Abstract

Mechanistic models capable of simulating hydrodynamics and water temperature in rivers and reservoirs are valuable tools for investigating thermal conditions and their relation to dam operations and streamflow in river basins where upstream water storage and management decisions have an important influence on river reaches with threatened fish populations. In particular, models allow managers to investigate how new, untried operations or hypothetical structures might influence streamflow and temperature conditions downstream. CE-QUAL-W2 is a two-dimensional (laterally averaged) hydrodynamic water-quality model that has previously been used to investigate the downstream effects of dam operations and other anthropogenic influences on stream temperature in the Willamette River Basin in northwestern Oregon, a region with two populations of fish species designated as threatened under the Endangered Species Act. By linking CE-QUAL-W2 river models to models of upstream, large Willamette Valley Project dams and reservoirs, these models can be used to investigate how dam operations at individual dams can influence streamflow and thermal conditions in downstream river reaches as an integrated system. Integrated model simulations that include the large dams and reservoirs linked to downstream river reaches can help managers develop a better understanding of tradeoffs associated with potential retrofits or operational changes across the multipurpose dams in the Willamette Valley Project, the effect of dam management on downstream tributaries and the Willamette River, and the resulting potential effect on threatened fish populations and habitat conditions. River models capable of simulating river corridors downstream from U.S. Army Corps of Engineers dams were previously updated and integrated to simulate conditions that occurred from March through October of 2011 (a cool and wet year), 2015 (a hot and dry year), and 2016 (a moderately hot and dry year) using CE-QUAL-W2 version 4.2. These river models encompass the following: Coast Fork Willamette and Middle Fork Willamette Rivers, the Row River, and Fall Creek downstream from Cottage Grove, Dexter, Dorena, and Fall Creek Dams, respectively; South Fork McKenzie River downstream from Cougar Dam; McKenzie River downstream from its confluence with the South Fork McKenzie River; South Santiam River downstream from Foster Dam; North Santiam River downstream from Big Cliff Dam; and Willamette River from its start at the confluence of the Middle Fork Willamette and Coast Fork Willamette Rivers to Willamette Falls (river mile 26.0; near West Linn, Oregon). This report documents model modifications, boundary condition data sources or estimation methods, and goodness-of-fit statistics for six CE-QUAL-W2 reservoir models and one river model upstream from the existing river models. These models simulate (1) Hills Creek Lake; (2) Lookout Point Lake and Dexter Reservoir on the Middle Fork Willamette River; (3) the Middle Fork Willamette River reach between Hills Creek Dam upstream and Lookout Point Lake downstream; (4) Cougar Reservoir on the South Fork McKenzie River; (5) Green Peter Lake on the Middle Santiam River and Foster Lake on the South Santiam River; and (6) Detroit Lake and (7) Big Cliff Reservoir on the North Santiam River. These CE-QUAL-W2 models were built by a variety of researchers to simulate a range of conditions in past years; this report documents their upgrade to U.S. Geological Survey (USGS) edition 7 of version 4.2 of CE-QUAL-W2 and updates each model to simulate conditions from January through December of 2011, 2015, and 2016. Also included in this report is an explanation of modifications to the CE-QUAL-W2 source code that constitute USGS edition 7 of CE-QUAL-W2 version 4.2. Each of the models described in this report can be run in isolation or linked to downstream models as a “system model” to simulate conditions in tributaries and (or) in the Willamette Valley Project as a whole. As part of the model updates described in this report, some model parameters were adjusted to improve stability or decrease model error, and boundary conditions including meteorological, hydrologic, and temperature inputs were developed and updated for model years 2011, 2015, and 2016, as necessary. In some cases, the data sources used to drive previous model versions were no longer available, which required the development and checking of new data sources or estimation techniques. Goodness-of-fit statistics for outflow from the dams and in simulated river reaches generally show a good model fit, with the models simulating subdaily water temperatures at most comparable locations with a mean absolute error of generally less than 1 degree Celsius (°C) and a reasonably low bias. Model simulation of the thermal vertical profiles in each reservoir also produced an overall mean absolute error of generally less than 1 °C for all 3 years, with the exception of the Hills Creek Lake Model and the Cougar Reservoir Model in years when the reservoirs did not fill (2015 and 2016). Both of these models have known calibration issues and tend to be sensitive to the choice of certain structural parameters in the model. Overall, the calibration process was focused on obtaining model settings that led to realistic water temperature predictions in all 3 years (2011, 2015, and 2016) without over-calibrating specifically to any single year. A complete investigation of model error for these reservoir submodels was beyond the scope of this investigation but could be undertaken in the future if better model performance for these two reservoirs is desired.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 42.79157283626091° to 46.04098363545978° latitude; -123.63148629596873° to -121.15566880710551° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Laurel E. Stratton Garvin, Norman L. Buccola, Stewart A. Rounds. 2023-09-05. Updates to CE-QUAL-W2 models for select U.S. Army Corps of Engineers reservoirs in the Willamette Valley Project and an inter-reservoir reach of the Middle Fork Willamette River, northwestern Oregon. https://doi.org/10.3133/sir20235085

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗