Search USGSSearch

USGS · 70125640

Seismic Station Installation Orientation Errors at ANSS and IRIS/USGS Stations

Abstract

Many seismological studies depend on the published orientations of sensitive axes of seismic instruments relative to north (e.g., Li et al., 2011). For example, studies of the anisotropic structure of the Earth’s mantle through SKS‐splitting measurements (Long et al., 2009), constraints on core–mantle electromagnetic coupling from torsional normal‐mode measurements (Dumberry and Mound, 2008), and models of three‐dimensional (3D) velocity variations from surface waves (Ekström et al., 1997) rely on accurate sensor orientation. Unfortunately, numerous results indicate that this critical parameter is often subject to significant error (Laske, 1995; Laske and Masters, 1996; Yoshizawa et al., 1999; Schulte‐Pelkum et al., 2001; Larson and Ekström, 2002). For the Advanced National Seismic System (ANSS; ANSS Technical Integration Committee, 2002), the Global Seismographic Network (GSN; Butler et al., 2004), and many other networks, sensor orientation is typically determined by a field engineer during installation. Successful emplacement of a seismic instrument requires identifying true north, transferring a reference line, and measuring the orientation of the instrument relative to the reference line. Such an exercise is simple in theory, but there are many complications in practice. There are four commonly used methods for determining true north at the ANSS and GSN stations operated by the USGS Albuquerque Seismological Laboratory (ASL), including gyroscopic, astronomical, Global Positioning System (GPS), and magnetic field techniques. A particular method is selected based on site conditions (above ground, below ground, availability of astronomical observations, and so on) and in the case of gyroscopic methods, export restrictions. Once a north line has been determined, it must be translated to the sensor location. For installations in mines or deep vaults, this step can include tracking angles through the one or more turns in the access tunnel leading to the vault (e.g., GSN station WCI in Wyandotte Cave, Indiana). Finally, the third source of error comes from the ability of field engineers to orient the sensor relative to the reference line. In order to quantify bounds on the errors in each step in the orientation process, we conducted a series of tests at the ASL using twelve GSN and ANSS field engineers. The results from this exercise allow us to estimate upper bounds on the precision of our ability to orient instruments, as well as identify the sources of error in the procedures. We are also able to identify systematic bias of various true‐north‐finding methods relative to one another. Although we are unable to estimate the absolute accuracy of our orientation measurements due to our inability to identify true north without some error, the agreement between independent methods for finding true north provides confidence in the different approaches, assuming no systematic bias. Finally, our study neglects orientation errors that are beyond the control of the field engineer during a station visit. These additional errors can arise from deviations in the sensitive axes of the instruments relative to the case markings, processing errors (Holcomb, 2002) when comparing horizontal orientations relative to other sensors (e.g., borehole installations), and deviations of the sensitive axes of instruments from true orthogonality (e.g., instruments with separate modules such as the Streckeisen STS‐1).

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Adam T. Ringler, Charles R. Hutt, K. Persfield, Lind S. Gee. 2013-10-24. Seismic Station Installation Orientation Errors at ANSS and IRIS/USGS Stations. https://doi.org/10.1785/0220130072

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Digitizer Suite: The Albuquerque Seismological Laboratory Digitizer Testing Suite

Laboratory testing of digitizers and seismometers helps ensure that prior to deployment the instrumentation can produce high quality data and is operating within specifications. In this work we detail the software package called: the Albuquerque Seismological Laboratory (ASL) Digitizer Test Suite. This Java software package provides several algorithms to verify various performance parameters of digitizers commonly used for recording analog seismic instruments. The goal of these tests is not to be exhaustive, but to identify common failures that could compromise the integrity of seismic data being recorded on the digitizer. For example, Sandia National Laboratories (e.g., Slad and Merchant, 2018) routinely do comprehensive testing of digitizers for various monitoring missions. While these tests reports are valuable for comprehensively characterizing a recording system, it would be resource intensive to conduct such tests on every seismic recorder used in a network. We focus on tests that include ways to estimate the sensitivity, timing, self-noise, and clip-level of the digitizer, as well as the fidelity of the signal being recorded. The software is publicly available and provides a way for the community to verify the integrity of a digitizer using a minimum amount of outside equipment.

Seismological Research Letters

The digital archivist: Automating legacy macroseismic data processing using large language models

Macroseismic data are a key resource to investigate shaking and damage from preinstrumental and early instrumental eras. However, data are often stored as inconsistently formatted reports describing observed shaking and damage, making manually parsing and interpreting accounts labor‐intensive. We introduce a novel workflow using Google’s Gemini 2.5 Pro large language model (LLM) to automate the extraction and structuring of macroseismic observations from summary reports. We apply this workflow to the 22 March 1957 M 5.3 Daly City, California, earthquake as a case study. We used Gemini to extract addresses, originally assigned modified Mercalli intensity values, and descriptions from each report. To address coordinate precision limits, addresses were geocoded via Google’s Geocoding application programming interface. This workflow yielded over 2300 geocoded intensity reports for the Daly City earthquake. We use the geocoded accounts, with the original report intensity assignments, to develop a shaking intensity map that in some respects rivals modern Did You Feel It? Maps. We also extract and present data for the 9 February 1971 M L 6.7 Sylmar, California, earthquake. Our results demonstrate the potential of LLMs for reliably extracting and analyzing large, unstructured macroseismic datasets. LLMs offer a scalable solution for rapidly digitizing macroseismic archives, enabling their broader use to constrain ground‐motion models in modern seismic hazard analysis and to improve our understanding of site effects in urban areas. The concepts explored here may also be applied to the handling of other legacy seismological and earth science data.

Seismological Research Letters