Search USGSSearch

SEARCH · Search USGS

Results for “GRC Transactions”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

4 recordsLinked to original sources

Geologic setting of the proposed West Flank Forge Site, California: Suitability for EGS research and development

The proposed West Flank FORGE site is within the China Lake Naval Air Weapons Station (NAWS), China Lake, CA. The West Flank is west of the Coso geothermal field, an area of China Lake NAWS dominated by the Quaternary Coso volcanic field largely comprised of rhyolite domes and their volcaniclastic and epiclastic horizons. The largest dome flow complex, Sugarloaf Mountain, marks the northwestern margin of the geothermal field. The West Flank is situated due west of Sugarloaf. The geologic setting of the West Flank was determined from one deep well (83-11) drilled as a potential production hole in 2009. The bottom-hole temperature (BHT) of well 83-11 approaches 600 oF (315˚C), but flow tests demonstrate very low, non-commercial permeabilities. With the exception of the upper 600 feet of volcaniclastic alluvium, well 83-11 is completed in granitic basement. The West Flank possesses the primary attributes of a FORGE site: non-commercial permeability ( <10 -16 m 2 ), a 175˚ to 225˚C temperature range in crystalline rocks, and a location outside an existing geothermal field The Coso Mountains host the Coso volcanic field and are within a right-releasing stepover between the dextral Airport Lake (ALF) and Little Lake fault zones (LLFZ) and the Wild Horse Mesa and Owens Valley faults. Two distinct fault populations have been identified at Coso: WNW-trending and antithetical, NE-trending strike-slip faults and N- to NNE-trending normal faults. These faults are both high permeability drilling targets at depth within the main (productive) geothermal field and they locally segment the field into distinct hydrothermal regimes. The West Flank may be segmented from the rest of the field by one such northerly trending fault. The overall minimum principal stress orientation in the main geothermal field varies from 103˚ to 108˚; however, the minimum horizontal principal stress in 83-11 is rotated to 081˚.

California

Geologic setting of the proposed Fallon FORGE Site, Nevada: Suitability for EGS research and development

The proposed Fallon FORGE site lies within and adjacent to the Naval Air Station Fallon (NASF) directly southeast of the town of Fallon, Nevada, within the large basin of the Carson Sink in west-central Nevada. The site is located on two parcels that include land owned by the NASF and leased and owned by Ormat Nevada, Inc. The Carson Sink in the vicinity of the Fallon site is covered by Quaternary deposits, including alluvial fan, eolian, and lacustrine sediments. Four wells penetrate the entire Neogene section and bottom in Mesozoic basement. Late Miocene to Quaternary basin-fill sediments are 0.5 to >1 km thick and overlie Oligocene-Miocene volcanic and lesser sedimentary rocks. The volcanic section is 0.5 to 1.0 km thick and dominated by Miocene mafic lavas. The Neogene section rests nonconformably on heterogeneous Mesozoic basement, which consists of Triassic-Jurassic metamorphic rocks intruded by Cretaceous granitic plutons. The structural framework is dominated by a gently west-tilted half graben cut by moderately to steeply dipping N- to NNEstriking normal faults that dip both east and west. Quaternary faults have not been observed within the proposed FORGE site. Fallon was selected for a potential FORGE site due to its extensional tectonic setting, abundance of available data, existing infrastructure, and documented temperatures, permeability, and lithologic composition of potential reservoirs that fall within the ranges specified by DOE for FORGE. Since the early 1970s, more than 45 wells have been drilled for geothermal exploration within the area. Four exploration wells within the FORGE site are available for use in the project. Several additional wells are available for monitoring outside the central FORGE site within the NASF and Ormat lease area, including numerous temperature gradient holes. There is an existing, ten-station micro-seismic earthquake (MEQ) array that has been collecting data since 2001; the MEQ array can be expanded to encompass the entire Fallon project. The well data indicate that a sizeable area (~4.5 km2 ) has adequate temperatures in crystalline basement but lacks sufficient permeability within the proposed FORGE site. There are two possible, competent target formations in Mesozoic basement for stimulation in the FORGE project area: 1) Jurassic felsic metavolcanic rocks/and or metaquartzite; and 2) Cretaceous granitic intrusions. These units make up at least 3 km3 in the project area and have target temperatures of ~175-215o C. The abundant well data and detailed geophysical surveys (e.g., gravity, MT, and seismic reflection) provide significant subsurface control for the site and will permit development of a detailed 3D model. The documented temperatures, low permeability, and basement lithologies, as well as abundant available data facilitate development of a site dedicated to testing and improving new EGS technologies and techniques, thus making Fallon an ideal candidate for FORGE.

GRC Transactions

Hotspot: The Snake River geothermal drilling project - An overview

The Snake River volcanic province (SRP) overlies a thermal anomaly that extends deep into the mantle; it represents one of the highest heat flow provinces in North America, and an area with the highest calculated geothermal gradients. This makes the SRP one of the potentially highest producing geothermal districts in the United States. Elevated heat flow is typically highest along the margins of the topographic Snake River Plain and lowest along the axis of the plain, where thermal gradients are suppressed by the Snake River aquifer. Beneath this aquifer, however, thermal gradients rise again and may tap even higher heat flows associated with the intrusion of mafic magmas into a geophysically-imaged mid-crustal sill complex. The primary goal of this project is to evaluate geothermal potential in three distinct settings: (1) the high sub-aquifer geothermal gradient associated with the intrusion of mafic magmas and the release of crustal fluids from the associated wall rocks, (2) the valley-margin settings where surface heat flow may be driven by the up-flow of hot fluids along buried caldera ring-fault complexes, and (3) a more traditional fault-bounded basin with thick sedimentary cover. All settings are found within the central or western Snake River Plain and represent previously untested targets for geothermal exploration. Our first drill site tests the extent of geothermal resources along the axis of the plain, beneath the Snake River aquifer, in an area where elevated groundwater temperatures imply a significant flux of conductive or advective heat flow from below. Our second drill site assesses the geothermal potential of up-flow zones along a buried caldera margin, in an area of known geothermal potential (Twin Falls geothermal district). Further studies will include seismic reflection-refraction surveys, gravity-magnetic surveys, and downhole geophysical logs.

Idaho