Search USGSSearch

USGS · 70211216

Cautions and suggestions for geochemical sampling in fractured rock

Abstract

Collecting water samples for geochemical analyses in open bedrock boreholes or in discrete intervals of boreholes intersected by multiple fractures is likely to yield ambiguous results for ground water chemistry because of the variability in the transmissivity, storativity, and hydraulic head of fractures intersecting the borehole. Interpreting chemical analyses of water samples collected in bedrock boreholes requires an understanding of the hydraulic conditions in the borehole under the ambient flow regime in the aquifer as well as during sampling. Pumping in open boreholes, regardless of the pumping rate and the location of the pump intake, first draws water from the borehole and then from fractures intersecting the borehole. The time at which the volumetric rate of water entering the borehole from fractures is approximately equal to the pumping rate can be identified by monitoring the logarithm of drawdown in the borehole as a function of the logarithm of time. Mixing of water entering the borehole from fractures with water in the borehole must be considered in estimating the time at which the pump discharge is representative of aquifer water. In boreholes intersected by multiple fractures, after the contribution from the borehole volume has diminished, the contribution of fractures to the pump discharge will be weighted according to their transmissivity, regardless of the location of the pump intake. This results in a flux‐averaged concentration in the pump discharge that is biased by the chemical signature of those fractures with the highest transmissivity. Under conditions where the hydraulic head of fractures varies over the length of the borehole, open boreholes will be subject to ambient flow in the water column in the borehole. In some instances, the magnitude of the ambient flow may be similar to the designated pumping rate for collecting water samples for geochemical analyses. Under such conditions, the contributions to the pump discharge from individual fractures will be a function not only of the transmissivity of the fractures, but also of the distribution of hydraulic head in fractures intersecting the borehole. To reduce or eliminate the deleterious effects of conducting geochemical sampling in open boreholes, a straddle‐packer apparatus that isolates a single fracture or a series of closely spaced fractures is recommended. It is also recommended that open boreholes be permanently outfitted with borehole packers or borehole liners in instances where maintaining the hydraulic and chemical stratification in the aquifer is of importance. In a field example, a comparison of results from sampling in an open borehole and in discrete intervals of the same borehole showed dramatic differences in the concentrations of chemical constituents in the water samples, even though chemical field parameters stabilized prior to both open borehole and discrete interval sampling.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Allen M. Shapiro. 2007-02-22. Cautions and suggestions for geochemical sampling in fractured rock. https://doi.org/10.1111/j.1745-6592.2002.tb00764.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

One Ranney well can make a difference: The impacts of a radial collector well on groundwater level and quality in the Cedar River alluvial aquifer

The City of Cedar Rapids, Iowa, depends on groundwater from the Cedar River alluvial aquifer for residential and industrial use. In 2020, the city completed an additional radial collector well, or Ranney well, and was concerned that pumping from the well at high rates may lower water level elevations in the aquifer, reduce yields from nearby production wells, and change the quality of produced water. During an operational test of the well's pumps, the U.S. Geological Survey and the city collected water level and water quality data to evaluate the effects of increased pumping rates on the aquifer and nearby production wells. Results indicated that a high rate of pumping from the new well caused sustained declines in water levels near the well and other nearby production wells, and, if maintained, the aquifer water level in the vicinity would continue to decline to levels observed during the 2012 drought. Aquifer specific conductance and temperature were altered and matched trends and values of the river, and river-to-well travel time was shortened from 7-17 days to about 3 days. Results may also provide insights to other municipal water resource managers when considering wellfield design, production expectations, and long-term management strategies for radial collector well production during drought, low streamflow, and times when high concentrations of nitrate-N or organic pesticide compounds in the river may limit production options.

Iowa

Accuracy of flowmeters measuring horizontal flow in fractured-rock simulators

Laboratory evaluations of flowmeter response to flow in fractured-rock simulators are needed to improve understanding of data collected in field settings. The ability of flowmeters to accurately measure the velocity and direction of water flowing between parallel plates was used as a surrogate for instrument response in fractured-rock aquifers. A colloidal borescope flowmeter and a heat-pulse flowmeter were deployed in a fractured rock simulator with 4-inch and 6-inch inner-diameter, uncased wells with 0.39- and 1.0-inch fracture apertures and groundwater velocities from 35 to 975 ft/d. The colloidal borescope measurements and applied velocities were positively correlated in all wells and apertures (the coefficient of determination [ r 2 ] = 0.61–0.89) and most accurately measured direction at higher velocities. The mean directional error in colloidal borescope measurements was less than 17° in 6-inch wells and 31° in the 4-inch wells at velocities between 92 and 958 ft/d. Heat-pulse flowmeter measurements were 0.001 to 0.004 times less than applied rates and may indicate that water was moving around rather than through the instrument's integrated packer. The mean directional error of heat-pulse flowmeter measurements were about 18 and 42° in the 0.39- and 1.0-inch fractures, respectively, for groundwater velocities within the manufacturer's suggested range of application (0.5–100 ft/d). Measurements made at vertical increments and fracture positions in the well using the colloidal borescope indicate that laminar flow occurs within the central 50% of the fracture but measurements above or below are likely affected by eddy currents.

Groundwater Monitoring & Remediation

1DTempPro V2: new features for inferring groundwater/surface-water exchange

A new version of the computer program 1DTempPro extends the original code to include new capabilities for (1) automated parameter estimation, (2) layer heterogeneity, and (3) time-varying specific discharge. The code serves as an interface to the U.S. Geological Survey model VS2DH and supports analysis of vertical one-dimensional temperature profiles under saturated flow conditions to assess groundwater/surface-water exchange and estimate hydraulic conductivity for cases where hydraulic head is known.

Groundwater Monitoring & Remediation