Search USGSSearch

USGS · 70273779

Prioritizing resource protection and understanding potential susceptibility of springs to surficial changes in a low-temperature geothermal system

Abstract

Geothermal systems are vulnerable to changes in water budget and composition, requiring science-based management. This study uses a dataset of spring water temperatures, time series of groundwater residence time tracers (tritium and carbon-14), and stable isotopes of water to understand geothermal flow in a low-temperature geothermal system in north west Colorado, United States (Steamboat Springs). The geothermal system is bisected by the Yampa River, necessitating a stream mass balance approach to quantify total discharge. Time series analysis of water temperature data provides a ranked list of features more susceptible to surficial changes, which is corroborated using time series of tritium which indicate spatially distinct patterns of mixing between modern and pre-modern groundwater. All springs contain a portion of pre-modern groundwater that is thousands to tens of thousands of years old, a period coinciding with melting of extensive Pleistocene glaciers that was likely one of the recharge sources to the geothermal system. Stream mass balance indicates that greater than 80% of the total geothermal discharge is derived from diffuse or small springs, highlighting the extensive nature of the geothermal outflow zone and the association with local geologic structures. This study provides baseline data to support management of the Steamboat Springs geothermal system and indicates the utility of these approaches in developing science-based geothermal management.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 40.45° to 40.567° latitude; -106.87961681380281° to -106.68° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

BibTeXRIS

Connor P. Newman, Jeffrey D. Pepin. 2026-01-24. Prioritizing resource protection and understanding potential susceptibility of springs to surficial changes in a low-temperature geothermal system. https://doi.org/10.1016/j.geothermics.2026.103615

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related USGS reports

Enhanced geothermal systems electric-resource assessment for the Great Basin, southwestern United States

The U.S. Geological Survey recently (2025) completed a provisional assessment of the geothermal-electric resources associated with high-temperature, low-permeability rock formations of the Great Basin, Southwestern United States. If sufficient technological advances to commercialize enhanced geothermal systems occur, then a current best provisional estimate for electric-power generation capacity of 135 gigawatts electric are available from the upper 6 kilometers of the Earth’s crust. This estimate is a potential substantial increase of the installed geothermal electricity-generating capacity from <1 to 10 percent of current total U.S. power production capacity.

California, Idaho, Nevada, Oregon, Utah

Long-term trends in microseismicity during operational shut-ins at the Coso Geothermal Field, California

Pausing injection and production can lead to induced seismicity in a variety of settings, with some of the largest events occurring during these so-called shut-ins. In geothermal fields, shut-ins are periodically conducted for maintenance on wells and surface infrastructure, thereby offering recurring means of estimating stress changes in the subsurface that lead to increased seismicity rates. Here, we examine daily production and microseismicity data from the Coso Geothermal Field (CGF) in California between 1996 and 2010 to investigate the repetitive trends of operational shut-in microseismicity. Using 24 local seismic stations, we first analyze spatial and temporal trends of over 60,000 earthquakes with magnitudes between -0.4 to 3.8. We find that the northern region exhibits no significant seismicity changes during shut-ins, whereas the rest of the field experiences induced seismicity during almost every shut-in with an increasing intensity towards the southern and eastern portions of the field, highlighting local differences in stress within the CGF. Additionally, we cluster the seismicity using waveform cross-correlation, revealing several earthquake clusters primarily occurring during shut-in periods. These observations suggest that certain fracture and fault sections respond quicker to changes in pore pressure and poroelastic stresses within the geothermal system, possibly highlighting main fluid pathways.

California

Hydrogeologic framework and considerations for drilling and grouting of closed-loop geothermal bores in the Erie-Ontario Lowlands and Allegheny Plateau of New York State

The hydrogeologic framework at closed-loop geothermal sites in the Erie-Ontario Lowlands and Allegheny Plateau of central and western New York is the result of the complex interaction of bedrock geology, glacial geology, and groundwater hydrology, and the occurrence of petroleum and gas. Considerations for closed-loop geothermal bore installation include the thickness and character of glacial deposits, bedrock solubility and depth to competent rock, karst development, the distribution of highly permeable zones and their hydraulic heads, and the presence of saline water, gas, and oil. The hydrogeology of the Erie-Ontario Lowlands and Allegheny Plateau poses challenges to closed-loop geothermal bore drilling and casing; managing drill cuttings, discharge water, and gas; and grouting. The potential to encounter severe challenges typically increases with bore depth. This report highlights hydrogeologic considerations for closed-loop geothermal bore installation in New York’s Erie-Ontario Lowlands and Allegheny Plateau to help guide the efficient and safe development of geothermal resources in the regions.

New York