Determination of fixed water in rocks by infrared absorption
No abstract available.
SEARCH · Search USGS
Search indexed USGS publications on groundwater, aquifers, geologic maps, mineral resources and earthquakes. Explore source records by subject and place.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available.
No abstract available.
A set of four standard glasses has been prepared which have been doped with 61 different elements at the 500-, 50-, 1-, and 0.02-ppm level. The concentrations of lead, uranium, thorium, and thallium have been determined by isotope dilution mass spectrometry at a number of points in each of the glasses. The results obtained from independent determinations in two laboratories demonstrate the homogeneity of the samples and that precision of the order of 0.5% (95% L.E.) may be obtained by the method even at the 20-ppb level for these elements. The chemical and mass spectrometric procedures necessary are presented.
The new technique of constant potential pulse polarography, In which all pulses are to be the same potential, is presented theoretically and evaluated experimentally. The response obtained is in the form of a faradaic current wave superimposed on a constant capacitative component. Results obtained with a computer-controlled system exhibit a capillary response current similar to that observed In normal pulse polarography. Calibration curves for Pb obtained using a modified commercial pulse polarographic instrument are in good accord with theoretical predictions.
Treated wastewater effluent is a potential environmental point source for antidepressant pharmaceuticals. A quantitative method was developed for the determination of trace levels of antidepressants in environmental aquatic matrixes using solid-phase extraction coupled with liquid chromatography-electrospray ionization tandem mass spectrometry. Recoveries of parent antidepressants from matrix spiking experiments for the individual antidepressants ranged from 72 to 118% at low concentrations (0.5 ng/L) and 70 to 118% at high concentrations (100 ng/L) for the solid-phase extraction method. Method detection limits for the individual antidepressant compounds ranged from 0.19 to 0.45 ng/L. The method was applied to wastewater effluent and samples collected from a wastewater-dominated stream. Venlafaxine was the predominant antidepressant observed in wastewater and river water samples. Individual antidepressant concentrations found in the wastewater effluent ranged from 3 (duloxetine) to 2190 ng/L (venlafaxine), whereas individual concentrations in the waste-dominated stream ranged from 0.72 (norfluoxetine) to 1310 ng/L (venlafaxine).
Anion-exchange and immunoaffinity particle loaded membranes (PLMs) were investigated as a mechanism for the isolation of charged organic analytes from water. Kinetic properties determined theoretically included dynamic capacity, pressure drop (Δ P ), residence and diffusion times ( T r , T d ), and total membrane porosity (ε T ). These properties were confirmed through experimental evaluation, and the PLM method showed significant improvement over conventional solid-phase extraction (SPE) and ion-exchange formats. Recoveries of more than 90% were observed for a variety of test compounds at flow rates up to 70 mL/min (equipment-limited maximum flow rate). A fast-flow immunoaffinity column was developed using antibodies (Abs) attached to the PLMs. Reproducible recoveries (88% ± 4%) were observed at flow rates up to 70 mL/min for the antibody (Ab)-loaded PLMs. Findings indicate increased selectivity over anion-exchange PLMs and conventional SPE or ion-exchange methods and rapid Ab−antigen binding rates given the excellent mass-transfer characteristics of the PLMs.
Adsorption/thermal desorption with multisorbent air-sampling cartridges was developed for the determination of 87 method analytes including halogenated alkanes, halogenated alkenes, ethers, alcohols, nitriles, esters, ketones, aromatics, a disulfide, and a furan. The volatilities of the compounds ranged from that of dichlorofluoromethane (CFC12) to that of 1,2,3- trichlorobenzene. The eight most volatile compounds were determined using a 1.5-L air sample and a sample cartridge containing 50 mg of Carbotrap B and 280 mg of Carboxen 1000; the remaining 79 compounds were determined using a 5-L air sample and a cartridge containing 180 mg of Carbotrap B and 70 mg of Carboxen 1000. Analysis and detection were by gas chromatography/mass spectrometry. The minimum detectable level (MDL) concentration values ranged from 0.01 parts per billion by volume (ppbv) for chlorobenzene to 0.4 ppbv for bromomethane; most of the MDL values were in the range 0.02-0.06 ppbv. No breakthrough was detected with the prescribed sample volumes. Analyte stability on the cartridges was very good. Excellent recoveries were obtained with independent check standards. Travel spike recoveries ranged from 90 to 110% for 72 of the 87 compounds. The recoveries were less than 70% for bromomethane and chloroethene and for a few compounds such as methyl acetate that are subject to losses by hydrolysis; the lowest travel spike recovery was obtained for bromomethane (62%). Blank values for all compounds were either below detection or very low. Ambient atmospheric sampling was conducted in New Jersey from April to December, 1997. Three sites characterized by low, moderate, and high densities of urbanization/traffic were sampled. The median detected concentrations of the compounds were either similar at all three sites (as with the chlorofluorocarbon compounds) or increased with the density of urbanization/traffic (as with dichloromethane, MTBE, benzene, and toluene). For toluene, the median detected concentrations were 0.23, 0.42, and 0.70 ppbv at the three sites. Analytical precision was measured using duplicate sampling. As expected, the precision deteriorated with decreasing concentration. At concentrations greater than 0.2 ppbv, most duplicates differed by less than 20%; below the MDL values, the differences between the duplicates were larger, but they were still typically less than 40%.
Phenylurea and triazine herbicides, including some metabolites, were isolated from water and soil extracts by solid-phase extraction using a layered system of two extraction disks, a method called double-disk solid-phase extraction. The first disk consisted of strong anion exchange (SAX) of 10-μm styrene divinylbenzene (SDB) particles embedded in Teflon, and the second disk was a C 18 disk of 10-μm particles also embedded in Teflon. A volume of 500 mL of water or aqueous soil extract is passed through the layered system with the SAX disk first. The purpose of the SAX disk is to remove the humic and fulvic acids from the water or aqueous soil extract by ion exchange through their carboxyl groups. Even during methanol elution of herbicides, the humic substances remain bound to the SAX disk with >85% retention. Elution with methanol results in more than 90% recovery of the herbicides from the layered extraction disks. Removal of the humic and fulvic acids results in greater sensitivity for diode array detection quantitation (0.05 μg/L for herbicides) by substantially reducing the absorbance of the humic peak on the LC chromatogram. The herbicides adsorb to the SAX disk either through hydrogen bonding to the anion-exchange sites or by hydrophobic interaction with the SDB surface of the anion-exchange disk. The method was tested for the analysis of natural water samples from the Mississippi Embayment, a cotton-growing area of the southeastern United States.
Widely used isotope ratio mass spectrometers have limited capabilities to measure metabolites, drugs, or small polyatomic ions without the loss of structural isotopic information. A new approach has recently been introduced that uses electrospray ionization Orbitrap to measure multidimensional isotope signatures of intact polar compounds. Using nitrate as a model compound, this study aims to establish performance metrics for comparisons with conventional IRMS at the natural abundance level. We present a framework on how to convert isotopolog intensities to δ values that are commonly used in the isotope geochemistry community. The quantification of seven nitrate isotopologs provides multiple pathways for obtaining the primary N and O δ values including non-mass-dependent O isotope variations, as well as opportunities to explore nonrandom isotopic distributions (i.e., clumping effects) within molecular nitrate. Using automation and the adaptation of measurement principles that are specific to isotope ratio analysis, nitrate δ15NAIR, δ18OVSMOW, and δ17OVSMOW were measured with a long-term precision of 0.4‰ or better for isotopic reference materials and purified nitrate from environmental samples. In addition, we demonstrate promising results for unpurified environmental samples in liquid form. With these new developments, this study connects the two largely disparate mass spectrometry fields of bioanalytical MS and isotope ratio MS, thus providing a route to measure new isotopic signatures in diverse organic and inorganic solutes.
Statistical methods for the analysis and design of experiments using digital PCR (dPCR) have received only limited attention and have been misused in many instances. To address this issue and to provide a more general approach to the analysis of dPCR data, we describe a class of statistical models for the analysis and design of experiments that require quantification of nucleic acids. These models are mathematically equivalent to generalized linear models of binomial responses that include a complementary, log–log link function and an offset that is dependent on the dPCR partition volume. These models are both versatile and easy to fit using conventional statistical software. Covariates can be used to specify different sources of variation in nucleic acid concentration, and a model’s parameters can be used to quantify the effects of these covariates. For purposes of illustration, we analyzed dPCR data from different types of experiments, including serial dilution, evaluation of copy number variation, and quantification of gene expression. We also showed how these models can be used to help design dPCR experiments, as in selection of sample sizes needed to achieve desired levels of precision in estimates of nucleic acid concentration or to detect differences in concentration among treatments with prescribed levels of statistical power.
An international project developed, quality-tested, and determined isotope−δ values of 19 new organic reference materials (RMs) for hydrogen, carbon, and nitrogen stable isotope-ratio measurements, in addition to analyzing pre-existing RMs NBS 22 (oil), IAEA-CH-7 (polyethylene foil), and IAEA-600 (caffeine). These new RMs enable users to normalize measurements of samples to isotope−δ scales. The RMs span a range of δ 2 H VSMOW-SLAP values from −210.8 to +397.0 mUr or ‰, for δ 13 C VPDB-LSVEC from −40.81 to +0.49 mUr and for δ 15 N Air from −5.21 to +61.53 mUr. Many of the new RMs are amenable to gas and liquid chromatography. The RMs include triads of isotopically contrasting caffeines, C 16 n -alkanes, n -C 20 -fatty acid methyl esters (FAMEs), glycines, and l -valines, together with polyethylene powder and string, one n -C 17 -FAME, a vacuum oil (NBS 22a) to replace NBS 22 oil, and a 2 H-enriched vacuum oil. A total of 11 laboratories from 7 countries used multiple analytical approaches and instrumentation for 2-point isotopic normalization against international primary measurement standards. The use of reference waters in silver tubes allowed direct normalization of δ 2 H values of organic materials against isotopic reference waters following the principle of identical treatment. Bayesian statistical analysis yielded the mean values reported here. New RMs are numbered from USGS61 through USGS78, in addition to NBS 22a. Because of exchangeable hydrogen, amino acid RMs currently are recommended only for carbon- and nitrogen-isotope measurements. Some amino acids contain 13 C and carbon-bound organic 2 H-enrichments at different molecular sites to provide RMs for potential site-specific isotopic analysis in future studies.
The zirconium-alizarin method has been modified to facilitate the convenient and accurate determination of small amounts of fluoride in a large number of water samples. Sulfuric acid is used to acidify the samples to reduce the interference of sulfate. The pH is accurately controlled to give the most sensitive comparisons. Most natural waters can be analyzed by the modified procedure without resorting to correction curves. The fluoride content of waters containing less than 500 parts per million of sulfate, 500 parts per million of bicarbonate, and 1000 parts per million of chloride may be determined within a limit of about 0.1 part per million when a 100-ml. sample is used.
No abstract available.
No abstract available.
A survey of atrazine and its metabolites in Kansas ground water indicated that ground-water quality was impacted by stream-aquifer interaction between rivers in the Kansas River basin and their adjacent alluvial aquifers. Atrazine was detected in 19 of the 78 samples. The most common metabolite, deethylatrazine, was detected in 25 samples, 18 of which also had atrazine. The deethylatrazine/atrazine ratio (DAR) of < 1.0 indicates rapid movement of agricultural chemicals to ground water. In this study, 12 of 18 samples had DAR values < 1.0, suggesting rapid recharge to the aquifers. Hydroxyatrazine is seldom detected in ground water. In this study hydroxyatrazine was detected primarily in wells sited in alluvium of rivers. These rivers contain atrazine in varying concentrations. Results of the study suggest that stream-aquifer interaction is a process contributing to the presence of both atrazine and its metabolites in ground water in these areas.A survey of atrazine and its metabolites in Kansas ground water indicated that ground water quality was impacted by stream-aquifer interaction between rivers in the Kansas River basin and their adjacent alluvial aquifers. Atrazine was detected in 19 of the 78 samples. The most common metabolite, deethylatrazine, was detected in 25 samples, 18 of which also had atrazine. The deethylatrazine/attrazine ratio (DAR) of < 1.0 indicates rapid movement of agricultural chemicals to ground water. In this study, 12 of 18 samples had DAR values < 1.0, suggesting rapid recharge to the aquifers. Hydroxyatrazine is seldom detected in ground water. In this study hydroxyatrazine was detected primarily in wells sited in alluvium of rivers. These rivers contain atrazine in varying concentration. Results of the study suggest that stream-aquifer interaction is a process contributing to the presence of both attrazine and its metabolites in ground water in these areas.