In 2010, the U.S. Geological Survey, in cooperation with the San Antonio Water System, began a study to assess the brackish-water movement within the Edwards aquifer (more specifically the potential for brackish-water encroachment into wells near the interface between the freshwater and brackish-water transition zones, referred to in this report as the transition-zone interface) and effects on spring discharge at Comal and San Marcos Springs under drought conditions using a numerical model. The quantitative targets of this study are to predict the effects of higher-than-average groundwater withdrawals from wells and drought-of-record rainfall conditions of 1950–56 on (1) dissolved-solids concentration changes at production wells near the transition-zone interface, (2) total spring discharge at Comal and San Marcos Springs, and (3) the groundwater head (head) at Bexar County index well J-17. The predictions of interest, and the parameters implemented into the model, were evaluated to quantify their uncertainty so the results of the predictions could be presented in terms of a 95-percent credible interval. The model area covers the San Antonio and Barton Springs segments of the Edwards aquifer; the history-matching effort was focused on the San Antonio segment. A previously developed diffuse-flow model of the Edwards aquifer, which forms the basis for the model in this assessment, is primarily based on a conceptualization in which flow in the aquifer is predominately through a network of numerous small fractures and openings. Primary updates to this model include an extension of the active area downdip, a conversion to an 8-layer SEAWAT variable-density flow and transport model to simulate dissolved-solids concentration effects on water density, history matching to 1999–2009 conditions, and parameter estimation in a highly parameterized context using automated methods in PEST (a model-independent Parameter ESTimation code). In addition to the best-fit parameter values derived from history matching, the uncertainty of model parameters was also estimated by using linear uncertainty analysis. Comparison of “prior” (before history matching) and “posterior” (after history matching) variances of parameters indicate that the information within the observation dataset used for history matching informs many parameters. The concentration threshold parameters were well-informed by the observation dataset as their posterior distributions were much narrower than their prior distributions. The transition-zone scaling parameters of hydraulic conductivity, effective porosity, and specific storage were all informed by the observation dataset, as evidenced by the difference between the prior and posterior variances. Saline-zone scaling parameters, alternatively, were not informed by the observation dataset for effective porosity and specific storage. Resulting posterior drier-month, wetter-month, and annual recharge multiplier parameter variances are important to understanding how well recharge is estimated and implemented within the model. The shifts of the posterior distributions left and right indicate that there were zones where less or more water was needed in the model. The widths of the distributions were not decreased substantially, indicating that many of the best-fit recharge parameters are not statistically different from the initial values specified in the history-matching effort. Recharge from rainfall is the driving force behind groundwater flow and heads in the aquifer; therefore, an increase in understanding of this process would benefit model development by potentially decreasing the uncertainty of this parameter. The history-matching effort was most helpful in informing the parameters in the model that control discharge at springs, namely, the spring orifice (drain) altitude and drain conductance parameters for each spring. The uncertainty assessment of the predictive model (a hypothetical recurrence of 1950–56 drought conditions and higher-than-average groundwater withdrawals from wells) provided insights into the potential effects of these conditions on dissolved-solids concentration changes at production wells near the transition-zone interface, discharges at Comal and San Marcos Springs, and heads at Bexar County index well J-17. Results at the 25 production wells near the transition-zone interface indicate that the uncertainty of model input parameters based on expert knowledge yielded an upper bound of the 95-percent credible interval of dissolved-solids concentrations that exceeds the secondary drinking water standards of 1,000 milligrams per liter (mg/L) of the Texas Commission on Environmental Quality (TCEQ) for many wells. However, the history-matching process provided key information to inform prediction-sensitive model parameters and therefore, contributed to a substantial decrease of the upper bound of the 95-percent credible interval to below the secondary drinking water standards. Reductions in dissolved-solids concentration changes were on the order of 400 mg/L to 1,300 mg/L. The reduction in uncertainty in regards to this prediction implies that this prediction of dissolved-solids concentration change can be made with some certainty using this current model and that those parameters that control this prediction are informed by the observation dataset. Even though predictive uncertainty was reduced for this prediction, dissolved-solids concentration changes were still greater than zero, indicating a minimal increase in concentration at these 25 production wells during the 7-year simulation period is likely. However, this minimal concentration increase indicates a small potential for movement of the brackish-water transition zone near these wells during the 7-year simulation period of drought-ofrecord (1950–56) rainfall conditions with higher-than-average groundwater withdrawals by wells. Predictive results of total spring discharge during the 7-year period, as well as head predictions at Bexar County index well J-17, were much different than the dissolved-solids concentration change results at the production wells. These upper bounds are an order of magnitude larger than the actual prediction which implies that (1) the predictions of total spring discharge at Comal and San Marcos Springs and head at Bexar County index well J-17 made with this model are not reliable, and (2) parameters that control these predictions are not informed well by the observation dataset during historymatching, even though the history-matching process yielded parameters to reproduce spring discharges and heads at these locations during the history-matching period. Furthermore, because spring discharges at these two springs and heads at Bexar County index well J-17 represent more of a cumulative effect of upstream conditions over a larger distance (and longer time), many more parameters (with their own uncertainties) are potentially controlling these predictions than the prediction of dissolved-solids concentration change at the prediction wells, and therefore contributing to a large posterior uncertainty.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 28.36240173523821° to 30.562260950499414° latitude; -101.1181640625° to -97.37182617187499° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Linzy K. Brakefield, Jeremy T. White, Natalie A. Houston, Jonathan V. Thomas. 2015. Updated numerical model with uncertainty assessment of 1950-56 drought conditions on brackish-water movement within the Edwards aquifer, San Antonio, Texas. https://doi.org/10.3133/sir20155081

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Baseline water-quality inventory and summary for the Paterson Great Falls National Historical Park, New Jersey

The Paterson Great Falls National Historical Park (PAGR), established in 2011 in the City of Paterson, New Jersey, contains many cultural, historical, and natural resources. Because of the PAGR’s young age and limited resources, a long record of natural resource data is not available for use to guide future park management and planning decisions. A detailed natural resource inventory was identified as an immediate need in the “Foundation Document—Paterson Great Falls National Historical Park,” given the history of extensive industrial activity throughout the PAGR and the Passaic River Basin. The U.S. Geological Survey, in cooperation with the National Park Service and the Urban Waters Federal Partnership for the Lower Passaic River, inventoried water-quality monitoring efforts and compiled historical water-quality data from secondary data sources to define baseline conditions in the PAGR and the surrounding study area. This report documents the methods used to harmonize water-quality data aggregated from multiple sources for the PAGR study area. Procedures implemented during data harmonization include compiling data from multiple sources, assessing the dataset for completeness, addressing metadata concerns, and creating a consistent and quality-assured dataset for future analysis. The harmonized dataset contains 14 aggregated surface-water sites, 1,103 individual sampling days, and 32,000 water-quality records throughout the period of record defined for this study (1952–2021). Summary statistics and comparison to water-quality criteria are provided for focus parameters that can support PAGR management, including field properties, suspended material, total dissolved solids, specific conductance, chloride, sulfate, Escherichia coli, nutrients, contaminants of concern related to fish consumption advisories, and litter and floatable debris. A spatial data gap was identified for the recreational area near the base of the Great Falls and immediately downstream from a known combined sewer overflow discharge location. Analytic data gaps were identified for continuous streamflow and water-quality parameters, floatable debris characterization, and harmful algal blooms identification. Continuous collection of contaminants of concern was identified as a temporal data gap, as these parameters were not consistently collected within the study area. The water-quality data synthesis and summary presented in this report can assist PAGR staff in understanding the complex baseline water resources within the study area and can serve as a baseline to design future water-quality monitoring efforts and evaluate changes in water quality over time. The harmonized dataset, as well as future New Jersey Department of Environmental Protection and New Jersey Harbor Discharge Group monitoring data and assessments, can also be used to examine the status and trends in surface-water quality, support compliance with the Clean Water Act (33 U.S.C. 1251 et seq.), and further investigate changes to park water resources that can affect ecological and human health.

New Jersey↗

Slip tendency and dilation tendency of Quaternary faults in the Great Basin region, Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming

This report presents the results of slip tendency and dilation tendency analysis of Quaternary faults in the Great Basin region, in the states of Arizona, California, Idaho, Nevada, Oregon, Utah, and Wyoming. This effort was undertaken as part of two studies: the U.S. Department of Energy Geothermal Technologies Office-funded Innovative Geothermal Exploration through Novel Investigations of Undiscovered Systems (INGENIOUS) project, which is a multidisciplinary, multi-institution effort to develop new methodologies and best practices to accelerate the discovery of new, commercially viable hydrothermal resources; and the U.S. Geological Survey Geothermal Resources Investigations Project. The goal of this work is to identify faults and fault segments that are appropriately oriented to be stress-loaded for slip or to dilate under the ambient stress conditions. Both conditions may make such faults more likely to host permeability and fluid flow relative to other faults in the region. Slip tendency and dilation tendency were calculated for all fault segments in the study area from the U.S. Geological Survey Quaternary Fault and Fold Database. Results demonstrate that faults with high slip tendency and dilation tendency are common in the Great Basin region. The areas containing many high slip tendency and dilation tendency fault segments are associated with high strain rates. These areas also host a relatively high proportion of the known hydrothermal systems. This indicates that faults with high slip tendency and dilation tendency in areas with high strain-rate are potentially most prospective for hosting hydrothermal systems. The database published in coordination with this report contains the slip tendency and dilation tendency results data, including the fault geometry and stress data used to calculate these quantities, for both the Great Basin study area and the smaller INGENIOUS study area.

Arizona, California, Idaho, Nevada, Oregon, Utah, ↗

A spatial analysis of the groundwater emergence flood hazard in Long Island, New York, and coastal areas surrounding Long Island Sound in New York, Connecticut, and Rhode Island

Long Island, New York, and nearby coastal areas surrounding Long Island Sound are densely populated and, like other coastal areas, are susceptible to flooding from several potential sources, including stormwater from precipitation events, tidal flooding and storm surge, and groundwater emergence flooding. Groundwater emergence fooding refers to the intersection of a rising water table with land surface or critical infrastructure. Many studies of flood drivers either neglect or only briefly discuss how shallow groundwater conditions may contribute to or exacerbate flood conditions. As a part of a comprehensive study of compound flood hazards in the coastal areas of Long Island and Long Island Sound, a spatial analysis was completed by the U.S. Geological Survey, in cooperation with the Environmental Protection Agency’s Long Island Sound Partnership, formerly called the Long Island Sound Study, using available regional datasets to characterize the potential hazard for groundwater emergence flooding. The approximately 3,100 square mile study area was subdivided into 11,407 grid cells that were 900 meters by 900 meters (approximately 3,000 feet by 3,000 feet), for the purpose of integrating the spatial datasets to calculate and map the groundwater emergence flood hazard. The depth to the water table, hydrologic soil groups, and National Land Cover Database were harmonized to the common grid. A groundwater emergence flood hazard score was calculated for each grid cell for current average conditions following a set of rules accounting for the depth to the water table and the percentage of area within each cell with slow infiltrating soils. A scenario with a higher sea-level position was also calculated for the Long Island part of the study area. The calculated groundwater emergence flood hazard score was reviewed in conjunction with the National Land Cover Database to identify developed areas and associated infrastructure that may be at risk of potential groundwater emergence flooding. Study results indicate that the groundwater emergence flood hazard is highest in coastal areas and near surface water where the water table is close to ground surface. Inland areas away from surface waterbodies are not likely to be exposed to groundwater emergence flooding. For Long Island, in the scenario with higher sea-level position, a greater groundwater emergence flood hazard is calculated for some locations closer to the coast and where land is submerged. Away from the coast and surface-water drainage, the groundwater emergence flood hazard is similar between the current average sea-level condition and the higher sea-level position scenario.

Connecticut, New York, Rhode Island↗