of the N 2 O produced from the reaction of NO 2 − with azide. The N 2 O isotope ratios were measured by GC/IRMS. Results Under the experimental reaction conditions, the conversion of NO 2 − into N 2 O was less complete in lower salinity solutions, resulting in respective N and O isotopic offsets of +2.5‰ and −14.0‰ compared with seawater solutions. Differences in salinity were also associated with differences in the fraction of O atoms exchanged between NO 2 − and water during the reaction. Similarly, aqueous NO 2 − samples preserved at elevated pH values resulted in the incomplete conversion of NO 2 − into N 2 O by azide, and consequent pH‐dependent isotopic offsets, as well as differences in the fraction of O atoms exchanged with water. The addition of sodium chloride to the reaction matrix of samples and standards largely mitigated salinity‐dependent isotopic offsets in the N 2 O product, and nearly homogenized the fraction of O atom exchange among samples of different salinity. A test of the hypobromite–azide method to measure N isotope ratios of ammonium by conversion into NO 2 − then N 2 O revealed no influence of sample salinity on the N isotope ratios of the N 2 O product. Conclusions We outline recommendations to mitigate potential matrix effects among samples and standards, to improve the accuracy of N and O isotope ratios in NO 2 − measured with the azide method.

Rapid Communications in Mass Spectrometry↗

Optimization of on-line hydrogen stable isotope ratio measurements of halogen- and sulfur-bearing organic compounds using elemental analyzer–chromium/high-temperature conversion isotope ratio mass spectrometry (EA-Cr/HTC-IRMS)

Rationale: Accurate hydrogen isotopic analysis of halogen- and sulfur-bearing organics has not been possible with traditional high-temperature conversion (HTC) because the formation of hydrogen-bearing reaction products other than molecular hydrogen (H2) is responsible for non-quantitative H2 yields and possible hydrogen isotopic fractionation. Our previously introduced, new chromium-based EA-Cr/HTC-IRMS (Elemental Analyzer–Chromium/High-Temperature Conversion Isotope Ratio Mass Spectrometry) technique focused primarily on nitrogen-bearing compounds. Several technical and analytical issues concerning halogen- and sulfur-bearing samples, however, remained unresolved and required further refinement of the reactor systems. Methods: The EA-Cr/HTC reactor was substantially modified for the conversion of halogen- and sulfur-bearing samples. The performance of the novel conversion setup for solid and liquid samples was monitored and optimized using a simultaneously operating dual-detection system of IRMS and ion trap MS. The method with several variants in the reactor, including the addition of manganese metal chips, was evaluated in three laboratories using EA-Cr/HTC-IRMS (on-line method) and compared with traditional uranium-reduction-based conversion combined with manual dual-inlet IRMS analysis (off-line method) in one laboratory. Results: The modified EA-Cr/HTC reactor setup showed an overall H2-recovery of more than 96% for all halogen- and sulfur-bearing organic compounds. All results were successfully normalized via two-point calibration with VSMOW-SLAP reference waters. Precise and accurate hydrogen isotopic analysis was achieved for a variety of organics containing F-, Cl-, Br-, I-, and S-bearing heteroelements. The robust nature of the on-line EA-Cr/HTC technique was demonstrated by a series of 196 consecutive measurements with a single reactor filling. Conclusions: The optimized EA-Cr/HTC reactor design can be implemented in existing analytical equipment using commercially available material and is universally applicable for both heteroelement-bearing and heteroelement-free organic-compound classes. The sensitivity and simplicity of the on-line EA-Cr/HTC-IRMS technique provide a much needed tool for routine hydrogen-isotope source tracing of organic contaminants in the environment. Copyright © 2016 John Wiley & Sons, Ltd.

Rapid Communications in Mass Spectrometry↗

Using stable oxygen isotope dual-inlet isotope-ratio mass spectrometry to elucidate uranium transport and mixed 230Th/U calcite formation ages at the seminal Devils Hole, Nevada, natural laboratory

Rationale Vein calcite in Devils Hole has been precipitating continuously in oxygen-isotope equilibrium at a constant temperature for over 500 000 years, providing an unmatched δ 18 O paleoclimate time series. A substantial issue is that coeval calcite (based on matching δ 18 O values) has uranium-series ages differing by 12 000 years. Methods An unparalleled high-accuracy δ 18 O chronology series from continuously submerged calcite was used to correct the published uranium-series ages of non-continuously formed calcite in two cores, cyclically exposed by water-table decline during glacial–interglacial transitions. This method relies on the premise that the δ 18 O values of coevally precipitated calcite are identical, allowing matching calcite δ 18 O values to establish formation ages. Results Exposed calcite can have apparent ages that are 12 000 years too young due to unrecognized uranium mobility and resulting mixed ages identified in over 50 mixed uranium-series ages from previous studies. Secondary uranium in fluids, sourced from the formation or dissolution of porous carbonate deposits (folia) with high uranium-238 ( 238 U) concentrations, has migrated up to 10 mm into vein calcite. Conclusions The continuously submerged Devils Hole δ 18 O chronology is not explained by orbital forcing. Rather, this chronology represents a regional climate record in the southern Great Basin of sea-surface-temperature (SST) variations off California, variations that preceded the last and penultimate deglaciations by 5000 to approximately 10 000 years. Temporal discrepancies between the continuously submerged Devils Hole chronology and other regional δ 18 O records (e.g., the Leviathan chronology) can be explained by unrecognized cryptic, pernicious uranium mobility, leading to model estimations that may be thousands of years younger than actual ages. Consequently, paleo-moisture availability, water-table, and groundwater recharge models based on these mixed uranium-series ages are too young by as much as 12 000 years. The potential for post-formation uranium addition in subaerial cores and speleothems underscores the need for caution in uranium-series dating, highlighting δ 18 O time-series comparisons as a method for identifying mixed ages.

Nevada↗

Continuous flow stable isotope methods for study of δ 13 C fractionation during halomethane production and degradation

Gas chromatography/mass spectrometry/isotope ratio mass spectrometry (GC/MS/IRMS) methods for δ 13 C measurement of the halomethanes CH 3 Cl, CH 3 Br, CH 3 I and methanethiol (CH 3 SH) during studies of their biological production, biological degradation, and abiotic reactions are presented. Optimisation of gas chromatographic parameters allowed the identification and quantification of CO 2 , O 2 , CH 3 Cl, CH 3 Br, CH 3 I and CH 3 SH from a single sample, and also the concurrent measurement of δ 13 C for each of the halomethanes and methanethiol. Precision of δ 13 C measurements for halomethane standards decreased (±0.3, ±0.5 and ±1.3‰) with increasing mass (CH 3 Cl, CH 3 Br, CH 3 I, respectively). Given that carbon isotope effects during biological production, biological degradation and some chemical (abiotic) reactions can be as much as 100‰, stable isotope analysis offers a precise method to study the global sources and sinks of these halogenated compounds that are of considerable importance to our understanding of stratospheric ozone destruction.

Rapid Communications in Mass Spectrometry↗

A new organic reference material, L-glutamic acid, USGS41a, for δ 13 C and δ 15 N measurements − a replacement for USGS41

Rationale The widely used l -glutamic acid isotopic reference material USGS41, enriched in both 13 C and 15 N, is nearly exhausted. A new material, USGS41a, has been prepared as a replacement for USGS41. Methods USGS41a was prepared by dissolving analytical grade l -glutamic acid enriched in 13 C and 15 N together with l -glutamic acid of normal isotopic composition. The δ 13 C and δ 15 N values of USGS41a were directly or indirectly normalized with the international reference materials NBS 19 calcium carbonate ( δ 13 C VPDB = +1.95 mUr, where milliurey = 0.001 = 1 ‰), LSVEC lithium carbonate ( δ 13 C VPDB = −46.6 mUr), and IAEA-N-1 ammonium sulfate ( δ 15 N Air = +0.43 mUr) and USGS32 potassium nitrate ( δ 15 N = +180 mUr exactly) by on-line combustion, continuous-flow isotope-ratio mass spectrometry, and off-line dual-inlet isotope-ratio mass spectrometry. Results USGS41a is isotopically homogeneous; the reproducibility of δ 13 C and δ 15 N is better than 0.07 mUr and 0.09 mUr, respectively, in 200-μg amounts. It has a δ 13 C value of +36.55 mUr relative to VPDB and a δ 15 N value of +47.55 mUr relative to N 2 in air. USGS41 was found to be hydroscopic, probably due to the presence of pyroglutamic acid. Experimental results indicate that the chemical purity of USGS41a is substantially better than that of USGS41. Conclusions The new isotopic reference material USGS41a can be used with USGS40 (having a δ 13 C VPDB value of −26.39 mUr and a δ 15 N Air value of −4.52 mUr) for (i) analyzing local laboratory isotopic reference materials, and (ii) quantifying drift with time, mass-dependent isotopic fractionation, and isotope-ratio-scale contraction for isotopic analysis of biological and organic materials. Published in 2016. This article is a U.S. Government work and is in the public domain in the USA.

Rapid Communications in Mass Spectrometry↗

Comparison of δ13C analyses of individual foraminifer (Orbulina universa) shells by secondary ion mass spectrometry and gas source mass spectrometry

Rationale: The use of secondary ion mass spectrometry (SIMS) to perform micrometer-scale in situ carbon isotope (δ 13 C) analyses of shells of marine microfossils called planktic foraminifers holds promise to explore calcification and ecological processes. The potential of this technique, however, cannot be realized without comparison to traditional whole-shell δ 13 C values measured by gas source mass spectrometry (GSMS). Methods: Paired SIMS and GSMS δ 13 C values measured from final chamber fragments of the same shell of the planktic foraminifer Orbulina universa are compared. The SIMS–GSMS δ 13 C differences (Δ 13 C SIMS-GSMS ) were determined via paired analysis of hydrogen peroxide-cleaned fragments of modern cultured specimens and of fossil specimens from deep-sea sediments that were either untreated, sonicated, and cleaned with hydrogen peroxide or vacuum roasted. After treatment, fragments were analyzed by a CAMECA IMS 1280 SIMS instrument and either a ThermoScientific MAT-253 or a Fisons Optima isotope ratio mass spectrometer (GSMS). Results: Paired analyses of cleaned fragments of cultured specimens ( n = 7) yield no SIMS–GSMS δ 13 C difference. However, paired analyses of untreated ( n = 18) and cleaned ( n = 12) fragments of fossil shells yield average Δ 13 C SIMS-GSMS values of 0.8‰ and 0.6‰ (±0.2‰, 2 SE), respectively, while vacuum roasting of fossil shell fragments ( n = 11) removes the SIMS–GSMS δ 13 C difference. Conclusions: The noted Δ 13 C SIMS-GSMS values are most likely due to matrix effects causing sample–standard mismatch for SIMS analyses but may also be a combination of other factors such as SIMS measurement of chemically bound water. The volume of material analyzed via SIMS is ~10 5 times smaller than that analyzed by GSMS; hence, the extent to which these Δ 13 C SIMS-GSMS values represent differences in analyte or instrument factors remains unclear.

Rapid Communications in Mass Spectrometry↗