Search USGS⌕ Search

SEARCH · Search USGS

Results for “Journal of Structural Engineering”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Pros and cons of rotating ground motion records to fault-normal/parallel directions for response history analysis of buildings

According to the regulatory building codes in the United States (e.g., 2010 California Building Code), at least two horizontal ground motion components are required for three-dimensional (3D) response history analysis (RHA) of building structures. For sites within 5 km of an active fault, these records should be rotated to fault-normal/fault-parallel (FN/FP) directions, and two RHAs should be performed separately (when FN and then FP are aligned with the transverse direction of the structural axes). It is assumed that this approach will lead to two sets of responses that envelope the range of possible responses over all nonredundant rotation angles. This assumption is examined here, for the first time, using a 3D computer model of a six-story reinforced-concrete instrumented building subjected to an ensemble of bidirectional near-fault ground motions. Peak values of engineering demand parameters (EDPs) were computed for rotation angles ranging from 0 through 180° to quantify the difference between peak values of EDPs over all rotation angles and those due to FN/FP direction rotated motions. It is demonstrated that rotating ground motions to FN/FP directions (1) does not always lead to the maximum responses over all angles, (2) does not always envelope the range of possible responses, and (3) does not provide maximum responses for all EDPs simultaneously even if it provides a maximum response for a specific EDP.

Journal of Structural Engineering↗

Seismic response of eccentrically braced tall buildings

Spectral analysis and system identification techniques are used to analyze a set of acceleration reponse records obtained during the Loma Prieta earthquake from the 47-story, moment-resisting framed and eccentrically braced Embarcadero Building (EMB). The EMB was constructed in 1979 based on the 1976 Uniform Building Code requirements and a design response spectra defined by two levels of earthquake performances. The EMB is in the lower market area of San Francisco, which is of great interest to the engineering community because of the area's soft soil characteristics that amplify ground motions originating at long distances, and because the Embarcadero freeway suffered extensive damage during the earthquake and was razed in 1991. The first modal frequencies of the building at approximately 0.19 Hz (north-south) and 0.16 Hz (east-west) are identified. The torsional response and rocking motions of the building are insignificant. Discontinuity of stiffness and mass at the 40th floor level causes significant response issues above that floor such as excessive drift ratios.

Journal of Structural Engineering↗

Modal-pushover-based ground-motion scaling procedure

Earthquake engineering is increasingly using nonlinear response history analysis (RHA) to demonstrate the performance of structures. This rigorous method of analysis requires selection and scaling of ground motions appropriate to design hazard levels. This paper presents a modal-pushover-based scaling (MPS) procedure to scale ground motions for use in a nonlinear RHA of buildings. In the MPS method, the ground motions are scaled to match to a specified tolerance, a target value of the inelastic deformation of the first-mode inelastic single-degree-of-freedom (SDF) system whose properties are determined by the first-mode pushover analysis. Appropriate for first-mode dominated structures, this approach is extended for structures with significant contributions of higher modes by considering elastic deformation of second-mode SDF systems in selecting a subset of the scaled ground motions. Based on results presented for three actual buildings-4, 6, and 13-story-the accuracy and efficiency of the MPS procedure are established and its superiority over the ASCE/SEI 7-05 scaling procedure is demonstrated.

Journal of Structural Engineering↗

Seismic response and damage detection analyses of an instrumented steel moment-framed building

The seismic performance of steel moment-framed buildings has been of particular interest since brittle fractures were discovered at the beam-column connections in a number of buildings following the M 6.7 Northridge earthquake of January 17, 1994. A case study of the seismic behavior of an extensively instrumented 13-story steel moment frame building located in the greater Los Angeles area of California is described herein. Response studies using frequency domain, joint time-frequency, system identification, and simple damage detection analyses are performed using an extensive strong motion dataset dating from 1971 to the present, supported by engineering drawings and results of postearthquake inspections. These studies show that the building's response is more complex than would be expected from its highly symmetrical geometry. The response is characterized by low damping in the fundamental mode, larger accelerations in the middle and lower stories than at the roof and base, extended periods of vibration after the cessation of strong input shaking, beating in the response, elliptical particle motion, and significant torsion during strong shaking at the top of the concrete piers which extend from the basement to the second floor. The analyses conducted indicate that the response of the structure was elastic in all recorded earthquakes to date, including Northridge. Also, several simple damage detection methods employed did not indicate any structural damage or connection fractures. The combination of a large, real structure and low instrumentation density precluded the application of many recently proposed advanced damage detection methods in this case study. Overall, however, the findings of this study are consistent with the limited code-compliant postearthquake intrusive inspections conducted after the Northridge earthquake, which found no connection fractures or other structural damage. ?? ASCE.

Journal of Structural Engineering↗

Method to estimate center of rigidity using vibration recordings

A method to estimate the center of rigidity of buildings by using vibration recordings is presented. The method is based on the criterion that the coherence of translational motions with the rotational motion is minimum at the center of rigidity. Since the coherence is a function of frequency, a gross but frequency-independent measure of the coherency is defined as the integral of the coherence function over the frequency. The center of rigidity is determined by minimizing this integral. The formulation is given for two-dimensional motions. Two examples are presented for the method; a rectangular building with ambient-vibration recordings, and a triangular building with earthquake-vibration recordings. Although the examples given are for buildings, the method can be applied to any structure with two-dimensional motions.

Journal of Structural Engineering↗

Torsional response of unique building

Acceleration response records obtained during the October 1, 1987 Whittier‐Narrows earthquake ( M s = 5.6 ) "> ( M s = 5.6 ) from the 32‐story, vertically irregular 1100 Wilshire Finance Building, of which the cross section changes from a nominally rectangular shape to a triangular one, are analyzed. The building was instrumented with 21 channels of synchronized sensors, consisting of 12 uniaxial accelerometers deployed throughout the superstructure and connected to a central recording system and three triaxial strong‐motion accelerographs in the basement. At each of the four levels of the superstructure, three uniaxial accelerometers were deployed, two parallel and at a distance apart, and the third one orthogonal to the parallel pair. The records permit the identification of the predominantly coupled torsional‐translational response of the building and the associated frequency at approximately 0.7–0.8 Hz from the difference between accelerations recorded by the parallel pairs of accelerometers at different levels. This mode corresponds to the second torsional mode. A translational mode at 0.3 Hz is also identified from the records. The center of rigidity of any instrumented level is identified by minimizing the coherence between the relative accelerations and the translational acceleration. Employing system identification techniques provides the modal damping percentage for the second torsional mode as 6–7%.

California↗

Seismic response of transamerical building. I. Data and preliminary analysis

The objective of this paper is to present preliminary analyses of a set of acceleration response records obtained during the October 17, 1989 Loma Prieta earthquake (Ms = 7.1) from the 60-story vertically tapered, pyramid-shaped Trans-america Building-a landmark of San Francisco. The building was instrumented in 1985 with 22 channels of synchronized sensors consisting of 13 uniaxial accelerometers deployed throughout the structure and connected to a central recording system and three triaxial strong-motion accelerographs at three different levels of the structure. No free-field accelerographs are at the site. The acceleration records permit the study of the behavior of this unique structure. The predominant translational response of the building and the associated frequency at approximately 0.28 Hz are identified from the records and their Fourier amplitude spectra. The records do not indicate any significant torsional motion. However, there is rocking type soil-structure interaction, and an associated frequency of approximately 2.0 Hz is identified from the Fourier amplitude spectra of the differential motions between the ground level and that at the basement. In addition, the response spectra for the basement motions indicate significant resonance in both directions at a period of approximately 0.5 seconds.

Journal of Structural Engineering↗

Seismic response of transamerica building. II. System identification

A detailed analysis of the recorded seismic response of the Transamerica Building during the October 17, 1989 Loma Prieta earthquake is presented. The system identification algorithm used for the analysis is based on the discrete-time linear filtering approach with least-squares approximation, and assumes a multi-input, single-output model for the building. Fifteen modes in the north-south direction, and 18 modes in the east-west direction are identified from the records. The analysis shows that the building's response to the earthquake was dominated by a coupled mode of vibration at 0.28 Hz in the southwest-northeast direction, which is almost parallel to one of the diagonals in the building's square cross section. The reason for this behavior is the symmetry of the building's structural characteristics, as well as the strong polarization of the S-waves of the earthquake. Several higher modes of the building were excited during the strong-motion part of the earthquake. The results also show a significant amount of rocking in the building at a frequency of 2.15 Hz.

Journal of Structural Engineering↗

Seismic response of Pacific Park Plaza. I. Data and preliminary analysis

The objective of this paper is to present analyses of a set of acceleration response records obtained during the October 17, 1989 Loma Prieta earthquake (Ms = 7.1) from the 30-story, three-winged, ductile moment-resistant reinforced-concrete-framed Pacific Park Plaza Building, located in Emeryville, east of San Francisco, Calif. The building was constructed in 1983, and instrumented in 1985 with 21 channels of synchronized uniaxial accelerometers deployed throughout the structure, and three channels of accelerometers located at free-field outside on the north side of the building, all connected to a central recording system. In addition, a triaxial strong-motion accelerograph is deployed at free-field on the south side of the building. The predominant response modes of the building and the associated frequencies at approximately 0.4 Hz and 1.0 Hz are identified visually from the unprocessed records, and also from Fourier amplitude spectra of the processed records, which, as expected, reveal significant torsional motion. In addition, the response spectra of the free-field and basement motions are very similar. These spectra show that significant structural resonances at higher modes influence both the ground level and the free-field motions, thus rising the question as to the definition of free-field motion, at least at this site. This part of the paper includes the preliminary analyses of the data acquired from this building. Part 2 of the paper provides detailed analyses of the data using system identification techniques.

Journal of Structural Engineering↗

Recorded seismic response of Pacific Park Plaza. II. System identification

This is the second of two companion papers on the recorded seismic response of the Pacific Park Plaza building, in Emeryville, Calif., during the October 17, 1989, Ms = 7.1 (surface-wave magnitude) Loma Prieta earthquake. In this second part, the recorded data are analyzed in more detail by using system-identification techniques. The three-dimensional behavior and the coupled modes of the building are determined, and the effects of soil-structure interaction are investigated. The study shows that the response of the building is nonlinear at the beginning, and becomes linear after 17 sec into the earthquake. The dominant motion of the building follows an elliptical path oriented in the southeast-northwest direction. Some of the modes are complex, with nonproportional damping, and there are phase differences among modal response components. The fundamental mode of the building is a translation in the southeast-northwest direction at 0.4 Hz, with 13% damping. The wing displacements relative to the center core are large, about 50% of the center core displacements, and indicate significant torsion in the center core. The soil-structure interaction is characterized by a vibration at 0.7 Hz. This is believed to be the fundamental frequency of the surrounding soil medium. The rocking motions of the building are negligible.

Journal of Structural Engineering↗

Seismic responses of two adjacent buildings. I. Data and analyses

In this two-part paper, responses of two, adjacent, seven-story buildings in Norwalk, California, to the Whittier-Narrows, Calif, earthquake of Oct. 1, 1987 are studied. Building A, instrumented according to code recommendations, and building B, extensively instrumented, are offset by 16.3 m from one another. The data set includes motions from the superstructure of both buildings, from a downhole below the foundation of building B, and from three free-field sites. Part I of the paper includes descriptions of the buildings, site, instrumentation, and analysis of the data of each building. System identification and spectral analysis techniques are employed in part I. Building A has identical first-mode frequencies of 0.65 Hz for both building axes. The strong-motion response characteristics of building A are considerably different than those determined from low-amplitude tests. Building B has fundamental modes at 0.76 Hz and 0.83 Hz in the major and minor axes, respectively. Torsional and diaphragm effects in building B are negligible.

Journal of Structural Engineering↗

Seismic responses of two adjacent buildings. II. Interaction

Presented in this part of the two-part paper is a study of the relations between earthquake motions recorded from two, adjacent, seven-story buildings, from a downhole below the foundation of one of the buildings and from three free-field sites, all within one city block. This unique data set was obtained during the Whittier-Narrows, Calif. earthquake of Oct. 1, 1987, Part I includes background information on the two buildings, the site, and the data set. Building response characteristics of a code-type instrumented building (A) and an extensively instrumented building (B) are also studied. In this part, spectral analysis techniques are used to study the relationships between the motions of the roofs and basements, the downhole and the free-field sites. It is asserted that there is building-soil-building interaction between the two buildings at a frequency of 2.35 Hz. Furthermore, the free-field motions are shown to be influenced by the presence of the buildings.

Journal of Structural Engineering↗

Structural response to 3D simulated earthquake motions in San Bernardino Valley

Structural repsonse to one- and three-dimensional (3D) simulated motions in San Bernardino Valley from a hypothetical earthquake along the San Andreas fault with moment magnitude 6.5 and rupture length of 30km is investigated. The results show that the ground motions and the structural response vary dramatically with the type of simulation and the location. -from Authors

Journal of Structural Engineering↗

Response of Olive View Hospital to Northridge and Whittier earthquakes

The purpose of this paper is to study the response of the conventionally designed new Olive View Medical Center (OVMC) building at 16 km from the epicenter of the January 17, 1994 Northridge, California earthquake ( M s = 6.8). OVMC is on an alluvial deposit. The building was subjected to design level peak accelerations during the earthquake and suffered only limited structural and nonstructural damage. The recorded motions at different levels of the OVMC building as well as its associated free-field sites are analyzed using spectral analyses and system identification techniques. The new OVMC building was conservatively designed in 1976 with very high lateral load resisting capability—particularly as a reaction to the detrimental fate of the original Olive View Hospital that was heavily damaged during the 1971 San Fernando earthquake. The original hospital building was later razed. The replacement structure, the new cross-shaped OVMC building, experienced peak acceleration of 2.31 g at the roof while its peak ground floor acceleration was 0.82 g . The free-field peak acceleration was 0.91 g . The lateral load resisting system of the OVMC building consists of concrete shear walls in the lower two stories and steel shear walls at the perimeter of the upper four stories. Spectral analysis shows that this stiff structure was not affected by the long duration pulses of the motions recorded at this site.

Journal of Structural Engineering↗

Wave-propagation formulation of seismic response of multistory buildings

This paper presents a discrete-time wave-propagation method to calculate the seismic response of multistory buildings, founded on layered soil media and subjected to vertically propagating shear waves. Buildings are modeled as an extension of the layered soil media by considering each story as another layer in the wave-propagation path. The seismic response is expressed in terms of wave travel times between the layers and wave reflection and transmission coefficients at layer interfaces. The method accounts for the filtering effects of the concentrated foundation and floor masses. Compared with commonly used vibration formulation, the wave-propagation formulation provides several advantages, including simplicity, improved accuracy, better representation of damping, the ability to incorporate the soil layers under the foundation, and providing better tools for identification and damage detection from seismic records. Examples are presented to show the versatility and the superiority of the method.

Journal of Structural Engineering↗

Scaling earthquake ground motions for performance-based assessment of buildings

The impact of alternate ground-motion scaling procedures on the distribution of displacement responses in simplified structural systems is investigated. Recommendations are provided for selecting and scaling ground motions for performance-based assessment of buildings. Four scaling methods are studied, namely, (1) geometric-mean scaling of pairs of ground motions, (2) spectrum matching of ground motions, (3) first-mode-period scaling to a target spectral acceleration, and (4) scaling of ground motions per the distribution of spectral demands. Data were developed by nonlinear response-history analysis of a large family of nonlinear single degree-of-freedom (SDOF) oscillators that could represent fixed-base and base-isolated structures. The advantages and disadvantages of each scaling method are discussed. The relationship between spectral shape and a ground-motion randomness parameter, ε, is presented. A scaling procedure that explicitly considers spectral shape is proposed.

Journal of Structural Engineering↗

Seismic response of a typical shear-wall dominated high-rise condominium building during the January 7, 2020 Mw6.4 Indios, Puerto Rico earthquake

Seismic response records were retrieved from the monitored 21-story (53.26-m-tall) typical Puerto Rican reinforced-concrete shear-wall dominated El Castillo Building in Mayaguez, 50 km from the mainshock epicenter of the January 7, 2020, M w 6.4 offshore Indios, Puerto Rico earthquake. The shear-wall-to-floor areas of the building are 0.97 and 3.49 in the longitudinal and transverse directions, respectively, and have a slenderness ratio of 3.0 in the transverse direction. Basement and top-floor peak accelerations were 5% g and 12.8% g, respectively. Additionally, records from a nearby free-field station indicate a site period of 0.16 s. No visible damage was observed in the building after the earthquake. Spectral ratios and system identification allow identification of the transverse, longitudinal, and torsional fundamental periods as 0.97, 0.88, and 0.81 s, respectively, and are consistent with ASCE/SEI 7-16 (2017) formula. Damping percentages are 4.5%, 3.4%, and 2.2%, respectively. The maximum drift ratios are 0.20% and 0.12% in the longitudinal and transverse directions, well below the damage threshold for structural elements of ∼0.5%.

Mayaguez, San Juan↗