USGS · ofr7687
Notes on a broad-band variant of the NCER seismic data multiplex system for use with field tape recorders
Abstract
Tests of the standard NCER multiplex system recorded and played back on both the Bell and Howell 3700B (about 0.1% tape speed variation) and on the Sony TC-126 cassette recorder (about 1% tape speed variation) showed that subtractive compensation employing a reference frequency multiplexed on the data track was remarkably effective in reducing tape-speed-variation-induced noise 1 and, hence, in increasing the dynamic range of the record/playback system. Further tests suggested that the 0 to 30 Hz bandwidth of the standard system (8 data channels) might be increased substantially, at the 'price' of reducing the number of data channels to 3 or 4, without serious loss of dynamic range if subtractive compensation could be implemented effectively with the broader-band system.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Jerry P. Eaton. 1976. Notes on a broad-band variant of the NCER seismic data multiplex system for use with field tape recorders. https://doi.org/10.3133/ofr7687
Cite the original work for its findings. Save a collection to share your selection of sources.