Search USGS⌕ Search

USGS · sir20215091

Evaluation of hydrologic simulation models for fields with subsurface drainage to mitigated wetlands in Barnes, Dickey, and Sargent Counties, North Dakota

Abstract

Proper identification of wetlands, along with a better understanding of the hydrology of mitigated wetlands, is needed to assist with conservation efforts aimed at maintaining the productivity and ecological function (wetland mitigation) of agricultural lands. The U.S. Geological Survey, in cooperation with the U.S. Department of Agriculture Natural Resources Conservation Service, completed a study to evaluate two models for simulating hydrologic conditions in fields with subsurface drainage to mitigated wetlands at several sites in North Dakota. These two models were evaluated as possible tools for water resource managers to use for designing wetland mitigation projects in the area in the future. The Soil-Plant-Atmosphere-Water (SPAW) model simulates the daily hydrologic water budgets of agricultural landscapes by two linked routines, one for farm fields (field hydrology) and one for impoundments such as wetlands and ponds (pond model). The DRAINMOD model was used in conjunction with the SPAW model because although the SPAW model can be used to simulate the hydrology of small drainage basins containing wetlands, the SPAW model does not contain routines to simulate drainage, either subsurface drainage or surface (drainage ditches), that can directly affect the wetland hydrology. The wetlands in the study areas in this report are all downstream from and adjacent to drained agricultural fields. SPAW and DRAINMOD models were developed and calibrated at three study areas (study areas B, D, and S) to evaluate how the models simulated field-scale hydrologic characteristics and the water balance in wetlands from January 1, 2003, through December 31, 2018. The SPAW model developed for study area B included five modeled fields in the field hydrology portion of SPAW that contributed inflow to one wetland simulated in the pond model portion of SPAW. Simulated wetland water depths were most similar to water depths measured at site BWET1, with an absolute mean error of 0.10 foot and a root mean square error of 0.14 foot. Site BWET2 had slightly larger errors, with an absolute mean error of 0.22 foot and a root mean square error of 0.28 foot. Simulated water depths were similar to the pattern of measured water depths at BWET1 and BWET2 from about mid-April 2018 through about mid-September 2018, but overpredicted water depths in the fall from about mid-September 2018 through about mid-October 2018. The SPAW model developed for study area D included six modeled fields in the field hydrology portion of SPAW that contributed inflow to five wetlands connected in series in the pond model portion of SPAW. Simulated water depths compared relatively well to water depths in the five wetlands, with the absolute mean error ranging from 0.17 foot (DWET1) to 0.39 foot (DWET2), and the root mean square error ranging from 0.28 foot (DWET1) to 0.56 foot (DWET5). The SPAW model developed for study area S included one modeled field in the field hydrology portion of SPAW that contributed inflow to one wetland in the pond model portion of SPAW. Among the SPAW models developed for the three study areas, the model for study area S had the best comparison between simulated and measured water depths, with an absolute mean error of 0.06 foot and a root mean square error of 0.10 foot. DRAINMOD models were developed and calibrated at the three study areas and provided inflow from subsurface drainage discharge to the SPAW models for simulating water levels in wetlands in the study areas. The calibrated DRAINMOD model for study area B showed the variability of hydrologic processes in the modeled field throughout the wide range of hydrologic conditions from January 1, 2003, through December 31, 2018. In general, the discharge through the modeled subsurface drainage system was in the spring and early summer (April through June) most years, with little to no discharge later in the year. Although the subsurface drainage system in study area D was the most complex among the three study areas and was simplified into a uniform system within DRAINMOD, simulated water table depths at study area D correlated better to measured water table depths compared to results from the model applications at the other two study areas. Simulated water table depths had an absolute mean error of 0.30 foot and root mean square error of 0.37 foot at site DGW1 and an absolute mean error of 0.29 foot and a root mean square error of 0.34 foot at site DGW2. Although the subsurface drainage system in study area S was the simplest and the modeled field was the smallest among the three study areas, simulated water table depths at study area S did not correlate as well to measured water table depths compared to results from the model applications at the other two study areas. The SPAW and DRAINMOD model applications at the three study areas in southeast North Dakota adequately simulated the hydrologic processes for fields with subsurface drainage that are connected to adjacent wetlands. However, more measured data would be needed to fully evaluate the models throughout the range of possible climatic conditions.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 45.9351° to 47.2412° latitude; -99.0073° to -97.231° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Joel M. Galloway, Wyatt S. Tatge, Spencer L. Wheeling. 2021-09-15. Evaluation of hydrologic simulation models for fields with subsurface drainage to mitigated wetlands in Barnes, Dickey, and Sargent Counties, North Dakota. https://doi.org/10.3133/sir20215091

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗