Search USGS⌕ Search

SEARCH · Search USGS

Results for “Journal of Liquid Chromatography”

Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2Linked to original sources

Determination of submicrogram-per-liter concentrations of caffeine in surface water and groundwater samples by solid-phase extraction and liquid chromatography

A method for determining submicrogram-per-liter concentrations of caffeine in surface water and groundwater samples has been developed. Caffeine is extracted from a 1 L water sample with a 0.5 g graphitized carbon-based solid-phase cartridge, eluted with methylene chloride-methanol (80 + 20, v/v), and analyzed by liquid chromatography with photodiode-array detection. The single-operator method detection limit for organic-free water samples was 0.02 μg/L. Mean recoveries and relative standard deviations were 93 ± 13% for organic- free water samples fortified at 0.04 μg/L and 84 ± 4% for laboratory reagent spikes fortified at 0.5 μg/L. Environmental concentrations of caffeine ranged from 0.003 to 1.44 μg/L in surface water samples and from 0.01 to 0.08 μg/L in groundwater samples.

Journal of AOAC International↗

Identification of polychlorinated biphenyls in two bald eagles by combined gas-liquid chromatography-mass spectrometry

Polychlorinated biphenyls are widely used industrial compounds marketed in the United States under the trade name Aroclor. They have appeared in fish and wildlife tissues in this country and Europe. They are known to be toxic, but more importantly, their presence in samples along with the commonly occurring organochlorine pesticides complicates the analysis to a serious degree, making identification of pesticide residues by GLC without preliminary separation extremely unreliable. Residues of both polychlorinated biphenyls and organochloride pesticides were present in eagle carcasses. Many of the polychlorinated biphenyl components had retention times identical with those of certain organochlorine pesticide residues. Identification was accomplished by preliminary separations on thin layer plates followed by combined GLC- mass spectromtry.

Journal of the Association of Official Analytical ↗

Rapid loss of lampricide from catfish and rainbow trout following routine treatment

Rainbow trout (Oncorhynchus mykiss) and channel catfish (Ictalurus punctatus) were exposed to 3-trifluoromethyl-4-nitrophenol (TFM) and Bayluscide (niclosamide) during a sea lamprey control treatment of the Ford River, located in the upper peninsula of Michigan. Caged fish were exposed to a nominal concentration of 0.02 mg/L of niclosamide for a period of approximately 12 h. Samples of fillet tissue were collected from each fish species before treatment and at 6, 12, 18, 24, 48, 96, and 192 h following the arrival of the block of chemical at the exposure site. The fish were dissected, homogenized, extracted, and analyzed by high-performance liquid chromatography. The major residues found in the fillet tissues were TFM and niclosamide. Niclosamide concentrations were highest 12 h after arrival of the chemical block for rainbow trout (0.0395 ?? 0.0251 ??g/g) and 18 h after arrival of the chemical block for channel catfish (0.0465 ?? 0.0212 ??g/g). Residues decreased rapidly after the block of lampricide had passed and were below the detection limits in fillets of rainbow trout within 24 h and channel catfish within 96 h after the arrival of the lampricide.

Journal of Agricultural and Food Chemistry↗

Gas chromatographic–mass spectrometric fragmentation study of phytoestrogens as their trimethylsilyl derivatives: Identification in soy milk and wastewater samples

An analytical method for the identification of eight plant phytoestrogens (biochanin A, coumestrol, daidzein, equol, formononetin, glycitein, genistein and prunetin) in soy products and wastewater samples was developed using gas chromatography coupled with ion trap mass spectrometry (GC/MS–MS). The phytoestrogens were derivatized as their trimethylsilyl ethers with trimethylchlorosilane (TMCS) and N,O- bis (trimethylsilyl)trifluoroacetamide (BSTFA). The phytoestrogens were isolated from all samples with liquid–liquid extraction using ethyl acetate. Daidzein-d 4 and genistein-d 4 labeled standards were used as internal standards before extraction and derivatization. The fragmentation patterns of the phytoestrogens were investigated by isolating and fragmenting the precursor ions in the ion-trap and a typical fragmentation involved the loss of a methyl and a carbonyl group. Two characteristic fragment ions for each analyte were chosen for identification and confirmation. The developed methodology was applied to the identification and confirmation of phytoestrogens in soy milk, in wastewater effluent from a soy-milk processing plant, and in wastewater (influent and effluent) from a treatment plant. Detected concentrations of genistein ranged from 50,000 μg/L and 2000 μg/L in soy milk and in wastewater from a soy-plant, respectively, to 20 μg/L and <1 μg/L for influent and effluent from a wastewater treatment plant, respectively.

Journal of Chromatography A↗

Accurate mass analysis of ethanesulfonic acid degradates of acetochlor and alachlor using high-performance liquid chromatography and time-of-flight mass spectrometry

Degradates of acetochlor and alachlor (ethanesulfonic acids, ESAs) were analyzed in both standards and in a groundwater sample using high-performance liquid chromatography–time-of-flight mass spectrometry with electrospray ionization. The negative pseudomolecular ion of the secondary amide of acetochlor ESA and alachlor ESA gave average masses of 256.0750±0.0049 amu and 270.0786±0.0064 amu respectively. Acetochlor and alachlor ESA gave similar masses of 314.1098±0.0061 amu and 314.1153±0.0048 amu; however, they could not be distinguished by accurate mass because they have the same empirical formula. On the other hand, they may be distinguished using positive-ion electrospray because of different fragmentation spectra, which did not occur using negative-ion electrospray.

Journal of Chromatography A↗

Reversed-phase thin-layer chromatography of homologs of Antimycin-A and related derivatives

Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

Journal of Chromatography↗

American eels produce and release bile acids that vary across life stage

The American eel ( Anguilla rostrata ) is an imperilled fish hypothesized to use conspecific cues, in part, to coordinate long‐distance migration during their multistage life history. Here, holding water and tissue from multiple American eel life stages was collected and analysed for the presence, profile and concentration of bile acids. Distinct bile acid profiles were identified in glass, elver, yellow eel and silver eel holding waters using ultraperformance liquid chromatography high‐resolution mass spectrometry and principal component analysis. Taurochenodeoxycholic acid, taurodeoxycholic acid, cholic acid, deoxycholic acid, taurolithocholic acid and taurocholic acid were detected in whole tissue of American glass eels and elvers, and in liver, intestine and gallbladder samples of late‐stage yellow eels. Bile acids were not a major component of silver eel washings or tissue. This study is novel because little was previously known about bile acids produced and emitted into the environment by American eels. Future behavioural studies could evaluate whether any bile acids produced by American eels influence conspecific migratory behaviour.

Journal of Fish Biology↗

Elimination pattern of aroclor 1254 components in the bobwhite

The gas-liquid chromatographic profile for Aroclor 1254 did not maintain its integrity in bobwhite quail fed Aroclor 1254 for 14 days and clean food 14 or 42 days thereafter. Absorption of all components occurred at essentially the same rate, as shown by analysis of quail sacrificed within an hour after a single oral dose of Aroclor. Acentonitrile-hexane partitioning altered the peak pattern of the Aroclor 1254 standard. Significant alteration of certain polychlorinated biphenyl isomers appeared to take place. Dechlorination was clearly apparent, and isomeric transformation is suggested.

Journal of Chromatography↗

Determination of alkylphenol and alkylphenolethoxylates in biota by liquid chromatography with detection by tandem mass spectrometry and fluorescence spectroscopy

A quantitative method for the simultaneous determination of octylphenol, nonylphenol and the corresponding ethoxylates (1 to 5) in biota is presented. Extraction methods were developed for egg and fish matrices based on accelerated solvent extraction followed by a solid-phase extraction cleanup, using octadecylsilica or aminopropyl cartridges. Identification and quantitation were accomplished by liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) and compared to the traditional liquid chromatography with fluorescence spectroscopy detection. LC-MS-MS provides high sensitivity and specificity required for these complex matrices and an accurate quantitation with the use of 13C-labeled internal standards. Quantitation limits by LC-MS-MS ranged from 4 to 12 ng/g in eggs, and from 6 to 22 ng/g in fish samples. These methods were successfully applied to osprey eggs from the Chesapeake Bay and fish from the Great Lakes area. Total levels found in osprey egg samples were up to 18 ng/g wet mass and as high as 8.2 ug/g wet mass in the fish samples.

Journal of Chromatography A↗

Chiral-phase high-performance liquid chromatography of rotenoid racemates

The high-performance liquid chromatograhic (HPLC) behavior of parent rotenoids (type I) and the hydroxyl-analogues (type II) on three different chiral stationary phases (CSPs) was studied. Separations of optical isomers were achieved in various degrees depending largely upon the rotenoidal structures and the CSP types employed. Enantiomers of all but elliptone compounds were separable on &beta;-cyclodextrin-bonded silica (CDS). Without exception, the 12a-hydroxyrotenoid antipodes were resolved on Pirkle's phenylglycine-bonded silica (PGS) despite unsuccessful attenmpts to resolve the type I rotenoidal racemates. Conversely, optical resolution of the latter rotenoids was accomplished by using a helical polytriphenylmethylacrylate-coated silica (TPS) column and the observed separation factors (&alpha; values) ranged from 1.14 to 1.90. The results from HPLC of type II rotenoids on TPS (&alpha; = 1.00&ndash;1.63) suggested that variations in E-ring structures had profound influence on the resolution outcome. Conjugated double bonds on the E-ring and the desisopropylation of the five-membered E-ring ot type II rotenoids appeared to be important structural features for chiral recognition involving the TPS substrate. In both reversed-phase (CDS) and normal-pahse (PGS and TPS) HPLC modes, the less polar enantiomers were the 6a&beta;,12a&beta;-rotenoids as observed in most cases, though this relationship was reversed in the cases of deguelin and hydroxyelliptone probably due to conformational effects of rotenoidal ring systems.

Journal of Chromatography↗

High-performance liquid chromatographic resolution and quantification of a dilacton antibiotic mixture (antimycin A)

High-performance liquid chromatographic (HPLC) conditions are presented for the separation and quantitative determination of a homologous antibiotic complex (antimycin A). Combined HPLC and chemical ionization mass spectrometry proved to be exceptionally useful for the structural identification of chromatographic components. Using electrochemical, fluorescence, and ultraviolet detectors, the minimum detectable amounts of the antibiotics were found to be in the ranges 0.10–1.12, 0.31–1.69, and 4.10–28.2 ng, respectively. Advantages of the preparation of Dns derivatives for use in fluorescence detection are discussed. Application of the HPLC technique to the analysis of the antibiotic mixture in organic tissues is demonstrated.

Journal of Chromatography↗

Determination of malachite green residues in the eggs, fry, and adult muscle-tissue of rainbow-trout (Oncorhynchus-mykiss)

Malachite green, an effective antifungal therapeutant used in fish culture, is a known teratogen. We developed a method to simultaneously detect both the chromatic and leuco forms of malachite green residues in the eggs, fry, and adult muscle tissue of rainbow trout ( Oncorhynchus mykiss ). Homogenates of these tissues were fortified with [ 14 C] malachite green chloride and extracted with 1% (v/v) acetic acid in acetonitrile or in methanol. The extracts were partitioned with chloroform, dried, redissolved in mobile phase, and analyzed by liquid chromatography (LC) with postcolumn oxidation of leuco malachite green to the chromatic form. LC fractions were collected every 30 s for quantitation by scintillation counting. Recoveries of total [ 14 C] malachite green chloride residue were 85 and 98% in eggs fortified with labeled malachite green at concentrations of 0.5 and 1.00 μg/g, respectively; 68% in fry similarly fortified at a concentration of 0.65 μg/g; and 66% in muscle homogenate similarly fortified at a level of 1.00 μg/g. The method was tested under operational conditions by exposing adult rainbow trout to 1.00 mg/L [ 14 C] malachite green chloride bath for 1 h. Muscle samples analyzed by sample oxidation and scintillation counting contained 1.3 and 0.5 μg/g total malachite green chloride residues immediately after exposure and after a 5-day withdrawal period, respectively.

Journal of AOAC International↗

Liquid-chromatographic determination of sarafloxacin residues in channel catfish muscle-tissue

A liquid chromatographic method is described for the determination of sarafloxacin hydrochloride residues in channel catfish ( Ictalurus punctatus ) fillets. Sarafloxacin was extracted from fillet tissue with acetonitrile–water (1+1). The extract was centrifuged and the supernatant was partitioned with hexane. The aqueous fraction was filtered through a 0.45 μm filter and evaporated to dryness. The sample was redissolved with 20% acetonitrile–methanol (3 + 2) and 80% trifluoroacetic acid (0.1%), centrifuged, and filtered to remove proteins. Samples were analyzed by chromatography with gradient elution on a C 18 column and with fluorescence detection (excitation at 280 nm and emission above 389 nm). Mean recoveries ranged from 85.4 to 104%, and relative standard deviations ranged from 1.06 to 5.58% in samples spiked at concentrations of 10.0–863.8 ng/g. The method detection limit for sarafloxacin was 1.4 ng/g.

Journal of AOAC International↗

Supercritical fluid carbon dioxide extraction and liquid chromatographic separation with electrochemical detection of methylmercury from biological samples

Using the coupled methods presented in this paper, methylmercury can be accurately and rapidly extracted from biological samples by modified supercritical fluid carbon dioxide and quantitated using liquid chromatography with reductive electrochemical detection. Supercritical fluid carbon dioxide modified with methanol effectively extracts underivatized methylmercury from certified reference materials Dorm-1 (dogfish muscle) and Dolt-2 (dogfish liver). Calcium chloride and water, with a ratio of 5:2 (by weight), provide the acid environment required for extracting methylmercury from sample matrices. Methylmercury chloride is separated from other organomercury chloride compounds using HPLC. The acidic eluent, containing 0.06 mol L-1 NaCl, insures the presence of methylmercury chloride and facilitates the reduction of mercury on a glassy carbon electrode. If dual glassy carbon electrodes are used, a positive peak is observed at -0.65 to -0.70 V and a negative peak is observed at -0.90V with the organomercury compounds that were tested. The practical detection limit for methylmercury is 5 X 10-8 mol L-1 (1 X 10-12 tool injected) when a 20 ??L injection loop is used.

International Journal of Environmental Analytical ↗

Analysis and detection of the herbicides dimethenamid and flufenacet and their sulfonic and oxanilic acid degradates in natural water

Dimethenamid [2-chloro-N-(2,4-dimethyl-3-thienyl)-N-(2-methoxy-1-methylethyl)acetamide] and flufenacet [N-(4-fluorophenyl)-N-(1-methylethyl)-2-(5-(trifluoromethyl)-1,3,4- thiadiazol-2-yl)oxy] were isolated by C-18 solid-phase extraction and separated from their ethanesulfonic acid (ESA) and oxanilic acid (OXA) degradates during their elution using ethyl acetate for the parent compound, followed by methanol for the polar degradates. The parent compounds were detected using gas chromatography-mass spectrometry in selected-ion mode. The ESA and OXA degradates were detected using high-performance liquid chromatography-electrospray mass spectrometry (HPLC-ESPMS) in negative-ion mode. The method detection limits for a 123-mL sample ranged from 0.01 to 0.07 μg/L. These methods are compatible with existing methods and thus allow for analysis of 17 commonly used herbicides and 18 of their degradation compounds with one extraction. In a study of herbicide transport near the mouth of the Mississippi River during 1999 and 2000, dimethenamid and its ESA and OXA degradates were detected in surface water samples during the annual spring flushes. For flufenacet, the only detections at the study site were for the ESA degradates in samples collected at the peak of the herbicide spring flush in 2000. The low frequency of detections in surface water likely is due to dimethenamid and flufenacet being relatively new herbicides. In addition, detectable amounts of the stable degradates have not been detected in ground water.

Journal of Agricultural and Food Chemistry↗

A rapid high-performance liquid-chromatographic method for simultaneously determining the concentrations of TFM and Bayer 73 in water during lampricide treatments

The high-performance liquid-chromatography (HPLC) procedure requires only minutes per sample, is specific, and is relatively sensitive (limit of detection < 0.005 mg/L for both chemicals). A combined buffer (pH 4) and internal standard (3-chlorodiphenylamine) reagent is added to the water sample, which is injected through a Sep Pak C 18 disposable cartridge. The cartridge adsorbs and retains both the lampricides and the internal standard. The quantitative elution of the three chemicals from the cartridge with a small volume of methanol effectively concentrates the sample and provides sample cleanup. The methanol extract is then analyzed directly by HPLC on an MCH 10 reverse phase column by using a methanol:0.01 mol/L acetate buffer (87:13, v:v) as the mobile phase at 2 mL/min and detected by ultraviolet spectrophotometry at 330 (or 254) nm. A microprocessor data system further facilitates the procedure by quantifying off-scale peaks and yielding results directly in units of concentration (mg/L).

Canadian Journal of Fisheries and Aquatic Sciences↗

Determination of vapor pressures for nonpolar and semipolar organic compounds from gas chromatographic retention data

Vapor pressures for nonpolar and moderately polar organochlorine, pyrethroid, and organophosphate insecticides, phthalate esters, and organophosphate flame retardants were determined by capillary gas chromatography (GC). Organochlorines and polycyclic aromatic hydrocarbons with known liquid-phase vapor pressures (P??L) (standard compounds) were chromatographed along with two reference compounds n-C20 (elcosane) and p,p???-DDT on a 1.0-m-long poly(dimethylsiloxane) bonded-phase (BP-1) column to determine their vapor pressures by GC (P??GC). A plot of log P??L vs log P??GC for standard compounds was made to establish a correlation between measured and literature values, and this correlation was then used to compute P??L of test compounds from their measured P??GC. P??L of seven major components of technical chlordane, endosulfan and its metabolites, ??-hexachlorocyclohexane, mirex, and two components of technical toxaphene were determined by GC. This method provides vapor pressures within a factor of 2 of average literature values for nonpolar compounds, similar to reported interlaboratory precisions of vapor pressure determinations. GC tends to overestimate vapor pressures of moderately polar compounds. ?? 1990 American Chemical Society.

Journal of Chemical and Engineering Data↗

Rotenone persistence in freshwater ponds: Effects of temperature and sediment adsorption

The persistence of rotenone was compared between a cement-lined pond (0.04 hectare) and an earthen-bottom pond (0.02 hectare) treated with 5 μL Noxfish/L (250 μg rotenone/L) during spring, summer, and fall. Water temperatures on the days of treatment in each season were 8, 22, and 15°C, respectively. Both ponds were filled with pond water from a common source 1 week before each of the three treatments. Water samples (filtered and unfiltered) and sediment samples were analyzed by high-performance liquid chromatography to monitor the decrease of rotenone until residues were at or below the detection limit (<2.0 μg/L for water and < 25 ng/g for sediments). The loss of rotenone from water generally followed a first-order rate ofdecay. Rotenone disappeared two to three times faster in the earthen pond than in the concrete pond. The rotenone half-life times in the spring, summer, and fall treatments were 3.7, 1.3, and 5.2 d, respectively, in the concrete pond, and 1.8, 0.7, and 1.8 d in the earthen pond. Rates of decay in both ponds were directly correlated with water temperature. Filtered water samples from both ponds contained less rotenone than unfiltered water, indicating that some rotenone was bound to suspended material. The highest concentration of rotenone in sediment samples was 102 ng/g; residues decreased to below the detection limit within 14 d in the spring treatment and within 3 d in the summer and fall treatments.

North American Journal of Fisheries Management↗