Search USGS⌕ Search

SEARCH · Search USGS

Results for “Annual Report”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93Linked to original sources

Flood-frequency analyses, Manual of Hydrology: Part 3

This report describes the method used by the U.S. Geological Survey to determine the magnitude and frequency of momentary peak discharges at any place on a stream, whether a gaging-station record is available or not. The method is applicable to a region of any size, as a river basin or a State, so long as the region is hydrologically homogeneous. The analysis provides two curves. The first expresses the flood discharge-time relation, showing variation of peak discharge, expressed as a ratio to the mean annual flood, with recurrence interval. The second relates the mean annual flood to the size of drainage area alone, or to the size area and other significant basin characteristics. A frequency curve may be defined for any place in the region by use of these two curves. The procedure is: (a) measure the drainage area and other appropriate basin characteristics from maps; (b) from the second curve, select the mean annual flood corresponding to the proper drainage area factors; (c) from the first curve, select ratios of peak discharge to mean annual flood for selected recurrence intervals, as 2, 10, 25, and 50 years; and (d) multiply these ratios by the mean annual flood and plot the resulting discharges of known frequency to define the frequency curve. Two reports not previously given general circulation are included as sections of this report. These are 'Plotting Positions in Frequency Analysis' by W. B. Langbein, and 'Characteristics of Frequency Curves Based on a Theoretical 1,000-Year Record' by M. A. Benson.

Water Supply Paper↗

Flow origin, drainage area, and hydrologic characteristics for headwater streams in the mountaintop coal-mining region of Southern West Virginia, 2000-01

Characteristics of perennial and intermittent headwater streams were documented in the mountaintop removal coal-mining region of southern West Virginia in 2000?01. The perennial-flow origin points were identified in autumn during low base-flow conditions. The intermittent-flow origin points were identified in late winter and early spring during high base-flow conditions. Results of this investigation indicate that the median drainage area upstream of the origin of intermittent flow was 14.5 acres, and varied by an absolute median of 3.4 acres between the late winter measurements of 2000 and early spring measurements of 2001. Median drainage area in the northeastern part of the study unit was generally larger (20.4 acres), with a lower median basin slope (322 feet per mile) than the southwestern part of the study unit (12.9 acres and 465 feet per mile, respectively). Both of the seasons preceding the annual intermittent flow visits were much drier than normal. The West Virginia Department of Environmental Protection reports that the median size of permitted valley fills in southern West Virginia is 12.0 acres, which is comparable to the median drainage area upstream of the ephemeralintermittent flow point (14.5 acres). The maximum size of permitted fills (480 acres), however, is more than 10 times the observed maximum drainage area upstream of the ephemeral-intermittent flow point (45.3 acres), although a single valley fill may cover more than one drainage area. The median drainage area upstream of the origin of perennial flow was 40.8 acres, and varied by an absolute median of 18.0 acres between two annual autumn measurements. Only basins underlain with mostly sandstone bedrock produced perennial flow. Perennial points in the northeast part of the study unit had a larger median drainage area (70.0 acres) and a smaller median basin slope (416 feet per mile) than perennial points in the southwest part of the study unit (35.5 acres and 567 feet per mile, respectively). Some streams were totally dry for one or both of the annual October visits. Both of the seasons preceding the October visits had near normal to higher than normal precipitation. These dry streams were adjacent to perennial streams draining similarly sized areas, suggesting that local conditions at a firstorder- stream scale determine whether or not there will be perennial flow. Headwater-flow rates varied little from year to year, but there was some variation between late winter and early spring and autumn. Flow rates at intermittent points of flow origin ranged from 0.001 to 0.032 cubic feet per second, with a median of 0.017 cubic feet per second. Flow rates at perennial points of flow origin ranged from 0.001 to 0.14 cubic feet per second, with a median of 0.003 cubic feet per second.

Water-Resources Investigations Report↗

Nutrient loadings to streams of the continental United States from municipal and industrial effluent?

Data from the United States Environmental Protection Agency Permit Compliance System national database were used to calculate annual total nitrogen (TN) and total phosphorus (TP) loads to surface waters from municipal and industrial facilities in six major regions of the United States for 1992, 1997, and 2002. Concentration and effluent flow data were examined for approximately 118,250 facilities in 45 states and the District of Columbia. Inconsistent and incomplete discharge locations, effluent flows, and effluent nutrient concentrations limited the use of these data for calculating nutrient loads. More concentrations were reported for major facilities, those discharging more than 1 million gallons per day, than for minor facilities, and more concentrations were reported for TP than for TN. Analytical methods to check and improve the quality of the Permit Compliance System data were used. Annual loads were calculated using "typical pollutant concentrations" to supplement missing concentrations based on the type and size of facilities. Annual nutrient loads for over 26,600 facilities were calculated for at least one of the three years. Sewage systems represented 74% of all TN loads and 58% of all TP loads. This work represents an initial set of data to develop a comprehensive and consistent national database of point-source nutrient loads. These loads can be used to inform a wide range of water-quality management, watershed modeling, and research efforts at multiple scales.

Journal of the American Water Resources Associatio↗

Connecticut Highlands technical report— Documentation of the regional rainfall-runoff model

This report provides the supporting data and describes the data sources, methodologies, and assumptions used in the assessment of existing and potential water resources of the Highlands of Connecticut and Pennsylvania (referred to herein as the “Highlands”). Included in this report are Highlands groundwater and surface-water use data and the methods of data compilation. Annual mean streamflow and annual mean base-flow estimates from selected U.S. Geological Survey (USGS) gaging stations were computed using data for the period of record through water year 2005. The methods of watershed modeling are discussed and regional and sub-regional water budgets are provided. Information on Highlands surface-water-quality trends is presented. USGS web sites are provided as sources for additional information on groundwater levels, streamflow records, and ground- and surface-water-quality data. Interpretation of these data and the findings are summarized in the Highlands study report.

Connecticut↗

Potentiometric Surface of the Upper Floridan Aquifer, West-central Florida, May 2010

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in May 2010. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the dry season, when groundwater levels usually are at an annual low and withdrawals for agricultural use typically are high. The cumulative average rainfall of 55.21 inches for west-central Florida (from June 2009 through May 2010) was 2.55 inches above the historical cumulative average of 52.66 inches (Southwest Florida Water Management District, 2010). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during the period May 17-21, 2010. Supplemental water-level data were collected by other agencies and companies. Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a 'snapshot' of conditions at a specific time, nor do they necessarily coincide with the seasonal low water-level condition.

Scientific Investigations Map↗

Potentiometric surface of the upper Floridan aquifer, west-central Florida, May 2011

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing freshwater are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in May 2011. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the dry season, when groundwater levels usually are at an annual low and withdrawals for agricultural use typically are high. The cumulative average rainfall of 45.74 inches for west-central Florida (from June 2010 through May 2011) was 6.85 inches below the historical cumulative average of 52.59 inches (Southwest Florida Water Management District, 2011). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September from 1975 through 2010. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during the period May 23-27, 2011. Supplemental water-level data were collected by other agencies and companies. Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a "snapshot" of conditions at a specific time, nor do they necessarily coincide with the seasonal low water-level condition.

Florida↗

Preliminary assessment of channel stability and bed-material transport in the Tillamook Bay tributaries and Nehalem River basin, northwestern Oregon

This report summarizes a preliminary study of bed-material transport, vertical and lateral channel changes, and existing datasets for the Tillamook (drainage area 156 square kilometers [km 2 ]), Trask (451 km 2 ), Wilson (500 km 2 ), Kilchis (169 km 2 ), Miami (94 km 2 ), and Nehalem (2,207 km 2 ) Rivers along the northwestern Oregon coast. This study, conducted in coopera-tion with the U.S. Army Corps of Engineers and Oregon Department of State Lands to inform permitting decisions regarding instream gravel mining, revealed that: Study areas along the six rivers can be divided into reaches based on tidal influence and topography. The fluvial (nontidal or dominated by riverine processes) reaches vary in length (2.4-9.3 kilometer [km]), gradient (0.0011-0.0075 meter of elevation change per meter of channel length [m/m]), and bed-material composition (a mixture of alluvium and intermittent bedrock outcrops to predominately alluvium). In fluvial reaches, unit bar area (square meter of bar area per meter of channel length [m 2 /m]) as mapped from 2009 photographs ranged from 7.1 m 2 /m on the Tillamook River to 27.9 m 2 /m on the Miami River. In tidal reaches, all six rivers flow over alluvial deposits, but have varying gradients (0.0001-0.0013 m/m) and lengths affected by tide (1.3-24.6 km). The Miami River has the steepest and shortest tidal reach and the Nehalem River has the flattest and longest tidal reach. Bars in the tidal reaches are generally composed of sand and mud. Unit bar area was greatest in the Tidal Nehalem Reach, where extensive mud flats flank the lower channel. Background factors such as valley and channel confinement, basin geology, channel slope, and tidal extent control the spatial variation in the accumulation and texture of bed material. Presently, the Upper Fluvial Wilson and Miami Reaches and Fluvial Nehalem Reach have the greatest abundance of gravel bars, likely owing to local bed-material sources in combination with decreasing channel gradient and valley confinement. Natural and human-caused disturbances such as mass movements, logging, fire, channel modifications for navigation and flood control, and gravel mining also have varying effects on channel condition, bed-material transport, and distribution and area of bars throughout the study areas and over time. Existing datasets include at least 16 and 18 sets of aerial and orthophotographs that were taken of the study areas in the Tillamook Bay tributary basins and Nehalem River basin, respectively, from 1939 to 2011. These photographs are available for future assessments of long-term changes in channel condition, bar area, and vegetation establishment patterns. High resolution Light Detection And Ranging (LiDAR) surveys acquired in 2007-2009 could support future quantitative analyses of channel morphology and bed-material transport in all study areas. A review of deposited and mined gravel volumes reported for instream gravel mining sites shows that bed-material deposition tends to rebuild mined bar surfaces in most years. Mean annual deposition volumes on individual bars exceeded 3,000 cubic meters (m 3 ) on Donaldson Bar on the Wilson River, Dill Bar on the Kilchis River, and Plant and Winslow Bars on the Nehalem River. Cumulative reported volumes of bed-material deposition were greatest at Donaldson and Dill Bars, totaling over 25,000 m 3 per site from 2004 to 2011. Within this period, reported cumulative mined volumes were greatest for the Donaldson, Plant, and Winslow Bars, ranging from 24,470 to 33,940 m 3 . Analysis of historical stage-streamflow data collected by the U.S. Geological Survey on the Wilson River near Tillamook (14301500) and Nehalem River near Foss (14301000) shows that these rivers have episodically aggraded and incised, mostly following high flow events, but they do not exhibit systematic, long-term trends in bed elevation. Multiple cross sections show that channels near bridge crossings in all six study areas are dynamic with many subject to incision and aggradation as well as lateral shifts in thalweg position and bank deposition and erosion. In fluvial reaches, unit bar area declined a net 5.3-83.6 percent from 1939 to 2009. The documented reduction in bar area may be attributable to several factors, including vegetation establishment and stabilization of formerly active bar surfaces, lateral channel changes and resulting alterations in sediment deposition and erosion patterns, and streamflow and/or tide differences between photographs. Other factors that may be associated with the observed reduction in bar area but not assessed in this reconnaissance level study include changes in the sediment and hydrology regimes of these rivers over the analysis period. In tidal reaches, unit bar area increased on the Tillamook and Nehalem Rivers (98.0 and 14.7 percent, respectively), but declined a net 24.2 to 83.1 percent in the other four tidal reaches. Net increases in bar area in the Tidal Tillamook and Nehalem Reaches were possibly attributable to tidal differences between the photographs as well as sediment deposition behind log booms and pile structures on the Tillamook River between 1939 and 1967. The armoring ratio (ratio of the median grain sizes of a bar's surface and subsurface layers) was 1.6 at Lower Waldron Bar on the Miami River, tentatively indicating a relative balance between transport capacity and sediment supply at this location. Armoring ratios, however, ranged from 2.4 to 5.5 at sites on the Trask, Wilson, Kilchis, and Nehalem Rivers; these coarse armor layers probably reflect limited bed-material supply at these sites. On the basis of mapping results, measured armoring ratios, and channel cross section surveys, preliminary conclusions are that the fluvial reaches on the Tillamook, Trask, Kilchis, and Nehalem Rivers are currently sediment supply-limited in terms of bed material - that is, the transport capacity of the channel generally exceeds the supply of bed material. The relation between transport capacity and sediment is more ambiguous for the fluvial reaches on the Wilson and Miami Rivers, but transport-limited conditions are likely for at least parts of these reaches. Some of these reaches have possibly evolved from sediment supply-limited to transport-limited over the last several decades in response to changing basin and climate conditions. Because of exceedingly low gradients, all the tidal reaches are transport-limited. Bed material in these reaches, however, is primarily sand and finer grain-size material and probably transported as suspended load from upstream reaches. These reaches will be most susceptible to watershed conditions affecting the supply and transport of fine sediment. Compared to basins on the southwestern Oregon coast, such as the Chetco and Rogue River basins, these six basins likely transport overall less gravel bed material. Although tentative in the absence of actual transport measurements, this conclusion is supported by the much lower area and frequency of bars and longer tidal reaches along all the northcoast rivers examined in this study. Previous studies suggest that the expansive and largely unvegetated bars visible in the 1939 photographs are primarily associated with voluminous sedimentation starting soon after the first Tillamook Burn fire in 1933. However, USGS studies of temporal bar trends in other Oregon coastal rivers unaffected by the Tillamook Burn show similar declines in bar area over approximately the same analysis period. In the Umpqua and Chetco River basins, historical declines in bar area are associated with long-term decreases in flood magnitude. Other factors may include changes in the type and volume of large wood and riparian vegetation. Further characterization of hydrology patterns in these basins and possible linkages with climate factors related to flood peaks, such as the Pacific Decadal Oscillation, could support inferences of expected future changes in vegetation establishment and channel planform and profile. More detailed investigations of bed-material transport rates and channel morphology would support assessments of lateral and vertical channel condition and longitudinal trends in bed material. Such assessments would be most practical for the fluvial study areas on the Wilson, Kilchis, Miami, and Nehalem Rivers and relevant to several ongoing management and ecological issues pertaining to sand and gravel transport. Tidal reaches may also be logical subjects for indepth analysis where studies would be more relevant to the deposition and transport of fine sediment (and associated channel and riparian conditions and processes) rather than coarse bed material.

Oregon↗

Ground-water development and the effects on ground-water levels and water quality in the town of Atherton, San Mateo County, California

The installation of at least 100 residential wells in the town of Atherton, California, during the 198792 drought has raised concerns about the increased potential for land subsidence and salt water intrusion. Data were collected and monitor ing networks were established to assess current processes and to monitor future conditions affect ing these processes. Data include recorded pump age, recorded operation time, and measured pumpage rates from 38 wells; water levels from 49 wells; water chemistry samples from 20 wells, and land-surface elevation data from 22 survey sites, including one National Geodetic Survey estab lished bench mark. Geologic, lithologic, climato logic, well construction, well location, and historical information obtained from available reports and local, state, and Federal agencies were used in this assessment. Estimates of annual residential pumpage from 269 assumed active residential wells in the study area indicate that the average annual total pumping rate is between 395 and 570 acre-feet per year. The nine assumed active institutional wells are estimated to pump a total of about 200 acre- feet per year, or 35 to 50 percent of the total resi dential pumpage. Assuming that 510 acre-feet per year is the best estimate of annual residential pumpage, total pumpage of 710 acre-feet per year would represent about 19 percent of the study area's total water supply, as estimated. Depth-to-water-level measurements in wells during April 1993 through September 1995 typically ranged from less than 20 feet below land surface nearest to San Francisco Bay to more than 70 feet below land surface in upslope areas near exposed bedrock, depending on the season. This range, which is relatively high historically, is attributed to above normal rainfall between 1993 and 1995. Water levels expressed as hydraulic heads indicate the presence of three different hydrologic subareas on the basis of hydraulic-head contour configurations and flow direction. That all measured hydraulic heads in the study area from April 1993 through September 1995 were above sea level indicates that saltwater intrusion was unlikely during this period. The chemistry of 20 well-water samples is characterized as a calcium magnesium carbonate bicarbonate type water. There is no evidence of saltwater intrusion from San Francisco Bay; how ever, water samples from wells nearest the bay and bedrock assemblages indicate a greater concentra tion of dissolved constituents and salinity. Dissolved-solids concentrations of water samples from wells in these areas exceeded 1,000 milli grams per liter, and several samples contained a substantial fraction of sodium and chloride. Water hardness for the 20 wells sampled averaged 471 milligrams per liter as calcium carbonate, which is classified as very hard. One well sample exceeded the primary maximum contaminant level for drinking water in nitrate, several wells exceeded the secondary maximum contaminant level for chloride and sulfate, and all wells sampled exceeded the secondary maximum contaminant level for total dissolved solids. Land-subsidence and the resultant damage because of excessive ground-water pumping, in combination with periodic drought, have a well- documented history in the south San Francisco Bay area. Land-elevation surveying data from 1934 to 1967 indicate that subsidence ranged from 0.1 to approximately 0.5 foot in the vicinity of the study area. It could not be determined from land- surface elevation surveying data from 1993 whether subsidence is currently occurring in the study area.

Water-Resources Investigations Report↗

Water resources inventory of Connecticut Part 6: Upper Housatonic River basin

The upper Housatonic River basin report area has an abundant supply of water of generally good quality, which is derived from precipitation on the area and streams entering the area. Annual precipitation has averaged about 46 inches over a 30-year period. Of this, approximately 22 inches of water is returned to the atmosphere each year by evaporation and transpiration; the remainder flows overland to streams or percolates downward to the water table and ultimately flows out of the report area in the Housatonic River or in smaller streams tributary to the Hudson River. During the autumn and winter precipitation normally is sufficient to cause a substantial increase in the amount of water stored in surface reservoirs and in aquifers, whereas in the summer, losses through evaporation and transpiration result in sharply reduced streamflow and lowered ground-water levels. Mean monthly storage of water in November is 2.8 inches more than it is in June. The amount of water that flows into, through, and out of the report area represents the total amount potentially available for use ignoring reuse. For the 30-year period 1931 through 1960, the annual runoff from precipitation has averaged 24 inches (294 billion gallons). During the same period, inflows from Massachusetts and New York have averaged 220 and 64 billion gallons per year, respectively. A total average annual runoff of 578 billion gallons is therefore available. Although runoff indicates the total amount of water potentially available, it is rarely feasible to use all of it. On the other hand, with increased development, some water may be reused several times. The water availability may be tapped as it flows through the area or is temporarily stored in streams, lakes, and aquifers. The amounts that can be developed differ from place to place and time to time, depending on the amount of precipitation, on the size of drainage area, on the thickness, transmissivity, and areal extent of aquifers, and on the variations in chemical and physical quality of water. Differences in precipitation cause differences in the amount of streamflow whereas differences in the proportion of stratified drift affect its timing. Water can be obtained from wells almost anywhere in the area, but the amount obtainable at any particular point depends on the type and water-bearing properties of the aquifers tapped. Stratified-drift aquifers are the only ones generally capable of yielding more than 100 gpm (gallons per minute) to individual wells. Drilled, screened wells tapping this unit yield from 17 to 1,400 gpm, with a median yield of 200 gpm. Till and bedrock are widespread but generally provide only small supplies of water. Till is tapped in a few places by dug wells, which can yield small supplies of only a few hundred gallons per day throughout all or most of the year. Bedrock is the chief aquifer for privately owned domestic and rural supplies; it is tapped by drilled wells, about 90 percent of which will supply at least 2 gpm. Only 1 of 10 bedrock wells, however, will supply more than 30 gpm. The amount of ground water potentially available in the report area depends upon the thickness and hydraulic properties of aquifers, the amount of salvageable natural discharge of ground water, and the quantity of water available by induced infiltration from streams and lakes. From data on transmissivity, thickness, recharge, well performance, and streamflow, preliminary estimates of ground-water availability can be made for most stratified-drift aquifers in the report area. Long-term yields estimated for eight areas of stratified drift especially favorable for development of large ground-water supplies ranged from 0.6 to 5 mgd (million gallons per day). Detailed site studies are needed to verity these estimates and to determine optimum yields, drawdowns, and spacing of individual wells before major ground-water development is undertaken in these or other areas. The chemical quality of water in the report area is generally good; carbonate-bedrock units exert considerable local influence on water quality. Samples of naturally occurring surface water collected at 24 sites during low flow averaged 90 mg/l (milligrams per liter) dissolved solids and 60 mg/l hardness. Water from wells is generally more highly mineralized than naturally occurring water from streams. About 37 percent of the wells sampled yielded water with more than 200 mg/l dissolved solids and 50 percent yielded water with more than 120 mg/l hardness. These concentrations reflect the high degree of mineralization of ground water in carbonate bedrock and unconsolidated deposits derived from this bedrock. The larger streams, which transport varying amounts of industrial and domestic effluents, averaged about 150 mg/l dissolved solids and 90 mg/l hardness. Iron and manganese concentrations in both ground water and surface water at some places exceed recommended limits for domestic and industrial use. Most wells in the report area yield water with little or no iron or manganese. In certain localities however, the probability is high of encountering water with excessive concentrations of these constituents. Schists, especially the unit in the northwestern corner of the basin, are the likely sources of water with excessive iron and manganese. Iron concentrations in naturally occurring stream water exceed 0.3 mg/l under low-flow conditions at 29 percent of the sites sampled. These excessive concentrations result from discharge of iron-bearing water from aquifers or from swamps where iron is released from decaying vegetation. Water temperature in the larger streams ranges from 0°C (degrees Celsius) to about 28°C. Ground water between 30 feet and 200 feet below the land surface has a relatively constant temperature, usually between 8°C and 11°C. The quantity of suspended sediment transported by streams under natural conditions is negligible. Even in streams affected by man, turbidity is rarely a problem. The total amount of water used in the report area for all purposes during 1967 was about 6,360 million gallons, or 140 gpd per person. Public supplies furnished the domestic needs of nearly half the population of the area. All of the 14 public supplies sampled provided water that meets the drinking water standards of the U.S. Public Health Service.

Connecticut↗

Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, September 2006

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing freshwater are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in September 2006. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the wet season, when ground-water levels usually are at an annual high and withdrawals for agricultural use typically are low. The cumulative average rainfall of 46.06 inches for west-central Florida (from October 2005 through September 2006) was 6.91 inches below the historical cumulative average of 52.97 inches (Southwest Florida Water Management District, 2006). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during September 18-22, 2006. Supplemental water-level data were collected by other agencies and companies. A corresponding potentiometric-surface map was prepared for areas east and north of the Southwest Florida Water Management District boundary by the U.S. Geological Survey office in Orlando, Florida (Kinnaman, 2007). Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a 'snapshot' of conditions at a specific time, nor do they necessarily coincide with the seasonal high water-level condition.

Open-File Report↗

Potentiometric surface of the Upper Floridan aquifer, west-central Florida, September 2005

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing freshwater are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public-supply, domestic use, irrigation, and brackish-water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in September 2005. The potentiometric surface is an imaginary surface, connecting points of equal altitude to which water will rise in tightly cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the wet season, when ground-water levels usually are at an annual high and withdrawals for agricultural use typically are low. The cumulative average rainfall of 55.19 inches for west-central Florida (from October 2004 through September 2005) was 2.00 inches above the historical cumulative average of 53.19 inches (Southwest Florida Water Management District, 2005). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during the period September 19-23, 2005. Supplemental water-level data were collected by other agencies and companies. A corresponding potentiometric-surface map was prepared for areas east and north of the Southwest Florida Water Management District boundary by the U.S. Geological Survey office in Altamonte Springs, Florida (Kinnaman, 2006). Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a "snapshot" of conditions at a specific time, nor do they necessarily coincide with the seasonal high water-level condition.

Florida↗

Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, May 2007

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in May 2007. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the dry season, when ground-water levels usually are at an annual low and withdrawals for agricultural use typically are high. The cumulative average rainfall of 41.21 inches for west-central Florida (from June 2006 through May 2007) was 11.63 inches below the historical cumulative average of 52.84 inches (Southwest Florida Water Management District, 2007). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during the period May 21-25, 2007. Supplemental water-level data were collected by other agencies and companies. A corresponding potentiometric-surface map was prepared for areas east and north of the Southwest Florida Water Management District boundary by the U.S. Geological Survey office in Orlando, Florida (Kinnaman and Dixon, 2007). Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a 'snapshot' of conditions at a specific time, nor do they necessarily coincide with the seasonal low water-level condition.

Open-File Report↗

Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, September 2007

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in September 2007. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the wet season, when ground-water levels usually are at an annual high and withdrawals for agricultural use typically are low. The cumulative average rainfall of 39.50 inches for west-central Florida (from October 2006 through September 2007) was 13.42 inches below the historical cumulative average of 52.92 inches (Southwest Florida Water Management District, 2007). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during the period September 17-21, 2007. Supplemental water-level data were collected by other agencies and companies. A corresponding potentiometric-surface map was prepared for areas east and north of the Southwest Florida Water Management District boundary by the U.S. Geological Survey office in Orlando, Florida (Kinnaman and Dixon, 2008). Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a 'snapshot' of conditions at a specific time, nor do they necessarily coincide with the seasonal high water-level condition.

Open-File Report↗

Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, May 2008

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in May 2008. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the dry season, when ground-water levels usually are at an annual low and withdrawals for agricultural use typically are high. The cumulative average rainfall of 46.95 inches for west-central Florida (from June 2007 through May 2008) was 5.83 inches below the historical cumulative average of 52.78 inches (Southwest Florida Water Management District, 2008). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during the period May 19-23, 2008. Supplemental water-level data were collected by other agencies and companies. A corresponding potentiometric-surface map was prepared for areas east and north of the Southwest Florida Water Management District boundary by the U.S. Geological Survey office in Orlando, Florida (Kinnaman and Dixon, 2008). Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a 'snapshot' of conditions at a specific time, nor do they necessarily coincide with the seasonal low water-level condition.

Scientific Investigations Map↗

Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, September 2008

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in September 2008. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the wet season, when ground-water levels usually are at an annual high and withdrawals for agricultural use typically are low. The cumulative average rainfall of 50.63 inches for west-central Florida (from October 2007 through September 2008) was 2.26 inches below the historical cumulative average of 52.89 inches (Southwest Florida Water Management District, 2008). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during the period September 15-19, 2008. Supplemental water-level data were collected by other agencies and companies. A corresponding potentiometric-surface map was prepared for areas east and north of the Southwest Florida Water Management District boundary by the U.S. Geological Survey office in Orlando, Florida (Kinnaman and Dixon, 2009). Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a 'snapshot' of conditions at a specific time, nor do they necessarily coincide with the seasonal high water-level condition.

Scientific Investigations Map↗

Mass balance, meteorological, ice motion, surface altitude, and runoff data at Gulkana Glacier, Alaska, 1992 balance year

The 1992 measured winter snow, maximum winter snow, net, and annual balances in the Gulkana Glacier basin were evaluated on the basis of meteorological, hydrological, and glaciological data measured in the basin and are reported herein. Averaged over the glacier, the measured winter snow balance was 0.97 meters on March 26, 1992; the maximum winter snow balance was 1.05 meters on May 19, 1992; the net balance (from September 8, 1991 to August 17, 1992) was -0.29 meters; and the annual balance (October 1, 1991 to September 30, 1992) was -0.38 meters. Ice surface, motion, and altitude changes measured at three index sites document seasonal changes in ice speed and glacier thickness. Annual stream runoff was 1.24 meters averaged over the basin.

Water-Resources Investigations Report↗

Potentiometric Surface of the Upper Floridan Aquifer, West-Central Florida, May 2009

The Floridan aquifer system consists of the Upper and Lower Floridan aquifers separated by the middle confining unit. The middle confining unit and the Lower Floridan aquifer in west-central Florida generally contain highly mineralized water. The water-bearing units containing fresh water are herein referred to as the Upper Floridan aquifer. The Upper Floridan aquifer is the principal source of water in the Southwest Florida Water Management District and is used for major public supply, domestic use, irrigation, and brackish water desalination in coastal communities (Southwest Florida Water Management District, 2000). This map report shows the potentiometric surface of the Upper Floridan aquifer measured in May 2009. The potentiometric surface is an imaginary surface connecting points of equal altitude to which water will rise in tightly-cased wells that tap a confined aquifer system (Lohman, 1979). This map represents water-level conditions near the end of the dry season, when ground-water levels usually are at an annual low and withdrawals for agricultural use typically are high. The cumulative average rainfall of 48.53 inches for west-central Florida (from June 2008 through May 2009) was 4.12 inches below the historical cumulative average of 52.65 inches (Southwest Florida Water Management District, 2009). Historical cumulative averages are calculated from regional rainfall summary reports (1915 to most recent complete calendar year) and are updated monthly by the Southwest Florida Water Management District. This report, prepared by the U.S. Geological Survey in cooperation with the Southwest Florida Water Management District, is part of a semi-annual series of Upper Floridan aquifer potentiometric-surface map reports for west-central Florida. Potentiometric-surface maps have been prepared for January 1964, May 1969, May 1971, May 1973, May 1974, and for each May and September since 1975. Water-level data are collected in May and September each year to show the approximate annual low and high water-level conditions, respectively. Most of the water-level data for this map were collected by the U.S. Geological Survey during the period May 18-22, 2009. Supplemental water-level data were collected by other agencies and companies. A corresponding potentiometric-surface map was prepared for areas east and north of the Southwest Florida Water Management District boundary by the U.S. Geological Survey office in Orlando, Florida (Kinnaman and Dixon, 2009). Most water-level measurements were made during a 5-day period; therefore, measurements do not represent a 'snapshot' of conditions at a specific time, nor do they necessarily coincide with the seasonal low water-level condition. The potentiometric contours are generalized to synoptically portray the head in a dynamic hydrologic system, taking due account of the variations in hydrogeologic conditions, such as differing depths of wells, nonsimultaneous measurements of water levels, variable effects of pumping, and changing climatic influence. The potentiometric contours may not conform exactly with the individual measurements of water levels.

Scientific Investigations Map↗

Hydrogeology, numerical simulation of groundwater flow, and effects of future water use and drought for reach 1 of the Washita River alluvial aquifer, Roger Mills and Custer Counties, western Oklahoma, 1980–2015

The Washita River alluvial aquifer is a valley-fill and terrace alluvial aquifer along the valley of the Washita River in western Oklahoma that provides a productive source of groundwater for agricultural irrigation and water supply. The Oklahoma Water Resources Board (OWRB) has designated the westernmost section of the aquifer in Roger Mills and Custer Counties, Okla., as reach 1 of the Washita River alluvial aquifer; reach 1 is the focus of this report. The OWRB issued an order on November 13, 1990, that established the maximum annual yield (MAY; 120,320 acre-feet per year [acre-ft/yr]) and equal-proportionate-share (EPS) pumping rate (2.0 acre-feet per acre per year [(acre-ft/acre)/yr]) for reach 1 of the Washita River alluvial aquifer. The MAY and EPS were based on hydrologic investigations that evaluated the effects of potential groundwater withdrawals on groundwater availability in the Washita River alluvial aquifer. Every 20 years, the OWRB is statutorily required to update the hydrologic investigation on which the MAY and EPS were based. Because 30 years have elapsed since the last order was issued, the U.S. Geological Survey, in cooperation with the OWRB, conducted a new hydrologic investigation and evaluated the effects of potential groundwater withdrawals on groundwater flow and availability in the Washita River alluvial aquifer. The Washita River is the primary source of inflow to Foss Reservoir, a Bureau of Reclamation reservoir constructed in 1961 for flood control, water supply, and recreation. Foss Reservoir provides water for Bessie, Clinton, New Cordell, and Hobart, Okla. Nearly 98 percent of the total groundwater use from the Washita River alluvial aquifer during 1967 to 2015 was for irrigation; other uses of groundwater in the study area include public supply, mining, and agriculture. A hydrogeologic framework was developed for the Washita River alluvial aquifer and included the physical characteristics of the aquifer, the geologic setting, the hydraulic properties of hydrogeologic units, the potentiometric surface (water table), and groundwater-flow directions at a scale that captures the regional controls on groundwater flow. The Washita River alluvial aquifer consists of alluvium and terrace deposits that were transported primarily by water and range from clay to gravel in size. The terrace includes windblown deposits of silt size and, in some cases, contains gravel laid down at several levels along former courses of present-day rivers. A conceptual flow model is a simplified description of the aquifer system that includes hydrologic boundaries, major inflow and outflow sources of the groundwater-flow system, and a conceptual water budget with the estimated mean flows between those hydrologic boundaries. During the study period 1980–2015, mean annual groundwater withdrawals, predominantly used for agricultural irrigation, totaled 5,502 acre-ft/yr, or 14 percent of aquifer outflows. When applied across the 132-square-mile aquifer area used for modeling purposes (84,366 acres), mean annual recharge of 3.15 inches per year corresponds to a mean annual recharge volume of 22,169 acre-ft/yr, or 56 percent of aquifer inflows. The annual saturated-zone evapotranspiration outflow was 11,828 acre-ft/yr for the Washita River alluvial aquifer, or about 30 percent of aquifer outflows. For the Washita River alluvial aquifer, lateral flow was 17,157 acre-ft/yr, or 44 percent of the aquifer inflows. The conceptual flow model and hydrogeologic framework were used to conceptualize, design, and build the numerical groundwater-flow model. A numerical groundwater-flow model of the Washita River alluvial aquifer was constructed by using MODFLOW-2005. The Washita River alluvial aquifer groundwater-model grid was spatially discretized into 350-foot (ft) cells and two layers. Layer 1 represented the undifferentiated alluvium and terrace deposits of Quaternary age, and layer 2 represented the bedrock of Permian age, which was given a uniform nominal thickness of 100 ft. The groundwater-simulation period was temporally discretized into 433 monthly transient stress periods, representing January 1980 to December 2015. An initial 365-day steady-state stress period was configured to represent mean annual inflows and outflows from the Washita River alluvial aquifer for the study period. The groundwater-flow model was calibrated manually and by automated adjustment of model inputs by using PEST++. Calibration targets for the Washita River alluvial aquifer model included groundwater-level observations and reservoir-stage observations, as well as base-flow and stream-seepage estimates. Three groundwater-availability scenarios were used in the calibrated groundwater model to (1) estimate the EPS pumping rate that retains the saturated thickness that meets the minimum 20-year life of the aquifer, (2) quantify the effects of projected pumping rates on groundwater storage over a 50-year period, and (3) evaluate how projected pumping rates extended 50 years into the future and sustained hypothetical drought conditions over a 10-year period affect base flow and groundwater in storage. The results of the groundwater-availability scenarios could be used by the OWRB to reevaluate the established MAY of groundwater from the Washita River alluvial aquifer. EPS scenarios for the Washita River alluvial aquifer were run for periods of 20, 40, and 50 years. The 20-, 40-, and 50-year EPS pumping rates under normal recharge conditions were 1.7, 1.6, and 1.6 (acre-ft/acre)/yr, respectively. Given the aquifer area used for modeling purposes (84,366 acres), these rates correspond to annual yields of 142,579, 134,986, and 134,986 acre-ft/yr, respectively. Groundwater storage at the end of the 20-year EPS scenario was about 281,000 acre-feet (acre-ft), or about 306,000 acre-ft (52 percent) less than the starting storage. Considering the land-surface area of the Washita River alluvial aquifer and using a specific yield of 0.12, this decrease in storage was equivalent to a mean groundwater-level decline of about 30 ft. The Washita River downstream from Foss Reservoir and most of the streams in the study area were dry at the end of the 20-year EPS scenario. Foss Reservoir stage was below the dead-pool stage of 1,597 ft after about 7 years of pumping in the 20-year EPS scenario. Four projected 50-year groundwater-use scenarios were used to simulate the effects of selected well withdrawal rates on groundwater storage in the Washita River alluvial aquifer. These four scenarios used (1) no groundwater use, (2) groundwater use at the 2015 pumping rate, (3) mean groundwater use for the simulation period, and (4) increasing groundwater use. Groundwater storage after 50 years with no groundwater use was 545,249 acre-ft, or 693 acre-ft (0.1 percent) greater than the initial groundwater storage; this groundwater storage increase is equivalent to a mean groundwater-level increase of 0.1 ft. Groundwater storage at the end of the 50-year period with 2015 pumping rates was 543,831 acre-ft, or 723 acre-ft (0.1 percent) less than the initial storage; this groundwater storage decrease is equivalent to a mean groundwater-level decrease of 0.1 ft. Groundwater storage after 50 years with the mean pumping rate for the study period was 543,202 acre-ft, or 1,349 acre-ft (0.2 percent) less than the initial groundwater storage; this groundwater storage decrease is equivalent to a mean groundwater-level decrease of 0.1 ft. Groundwater storage at the end of the 50-year period with an increasing demand groundwater-pumping rate, which was 38 percent greater than the 2015 groundwater-pumping rate, was 542,584 acre-ft, or 1,967 acre-ft (0.4 percent) less than the initial storage; this groundwater storage decrease is equivalent to a mean groundwater-level decrease of 0.2 ft. A hypothetical 10-year-drought scenario was used to simulate the effects of a prolonged period of reduced recharge on groundwater storage in the Washita River alluvial aquifer and Foss Reservoir stage and storage. To simulate the hypothetical drought, recharge in the calibrated model was reduced by 50 percent during the simulated drought period (1983–1992). Groundwater storage at the end of the drought period in December 1992 was 562,000 acre-ft, or 36,000 acre-ft (6 percent) less than the groundwater storage of the calibrated groundwater model (598,000 acre-ft). At the end of the hypothetical drought, the largest changes in saturated thickness (as great as 43.5 ft) were in the area upgradient from Foss Reservoir, particularly in the terrace at the model boundary. Substantial decreases in the Foss Reservoir stage began during the fall of 1985 in conjunction with base-flow decreases of up to 100 percent at U.S. Geological Survey streamgage 07324200 Washita River near Hammon, Okla. These lake-stage declines outpaced groundwater-level declines in the surrounding aquifer. The minimum Foss Reservoir storage simulated during the drought period was 77,954 acre-ft, which was a decrease of 46 percent from the nondrought storage.

Oklahoma↗