Search USGSSearch

USGS · 70258435

Using a time-of-travel sampling approach to quantify per- and polyfluoroalkyl substances (PFAS) stream loading and source inputs in a mixed-source, urban catchment

Abstract

Understanding per- and polyfluoroalkyl substances (PFAS) mass distribution in surface and groundwater systems can support source prioritization, load reduction, and water management. Thirteen sites within an urban catchment were sampled utilizing a time-of-travel sampling approach to minimize the influence of subdaily fluctuations in mass from PFAS point sources and to quantify PFAS and ancillary chemical loads from various PFAS sources. A larger increase in perfluoroalkyl sulfonate (PFSA) loads (8 to 11 μg/s, up to 618%) than in perfluoroalkyl carboxylate (PFCA) loads (no change to 3.4 μg/s, up to 122%) was observed at sites below tributaries influenced by military bases with known groundwater discharge. Point discharges from two sewage treatment plants (STPs) resulted in increases in PFCA and PFSA loads that were similar (6 and 10 μg/s respectively) below the first STP and greater for PFCA compared to PFSA loads (23 and 13 μg/s respectively) below the second STP. Overall, percent increases in total PFAS load ranged from 20 to 277% for military base inputs and 44 to 77% for STP inputs. A focus catchment that represents only 14% (76.9 km 2 ) of the drainage area at the most downstream site (544 km 2 ) accounted for about 70% of PFSA and 40% of PFCA loads observed at the most downstream site. Results show that by using a time-of-travel sampling approach in mixed, urban settings with several PFAS sources, it is possible to quantify stream loads from individual PFAS sources, thereby improving source attribution and providing actionable data for water-resource managers.

Explore related subjects

Keep this discovery

BibTeXRIS

Emily E. Woodward, Lisa A. Senior, Jacob Fleck, Larry B. Barber, Angela Hansen, Joseph W. Duris. 2024-09-16. Using a time-of-travel sampling approach to quantify per- and polyfluoroalkyl substances (PFAS) stream loading and source inputs in a mixed-source, urban catchment. https://doi.org/10.1021/acsestwater.4c00288

Cite the original work for its findings. Save a collection to share your selection of sources.

Discover connections

Connections use source metadata and explicit phrase matches, not verified experimental comparisons.

KEEP EXPLORING

Related USGS reports

Detection of viral, bacterial, and protozoan pathogens and microbial source tracking markers in paired large- and small-volume water samples

When sampling for waterborne microbes, researchers may need to diverge from recommended sample volumes due to logistical constraints, novel targets, or challenging matrices, with little guidance about the potential impact on results. In field studies, we measured bacteria, viruses, and protozoa (15 quantitative polymerase chain reaction assays) in paired large- and small-volume samples to evaluate method performance and relevant factors. Concordance between methods was low. Large-volume ultrafiltration yielded more detections than small-volume sampling, especially for pathogens in groundwater. Greater microbial concentrations were associated with more frequent detections in small-volume samples and greater concordance between paired samples. Large-volume samples appeared to be more susceptible to diminished sensitivity from complex sample matrices. In laboratory studies, recovery of microbes was poorer for large- than small-volume methods, although large-volume methods more reliably detected low-concentration targets. Large-volume samples were less stable than small-volume samples during storage. Overall, large-volume sampling was superior for detecting pathogens but may underestimate concentrations; small-volume sampling was more prone to false negatives but was adequate when concentrations were relatively high, like we observed for microbial source tracking in surface waters.

Wisconsin

Microplastics undergo fragmentation during pressurized membrane filtration

Low-micrometer microplastics (<10 μm) have been detected in drinking water, driving growing interest in using pressure-driven membrane filtration to remove these particles and ensure drinking water safety. However, little attention is paid to the fate of microplastics concentrated in the filtration byproduct. In this study, using well-defined polystyrene (PS) and poly(methyl methacrylate) microspheres as model particles, we observed microplastic fragmentation during nanofiltration and the subsequent release of smaller fragments. After operating for 3 h at 20 bar, 67.9 ± 8.0% of the PS spheres in the concentrate, based on particles counted in selected fields of view, were transformed into fractured particles. The characteristic Raman band signals of microplastics were significantly weakened after fragmentation, leading to detection challenges. To address this, a data processing algorithm was developed to identify PS fragments as small as 1 μm. Preliminary statistical analysis reveals that within the tested pressure range, operation time has a stronger influence on fragmentation than pressure magnitude alone and that fragmentation is further governed by the intrinsic mechanical properties of the tested model polymers. This work provides direct evidence that pressure-driven membrane processes induce microplastic fragmentation and highlights the environmental risks associated with the discharge of fragmented microplastics into the concentrate.

Environmental Science & Technology Letters

Examining the compositional selectivity of hydrocarbon oxidation products using liquid–liquid extraction and solid-phase extraction techniques

The effect of extraction methods on detecting hydrocarbon oxidation products (HOPs) in groundwater remains unclear. HOPs are polar, water-soluble byproducts of petroleum biodegradation. Our previous work showed that liquid–liquid extraction (LLE), a method commonly used in regulatory monitoring, has a significantly lower extraction efficiency for HOPs compared to solid-phase extraction (SPE). In this study, we evaluate the analytical limitations and compositional selectivity of LLE and SPE using groundwater samples from the Bemidji, MN, crude oil spill site. Optical properties were characterized using excitation–emission matrix spectroscopy (EEMs), and a three-component PARAFAC model was validated, showing consistent trends across both extracts and whole water samples. Ultrahigh-resolution mass spectrometry (UHR-MS) revealed that LLE selectively recovered aliphatic-like compounds but underrepresented more polar oxygenated HOPs. In contrast, SPE methods were more effective at isolating highly oxidized compound classes. These differences were consistent across a gradient of contamination. Overall, the LLE was less precise and less representative of polar HOPs, introducing bias in the characterization of HOPs. This study is the first to quantitatively demonstrate the compositional selectivity and analytical bias of LLE versus SPE for HOPs using combined EEM-PARAFAC and UHR-MS techniques, with implications for long-term monitoring and site assessment protocols.

Environmental Science and Technology