Search USGS⌕ Search

SEARCH · Search USGS

Results for “Ground Water Modeling Investigation Report”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39Linked to original sources

Determination of infiltration and percolation rates along a reach of the Santa Fe River near La Bajada, New Mexico

Two methods, one a surface-water method and the second a ground-water method, were used to determine infiltration and percolation rates along a 2.5-kilometer reach of the Santa Fe River near La Bajada, New Mexico. The surface-water method uses streamflow measurements and their differences along a stream reach, streamflow-loss rates, stream surface area, and evaporation rates to determine infiltration rates. The ground-water method uses heat as a tracer to monitor percolation through shallow streambed sediments. Data collection began in October 1996 and continued through December 1997. During that period the stream reach was instrumented with three streamflow gages, and temperature profiles were monitored from the stream-sediment interface to about 3 meters below the streambed at four sites along the reach. Infiltration is the downward flow of water through the stream- sediment interface. Infiltration rates ranged from 92 to 267 millimeters per day for an intense measurement period during June 26- 28, 1997, and from 69 to 256 millimeters per day during September 27-October 6, 1997. Investigators calculated infiltration rates from streamflow loss, stream surface-area measurements, and evaporation-rate estimates. Infiltration rates may be affected by unmeasured irrigation-return flow in the study reach. Although the amount of irrigation-return flow was none to very small, it may result in underestimation of infiltration rates. The infiltration portion of streamflow loss was much greater than the evaporation portion. Infiltration accounted for about 92 to 98 percent of streamflow loss. Evaporation-rate estimates ranged from 3.4 to 7.6 millimeters per day based on pan-evaporation data collected at Cochiti Dam, New Mexico, and accounted for about 2 to 8 percent of streamflow loss. Percolation is the movement of water through saturated or unsaturated sediments below the stream-sediment interface. Percolation rates ranged from 40 to 109 millimeters per day during June 26-28, 1997. Percolation rates were not calculated for the September 27-October 6, 1997, period because a late summer flood removed the temperature sensors from the streambed. Investigators used a heat-and-water flow model, VS2DH (variably saturated, two- dimensional heat), to calculate near-surface streambed infiltration and percolation rates from temperatures measured in the stream and streambed. Near the stream-sediment interface, infiltration and percolation rates are comparable. Comparison of infiltration and percolation rates showed that infiltration rates were greater than percolation rates. The method used to calculate infiltration rates accounted for net loss or gain over the entire stream reach, whereas the method used to calculate percolation was dependent on point measurements and, as applied in this study, neglected the nonvertical component of heat and water fluxes. In general, using the ground-water method was less labor intensive than making a series of streamflow measurements and relied on temperature, an easily measured property. The ground-water method also eliminated the difficulty of measuring or estimating evaporation from the water surface and was therefore more direct. Both methods are difficult to use during periods of flood flow. The ground-water method has problems with the thermocouple-wire temperature sensors washing out during flood events. The surface- water method often cannot be used because of safety concerns for personnel making wading streamflow measurements.

New Mexico↗

Use of Water-Quality Indicators and Environmental Tracers to Determine the Fate and Transport of Recycled Water in Angeles County, California

Tertiary-treated municipal wastewater (recycled water) has been used to replenish the Central Basin in Los Angeles County for over 40 years. Therefore, this area provides an excellent location to investigate (1) the fate and transport of wastewater constituents as they travel from the point of recharge to points of withdrawal, and (2) the long-term effects that artificial recharge using recycled water has on the quality of the ground-water basin. The U.S. Geological Survey has been conducting such investigations in this area for about 10 years, beginning in 1992. For this investigation, a variety of inorganic, organic, and isotopic constituents were analyzed in samples from 23 production wells within 500 feet of the San Gabriel and Rio Hondo Coastal Basin Spreading Grounds, and tritium/helium-3, chlorofluorocarbons, dissolved gases, and nitrogen isotopes were analyzed in five multiple-well monitoring sites along a 10-mile flow path extending from just upgradient of the spreading grounds southward through the Central Basin. Spearman rank-order correlation coefficients and level of significance calculated for about 40 water-quality indicators and several physical features show significant correlations between numerous inorganic and organic constituents that indicate the presence of wastewater. On the basis of a simple two-member mixing model, chloride, boron, ultraviolet absorbance at 254 nanometers, and excitation-emission fluorescence yielded the most reasonable estimates of wastewater percentages in the production wells. Tritium/helium-3 age determinations indicated that samples of ground water tested range in age from less than 2 to more than 50 years. Chloride and boron concentrations, along with tritium/helium-3 age determinations, indicate more rapid recharge and (or) displacement of pre-existing ground water at the San Gabriel Coastal Basin Spreading Grounds than at the Rio Hondo Coastal Basin Spreading Grounds. Nitrogen-15 enrichment of the ground-water nitrate and dissolved nitrogen indicates that denitrification, an important process for the removal of nitrate at the shallower depths beneath the spreading grounds, continues to occur at distances of several miles from the spreading grounds and over a period of many years. Analysis of dissolved gases shows that areas that contain recycled water have no detectable methane, whereas methane is present in the native ground water older than 50 years. The absence of methane in the younger ground water suggests that artificial recharge using recycled water has the desirable effect of increasing slightly the redox potential of the ground-water basin. Finally, measured chlorofluorocarbon concentrations and tritium/helium-3 age determinations indicate that chlorofluorocarbon concentrations are markedly elevated above atmosphere-water equilibrium in ground water older than about 20 years but still young enough to contain recycled water.

Water-Resources Investigations Report↗

Evaluation of ground-water flow and hydrologic budget for Lake Five-O, a seepage lake in northwestern Florida

Temporal and spatial distributions of ground-water inflow to, and leakage from Lake Five-O, a softwater, seepage lake in northwestern Florida, were evaluated using hydrologic data and simulation models of the shallow ground-water system adjacent to the lake. The simulation models indicate that ground-water inflow to the lake and leakage from the lake to the ground-water system are the dominant components in the total inflow (precipitation plus ground-water inflow) and total outflow (evaporation plus leakage) budgets of Lake Five-O. Simlulated ground-water inflow and leakage were approximately 4 and 5 times larger than precipitation inputs and evaporative losses, respectively, during calendar years 1989-90. Exchanges of water between Lake Five-O and the ground-water system were consistently larger than atmospheric-lake exchanges. A consistent pattern of shallow ground-water inflow and deep leakage was also evident throughout the study period. The mean time of travel from ground-water that discharges at Lake Five-O (time from recharge at the water table to discharge at the lake) was estimated to be within a range of 3 to 6 years. Flow-path evaluations indicated that the intermediate confining unit probably has a negligible influence on the geochemistry of ground-water inflow to Lake Five-O. The hydrologic budgets and flow-path evaluations provide critical information for developing geochemical budgets for Lake Five-O and for improving the understanding of the relative importance of various processes that regulate the acid-neutralizing capacity of softwater seepage lakes in Florida.

Florida↗

Use of Superposition Models to Simulate Possible Depletion of Colorado River Water by Ground-Water Withdrawal

According to the 'Law of the River', wells that draw water from the Colorado River by underground pumping need an entitlement for the diversion of water from the Colorado River. Consumptive use can occur through direct diversions of surface water, as well as through withdrawal of water from the river by underground pumping. To develop methods for evaluating the need for entitlements for Colorado River water, an assessment of possible depletion of water in the Colorado River by pumping wells is needed. Possible methods include simple analytical models and complex numerical ground-water flow models. For this study, an intermediate approach was taken that uses numerical superposition models with complex horizontal geometry, simple vertical geometry, and constant aquifer properties. The six areas modeled include larger extents of the previously defined river aquifer from the Lake Mead area to the Yuma area. For the modeled areas, a low estimate of transmissivity and an average estimate of transmissivity were derived from statistical analyses of transmissivity data. Aquifer storage coefficient, or specific yield, was selected on the basis of results of a previous study in the Yuma area. The USGS program MODFLOW-2000 (Harbaugh and others, 2000) was used with uniform 0.25-mile grid spacing along rows and columns. Calculations of depletion of river water by wells were made for a time of 100 years since the onset of pumping. A computer program was set up to run the models repeatedly, each time with a well in a different location. Maps were constructed for at least two transmissivity values for each of the modeled areas. The modeling results, based on the selected transmissivities, indicate that low values of depletion in 100 years occur mainly in parts of side valleys that are more than a few tens of miles from the Colorado River.

Scientific Investigations Report↗

A modification of the finite-difference model for simulation of two dimensional ground-water flow to include surface-ground water relationships

The two-dimensional finite-difference model for simulation of groundwater flow was modified to enable simulation of surface-water/groundwater interactions during periods of low streamflow. Changes were made to the program code in order to calculate surface-water heads for, and flow either to or from, contiguous surface-water bodies; and to allow for more convenient data input. Methods of data input and output were modified and entries (RSORT and HDRIVER) were added to the COEF and CHECKI subroutines to calculate surface-water heads. A new subroutine CALC was added to the program which initiates surface-water calculations. If CALC is not specified as a simulation option, the program runs the original version. The subroutines which solve the ground-water flow equations were not changed. Recharge, evapotranspiration, surface-water inflow, number of wells, pumping rate, and pumping duration can be varied for any time period. The Manning formula was used to relate stream depth and discharge in surface-water streams. Interactions between surface water and ground water are represented by the leakage term in the ground-water flow and surface-water mass balance equations. Documentation includes a flow chart, data deck instructions, input data, output summary, and program listing. Numerical results from the modified program are in good agreement with published analytical results. (USGS)

Water-Resources Investigations Report↗

Ground-water contamination by crude oil at the Bemidji, Minnesota, research site; US Geological Survey Toxic Waste--ground-water contamination study

The U.S. Geological Survey has begun a research project to improve understanding of the mobilization, transport, and fate of petroleum contaminants in the shallow subsurface and to use this understanding to develop predictive models of contaminant behavior. The project site is near Bemidji in northern Minnesota where an accidental spill of 10,500 barrels of crude oil occurred when a pipeline broke on August 20, 1979. Regulatory and remedial actions have been completed. The site is in a remote area with neither man-made hydraulic stresses nor other anthropogenic sources of the compounds of interest. The spill is in the recharge area of a local flow system that discharges to a small closed lake approximately 1,000 feet down the hydraulic gradient. The aquifer is pitted outwash dissected by younger glacial channels and is underlain by poorly permeable till at a depth of about 80 feet. Ground water dissolves oil floating on the water table under the spill site and moves toward the lake. At the water table, ground water enters the lake through lacustrine sediments; at depth, flow may be underneath the lake through the outwash. Contaminant transport has been as rapid as 4 feet per day based on the rate of movement of contaminants monitored through wells installed within a few days of the spill, but average rates are undoubtedly much less.

Minnesota↗

Ground-water contamination by crude oil at the Bemidji, Minnesota, research site- An introduction: Chapter A in Ground-water contamination by crude oil at the Bemidji, Minnesota, research site; US Geological Survey Toxic Waste--ground-water contamination study

The U.S. Geological Survey has begun a research project to improve understanding of the mobilization, transport, and fate of petroleum contaminants in the shallow subsurface and to use this understanding to develop predictive models of contaminant behavior. The project site is near Bemidji in northern Minnesota where an accidental spill of 10,500 barrels of crude oil occurred when a pipeline broke on August 20, 1979. Regulatory and remedial actions have been completed. The site is in a remote area with neither man-made hydraulic stresses nor other anthropogenic sources of the compounds of interest. The spill is in the recharge area of a local flow system that discharges to a small closed lake approximately 1,000 feet down the hydraulic gradient. The aquifer is pitted outwash dissected by younger glacial channels and is underlain by poorly permeable till at a depth of about 80 feet. Ground water dissolves oil floating on the water table under the spill site and moves toward the lake. At the water table, ground water enters the lake through lacustrine sediments; at depth, flow may be underneath the lake through the outwash. Contaminant transport has been as rapid as 4 feet per day based on the rate of movement of contaminants monitored through wells installed within a few days of the spill, but average rates are undoubtedly much less.

Minnesota↗

Hydrogeology and water quality in the Cedar Rapids area, Iowa, 1992-96

The U.S. Geological Survey (USGS) and the city of Cedar Rapids conducted a cooperative study from 1992 to 1996 to assess the hydrogeology and water quality in the Cedar River, Cedar River alluvial aquifer, Devonian aquifer, and Silurian aquifer in a 231-square-mile area of Benton and Linn Counties near Cedar Rapids, Iowa. The city of Cedar Rapids withdrew an average of 34 million gallons per day between July 1,1995, and June 30, 1996, from the Cedar River alluvial aquifer for its drinking-water supply. The ground-water flow system in the 231-square-mile area was simulated using a modular, three-dimensional, finite-difference groundwater flow model (MODFLOW) under steady-state conditions. The three-layer groundwater flow model simulates ground-water flow in layer 1 for unconsolidated deposits that include the Cedar River alluvial aquifer; in layer 2 for the Devonian aquifer and buried-channel aquifer; and in layer 3 for the Silurian aquifer. Primary sources of inflow to the ground-water flow system in the model area include infiltration of precipitation (63.5 percent) and leakage from the Cedar River (34.7 percent). Pumpage from municipal, industrial, and private wells accounts for about 48.3 percent of system outflow. Primary sources of inflow to the Cedar River alluvial aquifer include leakage from the Cedar River (74.2 percent), leakage from adjacent or underlying hydrogeologic units (20.9 percent), and infiltration of precipitation (4.9 percent). Pumpage by municipal water-supply wells from the alluvial aquifer accounts for about 78.0 percent of system outflow. Simulations of two hypothetical conditions using the steady-state ground-water flow model were conducted to evaluate quantitative changes on sources of water to the Cedar River alluvial aquifer. Results for the scenario representing a period of less-than-average annual precipitation for 1961-90 indicate a 32.0-percent reduction of total ground-water flow and a 5.7-percent increase in river leakage to the Cedar River alluvial aquifer. Results for the scenario representing increased pumping from the Cedar River alluvial aquifer, with pumping increased 68.3 percent from about 41 million gallons per day (for the calibrated model) to about 70 million gallons per day, indicate a 70.9-percent increase in simulated river leakage. Commonly used herbicides in Iowa such as atrazine (and the metabolite products deethylatrazine and deisopropylatrazine), cyanazine, and metolachlor, when detected in the Cedar River alluvial aquifer, were typically at small concentrations (less than 1.0 microgram per liter). Atrazine concentrations in 26 of the 64 wells sampled were less than the 0.05 microgram per liter minimum reporting level. Most ground-water samples collected from the Devonian and Silurian aquifers had herbicide concentrations less than 0.05 microgram per liter. Nitrite-plus-nitrate nitrogen (nitrate) concentrations in ground-water samples varied from less than the minimum reporting level (0.05 milligram per liter) to 15.0 milligrams per liter. Nitrate was not detected in samples from 18 wells, and nitrate concentrations greater than the Maximum Contaminant Level for nitrate as nitrogen (10 milligrams per liter) were detected in samples from 4 wells. Several areas in the Cedar River alluvial aquifer with large iron and manganese concentrations could be related to the original depositional environment of the sediment. In general, large iron and manganese concentrations in ground water are often associated with abundant organic and argillaceous material in sediment near old meander channels and sloughs.

Iowa↗

Geohydrology of the Central Oahu, Hawaii, ground-water flow system and numerical simulation of the effects of additional pumping

A two-dimensional, finite-difference, ground-water flow model was developed for the central Oahu flow system, which is the largest and most productive ground-water flow system on the island. The model is based on the computer code SHARP which simulates both freshwater and saltwater flow. The ground-water model was developed using average pumping and recharge conditions during the 1950's, which was considered to be a steady-state period. For 1950's conditions, model results indicate that 62 percent (90.1 million gallons per day) of the discharge from the Schofield ground-water area flows southward and the remaining 38 percent (55.2 million gallons per day) of the discharge from Schofield flows northward. Although the contribution of recharge from infiltration of rainfall and irrigation water directly on top of the southern and northern Schofield ground-water dams was included in the model, the distribution of natural discharge from the Schofield ground-water area was estimated exclusive of the recharge on top of the dams. The model was used to investigate the long-term effects of pumping under future land-use conditions. Future recharge was conservatively estimated by assuming no recharge associated with agricultural activities. Future pumpage used in the model was based on the 1995-allocated rates. Model results indicate that the long-term effect of pumping at the 1995-allocated rates will be a reduction of water levels from present (1995) conditions in all ground-water areas of the central Oahu flow system. In the Schofield ground-water area, model results indicate that water levels could decline about 30 feet from the 1995 water-level altitude of about 275 feet. In the remaining ground-water areas of the central Oahu flow system, water levels may decline from less than 1 foot to as much as 12 feet relative to 1995 water levels. Model results indicate that the bottoms of several existing deep wells in northern and southern Oahu extend below the model-calculated freshwater-saltwater interface location for the future recharge and pumping conditions. Model results indicate that an additional 10 million gallons per day (beyond the 1995-allocated rates) of freshwater can potentially be developed from northern Oahu. Various distributions of pumping can be used to obtain the additional 10 million gallons per day of water. The quality of the water pumped will be dependent on site-specific factors and cannot be predicted on the basis of model results. If the additional 10 million gallons per day pumpage is restricted to the Kawailoa and Waialua areas, model results indicate that a regional drawdown (relative to the water-level distribution associated with the 1995-allocated pumping rates) of less than 0.6 foot can be maintained in these two areas. The additional pumping, however, would cause salinity increases in water pumped by existing deep wells. In addition, increases in salinity may occur at other wells in areas where the model indicates no significant problem with upconing.

Hawaii↗

Ground-Water Nutrient Flux to Coastal Waters and Numerical Simulation of Wastewater Injection at Kihei, Maui, Hawaii

Water sampling and numerical modeling were used to estimate ground-water nutrient fluxes in the Kihei area of Maui, where growth of macroalgae (seaweed) on coral reefs raises ecologic concerns and accumulation on beaches has caused odor and removal problems. Fluxes and model results are highly approximate, first-order estimates because very few wells were sampled and there are few field data to constrain model calibration. Ground-water recharge was estimated to be 22.6 Mgal/d (million gallons per day) within a 73-square-mile area having a coastline length of 8 miles or 13 km (kilometers). Nearly all of the recharge discharges at the coast because ground-water withdrawals are small. Another 3.0 Mgal/d of tertiary-treated wastewater effluent is injected into the regional aquifer at a County treatment plant midway along the coast and about a mile from shore. The injection plume is 0.93 miles wide (1.5 km) at the shore, as estimated from a three-dimensional numerical ground-water model. Wastewater injected beneath the brackish ground-water lens rises buoyantly and spreads out at the top of the lens, diverting and mixing with ambient ground water. Ground water discharging from the core of the injection plume is less than 5 years old and is about 60 percent effluent at the shore, according to the model. Dissolved nitrogen and phosphorus concentrations in treated effluent were 7.33 and 1.72 milligrams per liter, roughly 6 and 26 times background concentrations at an upgradient well. Background nitrogen and phosphorus fluxes carried by ground water are 7.7 and 0.44 kg/d-km (kilograms per day per kilometer of coast). Injected wastewater fluxes distributed across the plume width are 55 and 13 kg/d-km nitrogen and phosphorus, roughly 7 and 30 times background flux. However, not all of the injected load reaches coastal waters because nutrients are naturally attenuated in the oxygen-depleted effluent plume. Water from a downgradient well reflects this attenuation and provides a more conservative estimate of injection flux approaching the shore: 27 and 1.5 kg/d-km nitrogen and phosphorus, roughly one-half and one-ninth the injection-source estimates, and 3.5 and 3.4 times background flux. Effluent has 8 O and 2 H stable-isotope signatures that are distinct from local ground water, as well as 15 N and 11 B signatures diagnostic of domestic waste and laundry detergents, respectively. Pharmaceuticals and organic wastewater compounds also were present in effluent and the downgradient well. These isotopes and chemicals served as wastewater tracers in Kihei ground water and may be useful tracers in nearshore marine waters and aquifers elsewhere in Hawaii.

Scientific Investigations Report↗

Hydrogeology and Ground-Water Flow in the Opequon Creek Watershed area, Virginia and West Virginia

Due to increasing population and economic development in the northern Shenandoah Valley of Virginia and West Virginia, water availability has become a primary concern for water-resource managers in the region. To address these issues, the U.S. Geological Survey (USGS), in cooperation with the West Virginia Department of Health and Human Services and the West Virginia Department of Environmental Protection, developed a numerical steady-state simulation of ground-water flow for the 1,013-square-kilometer Opequon Creek watershed area. The model was based on data aggregated for several recently completed and ongoing USGS hydrogeologic investigations conducted in Jefferson, Berkeley, and Morgan Counties in West Virginia and Clarke, Frederick, and Warren Counties in Virginia. A previous detailed hydrogeologic assessment of the watershed area of Hopewell Run (tributary to the Opequon Creek), which includes the USGS Leetown Science Center in Jefferson County, West Virginia, provided key understanding of ground-water flow processes in the aquifer. The ground-water flow model developed for the Opequon Creek watershed area is a steady-state, three-layer representation of ground-water flow in the region. The primary objective of the simulation was to develop water budgets for average and drought hydrologic conditions. The simulation results can provide water managers with preliminary estimates on which water-resource decisions may be based. Results of the ground-water flow simulation of the Opequon Creek watershed area indicate that hydrogeologic concepts developed for the Hopewell Run watershed area can be extrapolated to the larger watershed model. Sensitivity analyses conducted as part of the current modeling effort and geographic information system analyses of spring location and yield reveal that thrust and cross-strike faults and low-permeability bedding, which provide structural and lithologic controls, respectively, on ground-water flow, must be incorporated into the model to develop a realistic simulation of ground-water flow in the larger Opequon Creek watershed area. In the model, recharge for average hydrologic conditions was 689 m3/d/km2 (cubic meters per day per square kilometer) over the entire Opequon Creek watershed area. Mean and median measured base flows at the streamflow-gaging station on the Opequon Creek near Martinsburg, West Virginia, were 604,384 and 349,907 m3/d (cubic meters per day), respectively. The simulated base flow of 432,834 m3/d fell between the mean and median measured stream base flows for the station. Simulated base-flow yields for subwatersheds during average conditions ranged from 0 to 2,643 m3/d/km2, and the median for the entire Opequon Creek watershed area was 557 m3/d/km2. A drought was simulated by reducing model recharge by 40 percent, a rate that approximates the recharge during the prolonged 16-month drought that affected the region from November 1998 to February 2000. Mean and median measured streamflows for the Opequon Creek watershed area at the Martinsburg, West Virginia, streamflow-gaging station during the 1999 drought were 341,098 and 216,551 m3/d, respectively. The simulated drought base flow at the station of 252,356 m3/d is within the range of flows measured during the 1999 drought. Recharge was 413 m3/d/km2 over the entire watershed during the simulated drought, and was 388 m3/d/km2 at the gaging station. Simulated base-flow yields for drought conditions ranged from 0 to 1,865 m3/d/km2 and averaged 327 m3/d/km2 over the entire Opequon Creek watershed. Water budgets developed from the simulation results indicate a substantial component of direct ground-water discharge to the Potomac River. This phenomenon had long been suspected but had not been quantified. During average conditions, approximately 564,176 m3/d of base flow discharges to the Potomac River. An additional 124,379 m3/d of ground water is also estimated to discharge directly to the Potomac River and rep

Scientific Investigations Report↗

Mathematical model of San Juan Valley ground-water basin, San Benito County, California

A mathematical model study of the San Juan Valley ground-water basin in San Benito County, Calif., has quantitatively described the ground-water hydrology of the basin under past, present, and future conditions of development. An analysis of conditions in the basin prior to large-scale ground-water development indicates that net recharge equaled 9.23 cubic feet per second and occurred as subsurface flow to the eastern part of the basin and infiltration of rain, direct runoff, and minor streamflows. Net predevelopment discharge equaled 9.23 cubic feet per second and occurred as aquifer discharge to the San Benito River. The 9.23 cubic feet per second of predevelopment recharge is considered to be perennial recharge to the basin. Large-scale ground-water development occurred in the area during the period 1945-68 and caused water levels to decline throughout most of the basin. Progressive depletion of aquifer storage during this period changed the San Benito River from a gaining (perennial) stream to a losing stream along most of its reach in the basin area. Net discharge from the basin during the period 1945-68 averaged 18.10 cubic feet per second. Of this amount 17.82 cubic feet per second occurred as pumpage from wells, and 0.28 cubic foot per second occurred as basin discharge to the San Benito River. Net recharge to the basin during the same period averaged 13.57 cubic feet per second. Of this amount 4.34 cubic feet per second occurred as infiltration from the San Benito River and 9.23 cubic feet per second occurred as perennial recharge. Use of the calibrated mathematical model to simulate quantities of imported water entering the basin from the San Benito River indicates that water levels in San Juan Valley will stabilize or recover when additional recharge equals or exceeds 3,000 acre-feet per year.

California↗

Ground water in Dale Valley, New York

Dale Valley is a broad valley segment, enlarged by glacial erosion, at the headwaters of Little Tonawanda Creek near Warsaw , New York. A thin, shallow alluvial aquifer immediately underlies the valley floor but is little used. A deeper gravel aquifer, buried beneath many feet of lake deposits, is tapped by several industrial wells. A finite-difference digital model treated the deep aquifer as two-dimensional with recharge and discharge through a confining layer. It was calibrated by simulating (1) natural conditions, (2) an 18-day aquifer test, and (3) 91 days of well-field operation. Streamflow records and model simulations suggest that in moderately wet years such as 1974, a demand of 750 gallons per minute could be met by withdrawal from the creek and from the aquifer without excessive drawdown at production wells or existing domestic wells. With reasonable but unverified model adjustments to simulate an unusually dry year, the model predicts that a demand of 600 gallons per minute could be met from the same sources. Water high in chloride has migrated from bedrock into parts of the deep aquifer. Industrial pumpage, faults in the bedrock, and the natural flow system may be responsible. (Woodard-USGS)

Water-Resources Investigations Report↗

Geohydrology and simulation of ground-water flow in the carbonate rocks of the Valley Creek basin, eastern Chester County, Pennsylvania

Sixty-eight percent of the 22.6-square-mile Valley Creek basin is underlain by Cambrian and Ordovician limestone and dolomite. Ground water flows through a network of interconnected secondary openings; primary porosity is virtually nonexistent. Some of these openings have been enlarged by solution. Secondary porosity and permeability exhibit great spatial variability, and the yield and specific capacity of wells are highly variable. The number of water-bearing zones decreases with depth. Fifty percent of water-bearing zones are encountered within 100 feet of the land surface, and 81 percent are within 200 feet. Most ground-water flow in the Valley Creek basin is local and discharges to nearby streams. Ground-water discharge comprised an average of 76 percent of the flow of Valley Creek during 1983--87, including both natural ground- water discharge and quarry pumpage discharged to Valley Creek. Discharge from the Cedar Hollow quarry comprised 21 to 26 percent of the base flow of Valley Creek; the average was 23 percent. The average natural base flow of Valley Creek would be 8 percent lower if the quarry were not operating. Regional ground-water flow is to the northeast to the Schuylkill River. On the western side of the Valley Creek basin, the ground-water divide is 1/2 mile west of the surface-water divide. An estimated 0.75 million gallons per day of ground water flows from the adjacent West Valley Creek basn eastward into the Valley Creek basin. A ground-water divide is not present on the eastern side of the basin; the water table slopes gently eastward toward the Schuylkill River. On the northeaster side, an estimated 1.76 million gallons per day of ground water flows northeastward out of the basin to the Schuylkill River beneath the surface-water divide. On the southeaster side, an estimated 0.85 million gallons per day of ground water flows beneath the surface-water divide into the basin. Annual water budgets and an average water budget were calculated for 1983-87 for the 20.8-square-mile area bove the streamflow-gaging station. Annual precipitation for 1983-87 ranged from 40.61 to 56.55 inches and averaged 47.25 inches; annual streamflow ranged from 15.55 to 28.57 inches and averaged 22.31 inches; annual evapotranspiration ranged from 18.21 to 24.83 inches and averaged 22.90 inches; and annual recharge ranged from 15.89 to 26.84 inches and averaged 21.04 inches. The Valley Creek basin was modeled as a two-dimensional water-table aquifer. Recharge to, ground-water flow through, and discharge from the rocks of Chester valley were simulated. In order to include the natural hydrologic boundaries of the ground-water-flwo system, the 66.4-square-mile area between the Brandywine Creek and the Schuylkill River was modeled. The model was calibrated under stead-state conditions using avareage recharge and evapotranspiration rates. Aquifer hydraulic conductivity was estimated from specific-capacity and quifer-test data. The average (1983-87) annual water budget for hte Valley Creek basin was simualted. The effect of increased ground-water development on base flow and underflow was simulated by locating a hypothetical well field produceing 4 million gallons per day in different parts of the basin. Pumpage from a well field near surface-water divides would induce as much as an additional 1.41 inches per year of underflow from an adjacent surface-water basin. Pumpage from a well field near the center of the basin would affect base flow more than underflow. Increased seepage of ground water into quarries as a result of their expansion was simulated as increased withdrawal by pumping. A 100-percent increase in the pumping rate of the Cedar Hollow quarry, from 3.93 to 7.86 million gallons per day, owuld reduce the natural base flow of Valley Creek by 18 percent. However, the quarry pumpage would be discharged to Valley Creek, thereby increasing the base flow at the gaging station by

Pennsylvania↗

Hydrogeology, ground-water quality, and source of ground water causing water-quality changes in the Davis well field at Memphis, Tennessee

An investigation was conducted by the U.S. Geological Survey from 1992 to 1994 to collect and interpret hydrogeologic and water-quality data to determine the source of ground water causing water-quality changes in water from wells screened in the Memphis aquifer in the Davis well field at Memphis, Tennessee. Water-quality changes in aquifers used for water supply are of concern because these changes can indicate a potential for contamination of the aquifers by downward leakage from near-surface sources. The water-quality changes at the Davis well field were detected by Memphis Light, Gas and Water Division, which has periodically sampled and analyzed water from many of the 14 production wells since the well field began operation in 1971. Memphis Light, Gas and Water Division analyzed the water samples primarily for hardness, alkalinity, chloride, ulfate, and iron. Results of the e analy es and results of more recent (1992) analyse of water samples by the U.S. Geological Survey indicate that the quality of water from eight of the production wells has changed since the well field began operation. For example, from 1972 to 1991, hardness of water from one well has increased from 90 to 292 milligrams per liter (224 percent). The confining unit, which separates the fluvial deposits aquifer from the Memphis aquifer in the area of the well field, is relatively thick and contains many clay layers. However, a test hole drilled for one of five shallow wells installed in the alluvial aquifer in the Mississippi Alluvial Plain just west of the well field indicated that the confining unit separating the alluvial aquifer from the Memphis aquifer locally is absent. Differences in hydrauLic head between the alluvial and fluvial deposits aquifers and the Memphis aquifer favor downward leakage of ground water. Thus, the absence of the confining unit beneath the Mississippi Alluvial Plain just west of the well field provides a direct pathway for water in the alluvial aquifer to enter the Memphis aquifer. Comparison of selected water-quality properties and major inorganic and trace element constituent concentrations in samples from the alluvial, fluvial deposits, and Memphis aquifers indicates that the source of ground water causing waterquality changes at the Davis well field is the alluvial aquifer west of the well field . The presence of tritium and chlorofluorocarbons in water from wells screened in the Memphis aquifer in the western part of the well field indicates that relatively young (post-1940) water from the alluvial aquifer has entered the Memphis aquifer. NETPATH geochemical model code was used to mix waters from the alluvial aquifer with water from the Memphis aquifer using chloride as a conservative tracer. The resulting models indicated that a mixture containing 3 percent alluvial aquifer water mixed with 97 percent unaffected Memphis aquifer water would produce the chloride concentration measured in water from the Memphis aquifer well most affected by water-quality changes. NETPATH also was used to calculate mixing percentages of alluvial and Memphis aquifer Abstract waters based on changes in the concentrations of selected dissolved major inorganic and trace element constituents that define the dominant reactions that occur during mixing. These models indicated that a mixture containing 18 percent alluvial aquifer water and 82 percent unaffected Memphis aquifer water would produce the major constituent and trace element concentrations measured in water from the Memphis aquifer well most affected by water-quality changes. However, these model simulations predicted higher dissolved methane concentrations than were measured in water samples from the Memphis aquifer wells.

Tennessee↗

Simulation of Regional Ground-Water Flow in the Suwannee River Basin, Northern Florida and Southern Georgia

The Suwannee River Basin covers a total of nearly 9,950 square miles in north-central Florida and southern Georgia. In Florida, the Suwannee River Basin accounts for 4,250 square miles of north-central Florida. Evaluating the impacts of increased development in the Suwannee River Basin requires a quantitative understanding of the boundary conditions, hydrogeologic framework and hydraulic properties of the Floridan aquifer system, and the dynamics of water exchanges between the Suwannee River and its tributaries and the Floridan aquifer system. Major rivers within the Suwannee River Basin are the Suwannee, Santa Fe, Alapaha, and Withlacoochee. Four rivers west of the Suwannee River are the Aucilla, the Econfina, the Fenholloway, and the Steinhatchee; all drain to the Gulf of Mexico. Perhaps the most notable aspect of the surface-water hydrology of the study area is that large areas east of the Suwannee River are devoid of channelized, surface drainage; consequently, most of the drainage occurs through the subsurface. The ground-water flow system underlying the study area plays a critical role in the overall hydrology of this region of Florida because of the dominance of subsurface drain-age, and because ground-water flow sustains the flow of the rivers and springs. Three principal hydrogeologic units are present in the study area: the surficial aquifer system, the intermediate aquifer system, and the Floridan aquifer system. The surficial aquifer system principally consists of unconsoli-dated to poorly indurated siliciclastic deposits. The intermediate aquifer system, which contains the intermediate confining unit, lies below the surficial aquifer system (where present), and generally consists of fine-grained, uncon-solidated deposits of quartz sand, silt, and clay with interbedded limestone of Miocene age. Regionally, the intermediate aquifer system and intermediate con-fining unit act as a confining unit that restricts the exchange of water between the over-lying surficial and underlying Upper Floridan aquifers. The Upper Floridan aquifer is present throughout the study area and is extremely permeable and typically capable of transmitting large volumes of water. This high permeability largely is due to the widening of fractures and formation of conduits within the aquifer through dissolu-tion of the limestone by infiltrating water. This process has also produced numerous karst features such as springs, sinking streams, and sinkholes. A model of the Upper Floridan aquifer was created to better understand the ground-water system and to provide resource managers a tool to evaluate ground-water and surface-water interactions in the Suwannee River Basin. The model was developed to simulate a single Upper Floridan aquifer layer. Recharge datasets were developed to represent a net flux of water to the top of the aquifer or the water table during a period when the system was assumed to be under steady-state conditions (September 1990). A potentiometric-surface map representing water levels during September 1990 was prepared for the Suwannee River Water Management District (SRWMD), and the heads from those wells were used for calibration of the model. Additionally, flows at gaging sites for the Suwannee, Alapaha, Withlacoochee, Santa Fe, Fenholloway, Aucilla, Ecofina, and Steinhatchee Rivers were used during the calibration process to compare to model computed flows. Flows at seven first-magnitude springs selected by the SRWMD also were used to calibrate the model. Calibration criterion for matching potentiometric heads was to attain an absolute residual mean error of 5 percent or less of the head gradient of the system which would be about 5 feet. An absolute residual mean error of 4.79 feet was attained for final calibration. Calibration criterion for matching streamflow was based on the quality of measurements made in the field. All measurements used were rated ?good,? so the desire was for simulated values to be wi

Florida, Georgia↗

Potential for ground-water contamination from movement of wastewater through the unsaturated zone, upper Mojave River Basin, California

Septic-tank wastewater disposed in 30-foot-deep seepage pits (dry wells) at 46,000 residences is estimated to equal 18 percent of the natural recharge to the sole-source aquifer in the rapidly developing upper Mojave River Basin (Victor Valley) in the high desert northeast of Los Angeles. Vertical rates of movement of the wastewater wetting front through the unsaturated zone at three newly occupied residences ranged from 0.07 to 1.0 foot per day. These rates translate to traveltimes of several months to several years for the wastewater wetting front to reach the water table and imply that wastewater from many disposal systems already has reached the water table, which averages about 150 feet below land surface in the Victor Valley. As wastewater percolates from seepage pits into the adjacent unsaturated zone, the nitrogen present in reduced form is rapidly converted to nitrate. Analyses on soil-core extracts and soil moisturefrom suction lysimeters installed beneath the seepage pits at eight residences showed that nitrate concentrations and nitrate/ chloride ratios generally become lower with increasing depth. The intervals of greatest decline seemed to coincide with finer soil texture or were near the water table. Nitrate-reducing bacteria were tested for and found to be present in soil cores from two residences. Sparse nitrogen-15 data from suction lysimeters at one of these residences, where thenitrate concentration decreased by about one-half at a depth of 200 feet, indicate that the nitrate decline was accompanied by nitrogen-15 enrichment in the residual nitrate with an isotope-separation factor of about -10 permil. Despite the potential input of abundant nitrogen with the domestic wastewater recharge, nitrate concentrations in the area's ground water are generally low. The absence of high nitrate concentrations in the ground water is consistent with the existence of denitrification, a microbial nitrogen-removal mechanism, as wastewater moves through the thick unsaturated zone and mixes with the ground water. The observed low nitrate concentrations also could be explained by a dilution by vertical mixing in the saturated zone and retention of the wastewater in the unsaturated zone. Results of a single-cell mixing model that allows nitrate from wastewater to be mixedinstantaneously with the underlying ground water suggest that measurable increases in nitrate concentration should be expected within 5 to 10 years after wastewater reaches the water table if the mixing depth is less than 100 feet. Although high fecal-coliform densities were measured in wastewater from septic tanks and seepage pits, removal of these enteric bacteria in the unsaturated zone is very effective, as was indicated by their absence in soil only a few feet from the seepage pits. In testing for organic priority pollutants in wastewater, 17 of 85 compounds were detected. Most compounds detected were present in low concentrations, except at one residence where the concentration of three compounds exceeded 100 micrograms per liter. These high concentrations may be a consequence of disposal practices unique to this residence. Extractable organic priority pollutants were not found in any soil cores taken adjacent to seepage pits and, therefore, are not of concern.

Water-Resources Investigations Report↗

Simulation of ground-water flow in an unconfined sand and gravel aquifer at Marathon, Cortland County, New York

The Village of Marathon, in Cortland County, N.Y., has three municipal wells that tap a relatively thin (25 to 40 feet thick) and narrow (less than 0.25 mile wide) unconfined sand and gravel aquifer in the Tioughnioga River valley. Only one of the wells is in use because water from one well has been contaminated by petroleum chemicals from a leaking storage tank, and water from the other well contains high concentrations of manganese. The operating well pumps about 0.1 million gallons per day and supplies about 1,000 people. A three-dimensional, finite-difference ground-water-flow model was used to (1) compute hydraulic heads in the aquifer under steady-state conditions, (2) develop a water budget, and (3) delineate the areas contributing recharge to two simulated wells that represent two of the municipal wells: one 57 feet east of the Tioughnioga River, the other 4,000 feet to the south and 75 feet from a man-made pond. The water budget for simulated long-term average, steady-state conditions with two simulated pumping wells indicates that the principal sources of recharge to the unconfined aquifer are unchanneled runoff and ground-water inflow from the uplands (41 percent of total recharge), precipitation that falls directly on the aquifer (34 percent), and stream leakage (23 percent). Only 2 percent of the recharge to the aquifer is from ground-water underflow into the northern end of the modeled area. Most of the simulated groundwater discharge from the modeled area (78 percent of total discharge) is to the Tioughnioga River; the rest discharges to the two simulated wells (19 percent) and as underflow at the southern end of the modeled area (3 percent). Results of a particle-tracking analysis indicate that the aquifer contributing area of the northern (simulated) well is 0.10 mile wide and 0.15 mile long and encompasses 0.015 square miles; the contributing area of the southern (simulated) well is 0.20 mile wide and 0.11 mile long and encompasses 0.022 square miles. The average traveltime of ground water from the valley wall to either simulated well is about 1.5 years, calculated on the basis of an assumed aquifer porosity of 0.3. The flowpath analysis indicates that both contributing areas contain surface-water sources of recharge; the Tioughnioga River and Hunts Creek contribute water to the northern well, and a pond and a small tributary contribute water to the southern well. Ground-water temperature in an observation well between the Tioughnioga River and the municipal well fluctuated several degrees Fahrenheit in response to pumping of the municipal well. This temperature fluctuation, in conjunction with the pumping well causing a ground-water gradient from the Tioughnioga River to the pumping well (ground-water levels in the pumping well were generally greater than 3 ft lower than that of the Tioughnioga River), indicate that there is a hydraulic connection between the river and aquifer at this site.

Water-Resources Investigations Report↗