Search USGSSearch

SEARCH · Search USGS

Results for “Pennsylvania Birds”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

48 records · Page 3Linked to original sources

Ecotoxicological damage from zinc smelting at Palmerton, Pennsylvania

The two zinc smelters at Palmerton, PA emitted huge amounts of contaminants ( 260,000 t of Zn, 3,300 t of Cd, 6,800 t of Pb) to the air and severely damaged the forest on Blue Mountain. The high Zn concentrations in soil killed tree seedlings by inhibiting root elongation. The result was a forest with too few young trees. When natural stresses such as fire challenged the forest, the forest failed to regenerate, and the exposed soil eroded down the steep slopes. Tree species that could sprout were favored over those that developed from seeds. As a result of high zinc concentrations, the lichen and moss communities were depauperate for at least 20 km along Blue Mountain. The denuded areas are in the process of being reclaimed with the addition of a mixture of fly ash and sewage sludge, which is seeded with grasses tolerant to the harsh conditions. In preliminary experiments, the fly ash and sewage sludge mixture was stable, despite the steepness of the slopes of the reclaimed sites on Blue Mountain. Zinc emissions reduced the decomposition rate of plant material on Blue Mountain. The partially decomposed litter, in particular, accumulated on the surface of the mineral soil. The populations of both microorganisms and arthropods were greatly reduced in soils near the smelters. Samples of litter collected from sites spanning 30 km were toxic to woodlice, and Zn was shown to be the toxic factor. A white-tailed deer examined had a very high renal Zn concentration and an articular lesion in one of its hind legs that closely resembled the lesions reported in Zn-poisoned horses. Zinc concentrations were regulated in wildlife tissues and were not reliable indicators of exposure, except in extreme cases. Two songbirds, a shrew, and several rabbits contained Pb concentrations that were suggested to be toxic. Shrews and ground-feeding songbirds accumulated relatively high concentrations of Pb. Exposure to Pb seemed to be related to the amount of soil that an animal ingests. Some white-tailed deer and cottontails had renal Cd concentrations near 600 ppm w.w., which is associated with renal damage in other mammals. The accumulation of Cd was greatest in wildlife that lived longest. The destruction of the habitat for wildlife on Blue Mountain decreased wildlife populations. Populations of insectivorous birds, however, were depressed well beyond the area of obvious damage to the forest. Forest-floor salamanders were completely absent from study sites spanning 18 km along Blue Mountain. Actual reductions in wildlife populations were much greater than would have been predicted from habitat suitability models alone.

Book chapter

Identification of water-bearing fractures by the use of geophysical logs, May to July 1998, former Naval Air Warfare Center, Bucks County, Pennsylvania

Between May and July 1998, 10 monitor wells were drilled near the site of the former Naval Air Warfare Center (NAWC), Warminster, Bucks County, Pa., to monitor water levels and sample ground water in shallow and intermediate water-bearing fractures. The sampling will determine the horizontal and vertical distribution of contaminated ground water migrating from known or suspected sources. Three boreholes were drilled on the property at 960 Jacksonville Road, at the northwestern side of NAWC, along strike from Area A; seven boreholes were drilled in Area B in the southeastern corner of NAWC. Depths range from 40.5 to 150 feet below land surface. Borehole geophysical logging and video surveys were used to identify water-bearing fractures so that appropriate intervals could be screened in each monitor well. Geophysical logs were obtained at the 10 monitor wells. Video surveys were obtained at three monitor wells in the southeastern corner of the NAWC property. Caliper logs and video surveys were used to locate fractures. Inflections on fluid-temperature and fluid-resistivity logs were used to locate possible water-bearing fractures. Heatpulse-flowmeter measurements verified these locations. Natural-gamma logs provided information on stratigraphy. After interpretation of geophysical logs, video surveys, and driller's logs, all wells were screened such that water-level fluctuations could be monitored and water samples collected from discrete water-bearing fractures in each monitor well.

Open-File Report

Modeling to Predict Escherichia coli at Presque Isle Beach 2, City of Erie, Erie County, Pennsylvania

The Lake Erie beaches in Pennsylvania are a valuable recreational resource for Erie County. Concentrations of Escherichia coli (E. coli) at monitored beaches in Presque Isle State Park in Erie, Pa., occasionally exceed the single-sample bathing-water standard of 235 colonies per 100 milliliters resulting in potentially unsafe swimming conditions and prompting beach managers to post public advisories or to close beaches to recreation. To supplement the current method for assessing recreational water quality (E. coli concentrations from the previous day), a predictive regression model for E. coli concentrations at Presque Isle Beach 2 was developed from data collected during the 2004 and 2005 recreational seasons. Model output included predicted E. coli concentrations and exceedance probabilities--the probability that E. coli concentrations would exceed the standard. For this study, E. coli concentrations and other water-quality and environmental data were collected during the 2006 recreational season at Presque Isle Beach 2. The data from 2006, an independent year, were used to test (validate) the 2004-2005 predictive regression model and compare the model performance to the current method. Using 2006 data, the 2004-2005 model yielded more correct responses and better predicted exceedances of the standard than the use of E. coli concentrations from the previous day. The differences were not pronounced, however, and more data are needed. For example, the model correctly predicted exceedances of the standard 11 percent of the time (1 out of 9 exceedances that occurred in 2006) whereas using the E. coli concentrations from the previous day did not result in any correctly predicted exceedances. After validation, new models were developed by adding the 2006 data to the 2004-2005 dataset and by analyzing the data in 2- and 3-year combinations. Results showed that excluding the 2004 data (using 2005 and 2006 data only) yielded the best model. Explanatory variables in the 2005-2006 model were log10 turbidity, bird count, and wave height. The 2005-2006 model correctly predicted when the standard would not be exceeded (specificity) with a response of 95.2 percent (178 out of 187 nonexceedances) and correctly predicted when the standard would be exceeded (sensitivity) with a response of 64.3 percent (9 out of 14 exceedances). In all cases, the results from predictive modeling produced higher percentages of correct predictions than using E. coli concentrations from the previous day. Additional data collected each year can be used to test and possibly improve the model. The results of this study will aid beach managers in more rapidly determining when waters are not safe for recreational use and, subsequently, when to close a beach or post an advisory.

Scientific Investigations Report

Evaluation of borehole geophysical logging, aquifer-isolation tests, distribution of contaminants, and water-level measurements at the North Penn Area 5 Superfund Site, Bucks and Montgomery Counties, Pennsylvania

Borehole geophysical logging and aquifer-isolation (packer) tests were conducted at the North Penn Area 5 Superfund site in Bucks and Montgomery Counties, Pa. Caliper, naturalgamma, single-point-resistance, fluid-temperature, fluid-resistivity, heatpulse-flowmeter, and digital acoustic-televiewer logs and borehole television surveys were collected in 32 new and previously drilled wells that ranged in depth from 68 to 302 feet. Vertical borehole-fluid movement direction and rate were measured with a high-resolution heatpulse flowmeter under nonpumping conditions. The suite of logs was used to locate water-bearing fractures, determine zones of vertical borehole-fluid movement, select depths to set packers, and locate appropriate screen intervals for reconstructing new wells as monitoring wells. Aquifer-isolation tests were conducted in four wells to sample discrete intervals and to determine specific capacities of discrete water-bearing zones. Specific capacities of isolated zones during packer testing ranged from 0.12 to 15.30 gallons per minute per foot. Most fractures identified by borehole geophysical methods as water-producing or water-receiving zones produced water when isolated and pumped. The acoustic-televiewer logs define two basic fracture sets, bedding-plane partings with a mean strike of N. 62° E. and a mean dip of 27° NW., and high-angle fractures with a mean strike of N. 58° E. and a mean dip of 72° SE. Correlation of heatpulse-flowmeter data and acoustic-televiewer logs showed 83 percent of identified water-bearing fractures were high-angle fractures.

Pennsylvania

Hydrologic investigations and a preliminary conceptual model of the groundwater system at North Penn Area 1 Superfund Site, Souderton, Montgomery County, Pennsylvania

The U.S. Geological Survey (USGS) conducted hydrogeologic investigations, reviewed existing data, and developed a preliminary conceptual model of the groundwater system as part of technical support of the U.S. Environmental Protection Agency (EPA) at the North Penn Area 1 Superfund Site (hereafter, the NP1 Site) located within the Borough of Souderton in Montgomery County, Pennsylvania. Field work and monitoring took place during 2012–18. The area is underlain by sedimentary formations that form a fractured-rock aquifer used for drinking water and industrial supply. The EPA placed the Site on the National Priorities List in 1989, identifying tetrachloroethylene (PCE) and trichloroethylene (TCE) as contaminants of concern. During 2012–18, the USGS conducted field activities that included drilling an 82-foot (ft)-deep monitoring well (MG 2220) in 2016, reconstructing a 208-ft-deep former industrial production well (MG 668 [Granite Knitting Mill]), and collecting borehole geophysical and video logs and water levels from those and five additional wells, which ranged in depth from about 50 to 200 ft below land surface. Continuous water levels were collected during 2014–17, and a synoptic set of water levels were measured in April 2018 in the seven wells. The borehole geophysical logs (caliper, acoustic televiewer, natural gamma, single-point resistance, vertical flow, and fluid temperature and resistivity) and borehole video logs in the seven wells were evaluated to assess potential for lithologic correlation and to identify and describe water-bearing features, which included both low- and high-angle fractures and other openings oriented along dipping bedding planes, joints, or possible faults. Borehole geophysical logs collected by USGS in 1992 in a 300-ft-deep former production well near the Site were also evaluated. Few to no distinctive features were identified on geophysical logs (natural gamma and single-point resistance) that could be used for correlation, thus limiting this approach to determining local geologic structure. Extensive fracturing in the upper 62 ft of monitoring well MG 2220 indicates that the well was likely drilled through a zone of faulting, and other evidence of faulting is present in the area near the Site. Assessment of continuous water levels showed hydraulic connections among some wells as indicated by rising or falling water levels in response to changes in pumping rates at nearby wells. A map of water levels measured in April 2018 indicates potential for groundwater flow generally toward the stream to the south and southwest of the Site, but the limited water-level data are insufficient to describe vertical groundwater gradients or lateral gradients in any detail. Review of 1999–2022 volatile organic compound (VOC) monitoring data collected by the Pennsylvania Department of Environmental Protection for five monitoring wells indicates that the highest groundwater concentrations of PCE and TCE were found in samples from extraction well MG 2201 (S-1) downgradient from, and nearest to, the previously identified Site contaminant source area, and these concentrations fluctuated through time. PCE concentrations were higher than TCE concentrations in samples from all five monitoring wells and were much higher than TCE concentrations in samples from extraction well MG 2201 (S-1). Temporally variable recharge is a possible factor affecting observed fluctuations in PCE concentrations in groundwater samples from well extraction MG 2201 (S-1), as indicated by a general inverse relation between PCE concentrations and water levels in a nearby long-term observation well. The PCE concentration of 1,830 micrograms per liter (μg/L) in a May 2018 water sample from monitoring well MG 2220 was more than four times the PCE concentration of 444 μg/L in a December 2017 sample from the nearby extraction well MG 2201 (S-1), which is open to fewer fractures. Low concentrations of VOCs were measured in surface water at two stream sites downgradient from wells with the highest groundwater VOC concentrations at the Site, indicating that discharge of contaminated groundwater to the stream is likely. Development of a conceptual model of the groundwater system was constrained by limited data. In areas with no pumping, groundwater-flow directions generally are thought to be controlled by topography and geologic structure (bedding orientation) and likely to the south and southwest of the Site, with local flow directions affected by orientations of fractures, joints, and local faults. Additional investigations that could help improve the conceptual model of the groundwater system and help delineate the extent of groundwater contamination and its transport are discussed.

Pennsylvania

Geophysical and video logs of selected wells at and near the former Naval Air Warfare Center Warminster, Bucks County, Pennsylvania, 2017-19

The U.S. Geological Survey (USGS) collected borehole geophysical and video logs in 17 open-hole wells in Northampton, Warminster, and Warwick Townships, Bucks County, Pennsylvania during 2017–19 to support detailed groundwater investigations at and near the former Naval Air Warfare Center (NAWC) Warminster, where groundwater contamination with per- and polyfluoroalkyl substances (PFAS) had become a concern since 2014. The area is underlain by the Triassic Stockton Formation, which forms a fractured-sedimentary-rock aquifer used for private, industrial, and public drinking-water supply. The geophysical and video logs were used to characterize the boreholes and identify potential water-bearing fractures for subsequent detailed investigations. Of the 17 wells that were logged, subsequent investigations were conducted by USGS in 15 wells and included hydraulic tests of discrete water-bearing zones using a straddle-packer system in 13 wells and depth-discrete point sampling in 2 wells. These 15 wells ranged in depth from about 210 to 604 feet (ft) below land surface (bls) and included six new 6-inch diameter wells drilled to initial depths of 600 ft bls on the former NAWC Warminster base property in 2018 and nine 8- to 12-inch diameter existing former production or unused test wells. Partial geophysical or video logs also were collected by USGS during 2018 in two other wells that were not included in subsequent detailed investigations. Most wells had numerous water-bearing fractures or openings throughout the depth of the open boreholes. Most of these water-bearing features appeared to be openings parallel to bedding or high-angle fractures approximately orthogonal to bedding. Casing lengths ranged from about 19 to 93 ft bls. Depth to the ambient water level at the time of logging ranged from about 1.8 ft above land surface in a flowing well to about 55 ft bls. Measured borehole flow was predominantly downward in most of the deepest wells (greater than 400 ft), which were commonly located at the highest land-surface elevations, and contained inflow from fractures at relatively shallow depths and outflow through fractures near or below depths of 500 ft bls. Borehole flow was predominantly upward in most wells less than 400 ft in depth.

Pennsylvania

Drilling and geophysical logs of the tophole at an oil-and-gas well site, Central Venango County, Pennsylvania

In a study conducted by the U.S. Geological Survey, in cooperation with the Pennsylvania Department of Conservation and Natural Resources, Bureau of Topographic and Geologic Survey, drilling and geophysical logs were used to characterize the geohydrologic framework and the freshwater and saline-water zones penetrated by the tophole at an oil-and-gas well site in central Venango County, Pennsylvania. The geohydrologic setting of the well site is typical of the dissected Appalachian Plateau underlain by Pennsylvanian and Mississippian sandstone and shale. The drilling, gamma, and acoustic-televiewer logs collected from the 575-foot deep tophole define the penetrated Pennsylvanian and Mississippian stratigraphic units and their lithology. The caliper, video, and acoustic-televiewer logs delineate multiple bedding-related and high-angle fractures in the lower Pottsville Group and Shenango Formation from 22 to 249 feet below land surface. The caliper and acoustic-televiewer logs indicate a sparsity of fractures below 249 feet below land surface in the lowermost Shenango Formation, Cuyahoga Group, Corry Sandstone, “Drake Well” formation, and upper Riceville Formation. About half of the blown yield during drilling of the tophole was from fractures in the upper Shenango Formation between 80 and 167 feet below land surface and the other half from fractures in the lower Shenango between 190 and 249 feet below land surface. Following drilling, fractures above the water level at about 145 feet below land surface produced freshwater with a specific conductance of less than 150 microsiemens per centimeter at 25 degrees Celsius that cascaded down the hole. As indicated by the fluid resistivity and temperature logs, most of the downflow exited the hole at the water-bearing fractures at 249 feet below land surface. The downward flow in the tophole reflects the downward hydraulic gradient between the water-bearing fractures above the water level and those at 249 feet below land surface. Low conductivity and high resistivity values on the dual induction logs indicate freshwater above 285 feet below land surface in the Shenango sandstones, which is consistent with a specific conductance of blown yield of 400 microsiemens per centimeter at 25 degrees Celsius at 200 feet below land surface. High conductivity and low resistivity values on the induction logs indicate the presence of saline water below 450 feet in the Corry Sandstone. The highest specific conductance of the blown yield, 1,200 microsiemens per centimeter at 25 degrees Celsius, was measured at 480 feet below land surface following penetration of the Corry Sandstone. Collection and integrated analysis of drilling and geophysical logs provided an efficient and effective means for characterizing the geohydrologic framework and conditions penetrated by the tophole at the selected oil-and-gas well site. The logging methods and lessons learned at this well site could be applied at other oil-and-gas drilling sites to better characterize the shallow subsurface with the overall goal of protecting freshwater aquifers during hydrocarbon development.

Pennsylvania

Geophysical Logs, Aquifer Tests, and Water Levels in Wells in and Near the North Penn Area 7 Superfund Site, Upper Gwynedd Township, Montgomery County, Pennsylvania, 2002-2006

Ground water in the vicinity of several industrial facilities in Upper Gwynedd Township and Lansdale Borough, Montgomery County, Pa., is contaminated with several volatile organic compounds (VOCs). The 2-square-mile area was placed on the National Priorities List as the North Penn Area 7 Superfund Site by the U.S. Environmental Protection Agency (USEPA) in 1989. The U.S. Geological Survey (USGS) conducted geophysical logging, aquifer testing, water-level monitoring, and streamflow measurements in the vicinity of North Penn Area 7 from October 2002 through December 2006. This followed work that began in 2000 to assist the USEPA in developing an understanding of the hydrogeologic framework in the area as part of the USEPA Remedial Investigation. The study area is underlain by Triassic- and Jurassic-age sandstones, siltstones, and shales of the Lockatong Formation and the Brunswick Group. Regionally, these rocks strike northeast and dip to the northwest. The sequence of rocks form fractured-rock aquifers that act as a set of confined to semi-confined layered aquifers of differing permeabilities. The aquifers are recharged by precipitation and discharge to streams and wells. The Wissahickon Creek headwaters are less than 1 mile northeast of the study area. This stream flows southwest approximately parallel to strike and bisects North Penn Area 7. Ground water is pumped in the vicinity of North Penn Area 7 for industrial use and public supply. The USGS collected geophysical logs for 42 wells that ranged in depth from 40 to 477 ft. Aquifer-interval-isolation testing was done in 17 of the 42 wells, for a total of 122 zones tested. A multiple-well aquifer test was conducted by monitoring the response of 14 wells to pumping and shutdown of a 600-ft deep production well in November-December 2004. In addition, water levels were monitored continuously in four wells in the area from October 2002 through September 2006, and streamflow was measured quarterly at two sites on Wissahickon Creek from December 2002 through September 2005. Geophysical logging identified water-bearing zones associated with high-angle fractures and bedding-plane openings throughout the depth of the boreholes. Heatpulse-flowmeter measurements under non-pumping, ambient conditions in 16 wells greater than 200 ft in depth indicated that borehole flow, where detected, was only upward in 2 wells and only downward in 5 wells. In nine wells, both upward and downward flow were measured. Geologic structure and pumping in the area affect the spatial distribution of vertical gradients. Heatpulse-flowmeter measurements under pumping conditions were used to identify the most productive intervals in wells. Correlation of natural-gamma-ray logs indicated bedding in the area probably strikes about 45 to 65 degrees northeast and dips about 9 degrees northwest. Aquifer intervals isolated by inflatable packers in 17 wells were pumped to test productivity of water-bearing zones and to collect samples to determine chemical quality of water produced from the interval. Interval-isolation testing confirmed the vertical hydraulic gradients indicated by heatpulse-flowmeter measurements. The specific capacities of the 122 isolated intervals ranged over about three orders of magnitude, from 0.01 to 10.6 gallons per minute per foot, corresponding to calculated transmissivities of 1.2 to 2,290 feet squared per day. Intervals adjacent to isolated pumped intervals commonly showed little response to pumping of the isolated zone. The presence of vertical hydraulic gradients and lack of adjacent-interval response to pumping in isolated intervals indicate a limited degree of vertical hydraulic connection between the aquifer sections tested. Differences were apparent in inorganic water quality of water from isolated intervals, including pH, specific conductance, and dissolved oxygen. Concentrations of most VOC contaminants in most wells with predominantly upward vertical gradients were g

Scientific Investigations Report

Interpretation of geophysical logs, aquifer tests, and water levels in wells in and near the North Penn Area 7 Superfund site, Upper Gwynedd Township, Montgomery County, Pennsylvania, 2000-02

Ground water in the vicinity of various industrial facilities in Upper Gwynedd Township and Lansdale Borough, Montgomery County, Pa., is contaminated with various volatile organic compounds (VOCs). The 2-square-mile area was placed on the National Priorities List as the North Penn Area 7 Superfund site by the U.S. Environmental Protection Agency (USEPA) in 1989. The U.S. Geological Survey (USGS) conducted geophysical logging, aquifer testing, water-level monitoring, and streamflow measurements in the vicinity of North Penn Area 7 beginning autumn 2000 to assist the USEPA in developing an understanding of the hydrogeologic framework in the area as part of the USEPA Remedial Investigation. The study area is underlain by Triassic and Jurassic-age sandstones, siltstones, and shales of the Lockatong Formation and the Brunswick Group. Regionally, these rocks strike northeast and dip to the northwest. The sequence of rocks form a fractured-sedimentary-rock aquifer that acts as a set of confined to partially confined layered aquifers of differing permeabilities. The aquifers are recharged by precipitation and discharge to streams and wells. The Wissahickon Creek headwaters are less than 1 mile northeast of the study area, and this stream flows southwest to bisect North Penn Area 7. Ground water is pumped in the vicinity of North Penn Area 7 for industrial use and public supply. The USGS collected geophysical logs for 16 wells that ranged in depth from 50 to 623 feet. Aquifer-interval-isolation testing was done in 9 of the 16 wells, for a total of 30 zones tested. A multiple-well aquifer test was conducted by monitoring the response of 14 wells to pumping a 600-ft deep production well in February and March 2002. In addition, water levels were monitored continuously in three wells in the area and streamflow was measured quarterly at two sites on Wissahickon Creek from December 2000 through September 2002. Geophysical logging identified water-bearing zones associated with high-angle fractures and bedding-plane openings throughout the depth of the boreholes. Heatpulse-flowmeter measurements under nonpumping, ambient conditions indicated that borehole flow, where detected, was in the upward direction in three of the eight wells and in the downward direction in three wells. In two wells, both upward and downward flow were measured. Heatpulse-flowmeter measurements under pumping conditions were used to identify the most productive intervals in wells. Correlation of natural-gamma-ray and single-point-resistance logs indicated that bedding in the area probably strikes about 40 degrees northeast and dips from 6 to 7 degrees northwest. Aquifer intervals isolated by inflatable packers in wells were pumped to test productivity and to collect samples to determine chemical quality of water produced from the interval. Interval-isolation testing confirmed the presence of vertical hydraulic gradients indicated by heatpulse-flowmeter measurements. The specific capacities of isolated intervals ranged over two orders of magnitude, from 0.02 to more than 3.6 gallons per minute per foot. Intervals adjacent to isolated pumped intervals showed little response to pumping the isolated zone. The presence of vertical hydraulic gradients and lack of adjacent-interval response to pumping in isolated intervals indicate a limited degree of vertical hydraulic connection between the aquifer intervals tested. Concentrations of most VOC contaminants generally were highest in well-water samples from the shallowest isolated intervals, with some exceptions. Trichloroethylene, cis-1,2-dichloroethylene, and toluene were the most frequently detected VOCs, with maximum concentrations of greater than 340, 680, and greater than 590 micrograms per liter, respectively. Results of the aquifer test with multiple observation wells showed that water levels in 4 of the 14 wells declined in response to pumping. The four wells that responded to pumping are either along str

Scientific Investigations Report

Aquifer tests and simulation of ground-water flow in Triassic sedimentary rocks near Colmar, Bucks and Montgomery Counties, Pennsylvania

This report presents the results of a study by the U.S. Geological Survey in cooperation with the U.S. Environmental Protection Agency to evaluate ground-water flow in Triassic sedimentary rocks near Colmar, in Bucks and Montgomery Counties, Pa. The study was conducted to help the U.S. Environmental Protection Agency evaluate remediation alternatives at the North Penn Area 5 Superfund Site near Colmar, where ground water has been contaminated by volatile organic solvents (primarily trichloroethene). The investigation focused on determining the (1) drawdown caused by separately pumping North PennWater Authority wells NP–21 and NP–87, (2) probable paths of groundwater movement under present-day (2000) conditions (with NP–21 discontinued), and (3) areas contributing recharge to wells if pumping from wells NP-21 or NP–87 were restarted and new recovery wells were installed. Drawdown was calculated from water levels measured in observation wells during aquifer tests of NP–21 and NP–87. The direction of ground-water flow was estimated by use of a three-dimensional ground-water-flow model. Aquifer tests were conducted by pumping NP–21 for about 7 days at 257 gallons per minute in June 2000 and NP–87 for 3 days at 402 gallons per minute in May 2002. Drawdown was measured in 45 observation wells during the NP–21 test and 35 observation wells during the NP–87 test. Drawdown in observation wells ranged from 0 to 6.8 feet at the end of the NP–21 test and 0.5 to 12 feet at the end of the NP–87 test. The aquifer tests showed that ground-water levels declined mostly in observation wells that were completed in the geologic units penetrated by the pumped wells. Because the geologic units dip about 27 degrees to the northwest, shallow wells up dip to the southeast of the pumped well showed a good hydraulic connection to the geologic units stressed by pumping. Most observation wells down dip from the pumping well penetrated units higher in the stratigraphic section that were not well connected to the units stressed by pumping. The best hydraulic connection to the pumped wells was indicated by large drawdown in observation wells that penetrate the water-bearing unit encountered below 400 feet below land surface in wells NP–21 and NP–87. The hydraulic connection between wells NP–21 (or NP–87) and observation wells in the southern area of ground-water contamination near the BAE Systems facility is good because the observation wells probably penetrate this water-bearing unit. A 3-dimensional, finite-difference, groundwater- flow model was used to simulate flow paths and areas contributing recharge to wells for current (2000) conditions of pumping in the Colmar area and for hypothetical situations of pumping suggested by the U.S. Environmental Protection Agency that might be used for remediation. Simulations indicate that under current conditions, ground water in the northern area of contamination near the former Stabilus facility moves to the northwest and discharges mostly to West Branch Neshaminy Creek; in the southern area of contamination near BAE Systems facility, ground water probably moves west and discharges to a tributary of West Branch Neshaminy Creek near well NP–21. Model simulations indicate that if NP–21 or NP–87 are pumped at 400 gallons per minute, groundwater recharge is likely captured from the southern area of contamination, but ground-water recharge from the northern area of contamination is less likely to be captured by the pumping. Simulations also indicate that pumping of a new recovery well near BAE Systems facility at 8 gallons per minute and two new recovery wells near the former Stabilus facility at a total of about 30 gallons per minute probably would capture most of the ground-water recharge in the areas where contamination is greatest.

Water-Resources Investigations Report

Hydrogeologic framework, water levels, and selected contaminant concentrations at Valmont TCE Superfund Site, Luzerne County, Pennsylvania, 2020

The Valmont TCE Superfund Site, Luzerne County, Pennsylvania is underlain by fractured and folded sandstones and shales of the Pottsville and Mauch Chunk Formations, which form a fractured-rock aquifer recharged locally by precipitation. Industrial activities at the former Chromatex Plant resulted in trichloroethene (TCE) contamination of groundwater at and near the facility, which was identified in 1987 and led to listing as a Superfund site by the U.S. Environmental Protection Agency (EPA) in 1989. To address the problem of TCE concentrations in nearby residential wells that exceed the maximum contaminant level (MCL) of 5 micrograms per liter (μg/L), alternate water supplies were provided. A 2015 review of initial characterization and subsequent remediation by the EPA identified the need for an updated understanding of the complex hydrogeology and the conceptual site model. Additional contaminants present in groundwater at the site include some other volatile organic compounds (VOCs) and per- and polyfluoroalkyl substances (PFAS), predominantly consisting of perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) present in concentrations that exceeded the EPA Health Advisory (HA) level of 5 nanograms per liter (ng/L) for combined PFOA and PFOS. In response to a request from the EPA in 2019, the U.S. Geological Survey (USGS) prepared cross sections and maps to provide more information about the hydrogeologic framework at and near the site and assist in improving the conceptual site model using water level and contaminant data collected by the EPA in 2020. The cross sections present lithologic correlations from available geophysical logs collected in wells from 2002 to 2014; they show alternating intervals of relatively elevated and reduced natural gamma activity that correspond to changes in lithology, with water-bearing zones and well screens commonly located at lithologic contacts, sometimes near thin coal seams. Water-bearing zones commonly are associated with fractures at or near lithologic contacts but also may be associated with fractures at or near apparent faulting. Recent (March 2020) water-level data shown on cross sections and maps indicate large downward vertical gradients and apparent radial gradients laterally to the northeast, northwest, and southwest that generally following topography. Recent (February to March 2020) data for TCE groundwater concentration shown on cross sections and maps indicate the highest TCE concentrations (greater than 3,000 μg/L and as much as 75,000 μg/L) and combined PFOA and PFOS concentrations (greater than 1,000 ng/L and up to at least 2,350 ng/L) are from shallow (less than 60 feet [ft] below land surface [bls]) and intermediate depth (60 to 100 ft bls) wells near the center of the former Chromatex Plant. TCE and PFAS (as combined PFOA and PFOS) contamination is present at greater depths, as much as 304 ft bls, as evidenced by samples collected from one well (a reconstructed former production well) near the plant, that contained concentrations of about 240 μg/L and 508 ng/L, respectively. The 2020 data also indicate that TCE and PFAS concentrations which exceed drinking-water MCL or HA levels are present in groundwater depths of less than 200 ft in an area that extends predominantly in a northeast direction from the former Chromatex Plant, and is apparently influenced by hydraulic gradients, lithology, and geologic structure.

Pennsylvania

Borehole geophysical logging and aquifer-isolation tests conducted in well MG-1693 at North Penn Area 5 Superfund Site near Colmar, Montgomery County, Pennsylvania

Borehole geophysical logging and aquifer-isolation (packer) tests were conducted in well MG-1693 (NP-87) at the North Penn Area 5 Superfund Site near Colmar, Montgomery County, Pa. Objectives of the study were to identify the depth and yield of water-bearing zones, occurrence of vertical borehole flow, and effects of pumping on water levels in nearby wells. Caliper, natural-gamma, single-point-resistance, fluidtemperature, fluid-resistivity, heatpulse-flowmeter, and borehole-video logs were collected. Vertical borehole-fluid movement direction and rate were measured under nonpumping conditions. The suite of logs was used to locate water-bearing fractures, determine zones of vertical borehole-fluid movement, and select depths to set packers. Aquifer-isolation tests were conducted to sample discrete intervals and to determine specific capacities of water-bearing zones and effects of pumping individual zones on water levels in two nearby monitor wells. Specific capacities of isolated zones during aquifer-isolation tests ranged from 0.03 to 3.09 (gal/min)/ft (gallons per minute per foot). Fractures identified by borehole geophysical methods as water-producing or water-receiving zones produced water when isolated and pumped. Water enters the borehole primarily through high-angle fractures at 416 to 435 ft bls (feet below land surface) and 129 to 136 ft bls. Water exits the borehole through a high-angle fracture at 104 to 107 ft bls, a broken casing joint at 82 ft bls, and sometimes as artesian flow through the top of the well. Thirteen intervals were selected for aquifer-isolation testing, using a straddle-packer assembly. The specific capacity of interval 1 was 2.09 (gal/min)/ft. The specific capacities of intervals 2, 3, and 4 were similar—0.27, 0.30, and 0.29 (gal/min)/ft, respectively. The specific capacities of intervals 5, 6, 7, 8, and 10 were similar—0.03, 0.04, 0.09, 0.09, and 0.04 (gal/min)/ft, respectively. Intervals 9, 11, and 12 each showed a strong hydraulic connection outside the borehole with intervals above and below the isolated interval. The specific capacities of intervals 9, 11, 12, and 13 were similar—2.12, 2.17, 3.09, and 3.08 (gal/min)/ft, respectively. The aquifer-isolation tests indicate that wells MG-1693 (NP-87) and MG-924 (NP-21) are connected primarily through the high-angle fracture from 416 to 435 ft bls. Pumping in either of these wells directly impacts the other well, allowing the pumped well to draw from water-bearing zones in the nonpumped well that are not present in or are not connected directly to the pumped well. The two boreholes act as a single, U-shaped well. The aquifer-isolation tests also show that the lower zones in well MG-1693 (NP-87) are a major source of hydraulic head in well MG-1661 (W-13) through the broken casing joint at 82 ft bls. Water moving upward from the lower intervals in well MG-1693 (NP-87) exits the borehole through the broken casing joint, moves upward outside the borehole, possibly around and (or) through a poor or damaged casing seal, and through the weathered zone above bedrock to well MG-1661 (W-13). Samples for volatile organic compounds (VOCs) were collected in nine isolated intervals. Six compounds were detected (1,1-dichloroethane, 1,1-dichloroethene, cis-1,2-dichloroethene, toluene, 1,1,1-trichloroethane, and trichloroethene (TCE)), and TCE was found in all nine isolated intervals. Intervals 4 (124-149 ft bls) and 6 (277-302 ft bls) had the highest total concentration of VOCs (6.66 and 6.2 micrograms per liter, respectively). Intervals 1 (68-93 ft bls) and 4 each had five compounds detected, which was the highest number of compounds detected. Interval 5 (252-277 ft bls) had the lowest total concentration of VOCs (0.08 microgram per liter) and the least number of VOCs detected (one). Detected compounds were not evenly distributed throughout the intervals. Contaminants were found in shallow, intermediate, and deep intervals and were associated with high-angle fractures and rough areas that showed no distinct fractures.

Pennsylvania