Carbon dioxide stripping in aquaculture -- part II: development of gas transfer models

Abstract

The basic mass transfer equation for gases such as oxygen and carbon dioxide can be derived from integration of the driving force equation. Because of the physical characteristics of the gas transfer processes, slightly different models are used for aerators tested under the non steady-state procedures, than for packed columns, or weirs. It is suggested that the standard condition for carbon dioxide should be 20 °C, 1 atm, CCO 2 =20 mg/kg, and XCO 2 =0.000285. The selection of the standard condition for carbon dioxide based on a fixed mole fraction ensures that standardized carbon dioxide transfer rates will be comparable even though the value of C* CO 2 in the atmosphere is increasing with time. The computation of mass transfer for carbon dioxide is complicated by the impact of water depth and gas phase enrichment on the saturation concentration within the unit, although the importance of either factor depends strongly on the specific type of aerator. For some types of aerators, the most accurate gas phase model remains to be determined for carbon dioxide. The assumption that carbon dioxide can be treated as a non-reactive gas in packed columns may apply for cold acidic waters but not for warm alkaline waters.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

John Colt, Barnaby Watten, Tim Pfeiffer. 2012. Carbon dioxide stripping in aquaculture -- part II: development of gas transfer models. https://doi.org/10.1016/j.aquaeng.2011.12.002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Investigating the influence of nitrate nitrogen on post-smolt Atlantic salmon Salmo salar reproductive physiology in water recirculation aquaculture systems

A major issue affecting land-based, closed containment Atlantic salmon Salmo salar growout production in water recirculation aquaculture systems (RAS) is precocious male maturation, which can negatively impact factors such as feed conversion, fillet yield, and product quality. Along with other water quality parameters, elevated nitrate nitrogen (NO 3 -N) has been shown to influence the reproductive development and endogenous sex steroid production in a number of aquatic animal species, including Atlantic salmon. We sought to determine whether elevated NO 3 -N in RAS can influence early maturation in post-smolt Atlantic salmon in an 8-month trial in replicated freshwater RAS. Post-smolt Atlantic salmon (102 ± 1 g) were stocked into six RAS, with three RAS randomly selected for dosing with high NO 3 -N (99 ± 1 mg/L) and three RAS set for low NO 3 -N (10 ± 0 mg/L). At 2-, 4-, 6-, and 8-months post-stocking, 5 fish were randomly sampled from each RAS, gonadosomatic index(GSI) data were collected, and plasma was sampled for 11-ketotestosterone (11-KT) quantification. At 4- and 8-months post-stocking, samples of culture tank and spring water (used as “makeup” or replacement water) were collected and tested for a suite of 42 hormonally active compounds using liquid chromatography/mass spectrometry , as well as for estrogenicity using the bioluminescent yeast estrogen screen (BLYES) reporter system. Finally, at 8-months post-stocking 8–9 salmon were sampled from each RAS for blood gas and chemistry analyses, and multiple organ tissues were sampled for histopathology evaluation. Overall, sexually mature males were highly prevalent in both NO 3 -N treatment groups by study’s end, and there did not appear to be an effect of NO 3 -N on male maturation prevalence based on grilse identification, GSI, and 11-KT results, indicating that other culture parameters likely instigated early maturation. No important differences were noted between treatment groups for whole blood gas and chemistry parameters, and no significant tissue changes were noted on histopathology. No hormones, hormone conjugates, or mycotoxins were detected in any water samples; phytoestrogens were generally detected at low levels but were unrelated to NO 3 -N treatment. Finally, low-level estrogenicity was detected in RAS water, but a NO 3 -N treatment effect could not be determined. The major findings of this study are i) the NO 3 -N treatments did not appear to be related to the observed male maturation, and ii) the majority of hormonally active compounds were not detectable in RAS water.

Aquacultural Engineering

Performance and application of a fluidized bed limestone reactor designed for control of alkalinity, hardness and pH at the Warm Springs Regional Fisheries Center

Springs serving the Warm Springs Regional Fisheries Center, Warm Springs, Georgia, have pH, alkalinity, and hardness levels thatlie under the range required for successful fish propagation while free CO 2 is well above allowable targets. We evaluate a pretreatment process that exploits limestone’s (CaCO 3 ) ability to react away hydrogen ions (H + ) and carbon dioxide (CO 2 ) while increasing alkalinity (HCO 3 − ) and calcium (Ca2+) concentrations, i.e. CaCO 3 + H + ↔ HCO 3 − + Ca 2+ CaCO 3 + CO 2 + H 2 O ↔ Ca 2+ + 2HCO 3 − Limestone sand was tested in both pilot and full scale fluidized bed reactors (CycloBio®). We first established the bed expansion characteristics of three commercial limestone products then evaluated the effect of hydraulic flux and bed height on dissolution rate of a single selected product (Type A16 × 120). Pilot scale testing at 18C showed limestone dissolution rates were relatively insensitive to flux over the range 1.51–3.03 m 3 /min/m 2 but were sensitive (P < 0.001; R 2 = 0.881) to changes in bed height (BH, cm) over the range 83–165 cm following the relation: (Alkalinity, mg/L) = 123.51 − (3788.76 (BH)). Differences between filtered and non-filtered alkalinity were small(P > 0.05) demonstrating that limestone was present in the reactor effluent primarily in the form of dissolved Ca(HCO 3 ) 2 . Effluent alkalinity exceeded our target level of 50 mg/L under most operating conditions evaluated with typical pilot scale values falling within the range of 90–100 mg/L despite influent concentrations of about 4 mg/L. Concurrently, CO 2 fell from an average of 50.6 mg/L to 8.3 mg/L (90%), providing for an increase in pH from 5.27 to a mean of 7.71. The ability of the test reactor to provide changes in water chemistry variables that exceeded required changes allowed for a dilution ratio of 0.6. Here, alkalinity still exceeded 50 mg/L, the CO 2 concentration remained well below our limit of 20 mg/L (15.4 mg/L) and the pH was near neutral (7.17). Applying the dilution ratio of 0.6 in a full scale treatment plant at the site reduced by 40% the volume of spring water that is directed through each of three parallel reactors that combined react away 49,000 kg of limestone/yr.

Aquacultural Engineering

Application of a fluidized bed reactor charged with aragonite for control of alkalinity, pH and carbon dioxide in marine recirculating aquaculture systems

Control of alkalinity, dissolved carbon dioxide (dCO 2 ), and pH are critical in marine recirculating aquaculture systems (RAS) in order to maintain health and maximize growth. A small-scale prototype aragonite sand filled fluidized bed reactor was tested under varying conditions of alkalinity and dCO 2 to develop and model the response of dCO 2 across the reactor. A large-scale reactor was then incorporated into an operating marine recirculating aquaculture system to observe the reactor as the system moved toward equilibrium. The relationship between alkalinity dCO 2 , and pH across the reactor are described by multiple regression equations. The change in dCO 2 across the small-scale reactor indicated a strong likelihood that an equilibrium alkalinity would be maintained by using a fluidized bed aragonite reactor. The large-scale reactor verified this observation and established equilibrium at an alkalinity of approximately 135 mg/L as CaCO 3 , dCO 2 of 9 mg/L, and a pH of 7.0 within 4 days that was stable during a 14 day test period. The fluidized bed aragonite reactor has the potential to simplify alkalinity and pH control, and aid in dCO 2 control in RAS design and operation. Aragonite sand, purchased in bulk, is less expensive than sodium bicarbonate and could reduce overall operating production costs.

Aquacultural Engineering