Search USGSSearch

SEARCH · Search USGS

Results for “Optical Spectra”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

74 records · Page 5Linked to original sources

A novel non-destructive workflow for examining germanium and co-substituents in ZnS

A suite of complementary techniques was used to examine germanium (Ge), a byproduct critical element, and co-substituent trace elements in ZnS and mine wastes from four mineral districts where germanium is, or has been, produced within the United States. This contribution establishes a comprehensive workflow for characterizing Ge and other trace elements, which captures the full heterogeneity of samples through extensive pre-characterization. This process proceeded from optical microscopy, to scanning electron microscopy and cathodoluminescence (CL) imaging, to electron microprobe analysis, prior to synchrotron-based investigations. Utilizing non-destructive techniques enabled reanalysis, which proved essential for verifying observations and validating unexpected results. In cases where the Fe content was <0.3 wt% in ZnS, cathodoluminescence imaging proved to be an efficient means to qualitatively identify trace element zonation that could then be further explored by other micro-focused techniques. Micro-focused X-ray diffraction was used to map the distribution of the non-cubic ZnS polymorph, whereas micro-focused X-ray fluorescence (μ-XRF) phase mapping distinguished between Ge 4+ hosted in primary ZnS and a weathering product, hemimorphite [Zn 4 Si 2 O 7 (OH) 2 ·H 2 O]. Microprobe data and μ-XRF maps identified spatial relationships among trace elements in ZnS and implied substitutional mechanisms, which were further explored using Ge and copper (Cu) X-ray absorption near-edge spectroscopy (XANES). Both oxidation states of Ge (4+ and 2+) were identified in ZnS along with, almost exclusively, monovalent Cu. However, the relative abundance of Ge oxidation states varied among mineral districts and, sometimes, within samples. Further, bulk XANES measurements typically agreed with micro-focused XANES (μ-XANES) spectra, but unique micro-environments were detected, highlighting the importance of complementary bulk and micro-focused measurements. Some Ge μ-XANES utilized a high energy resolution fluorescence detector, which improved spectral resolution and spectral signal-to-noise ratio. This detector opens new opportunities for exploring byproduct critical elements in complex matrices. Overall, the non-destructive workflow employed here can be extended to other byproduct critical elements to more fully understand fundamental ore enrichment processes, which have practical implications for critical element exploration, resource quantification, and extraction.

Frontiers in Earth Science

Procedures for using the Horiba Scientific Aqualog ® fluorometer to measure absorbance and fluorescence from dissolved organic matter

Advances in spectroscopic techniques have led to an increase in the use of optical measurements (absorbance and fluorescence) to assess dissolved organic matter composition and infer sources and processing. Although optical measurements are easy to make, they can be affected by many variables rendering them less comparable, including by inconsistencies in sample collection (for example, filter pore size, preservation), the application of corrections for interferences (for example, inner-filtering corrections), differences in holding times, and instrument drift (for example, lamp intensity). A documented, standardized procedure to address these variables ensures that the optical (absorbance and fluorescence) measurements collected by U.S. Geological Survey researchers are useful and widely comparable. Rigorous and quantifiable quality assurance and quality control are essential for making these data comparable, particularly because there is no published guideline for the measurement of dissolved organic matter absorbance and fluorescence, and especially because there is no National Institute of Standards and Technology standard for dissolved organic matter. Validation and quality-control samples are analyzed on a monthly basis to determine laboratory and instrument precision and daily (that is, each day samples are run) to ensure repeatability. Data are not considered acceptable unless they meet laboratory criteria: All standards should be within 10 percent of the target value, laboratory replicates should be within 5 percent relative percent difference, and laboratory blanks (that is, laboratory reagent-grade water) should be less than one-tenth of the long-term method detection limit. Finally, for data to be useful, they must be accessible to users in a format that can be easily analyzed and interpreted. The Organic Matter Research Laboratory staff has developed a processing routine that extracts a subset of the data, which is made available to the public through the USGS National Water Quality Information System ( http://nwis.waterdata.usgs.gov/usa/nwis/qwdata ), and organizes the full datasets (that is, complete absorbance spectra and fluorescence excitation-emission matrices) in different forms that allow for these data to be analyzed using multi-parameter and multi-way statistical approaches.

Open-File Report