Search USGSSearch

SEARCH · Search USGS

Results for “Test”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Summary of aquifer test data for Arkansas – 1940-2006

As demands on Arkansas's ground water continue to increase, decision-makers need all available information to ensure the sustainability of this important natural resource. From 1940 through 2006, the U.S. Geological Survey has conducted over 300 aquifer tests in Arkansas. Much of these data never have been published. This report presents the results from 206 of these aquifer tests from 21 different hydrogeologic units spread across 51 Arkansas counties. Ten of the hydrogeologic units are within the Atlantic Plain of Arkansas and consist mostly of unconsolidated and semi-consolidated deposits. The remaining 11 units are within the Interior Highlands consisting mainly of consolidated rock. Descriptive statistics are reported for each hydrologic unit with two or more tests, including the mean, minimum, median, maximum and standard deviation values for specific capacity, transmissivity, hydraulic conductivity, and storage coefficient. Hydraulic conductivity values for the major water-bearing hydrogeologic units are estimated because few conductivity values are recorded in the original records. Nearly all estimated hydraulic conductivity values agree with published hydraulic conductivity values based on the hydrogeologic unit material types. Similarly, because few specific capacity values were available in the original aquifer test records, specific capacity values are estimated for individual wells.

Arkansas

Design and Performance of an Enhanced Bioremediation Pilot Test in a Tidal Wetland Seep, West Branch Canal Creek, Aberdeen Proving Ground, Maryland

Because of a lack of available in situ remediation methods for sensitive wetland environments where contaminated groundwater discharges, the U.S. Geological Survey, in cooperation with the U.S. Army Garrison, Aberdeen Proving Ground, Maryland, conceived, designed, and pilot tested a permeable reactive mat that can be placed horizontally at the groundwater/surface-water interface. Development of the reactive mat was part of an enhanced bioremediation study in a tidal wetland area along West Branch Canal Creek at Aberdeen Proving Ground, where localized areas of preferential discharge (seeps) transport groundwater contaminated with carbon tetrachloride, chloroform, tetrachloroethene, trichloroethene, and 1,1,2,2-tetrachloroethane from the Canal Creek aquifer to land surface. The reactive mat consisted of a mixture of commercially available organic- and nutrient-rich peat and compost that was bioaugmented with a dechlorinating microbial consortium, WBC-2, developed for this study. Due to elevated chlorinated methane concentrations in the pilot test site, a layer of zero-valent iron mixed with the peat and compost was added at the base of the reactive mat to promote simultaneous abiotic and biotic degradation. The reactive mat for the pilot test area was designed to optimize chlorinated volatile organic compound degradation efficiency without altering the geotechnical and hydraulic characteristics, or creating undesirable water quality in the surrounding wetland area, which is referred to in this report as achieving geotechnical, hydraulic, and water-quality compatibility. Optimization of degradation efficiency was achieved through the selection of a sustainable organic reactive matrix, electron donor, and bioaugmentation method. Consideration of geotechnical compatibility through design calculations of bearing capacity, settlement, and geotextile selection showed that a 2- to 3-feet tolerable thickness of the mat was possible, with 0.17 feet settlement predicted for unconsolidated sediments between 1.5 and 6 years following installation of the reactive mat. To ensure hydraulic compatibility in the mat design, mat materials that had a hydraulic conductivity greater than the surrounding wetland sediments were selected, and the mixture was optimized to consist of 1.5 parts compost, 1.5 parts peat and 1 part sand as a safeguard against fluidization. Sediment and matrix properties also indicated that a nonwoven geotextile with a cross-plane flow greater than that of the native sediments was suitable as the base of the reactive mat. Another nonwoven geotextile was selected for installation between the iron mix and organic zones of the mat to create more laminar flow conditions within the mat. Total metals and sequential extraction procedure analyses of mat materials, which were conducted to evaluate water-quality compatibility of the mat materials, showed that concentrations of metals in the compost ranged from one-half to one order of magnitude below consensus-based probable effect concentrations in sediment. A 22-inch-thick reactive mat, containing 0.5 percent WBC-2 by volume, was constructed at seep area 3-4W and monitored from October 2004 through October 2005 for the pilot test. No local, immediate failure of the mat or of wetland sediments was observed during mat installation, indicating that design estimates of bearing capacity and geotextile textile selection ensured the integrity of the mat and wetland sediments during and following installation. Measurements of surface elevation of the mat showed an average settlement of the mat surface of approximately 0.25 feet after 10 months, which was near the predicted settlement for unconsolidated sediment. Monitoring showed rapid establishment and sustainment throughout the year of methanogenic conditions conducive to anaerobic biodegradation and efficient dechlorination activity by WBC-2. The median mass removal of chloromethanes and total chloroethenes and ethane during the

Scientific Investigations Report

Evaluation of the expected moments algorithm and a multiple low-outlier test for flood frequency analysis at streamgaging stations in Arizona

Flooding is among the costliest natural disasters in terms of loss of life and property in Arizona, which is why the accurate estimation of flood frequency and magnitude is crucial for proper structural design and accurate floodplain mapping. Current guidelines for flood frequency analysis in the United States are described in Bulletin 17B (B17B), yet since B17B’s publication in 1982 (Interagency Advisory Committee on Water Data, 1982), several improvements have been proposed as updates for future guidelines. Two proposed updates are the Expected Moments Algorithm (EMA) to accommodate historical and censored data, and a generalized multiple Grubbs-Beck (MGB) low-outlier test. The current guidelines use a standard Grubbs-Beck (GB) method to identify low outliers, changing the determination of the moment estimators because B17B uses a conditional probability adjustment to handle low outliers while EMA censors the low outliers. B17B and EMA estimates are identical if no historical information or censored or low outliers are present in the peak-flow data. EMA with MGB (EMA-MGB) test was compared to the standard B17B (B17B-GB) method for flood frequency analysis at 328 streamgaging stations in Arizona. The methods were compared using the relative percent difference (RPD) between annual exceedance probabilities (AEPs), goodness-of-fit assessments, random resampling procedures, and Monte Carlo simulations. The AEPs were calculated and compared using both station skew and weighted skew. Streamgaging stations were classified by U.S. Geological Survey (USGS) National Water Information System (NWIS) qualification codes, used to denote historical and censored peak-flow data, to better understand the effect that nonstandard flood information has on the flood frequency analysis for each method. Streamgaging stations were also grouped according to geographic flood regions and analyzed separately to better understand regional differences caused by physiography and climate. The B17B-GB and EMA-MGB RPD-boxplot results showed that the median RPDs across all streamgaging stations for the 10-, 1-, and 0.2-percent AEPs, computed using station skew, were approximately zero. As the AEP flow estimates decreased (that is, from 10 to 0.2 percent AEP) the variability in the RPDs increased, indicating that the AEP flow estimate was greater for EMA-MGB when compared to B17B-GB. There was only one RPD greater than 100 percent for the 10- and 1-percent AEP estimates, whereas 19 RPDs exceeded 100 percent for the 0.2-percent AEP. At streamgaging stations with low-outlier data, historical peak-flow data, or both, RPDs ranged from −84 to 262 percent for the 0.2-percent AEP flow estimate. When streamgaging stations were separated by the presence of historical peak-flow data (that is, no low outliers or censored peaks) or by low outlier peak-flow data (no historical data), the results showed that RPD variability was greatest for the 0.2-AEP flow estimates, indicating that the treatment of historical and (or) low-outlier data was different between methods and that method differences were most influential when estimating the less probable AEP flows (1, 0.5, and 0.2 percent). When regional skew information was weighted with the station skew, B17B-GB estimates were generally higher than the EMA-MGB estimates for any given AEP. This was related to the different regional skews and mean square error used in the weighting procedure for each flood frequency analysis. The B17B-GB weighted skew analysis used a more positive regional skew determined in USGS Water Supply Paper 2433 (Thomas and others, 1997), while the EMA-MGB analysis used a more negative regional skew with a lower mean square error determined from a Bayesian generalized least squares analysis. Regional groupings of streamgaging stations reflected differences in physiographic and climatic characteristics. Potentially influential low flows (PILFs) were more prevalent in arid regions of the State, and generally AEP flows were larger with EMA-MGB than with B17B-GB for gaging stations with PILFs. In most cases EMA-MGB curves would fit the largest floods more accurately than B17B-GB. In areas of the State with more baseflow, such as along the Mogollon Rim and the White Mountains, streamgaging stations generally had fewer PILFs and more positive skews, causing estimated AEP flows to be larger with B17B-GB than with EMA-MGB. The effect of including regional skew was similar for all regions, and the observed pattern was increasingly greater B17B-GB flows (more negative RPDs) with each decreasing AEP quantile. A variation on a goodness-of-fit test statistic was used to describe each method’s ability to fit the largest floods. The mean absolute percent difference between the measured peak flows and the log-Pearson Type 3 (LP3)-estimated flows, for each method, was averaged over the 90th, 75th, and 50th percentiles of peak-flow data at each site. In most percentile subsets, EMA-MGB on average had smaller differences (1 to 3 percent) between the observed and fitted value, suggesting that the EMA-MGB-LP3 distribution is fitting the observed peak-flow data more precisely than B17B-GB. The smallest EMA-MGB percent differences occurred for the greatest 10 percent (90th percentile) of the peak-flow data. When stations were analyzed by USGS NWIS peak flow qualification code groups, the stations with historical peak flows and no low outliers had average percent differences as high as 11 percent greater for B17B-GB, indicating that EMA-MGB utilized the historical information to fit the largest observed floods more accurately. A resampling procedure was used in which 1,000 random subsamples were drawn, each comprising one-half of the observed data. An LP3 distribution was fit to each subsample using B17B-GB and EMA-MGB methods, and the predicted 1-percent AEP flows were compared to those generated from distributions fit to the entire dataset. With station skew, the two methods were similar in the median percent difference, but with weighted skew EMA-MGB estimates were generally better. At two gages where B17B-GB appeared to perform better, a large number of peak flows were deemed to be PILFs by the MGB test, although they did not appear to depart significantly from the trend of the data (step or dogleg appearance). At two gages where EMA-MGB performed better, the MGB identified several PILFs that were affecting the fitted distribution of the B17B-GB method. Monte Carlo simulations were run for the LP3 distribution using different skews and with different assumptions about the expected number of historical peaks. The primary benefit of running Monte Carlo simulations is that the underlying distribution statistics are known, meaning that the true 1-percent AEP is known. The results showed that EMA-MGB performed as well or better in situations where the LP3 distribution had a zero or positive skew and historical information. When the skew for the LP3 distribution was negative, EMA-MGB performed significantly better than B17B-GB and EMA-MGB estimates were less biased by more closely estimating the true 1-percent AEP for 1, 2, and 10 historical flood scenarios.

Arizona

Hydraulic conductivity estimates from slug tests in the Big Sioux aquifer near Sioux Falls, South Dakota

Hydraulic conductivity estimates were made for 15 observation wells using slug-out (rising-head) tests in the Big Sioux aquifer near Sioux Falls, South Dakota, as part of a cooperative study with the City of Sioux Falls to characterize the hydrogeology and the extent of the Big Sioux aquifer north of the city. Well and aquifer data were collected from field measurements and drillers’ logs. Multiple slug tests were completed at each observation well with a transducer to record the change in water level and a U.S. Geological Survey standard mechanical slug to displace the well’s water column. In total, 110 slug-out test trials were completed among the 15 observation wells. Hydraulic conductivity was estimated by curve fitting with AQTESOLV Pro version 4.50.002. Hydraulic conductivity estimates ranged from 64 to 379 feet per day (ft/d). The mean, standard deviation, and median hydraulic conductivity for the 110 slug-out test trials were 171 ft/d, 73 ft/d, and 157 ft/d, respectively. The mean hydraulic conductivity calculated for each well ranged from 88 to 270 ft/d, the standard deviation ranged from 7 to 66 ft/d, and the median hydraulic conductivity ranged from 86 to 256 ft/d.

South Dakota

Hydraulic conductivity and transmissivity estimates from slug tests in wells within the Mississippi Alluvial Plain, Arkansas and Mississippi, 2020

During the spring and summer of 2020, the U.S. Geological Survey conducted single-well slug tests on selected observation wells within the Mississippi Alluvial Plain in Arkansas and Mississippi to estimate hydraulic conductivity and transmissivity values for the Mississippi River Valley alluvial and middle Claiborne aquifers. Well and aquifer data were collected from field measurements, well-construction reports, and published aquifer-thickness information. A total of 324 slug-in and slug-out tests were conducted on 48 wells by using mechanical slugs to displace the water column and submersible pressure transducers to record changes in water levels in the wells. Hydraulic conductivity of the aquifers in which the wells are screened was estimated by curve fitting the water-level-change data using aquifer test analysis software. Estimates of aquifer transmissivity were made by multiplying the estimated hydraulic conductivity value by the aquifer thickness at well locations. Mean hydraulic conductivity estimates for 44 observation wells screened in the Mississippi River Valley alluvial aquifer range from 3 to 401 feet per day, and mean transmissivity estimates range from 285 to 80,559 feet squared per day. Mean hydraulic conductivity estimates for four observation wells screened in units of the middle Claiborne aquifer range from 0.14 to 183 feet per day, and mean transmissivity estimates range from 55 to 67,913 feet squared per day. The results from these tests can be used to improve the understanding of water availability and groundwater migration, to refine groundwater models, and to ultimately provide stakeholders and decisionmakers better information for management of the groundwater resources within the Mississippi Alluvial Plain.

Arkansas, Mississippi

Evaluation of borehole geophysical logs and hydraulic tests, phase III, at AIW Frank/Mid-County Mustang Superfund Site, Chester County, Pennsylvania

Borehole geophysical logs, heatpulse-flowmeter measurements, and aquifer-isolation tests were used to characterize the ground-water-flow system at the AIW Frank/Mid-County Mustang Superfund Site. The site is underlain by fractured carbonate rocks. Caliper, natural-gamma, single-point-resistance, fluid-resistivity, and fluid-temperature logs were run in six wells, and an acoustic borehole televiewer and borehole deviation log was run in one well. The direction and rate of borehole-fluid movement was measured with a high-resolution heatpulse flowmeter for both nonpumping and pumping conditions in four wells. The heatpulse-flowmeter measurements showed flow within the borehole during nonpumping conditions in three of the four wells tested. Flow rates up to 1.4 gallons per minute were measured. Flow was upward in one well and both upward and downward in two wells. Aquifer-isolation (packer) tests were conducted in four wells to determine depth-discrete specific capacity values, to obtain depth-discrete water samples, and to determine the effect of pumping an individual fracture or fracture zone in one well on water levels in nearby wells. Water-level data collected during aquifer-isolation tests were consistent with and confirmed interpretations of borehole geophysical logs and heatpulse-flowmeter measurements. Seven of the 13 fractures identified as water-producing or water-receiving zones by borehole geophysical methods produced water at a rate equal to or greater than 7.5 gallons per minute when isolated and pumped. The specific capacities of isolated fractures range over three orders of magnitude, from 0.005 to 7.1 gallons per minute per foot. Vertical distribution of specific capacity between land surface and 298 feet below land surface is not related to depth. The four highest specific capacities, in descending order, are at depths of 174-198, 90-92, 118-119, and 34-37 feet below land surface.

Pennsylvania

Testing the sensitivity of pumpage to increases in surficial aquifer system heads in the Cypress Creek well-field area, west-central Florida — An optimization technique

Tampa Bay depends on ground water for most of the water supply. Numerous wetlands and lakes in Pasco County have been impacted by the high demand for ground water. Central Pasco County, particularly the area within the Cypress Creek well field, has been greatly affected. Probable causes for the decline in surface-water levels are well-field pumpage and a decade-long drought. Efforts are underway to increase surface-water levels by developing alternative sources of water supply, thus reducing the quantity of well-field pumpage. Numerical ground-water flow simulations coupled with an optimization routine were used in a series of simulations to test the sensitivity of optimal pumpage to desired increases in surficial aquifer system heads in the Cypress Creek well field. The ground-water system was simulated using the central northern Tampa Bay ground-water flow model. Pumping solutions for 1987 equilibrium conditions and for a transient 6-month timeframe were determined for five test cases, each reflecting a range of desired target recovery heads at different head control sites in the surficial aquifer system. Results are presented in the form of curves relating average head recovery to total optimal pumpage. Pumping solutions are sensitive to the location of head control sites formulated in the optimization problem and as expected, total optimal pumpage decreased when desired target head increased. The distribution of optimal pumpage for individual production wells also was significantly affected by the location of head control sites. A pumping advantage was gained for test-case formulations where hydraulic heads were maximized in cells near the production wells, in cells within the steady-state pumping center cone of depression, and in cells within the area of the well field where confining-unit leakance is the highest. More water was pumped and the ratio of head recovery per unit decrease in optimal pumpage was more than double for test cases where hydraulic heads are maximized in cells located at or near the production wells. Additionally, the ratio of head recovery per unit decrease in pumpage was about three times more for the area where confining-unit leakance is the highest than for other leakance zone areas of the well field. For many head control sites, optimal heads corresponding to optimal pumpage deviated from the desired target recovery heads. Overall, pumping solutions were constrained by the limiting recovery values, initial head conditions, and by upper boundary conditions of the ground-water flow model.

Florida

Field tests of diffusion samplers for inorganic constituents in wells and at a ground-water discharge zone

Field tests were performed on two types of diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. Nylon-screen samplers and dialysis samplers were tested for the collection of arsenic, calcium, chloride, iron, manganese, sulfate, and dissolved oxygen. The investigations were conducted at the Naval Industrial Reserve Ordnance Plant (NIROP), Fridley, Minnesota, and at the Naval Air Station Fort Worth Joint Reserve Base (NAS Fort Worth JRB), Texas. Data indicate that, in general, nylon-screen and dialysis diffusion samplers are capable of obtaining concentrations of inorganic solutes in ground water that correspond to concentrations obtained by low-flow sampling. Diffusion samplers offer a potentially time-saving approach to well sampling. Particular care must be taken, however, when sampling for iron and other metals, because of the potential for iron precipitation by oxygenation and when dealing with chemically stratified sampling intervals. Simple nylon-screen jar samplers buried beneath creekbed sediment appear to be effective tools for locating discharge zones of arsenic contaminated ground water. Although the LDPE samplers have proven to be inexpensive and simple to use in wells, they are limited by their inability to provide a representative sample of ionic solutes. The success of nylon-screen samplers in sediment studies suggests that these simple samplers may be useful for collecting water samples for inorganic constituents in wells. Results using dialysis bags deployed in wells suggest that these types of samplers have the potential to provide a representative sample of both VOCs and ionic solutes from ground water (Kaplan and others, 1991; Theodore A. Ehlke, U.S. Geological Survey, written commun., 2001). The purpose of this report is to provide results of field tests investigating the potential to use diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. The investigations were performed at NIROP, Fridley, Minn. (fig. 1) and at NAS Fort Worth JRB, Texas (fig. 2). Two types of samplers were tested. One type was a nylon-screen sampler, which consisted of a 30-mL jar filled with deionized water, with its opening covered by a nylon screen. The second type was a dialysis sampler that consisted of a tube of dialysis membrane filled with deionized water. The nylon-screen samplers were deployed in wells at NIROP Fridley and NAS Fort Worth JRB and beneath the ground-water/surface water interface of a stream at NAS Fort Worth JRB. The dialysis samplers were deployed only in wells at NAS Fort Worth JRB.

Water-Resources Investigations Report

Results of hydrologic tests and water-chemistry analyses, Wells H-6A, H-6B, and H-6C, at the proposed Waste Isolation Pilot Plant site, southeastern New Mexico

Hydrologic testing was conducted at wells H-6A, H-6B, and H-6C in the northwestern part of the proposed Waste Isolation Pilot Plant site in southeastern New Mexico to define hydraulic properties of three water-bearing zones. The zones tested were the Magenta and Culebra Dolomite Members of the Rustler Formation and the Rustler Formation-Salado Formation contact. The Magenta Dolomite and the Rustler-Salado contact yield water to wells at rates less than 0.5 gallon per minute as determined from shut-in and slug tests. A transmissivity value for the Culebra Dolomite Member was obtained by conducting conventional pumping and recovery tests in well H-6B; this well was pumped at a rate of approximately 11 gallons per minute. Water samples from the Magenta Dolomite Member of the Rustler Formation had a dissolved-solids concentration of 5,760 milligrams per liter. The major chemical constituents of water samples from this zone were sulfate, sodium, and chloride. Water samples from the Culebra Dolomite Member of the Rustler Formation had dissolved-solids concentration of 52,600 milligrams per liter, and samples from the Rustler Formation-Salado Formation contact had 316,000 milligrams per liter; chloride and sodium were the major constituents in the water samples. Radium-266, a naturally occurring radioactive element, was present in samples from all three zones.

New Mexico

Results of geohydrologic test drilling in the eastern Snake River Plain, Gooding County, Idaho

A 1,123-foot test hole was core drilled near Wendell, Idaho, during 1981-82 as part of the Snake River Plain regional aquifer study. An upper basalt unit, an intermediate unconsolidated sedimentary rock unit, and a lower basalt unit were penetrated by the test hole. Drilling verified that the upper several hundred feet of high-resistivity material, as determined by surface electrical soundings, is basalt. Core examination, laboratory analysis, and correlation with other drill holes indicated that the basalt is typical of Quaternary basalt of the Snake River Group. Quaternary basalt in the test hole is 200 feet thick. Correlation with other drill holes and comparison with rock outcrops near the Snake River and in the Snake River canyon suggest that the underlying sediments and lower basalt unit are parts of the Tertiary and Quaternary Glenns Ferry Formation and Tertiary Banbury Basalt. Piezometers in the hole verify upward movement of water in a major discharge area for the regional aquifer. Hydraulic head in the bottom of the hole is about 155 feet higher than the water table. Lithologic sequence in the test hole correlates well with sequences in deep drill holes at scattered locations on the plain. (USGS)

Idaho

Use of double-mass curves to determine drawdown in a long-term aquifer test in north-central Volusia County, Florida

A test well withdrew water from the upper Floridan aquifer system at an average of 530 gallons per minute from June 1978 to July 1979. Ground-water levels were monitored in wells open to the upper Floridan (artesian) aquifer system and in wells open to the surficial (water-table) aquifer. Double-mass curves were used to separate drawdown from natural water-level fluctuations. Drawdowns in the Floridan were 4.3 feet at a site 350 feet away from the pumped well, 4.1 feet at a site 1,000 feet away, 1.0 foot at a site 1.0 mile away, and 0.4 foot at a site 5.8 miles away. After an initial drawdown of 0.2 foot at a surficial aquifer well 1,000 feet from the pumped well, there was some recovery, and long-term drawdown averaged less than 0.2 foot. In a five-day aquifer test during a period of no rainfall in 1976, the ratio of surficial aquifer drawdown to Floridan aquifer system drawdown reached equilibrum at 0.05. The results of the long-term test indicate that this ratio is the upper limit of long-term drawdown because of capture of evapotranspiration and runoff during the long-term test. (USGS)

Water-Resources Investigations Report

Geohydrology of rocks penetrated by test well USW H-4, Yucca Mountain, Nye County, Nevada

Test well USW H-4 is one of several wells drilled in the southwestern part of the Nevada Test Site for hydraulic testing, hydrologic monitoring, and geophysical logging. The work was performed in cooperation with the U.S. Department of Energy. The rocks penetrated by the well to a total depth of 1,219 m were volcanic tuffs of Tertiary age. Hydraulic coefficients calculated from pumping test data indicate that transmissivity ranged from 200 to 790 sq m/day. A radioactive tracer, borehole flow survey indicated that the two most productive zones during this borehole flow survey occurred in the upper part of the Bullfrog Member of the Crater Flat Tuff, depth interval from 721 to 731.5m, and in the underlying part of the Tram Member, depth interval from 864 to 920m. The water is predominantly a sodium biocarbonate type with small concentrations of calcium, magnesium, and sulfate. The apparent age of this composite water sample was determined by carbon-14 date of 17,200 years before present. (USGS)

Water-Resources Investigations Report

Tests for injecting, storing, and recovering freshwater in a saline artesian aquifer, Lee County, Florida

An investigation was made of the suitability of a saline, artesian limestone aquifer for the injection, storage, and recovery of freshwater from the Caloosahatchee River. The tests were conducted on a well tapping a leaky artesian system that has a transmissivity of 800 square feet per day, a storage of 1 x 10-4, and a leakance of 0.01 per day. The specific capacity of the injection well was increased through acidizing and was decreased as a result of well clogging during injection. Three injection tests were made wherein the amounts of freshwater injected, the storage duration, and the quality of water injected varied. Analysis of the test data showed that freshwater recoverability ranged from 9.7 to 38.7 percent of the total injected. Differences were attributed principally to differences in the quality of water injected and storage duration. Repeated injection-recovery cycles probably would result in greater recoverability. Head buildup, nearly 200 feet in one test, was a prime problem related chiefly to clogging from suspended material in the injected water and to bacterial growth at the wellbore-limestone interface. Regular backflushing was required. Total head buildup decreased as a result of acidizing the injection well. No coliforms or fecal streptococcus were noted in the recovered water. Growth of anaerobic bacteria occurred. Changes in the quality of the recovered water included decreases in concentration of dissolved organic carbon by as much as 15 mg/L (milligrams per liter), organic nitrogen by as much as 0.80 mg/L, and nitrate by as much as 0.50 mg/L. Increases were noted in ammonia by 0.40 mg/L, and iron by as much as 0.60 mg/L. These changes are consistent with the presence of an anaerobic bacterial ecosystem.

Florida

Characteristics and properties of the basin-fill aquifer determined from three test wells west of Albuquerque, Bernalillo County, New Mexico

Three test wells were drilled west of Albuquerque; two are on the mesa west of the city, the third well is near the Rio Grande flood plain, west of the river. Test well 1, was drilled to a depth of 1,204 ft. Transmissivity of perforated intervals in the alluvial zone (980-1121 ft) ranged from 3.1 to 3.9 ft sq/day, and horizontal hydraulic conductivity from .02 to .03 ft/day. Vertical hydraulic conductivity of the semiconfining layer between the alluvial and volcanic zones is estimated to range from .00031 to .0031 ft/day. Transmissivity of the volcanic zone (1139-1179 ft) is about 81 ft sq/day, and horizontal hydraulic conductivity is about 2.0 ft/day. Dissolved-iron and manganese concentrations exceed recommended constituent limits for a public water supply. Vertical flow is upward; the potentiometric surface in the volcanic zone is about 2 ft higher than in the alluvial zone. Water levels are about 883 ft below land surface. Test well 2 was drilled to a depth of 1,828 ft below land surface with seven intervals open to the aquifer. During development, fine sand and silt entered the casing, filling it to a depth of 1,500 ft. The dissolved-cadmium concentration exceeds the maximum contaminant level and the dissolved-manganese concentration exceeds the recommended constituent limit for a public water supply. The vertical flow gradient is downward; the potentiometric surface in the middle and lower zones is about 17 ft lower than in the upper zones. Depth to water in the upper zone is about 767 below land surface and in the lower two zones the depth to water is about 784 ft below land surface. Test well 3 was drilled to a depth of 1,050 ft. Only the interval from 490 to 590 ft below land surface could be used to calculate transmissivity which was about 1,300 ft sq/day; horizontal hydraulic conductivity is about 13 ft/day. Quality of water is acceptable for a public water supply. Vertical flow is downward; the potentiometric surface in the deepest interval is about 7 ft lower than that in the uppermost zone. In the shallow interval from 350 to 590 ft below land surface, depth to water is about 24 ft below land surface. In the interval from 710 to 790 ft below land surface, depth to water is about 29 ft below land surface and in the interval from 870 to 1,050 ft below land surface, depth to water is 31 ft below land surface. (Author's abstract)

New Mexico

Geochemistry of artificial-recharge tests in the Oakes aquifer near Oakes, southeastern North Dakota

As part of an artificial-recharge feasibility study, water from the James River was introduced into the Oakes aquifer of southeastern North Dakota by infiltration through a recharge basin. Chemical composition of water in the recharge basin and ground water from two separate flow paths beneath the basin was determined from samples taken during two artificial-recharge tests. Changes between recharge-basin water and ground water from the termination of the flow paths during the spring 1987 test included increases in alkalinity, calcium, sodium, and silica and decreases in pH and dissolved oxygen. Interpretation of processes modifying the chemical composition of recharge water was complicated by mixing of recharge water with pre-existing ground water within the Oakes aquifer. In the summer 1987 test, the recharge basin was lined with a decomposing organic mat. The purpose of the organic mat was to sustain large infiltration rates for a longer period of time and to evaluate the effect of a decomposing organic mat on water quality during sustained recharge-basin operation. Larger infiltration rates with the organic mat in place allowed recharge water to reach the termination of the flow paths prior to apparent mixing with pre-existing ground water for a period of as much as approximately 405 hours of recharge-basin operation. Changes between recharge-basin water and ground water from the termination of the flow paths during the summer 1987 organic-mat test included increases in alkalinity, calcium, and silica and decreases in pH, dissolved oxygen, and total organic carbon. Detected changes between recharge-basin water and ground water from the termination of the flow paths were interpreted using a mass-balance geochemical model. Chemical changes of at least 2 milligrams per liter were modeled in terms of reactions, including those due to respiration of micro-organisms, dissolution of carbon dioxide, possible production of organic acids, dissolution of amorphous silica, cation exchange, and dissolution of carbonate minerals. Generation of organic acids within the decomposing organic mat may cause dissolution of dolomite in the subsurface.

Water-Resources Investigations Report

A computer program (MACPUMP) for interactive aquifer-test analysis

This report introduces MACPUMP (Version 1.0), an aquifer-test-analysis package for use with Macintosh4 computers. The report outlines the input- data format, describes the solutions encoded in the program, explains the menu-items, and offers a tutorial illustrating the use of the program. The package reads list-directed aquifer-test data from a file, plots the data to the screen, generates and plots type curves for several different test conditions, and allows mouse-controlled curve matching. MACPUMP features pull-down menus, a simple text viewer for displaying data-files, and optional on-line help windows. This version includes the analytical solutions for nonleaky and leaky confined aquifers, using both type curves and straight-line methods, and for the analysis of single-well slug tests using type curves. An executable version of the code and sample input data sets are included on an accompanying floppy disk.

Water-Resources Investigations Report

Results of borehole geophysical logging and hydraulic tests conducted in Area D supply wells, former U.S. Naval Air Warfare Center, Warminster, Pennsylvania

Borehole geophysical logging, aquifer tests, and aquifer-isolation (packer) tests were conducted in four supply wells at the former U.S. Naval Air Warfare Center (NAWC) in Warminster, PA, to identify the depth and yield of water-bearing zones, occurrence of borehole flow, and effect of pumping on nearby wells. The study was conducted as part of an ongoing evaluation of ground-water contamination at the NAWC. Caliper, natural-gamma, single-point resistance, fluid resistivity, and fluid temperature logs and borehole television surveys were run in the supply wells, which range in depth from 242 to 560 ft (feet). Acoustic borehole televiewer and borehole deviation logs were run in two of the wells. The direction and rate of borehole-fluid movement under non-pumping conditions were measured with a high-resolution heatpulse flowmeter. The logs were used to locate water-bearing fractures, determine probable zones of vertical borehole-fluid movement, and determine the depth to set packers. An aquifer test was conducted in each well to determine open-hole specific capacity and the effect of pumping the open borehole on water levels in nearby wells. Specific capacities ranged from 0.21 to 1.7 (gal/min)/ft (gallons per minute per foot) of drawdown. Aquifer-isolation tests were conducted in each well to determine depth-discrete specific capacities and to determine the effect of pumping an individual fracture or fracture zone on water levels in nearby wells. Specific capacities of individual fractures and fracture zones ranged from 0 to 2.3 (gal/min)/ft. Most fractures identified as water-producing or water-receiving zones by borehole geophysical methods produced water when isolated and pumped. All hydrologically active fractures below 250 ft below land surface were identified as water-receiving zones and produced little water when isolated and pumped. In the two wells greater then 540 ft deep, downward borehole flow to the deep water-receiving fractures is caused by a large difference in head (as much as greater then 49 ft) between water-bearing fractured in the upper and lower part of the borehole. Vertical distribution of specific capacity between land surface and 250 ft below land surface is not related to depth.

Water-Resources Investigations Report

Hydrogeologic properties of the Ordovician Sinnipee Group at test well BN-483, Better Brite Superfund Site, De Pere, Wisconsin

Test well BN-483, near the Better Brite Superfund Site, was drilled to a total depth of 169 feet below land surface. The Ordovician-age Sinnipee Group, which includes the Galena Dolomite, and the Decorah and Platteville Formations, was encountered from about 25 feet below land surface to a depth of about 160 feet. Analysis of core samples and single-well aquifer tests of the dolomites indicate low matrix porosity (1.8 to 7.7 percent) and low horizontal hydraulic conductivity (5.0 x 10 -4 to 3.4 x 10 -3 feet per day). Significant differences in hydraulic head between Sinnipee Group dolomites and the underlying Sandstone Aquifer (represented by the Glenwood Formation sandstones in test well BN-483) are the result of municipal pumping from the Sandstone Aquifer. The difference in hydraulic head, along with the low porosity and hydraulic conductivity of the Sinnipee Group dolomites, indicates limited hydraulic connection between the Sandstone Aquifer and the shallow aquifer within the glacial sediments. Because of the low hydraulic conductivity of the dolomites, sufficient water for analysis was recovered from only the uppermost interval of test well BN-483 at a depth of 35-52 feet. No inorganic contaminants of environmental concern were detected. Toluene was the only VOC identified, at an estimated concentration of about 2 micrograms/liter.

Wisconsin