Search USGS⌕ Search

USGS · sir20155117

A conceptual framework and monitoring strategy for movement of saltwater in the coastal plain aquifer system of Virginia

Abstract

A conceptual framework synthesizes previous studies to provide an understanding of conditions, processes, and relations of saltwater to groundwater withdrawal in the Virginia Coastal Plain aquifer system. A strategy for monitoring saltwater movement is based on spatial relations between the saltwater-transition zone and 612 groundwater-production wells that were regulated during 2013 by the Virginia Department of Environmental Quality. The vertical position and lateral distance and direction of the bottom of each production well’s screened interval was calculated relative to previously published groundwater chloride iso-concentration surfaces. Spatial analysis identified 81 production wells completed in the Yorktown-Eastover and Potomac aquifers that are positioned in closest proximity to the 250-milligrams-per-liter chloride surface, and from which chloride concentrations are most likely to increase above the U.S. Environmental Protection Agency’s 250-milligrams-per-liter secondary maximum-contaminant level. Observation wells are specified to distinguish vertical upconing from lateral intrusion among individual production wells. To monitor upconing, an observation well is to be collocated with each production well and completed at about the altitude of the 250-milligrams-per-liter chloride iso-concentration surface. To monitor lateral intrusion, a potential location of an observation well is projected from the bottom of each production well’s screened interval, in the lateral direction to the underlying chloride surface to a distance of 1 mile. Monitoring potential withdrawal-induced movement of saltwater in the Virginia Coastal Plain aquifer system is needed to detect increases in chloride concentration before groundwater-production wells become contaminated. An investigation was undertaken during 2014 by the U.S. Geological Survey in cooperation with the Virginia Department of Environmental Quality, to provide a sound scientific understanding of saltwater movement and guidance to implement a monitoring program. Previous studies have theorized that the saltwater originated primarily from seawater repeatedly emplaced within aquifer sediments during the past about 65 million years. Subsequent flushing by fresh groundwater has been impeded across sediments filling the Chesapeake Bay impact crater. The resulting saltwater-transition zone has been mapped to exhibit a warped and steeply mounded dome shape about centered on the impact crater, and flanked by a nearly level and shallow plateau shape to the southeast. Groundwater chloride concentrations have historically fluctuated during periods of weeks to months, probably as a result of localized vertical upconing beneath individual production wells. Lateral intrusion takes several decades or more to horizontally displace groundwater across distances of about 1 mile toward production wells. Upconing is relatively immediate, but reversible, whereas lateral intrusion under the regionally landward hydraulic gradient may slowly, but permanently reposition the saltwater-transition zone. Upconing coupled with lateral intrusion is theorized to produce composite chloride-concentration trends that vary widely over time in response to changing water demands, and evolve dynamically from hydraulic interactions among multiple neighboring production wells. Some aspects of observation-well construction and sampling are of particular importance to monitoring saltwater movement in the Virginia Coastal Plain aquifer system. Observation wells should feature screened intervals generally of no more than 10 feet that isolate distinct parts of the aquifer, and be thoroughly developed for removal of drilling fluid and introduced water. Presample purging should fully displace stratified saltwater in the well casing upward to the pump. Stable flow should be maintained as field parameters are measured and sample containers are filled with filtered water isolated from the atmosphere and unaffected by surface temperature. Groundwater samples from both upconing and lateral-intrusion observation wells should initially be collected four times per year when wells are newly established, but can be more optimally timed with withdrawal once responses in chloride concentrations can be reliably predicted. Concentrations of major ions (1) determine the dominant chemical composition of groundwater at each well, (2) establish the relative position of the well within the saltwater-transition zone, and (3) provide data quality control by calculation of sample charge balance. For these reasons, samples initially collected for the first year from newly established observation wells should be analyzed for calcium, magnesium, sodium, and potassium cations and chloride, bicarbonate, carbonate, sulfate, fluoride, and bromide anions. Inflection-point titration for alkalinity should be completed in the field. Analysis of chloride and field parameters may be adequate on a long-term basis once the dominant chemical composition at each well is established. Specific conductance may also provide a surrogate for chloride concentration depending on regulatory policy. The saltwater-movement monitoring strategy is limited and constrained. Relative monitoring needs among groundwater-production wells, and construction of observation wells, depend on the accuracy of previously mapped groundwater chloride iso-concentration surfaces. Production wells in similar proximity to saltwater can differ in aquifer hydraulic conductivity, rates of withdrawal, and screened-interval lengths. Only production wells making withdrawals reported to the Virginia Department of Environmental Quality have been accounted for; undocumented production wells can result in spurious changes in groundwater chloride concentration. Upconing observation wells should be as close as possible to corresponding production wells, so long as production wells are not damaged by borehole deviation. Projected locations of some lateral-intrusion observation wells may be precluded and require adjustment. Depths of upconing and lateral-intrusion observation wells may also require adjustment to be within the same aquifer as their corresponding production wells. Existing unused wells can be adapted as observation wells if differences from specified locations and construction are kept to a minimum and are accounted for. Where multiple production wells are in proximity, a modified monitoring approach may be needed to determine their net effect on changes in chloride concentration, and may require more than one lateral-intrusion observation well depending on the vertical positions of production-well screened intervals.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 36.51405119943165° to 38.436379603° latitude; -78.24462890625° to -75.3387451171875° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

E. Randolph Mcfarland. 2015-09-04. A conceptual framework and monitoring strategy for movement of saltwater in the coastal plain aquifer system of Virginia. https://doi.org/10.3133/sir20155117

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗