Search USGSSearch

Geology topics

Research about West Trenton, New Jersey

Source-linked reports with geographic coverage including West Trenton, New Jersey.

11 recordsLinked to original sources

Distribution of chlorinated volatile organic compounds and per- and polyfluoroalkyl substances in groundwater and surface water at the former Naval Air Warfare Center, West Trenton, New Jersey, 2018

Groundwater wells and surface-water storm sewers contaminated with volatile organic compounds (VOCs) and per- and polyfluoroalkyl substances (PFASs) at the former Naval Air Warfare Center (NAWC) site in West Trenton, New Jersey were sampled in 2018 as part of the Navy’s long-term monitoring program. Trichloroethene (TCE), cis-1,2-dichloroethene (cisDCE), and vinyl chloride concentrations were plotted in map view and selected cross sections to elucidate the vertical and horizontal extent and distribution of contamination, along with a tabular comparison between 2018 and previous analytical results. The 2018 data showed that the areas of VOC contamination (>1 microgram per liter) decreased slightly on the north and east sides of the NAWC site from previous sampling dates; these decreases are attributed to the influence of the pump-and-treat system, natural attenuation processes, and various engineered bioaugmentation experiments that have occurred onsite. Off-site groundwater samples indicate the VOC contaminated groundwater is likely hydraulically constrained by the pump-and-treat system and appears to not be moving offsite to the south and west of NAWC. Only one offsite well, 50BR, located along the eastern margin of the site, was found to have detectable TCE and cisDCE concentrations, indicating that VOC contamination continues to migrate a short distance offsite to the east. Detectable VOC contamination was found in wells as deep as 200 and 221 feet on both the east and west sides of the NAWC site. Comparisons of present-day data to data from past sampling efforts indicate that TCE concentrations in most wells have decreased slowly over time. Results from surface-water samples indicate that VOCs enter surface water predominantly through the West Ditch drainage system. Concentrations and fluxes of VOCs are higher when groundwater levels are higher, indicating contaminated groundwater discharges into the surface water system. Higher VOC concentrations at the Interceptor site relative to other sites in the West Ditch indicate the contamination in the West Ditch system is likely caused by contaminated groundwater discharging to the West Ditch storm sewer near manhole MH-140 when water table levels are high. The pump-and-treat extraction wells at the former NAWC site were sampled for per- and polyfluoroalkyl substances (PFAS) in 2018. The suite of reported PFAS include perfluorooctane sulfonate (PFOS), perfluorooctanoic acid (PFOA), perfluorononanoic acid, and perfluorobutane sulfonate. Concentrations were plotted in map view to determine the areal extent of the PFAS contamination at the site. Extraction well 48BR sampled on the eastern half of the site was found to have PFOS and PFOA concentrations greater than the New Jersey Department of Environmental Protection Drinking Water maximum contaminant levels (MCLs), which is consistent with the distribution of highest PFAS concentrations in surface water in the OF-4 storm sewer system that drains that area, as well as previously collected PFAS concentrations in monitoring wells. On the western half of the site, the extraction well 08BR sample exceeded MCLs for PFOA and PFOS and the extraction well 22BR sample exceeded the MCL for PFOA, but samples from all other extraction wells were below the MCLs or other criteria for all PFAS analyzed. Concentrations of PFOA exceeded concentrations of PFOS on the west side of NAWC in both groundwater and surface water, which contrasts with the conditions on the east side of NAWC where PFOS concentrations exceeded PFOA concentrations. However, this observation was based on a limited number of samples on the west side of NAWC from 2018 and previous years, so more PFAS sampling is needed on the west side to assess this further.

New Jersey

Groundwater levels and generalized potentiometric surfaces, former Naval Air Warfare Center, West Trenton, New Jersey, 2018

Groundwater-level conditions, generalized groundwater potentiometric surfaces, and generalized flow directions at the decommissioned Naval Air Warfare Center in West Trenton, New Jersey, were evaluated for calendar year 2018. Groundwater levels measured continuously in five on-site wells and one nearby off-site well were plotted as hydrographs for January 1, 2018, through December 31, 2018. Groundwater levels measured in 110 wells on June 18, 2018, were contoured as generalized potentiometric surfaces on maps and sections. Generalized groundwater-flow directions inferred from the June 2018 data are shown in the maps and sections. Groundwater levels in six monitoring wells fluctuated in response to seasonal changes, precipitation, and pumping from “pump-and-treat” (P&T) wells. Record high precipitation totals in November, combined with a shutdown of three P&T wells in November, resulted in annual high water levels in late November for five of the six wells monitored. Annual high groundwater levels that occur during the fall are uncharacteristic of the typical timing of annual high water levels, which usually occur in the spring following low evapotranspiration during the winter months, compared to annual low water levels, which usually occur in fall because of high evapotranspiration during the summer months. The annual high water levels occurred following a 3-day precipitation event totaling 3.50 inches from November 24-26, which also caused the largest 1-day water-level increase for five of the six wells in 2018. The groundwater-level contour maps and sections include generalized flow directions. Given the heterogeneity of the site’s fractured rock aquifers, contours and associated groundwater-flow directions shown on the maps and sections should be considered as broad conceptualizations. A nearly vertical fault striking southwest to northeast separates the northwestern part of the site underlain by the Lockatong Formation from the southeastern part, which is underlain by the Stockton Formation. In the Lockatong Formation, general groundwater-flow directions were toward P&T wells. The P&T wells limited the flow of groundwater in the Lockatong Formation from the site into the adjacent areas and contained most groundwater contamination within the site. A groundwater divide bisected the site; groundwater in the western part generally flowed to P&T wells 8BR, 15BR, 20BR, 29BR, 56BR, 91BR, and BRP-2, and groundwater in the eastern part generally flowed to P&T well 48BR. A groundwater divide also was present in the Stockton Formation. Groundwater west of the divide in the Stockton Formation generally flowed toward P&T well 22BR, and groundwater east of the divide generally flowed south and southeast, away from the site. Saprolite and fill from land surface to depths of 25 feet below land surface exhibit similar properties to those of porous media, and water levels in surficial wells were contoured using a porous media aquifer approach. Water levels in these surficial wells indicate that groundwater in the saprolite and fill flowed predominantly toward Gold Run and, to a lesser extent, the West Ditch spring that drains to Gold Run. In addition, some shallow groundwater was captured by the cone of depression in the fractured bedrock and was attributed to P&T well 48BR.

New Jersey

The complex spatial distribution of trichloroethene and the probability of NAPL occurrence in the rock matrix of a mudstone aquifer

Methanol extractions for chloroethene analyses are conducted on rock samples from seven closely spaced coreholes in a mudstone aquifer that was subject to releases of the nonaqueous phase liquid (NAPL) form of trichloroethene (TCE) between the 1950's and 1990's. Although TCE concentration in the rock matrix over the length of coreholes is dictated by proximity to subhorizontal bedding planefractures, elevated TCE concentrations in the rock matrix are not continuous along the most permeable bedding plane fractures. A complex configuration of subvertical and subhorizontal fractures appears to be responsible for the TCE distribution from prior TCE releases at land surface. Phase partitioning calculations of TCE in the rock matrix show that most TCE is adsorbed to solid surfaces because of the large fraction of organic carbon ( f oc ) in the mudstone. Large TCE content in some cores indicate the likely presence of the NAPL form of TCE in the rock matrix. Using average values of porosity ( n ) and f oc in phase partitioning calculations identifies a number of locations of possible NAPL occurrence in the rock matrix. Samples of mudstone analyzed for n and f oc show variability in these properties over several orders of magnitude. Accounting for this variability in phase partitioning calculations identifies a probability of NAPL occurrence, P NAPL . The spatial variability of P NAPL along coreholes identifies a configuration that may be attributed to a TCE source zone that has evolved after emplacement due to NAPL dissolution, adsorption, and matrix diffusion.

New Jersey

Bioremediation in fractured rock: 2. Mobilization of chloroethene compounds from the rock matrix

A mass balance is formulated to evaluate the mobilization of chlorinated ethene compounds (CE) from the rock matrix of a fractured mudstone aquifer under pre- and postbioremediation conditions. The analysis relies on a sparse number of monitoring locations and is constrained by a detailed description of the groundwater flow regime. Groundwater flow modeling developed under the site characterization identified groundwater fluxes to formulate the CE mass balance in the rock volume exposed to the injected remediation amendments. Differences in the CE fluxes into and out of the rock volume identify the total CE mobilized from diffusion, desorption, and nonaqueous phase liquid dissolution under pre- and postinjection conditions. The initial CE mass in the rock matrix prior to remediation is estimated using analyses of CE in rock core. The CE mass mobilized per year under preinjection conditions is small relative to the total CE mass in the rock, indicating that current pump-and-treat and natural attenuation conditions are likely to require hundreds of years to achieve groundwater concentrations that meet regulatory guidelines. The postinjection CE mobilization rate increased by approximately an order of magnitude over the 5 years of monitoring after the amendment injection. This rate is likely to decrease and additional remediation applications over several decades would still be needed to reduce CE mass in the rock matrix to levels where groundwater concentrations in fractures achieve regulatory standards.

New Jersey

Imaging pathways in fractured rock using three-dimensional electrical resistivity tomography

Major challenges exist in delineating bedrock fracture zones because these cause abrupt changes in geological and hydrogeological properties over small distances. Borehole observations cannot sufficiently capture heterogeneity in these systems. Geophysical techniques offer the potential to image properties and processes in between boreholes. We used three-dimensional cross borehole electrical resistivity tomography (ERT) in a 9 m (diameter) × 15 m well field to capture high-resolution flow and transport processes in a fractured mudstone contaminated by chlorinated solvents, primarily trichloroethylene. Conductive (sodium bromide) and resistive (deionized water) injections were monitored in seven boreholes. Electrode arrays with isolation packers and fluid sampling ports were designed to enable acquisition of ERT measurements during pulsed tracer injections. Fracture zone locations and hydraulic pathways inferred from hydraulic head drawdown data were compared with electrical conductivity distributions from ERT measurements. Static ERT imaging has limited resolution to decipher individual fractures; however, these images showed alternating conductive and resistive zones, consistent with alternating laminated and massive mudstone units at the site. Tracer evolution and migration was clearly revealed in time-lapse ERT images and supported by in situ borehole vertical apparent conductivity profiles collected during the pulsed tracer test. While water samples provided important local information at the extraction borehole, ERT delineated tracer migration over spatial scales capturing the primary hydrogeological heterogeneity controlling flow and transport. The fate of these tracer injections at this scale could not have been quantified using borehole logging and/or borehole sampling methods alone.

New Jersey

Transmissivity and storage coefficient estimates from slug tests, Naval Air Warfare Center, West Trenton, New Jersey

Slug tests were conducted on 56 observation wells open to bedrock at the former Naval Air Warfare Center (NAWC) in West Trenton, New Jersey. Aquifer transmissivity (T) and storage coefficient (S) values for most wells were estimated from slug-test data using the Cooper-Bredehoeft-Papadopulos method. Test data from three wells exhibited fast, underdamped water-level responses and were analyzed with the Butler high-K method. The range of T at NAWC was approximately 0.07 to 10,000 square feet per day. At 11 wells, water levels did not change measurably after 20 minutes following slug insertion; transmissivity at these 11 wells was estimated to be less than 0.07 square feet per day. The range of S was approximately 10 -10 to 0.01, the mode being 10 -10 . Water-level responses for tests at three wells fit poorly to the type curves of both methods, indicating that these methods were not appropriate for adequately estimating T and S from those data.

New Jersey

Estimated trichloroethene transformation rates due to naturally occurring biodegradation in a fractured-rock aquifer

Rates of trichloroethene (TCE) mass transformed by naturally occurring biodegradation processes in a fractured rock aquifer underlying a former Naval Air Warfare Center (NAWC) site in West Trenton, New Jersey, were estimated. The methodology included (1) dividing the site into eight elements of equal size and vertically integrating observed concentrations of two daughter products of TCE biodegradation– cis -dichloroethene ( cis -DCE) and chloride–using water chemistry data from a network of 88 observation wells; (2) summing the molar mass of cis -DCE, the first biodegradation product of TCE, to provide a probable underestimate of reductive biodegradation of TCE, (3) summing the molar mass of chloride, the final product of chlorinated ethene degradation, to provide a probable overestimate of overall biodegradation. Finally, lower and higher estimates of aquifer porosities and groundwater residence times were used to estimate a range of overall transformation rates. The highest TCE transformation rates estimated using this procedure for the combined overburden and bedrock aquifers was 945 kg/yr, and the lowest was 37 kg/yr. However, hydrologic considerations suggest that approximately 100 to 500 kg/yr is the probable range for overall TCE transformation rates in this system. Estimated rates of TCE transformation were much higher in shallow overburden sediments (approximately 100 to 500 kg/yr) than in the deeper bedrock aquifer (approximately 20 to 0.15 kg/yr), which reflects the higher porosity and higher contaminant mass present in the overburden. By way of comparison, pump-and-treat operations at the NAWC site are estimated to have removed between 1,073 and 1,565 kg/yr of TCE between 1996 and 2009.

New Jersey

Integrated characterization of the geologic framework of a contaminated site in West Trenton, New Jersey

Fractured sedimentary bedrock and groundwater at the former Naval Air Warfare Center in West Trenton, New Jersey (United States of America) are contaminated with chlorinated solvents. Predicting contaminant migration or removing the contaminants requires an understanding of the geology. Consequently, the geologic framework near the site was characterized with four different methods having different spatial scales: geologic field mapping, analyses of bedrock drill core, analyses of soil and regolith, and S-wave refraction surveys. A fault zone is in the southeast corner of the site and separates two distinct sedimentary formations; the fault zone dips (steeply) southeasterly, strikes northeasterly, and extends at least 550 m along its strike direction. Drill core from the fault zone is extensively brecciated and includes evidence of tectonic contraction. Approximately 300 m east of this fault zone is another fault zone, which offsets the contact between the two sedimentary formations. The S-wave refraction surveys identified both fault zones beneath soil and regolith and thereby provided constraints on their lateral extent and location.

New Jersey

Mass of chlorinated volatile organic compounds removed by Pump-and-Treat, Naval Air Warfare Center, West Trenton, New Jersey, 1996-2010

Pump and Treat (P&T) remediation is the primary technique used to contain and remove trichloroethylene (TCE) and its degradation products cis 1-2,dichloroethylene (cDCE) and vinyl chloride (VC) from groundwater at the Naval Air Warfare Center (NAWC), West Trenton, NJ. Three methods were used to determine the masses of TCE, cDCE, and VC removed from groundwater by the P&T system since it became fully operational in 1996. Method 1, is based on the flow volume and concentrations of TCE, cDCE, and VC in groundwater that entered the P&T building as influent. Method 2 is based on withdrawal volume from each active recovery well and the concentrations of TCE, cDCE, and VC in the water samples from each well. Method 3 compares the maximum monthly amount of TCE, cDCE, and VC from Method 1 and Method 2. The greater of the two values is selected to represent the masses of TCE, cDCE and VC removed from groundwater each month. Previously published P&T monthly reports used Method 1 to determine the mass of TCE, cDCE, and VC removed. The reports state that 8,666 pounds (lbs) of TCE, 13,689 lbs of cDCE, and 2,455 lbs of VC were removed by the P&T system during 1996-2010. By using Method 2, the mass removed was determined to be 8,985 lbs of TCE, 17,801 lbs of cDCE, and 3,056 lbs of VC removed, and Method 3, resulted in 10,602 lbs of TCE, 21,029 lbs of cDCE, and 3,496 lbs of VC removed. To determine the mass of original TCE removed from groundwater, the individual masses of TCE, cDCE, and VC (determined using Methods 1, 2, and 3) were converted to numbers of moles, summed, and converted to pounds of original TCE. By using the molar conversion the mass of original TCE removed from groundwater by Methods 1, 2, and 3 was 32,381 lbs, 39,535 lbs, and 46,452 lbs, respectively, during 1996-2010. P&T monthly reports state that 24,805 lbs of summed TCE, cDCE, and VC were removed from groundwater. The simple summing method underestimates the mass of original TCE removed by the P&T system.

New Jersey

Contamination in fractured-rock aquifers: Research at the former Naval Air Warfare Center, West Trenton, New Jersey

The U.S. Geological Survey and cooperators are studying chlorinated solvents in a fractured sedimentary rock aquifer underlying the former Naval Air Warfare Center (NAWC), West Trenton, New Jersey. Fractured-rock aquifers are common in many parts of the United States and are highly susceptible to contamination, particularly at industrial sites. Compared to 'unconsolidated' aquifers, there can be much more uncertainty about the direction and rate of contaminant migration and about the processes and factors that control chemical and microbial transformations of contaminants. Research at the NAWC is improving understanding of the transport and fate of chlorinated solvents in fractured-rock aquifers and will compare the effectiveness of different strategies for contaminant remediation.

New Jersey

Ground-water levels and potentiometric surfaces, Naval Air Warfare Center, West Trenton, New Jersey, 2000

Water levels were measured in wells at the decommissioned Naval Air Warfare Center in West Trenton, N.J., during 2000. Water-level hydro­graphs prepared from data collected at seven obser­vation wells on the base show changes caused by seasonal and daily climate conditions and by the pumping of contaminated water from recovery wells. Stressed and unstressed potentiometric sur­faces for 2000 are similar in shape to those during 1995–99, but are not as deep. The greatest differ­ences between the potentiometric surfaces in 2000 and those in 1995–99 were caused by turning off sump pumps in NAWC buildings when the base was closed.

New Jersey