Search USGS⌕ Search

USGS · tm5B13

Determination of per- and polyfluoroalkyl substances in water by direct injection of matrix-modified centrifuge supernatant and liquid chromatography/tandem mass spectrometry with isotope dilution

Abstract

A direct-injection liquid chromatography/tandem mass spectrometry method was developed to determine 34 per- and polyfluoroalkyl substances (PFAS), including selected branched isomers, in centrifuge supernatant of matrix-modified (amended with approximately 50 percent methanol) water samples. The method has been validated in reagent water, surface water, groundwater, and wastewater effluent. Other water types (for example, drinking water, untreated wastewater, and landfill leachate) have been analyzed by the method but not systematically validated. Recovery of isotope-dilution standards, added to each sample, may be used to assess method performance in nonvalidated matrices on a sample-by-sample basis. Using this method, PFAS concentrations were determined in the range of 2–2,000 nanograms per liter in water samples. This range can be extended by diluting concentrated samples. At circumneutral pH, most compounds are present in the environment in their ionized form, and data are reported as such (for example, perfluorooctanoic acid is referred to as “perfluorooctanoate” [PFOA], perfluorooctane sulfonic acid is referred to as “perfluorooctane sulfonate” [PFOS]). Sample preparation procedures were designed without the use of filtration and with minimum sample handling steps to mitigate procedural losses of target compounds due to sorption to surfaces. Further, isotope-dilution quantification allowed for the correction of bias that may result from procedural losses, matrix-induced signal suppression or enhancement, and other factors. Validation experiments to characterize bias and variability, method detection level, and holding time were done in four distinct water matrices—reagent water, surface water, treated wastewater effluent, and groundwater—at multiple concentration levels. Mean PFAS recoveries met data quality objectives of bias and variability studies in all four validation matrices except for two compounds with low and variable recovery in the reagent water matrix only. Isotope-dilution standards, treated as surrogate compounds, were analyzed in more than 1,500 customer-submitted environmental samples with aggregate recovery of 102.5±6.5 percent (mean±standard deviation). Maximum holding times for all target compounds in the four validation matrices were 28 days for refrigerated samples and 90 days for frozen samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

James L. Gray, Leslie K. Kanagy, Christopher J. Kanagy, Cyrissa A. Anderson. 2025-07-09. Determination of per- and polyfluoroalkyl substances in water by direct injection of matrix-modified centrifuge supernatant and liquid chromatography/tandem mass spectrometry with isotope dilution. https://doi.org/10.3133/tm5b13

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related USGS reports

dMODELS, a MATLAB software package for modeling crustal deformation near volcanic centers and active faults using Global Navigation Satellite System data—User guide

dMODELS is a MATLAB software package that implements the most common analytical models used to interpret deformation measurements near faults and active volcanic centers. This manual focuses on inversion of deformation data from the Global Navigation Satellite System (GNSS). The included case studies emphasize the GNSS inversion component of the software. Source models include pressurized spherical, spheroidal, and horizontal sill (penny-crack) magma reservoirs in a homogeneous, elastic, isotropic, flat half-space. A topography correction is available for the spherical source. Dikes and faults are described following the mathematical notation for the rectangular dislocations in a homogeneous, elastic, flat half-space. Equations have been reviewed for typographical errors present in the original literature and verified against finite-element method numerical models. GNSS data from the 2006 eruption at Augustine Volcano, Alaska; the 1998–2000 unrest at Taal Volcano, Philippines; and the 2009 earthquake in L’Aquila, Italy, are used to demonstrate the application of the software package.

Techniques and Methods↗

Aspergillosis (Avian) case definition for wildlife

Diagnostic laboratories receive carcasses and samples for diagnostic evaluation and pathogen/toxin detection. Case definitions bring clarity and consistency to the evaluation process. Their use within and between organizations allows more uniform reporting of diseases and etiologic agents. The intent of a case definition is to provide scientifically based criteria for determining: (a) if an individual carcass has a specific disease and degree of confidence in that diagnosis and (b) if there is evidence of a pathogen or toxin in a carcass or sample (for example, swab, tissue sample, skin scraping, blood/serum sample, environmental sample, or other). This case definition is specific to aspergillosis and applies to all avian species.

Techniques and Methods↗

Field sampling guidelines for developing and verifying satellite remote sensing chlorophyll a concentration and fluorescence models in inland waters

Harmful algal blooms are increasing in frequency in inland waters across the United States, resulting in a need to monitor phytoplankton bloom events to track ecosystem health and productivity. Remote sensing of chlorophyll a values offers a cost-effective and powerful method for early detection and characterization of bloom events and serves as an overall indicator of water quality and trophic state, with regular, repeated sampling of landscape-wide, high spatial resolution measurements. Field measurements are necessary for developing and verifying chlorophyll a retrieval models. For model verification, chlorophyll a concentration or fluorescence and light attenuation measurements are needed; for model development, turbidity and colored dissolved organic matter concentration measurements are additionally needed; and for model development and verification, radiometric measurements, taxonomic identification of phytoplankton, inherent optical properties, and cyanotoxin concentration are further measurements that can provide context. This report outlines detailed methods and priority considerations for collecting high-quality field data in inland waters (defined as rivers, lakes, reservoirs, estuaries, streams, and wetlands). The described methods include best practices for collecting and preparing discretely collected water samples and for calibration, maintenance, and quality assurance and quality control of field sensors. Whereas the priorities will vary between applications, some general guidelines are to collect field samples (1) as close in time to a satellite overpass as possible, (2) from representative areas of the waterbody to capture the range of spatial variability, and (3) near the surface to match remote sensing reflectance data.

Techniques and Methods↗