Search USGSSearch

USGS · sir20165125

Performance evaluation testing of wells in the gradient control system at a federally operated Confined Disposal Facility using single well aquifer tests, East Chicago, Indiana

Abstract

The U.S. Geological Survey (USGS) performed tests to evaluate the hydrologic connection between the open interval of the well and the surrounding Calumet aquifer in response to fouling of extraction well pumps onsite. Two rounds of air slug testing were performed on seven monitoring wells and step drawdown and subsequent recovery tests on three extraction wells on a U.S. Army Corps of Engineers Confined Disposal Facility (CDF) in East Chicago, Indiana. The wells were tested in 2014 and again in 2015. The extraction and monitoring wells are part of the gradient control system that establishes an inward gradient around the perimeter of the facility. The testing established a set of protocols that site personnel can use to evaluate onsite well integrity and develop a maintenance procedure to evaluate future well performance. The results of the slug test analysis data indicate that the hydraulic connection of the well screen to the surrounding aquifer material in monitoring wells on the CDF and the reliability of hydraulic conductivity estimates of the surrounding geologic media could be increased by implementing well development maintenance. Repeated air slug tests showed increasing hydraulic conductivity until, in the case of the monitoring wells located outside of the groundwater cutoff wall (MW–4B, MW–11B, MW–14B), the difference in hydraulic conductivity from test to test decreased, indicating the results were approaching the optimal hydraulic connection between the aquifer and the well screen. Hydraulic conductivity values derived from successive tests in monitoring well D40, approximately 0.25 mile south of the CDF, were substantially higher than those derived from wells on the CDF property. Also, values did not vary from test to test like those measured in monitoring wells located on the CDF property, which indicated that a process may be affecting the connectivity of the wells on the CDF property to the Calumet aquifer. Derived hydraulic conductivity values from the initial air slug test during the 2015 testing period for MW–11A and MW–14A are an order of magnitude less than those derived from the final test during the 2014 testing period indicating the development of a low conductivity skin between the final test of the 2014 testing period and the beginning of the 2015 testing period that created a decrease in the connection of the monitoring well screen to the surrounding aquifer material. Repeated step drawdown and recovery testing of the extraction wells tested during this study provided results that indicate a slight increase in the development of a skin and a decrease in the connectivity of the extraction wells with the Calumet aquifer. Hydraulic conductivity values obtained from the test results were relatively similar in EW–4B and EW–14A but were substantially lower for EW–11C. This difference may be due to the presence of finer grained silt deposits in the area surrounding well nest 11. Skin factors calculated during the step drawdown and recovery analysis were lowest in EW–11C and relatively similar in EW–4B and EW–14A. Calculated skin factors increased slightly in the analysis of data collected in 2015 from that collected in 2014. Comparisons of the specific-capacity values calculated from well development data collected following extraction well installation to those calculated during the single well aquifer tests at EW–4B, EW–14A and EW–11C indicate that the productivity of extraction wells on the CDF property has diminished since 2008. Values calculated for monitoring wells MW–4A, MW–11A, and MW–14A were used to evaluate the decrease in air slug derived hydraulic conductivity for monitoring wells within the groundwater cutoff wall between testing in 2014 and 2015. Results from testing by this study indicate that implementation of an air slug testing regimen of the monitoring wells that control the gradient control system at the CDF throughout the course of a year may help sustain the connectivity between the monitoring wells and the surrounding aquifer and provide data to evaluate the need for different types of well development approaches to address chemical or biological fouling issues. Repeated step drawdown and recovery testing of the extraction wells tested during this study provided results that indicate a slight increase in the development of a skin and a decrease in the connectivity of the extraction wells with the Calumet aquifer. Implementation of a specific capacity testing regimen can provide data to record and track well condition through time for individual extraction wells. Results from aquifer testing by this study indicate that specific capacity test results, when paired with recovery testing, provide useful data to measure the development of any low conductivity wellbore skin through the skin factors derived for the individual extraction wells. An initial annual schedule of specific capacity and recovery tests would provide sufficient data to identify substantial short-term changes in the operating condition of the extraction wells.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 41.583333° to 41.716667° latitude; -87.533333° to -87.366667° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

David C. Lampe, Michael D. Unthank. 2016-12-08. Performance evaluation testing of wells in the gradient control system at a federally operated Confined Disposal Facility using single well aquifer tests, East Chicago, Indiana. https://doi.org/10.3133/sir20165125

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Monitoring recreation on federally managed lands and waters—Aspects of visitor use

Federally managed public lands and waters receive around 1 billion recreational visits each year. Data on these visitors can aid in guiding policy decisions, managing resources effectively, and communicating the economic contributions of lands and waters. This report explores the methods used by agencies to collect data on aspects of recreational visitor use to Federal lands and waters (apart from visitation numbers, which are the focus of a companion publication). Aspects of recreational visitor use include visitor demographics, recreational activity participation, visitor satisfaction, visitor attitudes and experiences, trip characteristics, and economic contributions. We review practices used to understand aspects of visitor use across seven Federal agencies, revealing similarities such as the use of visitor intercept surveys and coverage of similar topic areas, and differences in how survey programs are operationalized and how specific questions on visitor surveys are worded. We also evaluate emerging technologies, such as geolocated social media and mobile device location data, for their potential to aid in understanding aspects of visitor use. This report concludes with potential opportunities to enhance data collection and coordination, ensuring cost-effective data collection and informed decision making.

Scientific Investigations Report

Evaluation of best management practices at an edge-of-field site in the Eagle Creek watershed, Ohio, 2012–20

In 2010, the U.S. Geological Survey worked in partnership with the Great Lakes Restoration Initiative and the Natural Resources Conservation Service to identify farm fields in priority watersheds—watersheds critically important to Great Lake health. Intensive best management practices were implemented in five States to test the efficacy of best management practices, also referred to as agricultural conservation practices, to reduce sediment and nutrient runoff on agricultural fields. These fields were chosen as representatives of the priority watersheds because their farming practices and geographical conditions were common among farms in those watersheds. A farm site located near Findlay, Ohio, in the Eagle Creek watershed used two conservation practices, cover crop (Natural Resources Conservation Service practice standard 340) and variable rate technology (VRT; Natural Resources Conservation Service practice standard 590), which represent common practices in the Maumee priority watershed. This study monitored surface runoff and subsurface tile runoff at the Eagle Creek watershed site. The effects of cover crop and VRT nutrient application on sediment and nutrient runoff were assessed from October 2012 to September 2020. Cover crops were applied in fall of 2016, 2017, and 2018, coinciding with VRT applications. The following parameters were analyzed as part of the study: runoff discharge; peak discharge; and concentrations and loads of total phosphorus, particulate phosphorus, dissolved reactive phosphorus, and suspended sediment. High peak runoff events disproportionally affected nutrient concentrations and loads in runoff. A threshold of the 85th percentile of the peak discharge was chosen to assess the effect of cover crop and VRT nutrient application on nutrient mitigation at each gage. Runoff events below the 85th percentile were considered small, and runoff events over the 85th percentile were considered large. Concentrations from collected water-quality samples were used for the analysis; estimated concentrations were excluded from the statistical evaluation. All surface runoff parameters during small runoff events, except surface runoff volume, were significantly lower in the period with cover crops and VRT implementation. Contrarily, subsurface runoff parameters during small events were not statistically different between the periods with and without cover crops and VRT implementation. Surface and subsurface parameters during large events were also not statistically different between the periods with and without cover crops and VRT implementation. These results indicate cover crops and VRT may improve water quality during small runoff events, but additional best management practices that mitigate large runoff events may lead to greater water-quality improvement given the contribution of large events to overall losses.

Ohio

Continuous monitoring and temporal variability of fluorescence of dissolved organic matter in karst groundwater of the Edwards aquifer, south-central Texas, 2019–24

Widespread urbanization on the Edwards aquifer recharge zone in south-central Texas has prompted the development of new approaches and tools for evaluating the current and future status of water quality in the San Antonio and Barton Springs segments of the Edwards aquifer. The U.S. Geological Survey, in cooperation with the San Antonio Water System and the City of Austin, applied continuous monitoring of fluorescence of dissolved organic matter (fDOM) to characterize the sources and transport of dissolved organic matter and associated constituents in the Edwards aquifer. Continuous fDOM time-series data were adjusted using empirically derived temperature, turbidity, and inner-filter-effect correction factors prior to analysis and interpretation. Fully corrected fDOM time-series data from the study sites were evaluated for short- and long-term temporal variability in fDOM in the context of the hydrologic and climatic conditions that occurred during the 5-year study period to understand vulnerability of the aquifer to potential contaminants in recharge. Study results indicate that fDOM is an effective proxy for dissolved organic carbon that, in turn, is indicative of the influx of recent surface water and associated contaminants, and thus, aquifer vulnerability to those contaminants. Although other continuously monitored water-quality parameters provide insights into changes in water quality in response to varying hydrologic conditions, the quantitative relation between fDOM and dissolved organic carbon directly indicates the timing and magnitude of pulses of organic constituents derived from the land surface, whereas other water-quality parameters do not.

Texas