Search USGS⌕ Search

USGS · sir20215022

Estimating stream temperature in the Willamette River Basin, northwestern Oregon—A regression-based approach

Abstract

The alteration of thermal regimes, including increased temperatures and shifts in seasonality, is a key challenge to the health and survival of federally protected cold-water salmonids in streams of the Willamette River basin in northwestern Oregon. To better support threatened fish species, the U.S. Army Corps of Engineers (USACE) and other water managers seek to improve the thermal regime in the Willamette River and key tributaries downstream of USACE dams by utilizing strategically timed flow releases from USACE dams. To inform flow management decisions, regression relations were developed for 12 Willamette River basin locations below USACE dams relating stream temperature with streamflow and air temperature utilizing publicly available datasets spanning 2000–18. The resulting relations provide simple tools to investigate stream temperature responses to changes in streamflow and climatic conditions in the Willamette River system. Regression relations on the Willamette River and key tributaries show that, at locations sufficiently distant from the direct temperature influence of upstream dam releases, air temperature and streamflow are reasonable proxies to predict the 7-day average of the daily mean (7dADMean) and 7-day average of the daily maximum (7dADMax) water temperature with errors generally ≤1 degrees Celsius (°C). To account for seasonal variations in the relation between air temperature, streamflow, and stream temperature, a transition-smoothed, seasonal regression approach was used. Stream temperature is inversely correlated with streamflow in all seasons except “winter” (January–March), when it is relatively independent. Stream temperature is positively correlated with air temperature in all seasons, but the slope decreases at very low or very high air temperatures. Generally, fit is best for seasonal models “winter” (January–March), “spring” (April–May), “summer” (June–August), and “early autumn” (September–October). Error in “autumn” (November–December) is larger, probably due to variation in the onset timing of winter storms. Simulated results from a climatological analysis of predicted stream temperature suggest that, excluding extremes and accounting for some seasonal variability, the 7dADMean and 7dADMax stream temperature sensitivity to air temperature and streamflow varies by location on the river. To investigate the potential range of stream temperature variability based on historical air temperature and streamflow conditions, stream temperature predictions were calculated using synthetic time series comprised of daily temperature values representing the 0.10, 0.33, 0.50, 0.67, and 0.90 quantile of air temperature and streamflow from 1954 (the year meaningful streamflow augmentation began) to 2018. Results show that from a “very hot” (0.90 quantile) and “very dry” (0.10 quantile) year to a “very cool” (0.10 quantile) and “very wet” (0.90; all quantiles from 1954 to 2018) year, the stream temperature sensitivity to air temperature and streamflow is about 3 °C at Harrisburg (river mile 161.0) and increases to about 5 °C at Keizer (river mile 82.2). While the number of days exceeding regulatory criteria are fewer in cooler, wetter years than in warmer, dryer years, the models suggest that the Willamette River will likely continue to exceed the State of Oregon maximum water-temperature criterion of 18 °C for sustained periods from late spring to early autumn and that the flow management practices evaluated in this study, while effective at influencing stream temperature, likely cannot prevent many or all such exceedances. As modeled for 2018, a representative very hot year with normal to below-normal streamflow, stream temperature sensitivity to changes in streamflow of ±100 to ±1000 cubic feet per second produced mean monthly temperature changes from 0.0 to 1.4 °C at Keizer, Albany, and Harrisburg during summer. For a specified change in flow, temperature sensitivity is greater at upstream locations where streamflow is less than that at downstream locations because the change in streamflow is a greater percentage of total streamflow at upstream locations. Similarly, temperature response to a set change in flow is greater in the summer and early autumn low-flow season than in spring when flows are higher. The regression models developed in this study thus indicate that flow management is likely to have a greater effect on stream temperature at upstream locations (such as Harrisburg or Albany) and during the low-flow season than at downstream locations (such as Keizer) or during periods of higher streamflow.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 43.54854811091286° to 45.99696161820381° latitude; -123.64013671874999° to -122.18994140624999° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Laurel E. Stratton Garvin, Stewart A. Rounds, Norman L. Buccola. 2022-05-12. Estimating stream temperature in the Willamette River Basin, northwestern Oregon—A regression-based approach. https://doi.org/10.3133/sir20215022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗