Search USGSSearch

USGS · 70020880

Effect of cable capacitance on in-situ borehole geophone calibration

Abstract

Using 2-Hz electromagnetic moving‐coil geophones as sensing elements, we have constructed and deployed three‐component seismometers in boreholes at various sites for wave‐propagation studies associated with earthquake hazards (Liu et al., 1991). For example, one such seismometer has been deployed in a 88-m deep borehole reaching bedrock in the Marina District of San Francisco since 1990 (Liu et al., 1992) for the purpose of comparing ground motions in the bedrock and those at the surface. Periodic calibrations for such geophones are necessary to check if the geophone parameters have changed because of decreased magnetization of the geophone ferro‐magnet. For example, the coil transductance of the vertical‐component geophone of the borehole seismometer mentioned above was calibrated to be 121 V-s/m using phase‐ellipse test and step test before deployment. Sixty six months after the deployment, the coil transductance, when calibrated in situ and with a 100-m intervening cable between the geophone and the calibration instrument, was found to be 114 V-s/m.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Huaibao P. Liu, R.E. Warrick. 1998. Effect of cable capacitance on in-situ borehole geophone calibration. https://doi.org/10.1190/1.1444312

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Cooperative joint inversion of magnetotelluric and microseismic data for imaging the Geysers geothermal field, California, USA

The Geysers geothermal field located in northern California, USA, is the world’s largest electricity-generating geothermal facility. To delineate the spatio-temporal distribution of reservoir steam and recharge water, we have collected microseismic and magnetotelluric (MT) data using a dense array of stations in 2021. The microseismic and MT data have been inverted together using a 3D cooperative joint inversion workflow. The joint inversion exploits a cross-gradient structural constraint because electrical conductivity structures observed in the geothermal field are strongly correlated with

California

Inversion of induced polarization-affected towed-transient electromagnetic data in a lateritic regolith geology: A case study from western Tanzania

For several decades, induced polarization (IP) effects on transient electromagnetic (TEM) responses have been observed. These effects can manifest as late-time negative transients or as rapidly decaying curves and are usually associated with highly polarizable bodies. If neglected, IP effects can lead to erroneous resistivity models. Recent work allows IP effects to be incorporated into the inversion of TEM data on a more routine basis. In a recent field survey in western Tanzania, strongly IP-affected TEM signals are observed using a towed-transient electromagnetic (tTEM) system. The survey have been carried out to locate drinking water resources in a weathered regolith setting. In these settings, an inversion of tTEM data using a resistivity-only forward model (i.e., IP neglected) cannot fit the data and severely limits the value of the TEM data for hydrogeologic interpretation. To account for IP effects, we have applied a modified version of the Cole-Cole model called the maximum phase angle (MPA) model to invert IP-affected tTEM data. The MPA model incorporates four inversion model parameters: resistivity ( ⁠ ρ "> ρ ), MPA ( ⁠ ϕ max "> ϕ max ⁠ ), relaxation time ( ⁠ τ "> τ ), and frequency exponent ( ⁠ c "> c ). The MPA model fits the data well and improves the reliability of the resistivity model. In much of the surveyed region, the inverted models using MPA display a three-layer system consisting of an upper resistive laterite layer of varying thickness and an intermediate polarizable conductive unit overlying more resistive weathered basement rocks. The conductive polarizable layer is interpreted as a chemically weathered saprolite separating the surficial and deeper aquifers. Overall, tTEM inversion results provide a local understanding of groundwater systems, especially in such regions with very limited subsurface knowledge.

Kaguruka, Kitagata

Evidence-based guidelines for protective actions and earthquake early warning systems

Earthquake early warning systems (EEW) are becoming increasingly available or in development throughout the world. With public alerting in Mexico, Japan, Taiwan, and parts of the United States, it is important to provide evidence-based recommendations for protective action so people can protect themselves when they receive an alert. Best-practice warning communication research suggests that providing a protective action will increase the efficacy of the message. However, given the diversity of earthquakes and building types, as well as social and cultural contexts where these systems exist, the question is: what is the best protective action to recommend? The answer lies in maximizing life-saving protective actions during an earthquake event requires both contextually relevant messaging and widespread public education about appropriate protective actions under a range of conditions. By researching previous earthquake injury literature, examining current best practices and public education campaigns, key protective actions may be determined and used to increase the life-saving potential of earthquake early warning systems.

Geophysics