Abstract

A procedure for the radiochemical neutron-activation analysis for the rare earth elements (REE) involves the separation of the REE as a group by rapid ion-exchange methods and determination of yields by reactivation or by energy dispersive X-ray fluorescence (EDXRF) spectrometry. The U. S. Geological Survey (USGS) standard rocks, BCR-1 and AGV-1, were analyzed to determine the precision and accuracy of the method. We found that the precision was ??5-10% on the basis of replicate analysis and that, in general the accuracy was within ??5% of accepted values for most REE. Data for USGS standard rocks BIR-1 (Icelandic basalt) and DNC-1 (North Carolina diabase) are also presented. ?? 1985 Akade??miai Kiado??.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

G.A. Wandless, J. W. Morgan. 1985. Analysis of low levels of rare earths by radiochemical neutron activation analysis. https://doi.org/10.1007/bf02219757

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Computer graphics for quality control in the INAA of geological samples

A data reduction system for the routine instrumental activation analysis of samples is described, with particular emphasis on interactive graphics capabilities for evaluating analytical quality. Graphics procedures have been developed to interactively control the analysis of selected photopeaks during spectral analysis, and to evaluate detector performance during a given counting cycle. Graphics algorithms are also used to compare the data on reference samples with accepted values, to prepare quality control charts to evaluate long term precision and to search for systematic variations in data on reference samples as a function of time. ?? 1987 Akade??miai Kiado??.

Journal of Radioanalytical and Nuclear Chemistry A

Neutron activation determination of iridium, gold, platinum, and silver in geologic samples

Low-level methods for the determination of iridium and other noble metals have become increasingly important in recent years due to interest in locating abundance anomalies associated with the Cretaceous and Tertiary (K-T) boundary. Typical iridium anomalies are in the range of 1 to 100 ??g/kg (ppb). Thus methods with detection limits near 0.1 ??g/kg should be adequate to detect K-T boundary anomalies. Radiochemical neutron activation analysis methods continue to be required although instrumental neutron activation analysis techniques employing elaborate gamma-counters are under development. In the procedure developed in this study samples irradiated in the epithermal neutron facility of the U. S. Geological Survey TRIGA Reactor (Denver, Colorado) are treated with a mini-fire assay technique. The iridium, gold, and silver are collected in a 1-gram metallic lead button. Primary contaminants at this stage are arsenic and antimony. These can be removed by heating the button with a mixture of sodium perioxide and sodium hydroxide. The resulting 0.2-gram lead bead is counted in a Compton suppression spectrometer. Carrier yields are determined by reirradiation of the lead beads. This procedure has been applied to the U.S.G.S. Standard Rock PCC-1 and samples from K-T boundary sites in the Western Interior of North America. ?? 1987 Akade??miai Kiado??.

Journal of Radioanalytical and Nuclear Chemistry A

Measurements of210Pb,137Cs, organic carbon and trace elements in sediments of the Illinois and Mississippi rivers

Radiometric dating of sediment accumulations by137Cs and210Pb has been successfully initiated in the Illinois and Mississippi Rivers. Sedimentation rates measured at 13 locations range from 0.7 to 3.6 cm/y. Chemical analysis has been completed for up to 45 major and trace elements in core samples. The upper Illinois River contains higher metal levels than the Mississippi River. The amount of carbon (energy) lost to sediments in large floodplain rivers is estimated between 370 and 4000 g/m2/y. ?? 1987 Akade??miai Kiado??.