Utilizing primarily instrumental neutron activation analysis (INAA) and other analytical methods as many as 61 elements were quantitatively surveyed in 170 U.S. whole coals, 70 washed coals, and 40 bench samples. Data on areal and vertical distributions in various regions were obtained along with extensive information on the mode of occurrence of various elements in the coal matrix itself. ?? 1977 Akade??miai Kiado??.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R.R. Ruch, R.A. Cahill, J.K. Frost, L.R. Camp, H.J. Gluskoter. 1977. Survey of trace elements in coals and coal-related materials by neutron activation analysis. https://doi.org/10.1007/bf02520217

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related USGS reports

Chemical characterization of gas- and oil-bearing shales by instrumental neutron activation analysis

The concentration of As, Ba, Ca, Co, Cr, Cs, Dy, Eu, Fe, Ga, Hf, K, La, Lu, Mn, Mo, Na, Ni, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, Yb, and Zn were determined by instrumental neutron activation analysis in block shale samples of the New Albany Group (Devonian-Mississippian) in the in the Illinois Basin. Uranium content of the samples was as high as 75 ppm and interfered in the determination of samarium, molybdenum, barium and cerium. In the determination of selenium a correction was made for interference from tantalum. U, As, Co, Mo, Ni and Sb as well as Cu, V and pyritic sulphur which were determined by other methods, were found to correlate positively with the organic carbon content of the samples. ?? 1982 Akade??miai Kiado??.

Journal of Radioanalytical Chemistry

Anion-exchange separation of Pt and Pd using perchloric and hydrochloric acid solutions

On Biorad Ag-1X8 anion-exchange resin (200-400 mesh), Pd and Pt may be separated from one another by elution with 0.2M HClO4, and 5M HClO4, respectively. If present, Au may be retained by making the elutriants 0.003M in HCl. Alternatively, reduction by H2SO3 enables elution of Pt2+ with 6M HCl before recovery of Pd2+ with 0.2M HClO4??Ir4+ is reduced to Ir3+ by H2SO3 and may be eluted ahead of Pt2+ by 2M HCl. ?? 1982 Akade??miai Kiado??.

Journal of Radioanalytical Chemistry

The precision and accuracy of iterative and non-iterative methods of photopeak integration in activation analysis, with particular reference to the analysis of multiplets

The relative precisions obtainable using two digital methods, and three iterative least squares fitting procedures of photopeak integration have been compared empirically using 12 replicate counts of a test sample with 14 photopeaks of varying intensity. The accuracy by which the various iterative fitting methods could analyse synthetic doublets has also been evaluated, and compared with a simple non-iterative approach. ?? 1977 Akade??miai Kiado??.

Journal of Radioanalytical Chemistry