Search USGSSearch

USGS · 70209663

Relations among hydrocarbon reservoirs, epigenetic sulfidization, and rock magnetization; Examples from the South Texas coastal plain

Abstract

This paper focuses on the association between concentrations of iron disulfide (FeS 2 ) minerals in the shallow subsurface and underlying hydrocarbon accumulations. Such FeS 2 concentrations are the result of migration of either H 2 S or organic constituents from the underlying hydrocarbons. The H 2 S from reservoirs is produced inorganically from sulfate in the reservoir rocks at high temperature (>90 degrees C) and migrates to shallower beds to react inorganically with iron to form FeS 2 . Organic constituents from reservoirs, in contrast, provide nourishment for sulfate reducing bacteria in shallow relatively cool (<90 degrees C) beds. Sandstone in the Ray Point uranium district in Live Oak County, Texas contains abundant FeS 2 which formed both from deep-seated H 2 S and from H 2 S produced in the shallow subsurface by bacteria that utilized organic materials from depth. Deep petroleum reservoirs were physically connected to near-surface (<100 m) beds containing epigenetic FeS 2 by the Oakville fault. Epigenetic iron sulfide formation occurred in at least four episodes over at least five million years. Evidence from the Ray Point district and elsewhere in Texas illustrates that sulfidization reactions have destroyed magnetic iron-titanium oxide minerals in the vicinity of major growth faults, resulting in a systematic decrease in magnetic susceptibility and magnitude of remanent magnetization in the vicinity of such faults. Growth faults which tap hydrocarbon deposits may be detectable using aeromagnetic methods.

Explore related subjects

90° N90° S · 180° W ← longitude → 180° E
Source-reported bounding extent: 28.0595° to 28.7882° latitude; -98.3363° to -97.8084° longitude. This indicates report coverage, not an exact sampling location. View area on OpenStreetMap.

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Martin B. Goldhaber, Richard L. Reynolds. 1991. Relations among hydrocarbon reservoirs, epigenetic sulfidization, and rock magnetization; Examples from the South Texas coastal plain. https://doi.org/10.1190/1.1443092

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Cooperative joint inversion of magnetotelluric and microseismic data for imaging the Geysers geothermal field, California, USA

The Geysers geothermal field located in northern California, USA, is the world’s largest electricity-generating geothermal facility. To delineate the spatio-temporal distribution of reservoir steam and recharge water, we have collected microseismic and magnetotelluric (MT) data using a dense array of stations in 2021. The microseismic and MT data have been inverted together using a 3D cooperative joint inversion workflow. The joint inversion exploits a cross-gradient structural constraint because electrical conductivity structures observed in the geothermal field are strongly correlated with

California

Inversion of induced polarization-affected towed-transient electromagnetic data in a lateritic regolith geology: A case study from western Tanzania

For several decades, induced polarization (IP) effects on transient electromagnetic (TEM) responses have been observed. These effects can manifest as late-time negative transients or as rapidly decaying curves and are usually associated with highly polarizable bodies. If neglected, IP effects can lead to erroneous resistivity models. Recent work allows IP effects to be incorporated into the inversion of TEM data on a more routine basis. In a recent field survey in western Tanzania, strongly IP-affected TEM signals are observed using a towed-transient electromagnetic (tTEM) system. The survey have been carried out to locate drinking water resources in a weathered regolith setting. In these settings, an inversion of tTEM data using a resistivity-only forward model (i.e., IP neglected) cannot fit the data and severely limits the value of the TEM data for hydrogeologic interpretation. To account for IP effects, we have applied a modified version of the Cole-Cole model called the maximum phase angle (MPA) model to invert IP-affected tTEM data. The MPA model incorporates four inversion model parameters: resistivity ( ⁠ &#x3C1; "> ρ ), MPA ( ⁠ &#x3D5; max "> ϕ max ⁠ ), relaxation time ( ⁠ &#x3C4; "> τ ), and frequency exponent ( ⁠ c "> c ). The MPA model fits the data well and improves the reliability of the resistivity model. In much of the surveyed region, the inverted models using MPA display a three-layer system consisting of an upper resistive laterite layer of varying thickness and an intermediate polarizable conductive unit overlying more resistive weathered basement rocks. The conductive polarizable layer is interpreted as a chemically weathered saprolite separating the surficial and deeper aquifers. Overall, tTEM inversion results provide a local understanding of groundwater systems, especially in such regions with very limited subsurface knowledge.

Kaguruka, Kitagata

Evidence-based guidelines for protective actions and earthquake early warning systems

Earthquake early warning systems (EEW) are becoming increasingly available or in development throughout the world. With public alerting in Mexico, Japan, Taiwan, and parts of the United States, it is important to provide evidence-based recommendations for protective action so people can protect themselves when they receive an alert. Best-practice warning communication research suggests that providing a protective action will increase the efficacy of the message. However, given the diversity of earthquakes and building types, as well as social and cultural contexts where these systems exist, the question is: what is the best protective action to recommend? The answer lies in maximizing life-saving protective actions during an earthquake event requires both contextually relevant messaging and widespread public education about appropriate protective actions under a range of conditions. By researching previous earthquake injury literature, examining current best practices and public education campaigns, key protective actions may be determined and used to increase the life-saving potential of earthquake early warning systems.

Geophysics