Slug tests in unconfined formations: An assessment of the bouwer and rice technique

The slug test is one of the most common techniques for the in situ estimation of hydraulic conductivity in unconfined flow systems. Recently, a mathematical model describing the flow of ground water in response to a slug test in an unconfined flow system has been proposed. This model incorporates the effects of partial penetration, anisotropy, an upper constant-head boundary, and, in its most complete form, well skins of either higher or lower permeability than the formation itself. This model is useful in identifying conditions when conventional approaches (i.e., the Bouwer and Rice model) introduce large errors into parameter estimates. For slug tests performed in homogeneous, isotropic formations that would be classified as aquifers, the Bouwer and Rice model provides estimates within 30% of actual field values. In less-permeable, clay-rich formations, however, estimates may overpredict formation conductivity by more than 100%. The Bouwer and Rice model introduces the largest error (can easily exceed an order of magnitude) in the presence of a low-permeability skin. Uncertainty about anisotropy can also be the source of considerable error. The semianalytical solution to the mathematical model described here can be employed for parameter estimation under conditions when the Bouwer and Rice model introduces unacceptably large errors into parameter estimates. This solution can be rapidly evaluated, allowing easy incorporation into an automated well-test analysis package and/or ready generation of type curves.

Groundwater

Analysis of Slug Tests in Formations of High Hydraulic Conductivity

A new procedure is presented for the analysis of slug tests performed in partially penetrating wells in formations of high hydraulic conductivity. This approach is a simple, spreadsheet-based implementation of existing models that can be used for analysis of tests from confined or unconfined aquifers. Field examples of tests exhibiting oscillatory and nonoscillatory behavior are used to illustrate the procedure and to compare results with estimates obtained using alternative approaches. The procedure is considerably simpler than recently proposed methods for this hydrogeologic setting. Although the simplifications required by the approach can introduce error into hydraulic-conductivity estimates, this additional error becomes negligible when appropriate measures are taken in the field. These measures are summarized in a set of practical field guidelines for slug tests in highly permeable aquifers.

Ground Water

Strategic testing approaches for targeted disease monitoring can be used to inform pandemic decision-making

More than 1.6 million Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) tests were administered daily in the United States at the peak of the epidemic, with a significant focus on individual treatment. Here, we show that objective-driven, strategic sampling designs and analyses can maximize information gain at the population level, which is necessary to increase situational awareness and predict, prepare for, and respond to a pandemic, while also continuing to inform individual treatment. By focusing on specific objectives such as individual treatment or disease prediction and control (e.g., via the collection of population-level statistics to inform lockdown measures or vaccine rollout) and drawing from the literature on capture–recapture methods to deal with nonrandom sampling and testing errors, we illustrate how public health objectives can be achieved even with limited test availability when testing programs are designed a priori to meet those objectives.

PLoS Biology

Conformance testing for the spatial data transfer standard

The Spatial Data Transfer Standard (SDTS) was approved as Federal Information Processing Standard (FIPS) 173, effective February 1993. Federal agencies and geographic information system vendors currently are developing SDTS encoding and decoding capabilities. A program is being developed to test encoders and decoders for conformance to the requirements of SDTS profiles. A series of test points will specify SDTS requirements that can be tested by software or by nonautomated methods. By certifying SDTS products, the conformance testing program will benefit both vendors and users of the SDTS.

Cartography and Geographic Information Systems

Tests for senescent decline in annual survival probabilities of common pochards, Aythya ferina

Senescent decline in survival probabilities of animals is a topic about which much has been written but little is known. Here, we present formal tests of senescence hypotheses, using 1373 recaptures from 8877 duckling (age 0) and 504 yearling Common Pochards (Aythya ferina) banded at a Latvian study site, 1975-1992. The tests are based on capture-recapture models that explicitly incorporate sampling probabilities that, themselves, may exhibit timeand age-specific variation. The tests provided no evidence of senescent decline in survival probabilities for this species. Power of the most useful test was low for gradual declines in annual survival probability with age, but good for steeper declines. We recommend use of this type of capture-recapture modeling and analysis for other investigations of senescence in animal survival rates.

Ecology

Geochemical and isotopic evaluation of groundwater movement in corrective action Unit 97: Yucca Flat/Climax Mine, Nevada Test Site, Nevada, rev. no.: 0

This report describes the results of a comprehensive geochemical evaluation of the groundwater flow system in the Yucca Flat/Climax Mine Corrective Action Unit (CAU). The main objectives of this study are to identify probable pathways for groundwater flow within the study area and to develop constraints on groundwater transit times between selected data collection sites. This work provides an independent means of testing and verifying predictive flow models being developed for this CAU using finite element methods. The Yucca Flat/Climax Mine CAU constitutes the largest of six underground test areas on the Nevada Test Site (NTS) specified for remedial action in the ''Federal Facility Agreement and Consent Order''. A total of 747 underground nuclear detonations were conducted in this CAU. Approximately 23 percent of these detonations were conducted below or near the water table, resulting in groundwater contamination in the vicinity and possibly downgradient of these underground test locations. Therefore, a rigorous evaluation of the groundwater flow system in this CAU is necessary to assess potential long-term risks to the public water supply at downgradient locations.

Nevada

Tests of compensatory vs. additive hypotheses of mortality in mallards

Band recovery data from over 410 000 adult Mallards ( Anas platyrhynchos ) banded in North America between 1950 and 1979 were analyzed to examine the effect of exploitation on annual survival rate. Two extreme hypotheses were defined: completely compensatory, and totally additive, and an explicit mathematical model was presented to represent each hypothesis. Comparison of the values of the log-likelihood functions at their maxima allowed discrimination between the two models (hypotheses). Extensive Monte Carlo studies were made on the performance of the discriminant test and the power of the test under the two extreme hypotheses and a range of intermediate hypotheses. The results of the discriminant tests on the data agreed closely with the expected performance of the test if the true underlying process was compensatory. We rejected the hypothesis of total additivity ( P =.001). Instead, it appears that hunting mortalities are largely compensated for by other forms of mortality.

Ecology

Estimating breeding proportions and testing hypotheses about costs of reproduction with capture-recapture data

The proportion of animals in a population that breeds is an important determinant of population growth rate. Usual estimates of this quantity from field sampling data assume that the probability of appearing in the capture or count statistic is the same for animals that do and do not breed. A similar assumption is required by most existing methods used to test ecologically interesting hypotheses about reproductive costs using field sampling data. However, in many field sampling situations breeding and nonbreeding animals are likely to exhibit different probabilities of being seen or caught. In this paper, we propose the use of multistate capture-recapture models for these estimation and testing problems. This methodology permits a formal test of the hypothesis of equal capture/sighting probabilities for breeding and nonbreeding individuals. Two estimators of breeding proportion (and associated standard errors) are presented, one for the case of equal capture probabilities and one for the case of unequal capture probabilities. The multistate modeling framework also yields formal tests of hypotheses about reproductive costs to future reproduction or survival or both fitness components. The general methodology is illustrated using capture-recapture data on female meadow voles, Microtus pennsylvanicus. Resulting estimates of the proportion of reproductively active females showed strong seasonal variation, as expected, with low breeding proportions in midwinter. We found no evidence of reproductive costs extracted in subsequent survival or reproduction. We believe that this methodological framework has wide application to problems in animal ecology concerning breeding proportions and phenotypic reproductive costs.

Ecology

Hydraulic testing of hole UA-1-HTH-1, Amchitka Island, Alaska

Total depth of the hole was 1,054 meters (3,458 feet) but, because of borehole erosion and bridging, only about 198 meters (650 feet) of the hole was·hydraulically tested with straddle packers. Some information was obtained on the lower part of the hole by use of the pressure recorders which are used with the straddle packers. The heads below land surface in that part of the hole tested with. straddle packers. ranged from·3.9 meters {12.7 feet) in the .. interval 80.5 to 125. 0. meters (264- to 410 feet), the uppermost zone tested with straddle packers, to 5.1 meters (18.6 feet) in the interval 227.4 to 278.6 meters (.746 to 914 feet), the lowermost part of the hole tested with straddle packers. The composite static water level obtained following a pumping test.was 5.5 meters (18,0 feet). The composite head below 278.6 meters (914 feet), determined from a pressure recorder, was about 12.2 meters (40 feet). The head distribution. indicates a decreasing· head with depth. Water samples were collected from two intervals for chemical, radiochemical, and C-14 analysis. The unadjusted age of water in the interval 183.5 to 234.7 meters (602 to 770. feet) was determined to be 8,410 years, and for the interval 227.4 to 278.6 meters (746 to 914 feet) was 17,880 years. After adjustment the.ages of the waters may be less; however, they would still be. in the thousands of years and the relative difference probably would still be real.

Alaska

Seismic activity during the 1968 test pumping at the Rocky Mountain Arsenal disposal well

During the 1968 pumping tests at the Rocky Mountain Arsenal disposal welt, the U.S. Geological Survey was responsible for monitoring earthquakes occurring in the area of the arsenal and making chemical analysis of the fluids removed, three criteria were established to suspend the pumping if anomalous earthquake activity occurred during the pumping test. These criteria were based on the frequency, magnitude, and location of the local earthquakes. The pumping program consisted of four tests which occurred between September 3 and October 26, 1968. During periods of pumping, earthquake activity remained within acceptable limits and no suspensions of the pumping were required. After each of the two major pumping periods an increase in the frequency of small earthquakes occurred. During the first of these two periods of high seismic activity the Geological Survey recommended a delay in the start of the next phase of the pumping until the activity subsided. Most of the earthquakes during 1968 occurred northwest of the arsenal; however, in the 2? month period after the start of the test, a larger percent of the earthquakes occurred on the arsenal than in the previous 8-month period. The temperature in the cooled zone at the bottom of the well was 12?F warmer 2 weeks after pumping stopped than it was in January 1968. Preliminary chemical analyses indicate that very little mixing between waste fluids and connate water bas occurred.

Circular

Preliminary model of the pre-Tertiary basement rocks beneath Yucca Flat, Nevada Test Site, Nevada, based on analysis of gravity and magnetic data

The Environmental Restoration Program of the U.S. Department of Energy, Nevada Operations Office, was developed to investigate the possible consequences to the environment of 40 years of nuclear testing on the Nevada Test Site. The majority of the tests were detonated underground, introducing contaminants into the ground-water system (Laczniak and others, 1996). An understanding of the ground-water flow paths is necessary to evaluate the extent of ground-water contamination. This report provides information specific to Yucca Flat on the Nevada Test Site. Critical to understanding the ground-water flow beneath Yucca Flat is an understanding of the subsurface geology, particularly the structure and distribution of the pre-Tertiary rocks, which comprise both the major regional aquifer and aquitard sequences (Winograd and Thordarson, 1975; Laczniak and others, 1996). Because the pre-Tertiary rocks are not exposed at the surface of Yucca Flat their distribution must be determined through well logs and less direct geophysical methods such as potential field studies. In previous studies (Phelps and others, 1999; Phelps and Mckee, 1999) developed a model of the basement surface of the Paleozoic rocks beneath Yucca Flat and a series of normal faults that create topographic relief on the basement surface. In this study the basement rocks and structure of Yucca Flat are examined in more detail using the basement gravity anomaly derived from the isostatic gravity inversion model of Phelps and others (1999) and high-resolution magnetic data, as part of an effort to gain a better understanding of the Paleozoic rocks beneath Yucca Flat in support of groundwater modeling.

Nevada

Results of Test-Hole Drilling in Well-Field Areas North of Tampa, Florida

A total of 32 test holes were drilled in well-field areas of Hillsborough, Pasco, and Pinellas Counties in the early 1970's to collect information on the hydraulic and geologic properties of shallow formations overlying the Upper Floridan aquifer. Lithologic profiles were compiled and geohydrologic units identified for each test hole. At most test holes, natural-gamma logs were run to identify the confining unit that separates the surficial aquifer system from the Upper Floridan aquifer. Selected core samples were analyzed in the laboratory for vertical hydraulic conductivity, grain size, sorting, specific gravity, effective porosity, cation-exchange capacity, and mineralogy. Following drilling, casing was installed in each test hole and water levels were monitored. The data were used in the preparation of regional water-level maps and in the construction of a numerical model of ground-water flow in the well-field areas.

Open-File Report

Analytical results from ground-water sampling using a direct-push technique at the Dover National Test Site, Dover Air Force Base, Delaware, June-July 2001

A joint study by the Dover National Test Site and the U.S. Geological Survey was conducted from June 27 through July 18, 2001 to determine the spatial distribution of the gasoline oxygenate additive methyl tert-butyl ether and selected water-quality constituents in the surficial aquifer underlying the Dover National Test Site at Dover Air Force Base, Delaware. The study was conducted to support a planned enhanced bio-remediation demonstration and to assist the Dover National Test Site in identifying possible locations for future methyl tert-butyl ether remediation demonstrations. This report presents the analytical results from ground-water samples collected during the direct-push ground-water sampling study. A direct-push drill rig was used to quickly collect 115 ground-water samples over a large area at varying depths. The ground-water samples and associated quality-control samples were analyzed for volatile organic compounds and methyl tert-butyl ether by the Dover National Test Site analytical laboratory. Volatile organic compounds were above the method reporting limits in 59 of the 115 ground-water samples. The concentrations ranged from below detection limits to maximum values of 12.4 micrograms per liter of cis-1,2-dichloroethene, 1.14 micrograms per liter of trichloroethene, 2.65 micrograms per liter of tetrachloroethene, 1,070 micrograms per liter of methyl tert-butyl ether, 4.36 micrograms per liter of benzene, and 1.8 micrograms per liter of toluene. Vinyl chloride, ethylbenzene, p,m-xylene, and o-xylene were not detected in any of the samples collected during this investigation. Methyl tert-butyl ether was detected in 47 of the 115 ground-water samples. The highest methyl tert-butyl ether concentrations were found in the surficial aquifer from -4.6 to 6.4 feet mean sea level, however, methyl tert-butyl ether was detected as deep as -9.5 feet mean sea level. Increased methane concentrations and decreased dissolved oxygen concentrations were found in samples that contained methyl tert-butyl ether.

Open-File Report

An operation manual for a time-series, storm-activated suspended sediment sampler deployed in the coastal ocean: function, maintenance, and testing procedures

This manual describes the operation and testing procedures for two models of a multi-port suspended sediment sampler that are moored in the coastal ocean and that collect samples on a programmable time schedule that can be interrupted to collect during a storm. The ability to sense and collect samples before, during, and after the height of a storm is a unique feature of these instruments because it provides samples during conditions when it is difficult or impossible to sample from a surface ship. The sensors used to trigger storm sampling are a transmissometer or a pressure sensor. The purpose of such samples is to assess composition and concentration of sediment resuspended from the seafloor during storms and subsequently transported within the coastal system. Both light transmission and the standard deviation of pressure from surface waves correlate with the passage of major storms. The instruments successfully identified the onset of storms and collected samples before, during, and after the storm maximum as programmed. The accuracy of determining suspended matter concentrations collected by the sediment sampler has not been fully evaluated. Preliminary laboratory tests using a suspension of muddy sediment collected in a near-bottom sediment trap yielded excellent results. However in laboratory tests with different sediment types, the suspended matter concentrations determined with these samplers became less accurate with increasing average grain size. Future calibration work is necessary and should be conducted in a facility that ideally has a water depth of at least 30 feet to prevent cavitation of the pump that draws sea water through the filters. The test facility should also have the capability for adding suspended matter of known composition and concentration to a fixed volume of seawater that is well mixed.

Open-File Report

Preliminary testing of the role of exercise and predator recognition for bonytail and razorback sucker

Hatchery-reared juvenile, <25-cm TL (total length), razorback suckers appeared curious and showed no sign of predator avoidance when initially placed with large (>45-cm TL) flathead catfish. Predator-na&iuml;ve juveniles (20- to 25-cm TL) exhibited no discernable preference when provided areas with and without (52 percent and 48 percent, n = 16 observations; 46 percent and 54 percent, n = 20 observations) large flathead catfish. However, once predation occurred, use of predator-free areas nearly doubled in two trials (36 percent and 64 percent, n = 50 observations; 33 percent and 67 percent, n = 12 observations). A more stringent test examining available area indicated predator-savvy razorback suckers used predator-free areas (88 percent, n = 21) illustrating predator avoidance was a learned behavior. Razorback suckers exercised (treatment) in water current (<0.3 m/s) for 10 weeks exhibited greater swimming stamina than unexercised, control fish. When exercised and unexercised razorback suckers were placed together with large predators in 2006, treatment fish had significantly fewer (n = 9, z = 1.69, p = 0.046) mortalities than control fish, suggesting increased stamina improved predator escape skills. Predator/prey tests comparing razorback suckers that had been previously exposed to a predation event with control fish, found treatment fish also had significantly fewer losses than predatorna&iuml;ve fish (p = 0.017). Similar tests exposing predator-savvy and predator-na&iuml;ve bonytail with largemouth bass showed a similar trend; predator-savvy bonytail suffered 38 percent fewer losses than control fish. However, there was not a statistically significant difference between the test groups (p = 0.143) due to small sample size. All exercise and predator exposure trials increased the survival rate of razorback sucker and bonytail compared to untreated counterparts.

Open-File Report

Flow-log analysis for hydraulic characterization of selected test wells at the Indian Point Energy Center, Buchanan, New York

Flow logs from 24 test wells were analyzed as part of the hydraulic characterization of the metamorphosed and fractured carbonate bedrock at the Indian Point Energy Center in Buchanan, New York. The flow logs were analyzed along with caliper, optical- and acoustic-televiewer, and fluid-resistivity and temperature logs to determine the character and distribution of fracture-flow zones and estimate their transmissivities and hydraulic heads. Many flow zones were associated with subhorizontal to shallow-dipping fractured zones, southeast-dipping bedding fractures, northwest-dipping conjugate fractures, or combinations of bedding and conjugate fractures. Flow-log analysis generally provided reasonable first-order estimates of flow-zone transmissivity and head differences compared with the results of conventional hydraulic-test analysis and measurements. Selected results of an aquifer test and a tracer test provided corroborating information in support of the flow-log analysis.

New York

Design and Operation of a Borehole Straddle Packer for Ground-Water Sampling and Hydraulic Testing of Discrete Intervals at U.S. Air Force Plant 6, Marietta, Georgia

A borehole straddle packer was developed and tested by the U.S. Geological Survey to characterize the vertical distribution of contaminants, head, and hydraulic properties in open-borehole wells as part of an ongoing investigation of ground-water contamination at U.S. Air Force Plant 6 (AFP6) in Marietta, Georgia. To better understand contaminant fate and transport in a crystalline bedrock setting and to support remedial activities at AFP6, numerous wells have been constructed that include long open-hole intervals in the crystalline bedrock. These wells can include several discontinuities that produce water, which may contain contaminants. Because of the complexity of ground-water flow and contaminant movement in the crystalline bedrock, it is important to characterize the hydraulic and water-quality characteristics of discrete intervals in these wells. The straddle packer facilitates ground-water sampling and hydraulic testing of discrete intervals, and delivery of fluids including tracer suites and remedial agents into these discontinuities. The straddle packer consists of two inflatable packers, a dual-pump system, a pressure-sensing system, and an aqueous injection system. Tests were conducted to assess the accuracy of the pressure-sensing systems, and water samples were collected for analysis of volatile organic compound (VOCs) concentrations. Pressure-transducer readings matched computed water-column height, with a coefficient of determination of greater than 0.99. The straddle packer incorporates both an air-driven piston pump and a variable-frequency, electronic, submersible pump. Only slight differences were observed between VOC concentrations in samples collected using the two different types of sampling pumps during two sampling events in July and August 2005. A test conducted to assess the effect of stagnation on VOC concentrations in water trapped in the system's pump-tubing reel showed that concentrations were not affected. A comparison was conducted to assess differences between three water-sampling methods - collecting samples from the well by pumping a packer-isolated zone using a submersible pump, by using a grab sampler, and by using a passive diffusion sampler. Concentrations of tetrachloroethylene, trichloroethylene and 1,2-dichloropropane were greatest for samples collected using the submersible pump in the packed-isolated interval, suggesting that the straddle packer yielded the least dilute sample.

Georgia

Guidelines for Standardized Testing of Broadband Seismometers and Accelerometers

Testing and specification of seismic and earthquake-engineering sensors and recorders has been marked by significant variations in procedures and selected parameters. These variations cause difficulty in comparing such specifications and test results. In July 1989, and again in May 2005, the U.S. Geological Survey hosted international pub-lic/private workshops with the goal of defining widely accepted guidelines for the testing of seismological inertial sensors, seismometers, and accelerometers. The Proceedings of the 2005 workshop have been published and include as appendix 6 the report of the 1989 workshop. This document represents a collation and rationalization of a single set of formal guidelines for testing and specifying broadband seismometers and accelerometers.