Search USGSSearch

Geology topics

Research about Trenton, New Jersey

Source-linked reports with geographic coverage including Trenton, New Jersey.

5 recordsLinked to original sources

Microbial community response to a bioaugmentation test to degrade trichloroethylene in a fractured rock aquifer, Trenton, N.J

Bioaugmentation is a promising strategy for enhancing trichloroethylene (TCE) degradation in fractured rock. However, slow or incomplete biodegradation can lead to stalling at degradation byproducts such as 1,2-dichloroethene ( cis -DCE) and vinyl chloride (VC). Over the course of 7 years, we examined the response of groundwater microbial populations in a bioaugmentation test where an emulsified vegetable oil solution (EOS ® ) and a dechlorinating consortium (KB-1 ® ), containing the established dechlorinator Dehalococcoides (DHC), were injected into a TCE-contaminated fractured rock aquifer. Indigenous microbial communities responded within 2 days to added substrate and outcompeted KB-1 ® , and over the years of monitoring, several other notable turnover events were observed. Concentrations of ethene, the end product in reductive dechlorination, had the strongest correlations ( P < .05) with members of Candidatus Colwellbacteria but their involvement in reductive dechlorination is unknown and warrants further investigation.DHC never exceeded 0.6% relative abundance of groundwater microbial communities, despite its previously presumed importance at the site. Increased concentrations of carbon dioxide, acetic acid, and methane were positively correlated with increasing ethene concentrations; however, concentrations of cis- DCE and VC remained high by the end of the monitoring period suggesting preferential enrichment of indigenous partial dechlorinators over bioaugmented complete dechlorinators. This study highlights the importance of characterizing in situ microbial populations to understand how they can potentially enhance or inhibit augmented TCE degradation.

New Jersey

Hydraulic and solute-transport properties and simulated advective transport of contaminated ground water in a fractured-rock aquifer at the Naval Air Warfare Center, West Trenton, New Jersey, 2003

Volatile organic compounds, predominantly trichloroethylene and its degradation products, have been detected in ground water at the Naval Air Warfare Center (NAWC), West Trenton, New Jersey. An air-stripping pump-and-treat system has been in operation at the NAWC since 1998. An existing ground-water-flow model was used to evaluate the effect of a change in the configuration of the network of recovery wells in the pump-and-treat system on flow paths of contaminated ground water. The NAWC is underlain by a fractured-rock aquifer composed of dipping layers of sedimentary rocks of the Lockatong and Stockton Formations. Hydraulic and solute-transport properties of the part of the aquifer composed of the Lockatong Formation were measured using aquifer tests and tracer tests. The heterogeneity of the rocks causes a wide range of values of each parameter measured. Transmissivity ranges from 95 to 1,300 feet squared per day; the storage coefficient ranges from 9 x 10-5 to 5 x 10-3; and the effective porosity ranges from 0.0003 to 0.002. The average linear velocity of contaminated ground water was determined for ambient conditions (when no wells at the site are pumped) using an existing ground-water-flow model, particle-tracking techniques, and the porosity values determined in this study. The average linear velocity of flow paths beginning at each contaminated well and ending at the streams where the flow paths terminate ranges from 0.08 to 130 feet per day. As a result of a change in the pump-and-treat system (adding a 165-foot-deep well pumped at 5 gallons per minute and reducing the pumping rate at a nearby 41-foot-deep well by the same amount), water in the vicinity of three 100- to 165-foot-deep wells flows to the deep well rather than the shallower well.

New Jersey

Flood of July 21, 1975 in Mercer County, New Jersey

Intense rainfall during the evening of July 20 and early morning hours of July 21, 1975 caused flooding of unprecedented magnitude in highly urbanized Mercer County, New Jersey. Over 6 inches (152 millimetres) of rainfall was recorded during a 10-hour period at Trenton, the capital of New Jersey. No lives were lost but damages to highways and bridges, to industrial, business, and residential buildings, to farmlands and crops, and to water supply systems were severe. This report illustrates the magnitude of the flood and provides hydrologic data needed for planning and design to control or lessen damages from future floods. It includes discussions of the antecedent conditions and meteorological aspects of the storm; a description of the flood and comparison to previous floods; a summary of flood stages and discharges; a discussion of flood frequency; and photomosaics which show inundated areas. More than 200 high-water marks are described as to location and elevation above mean sea level.

New Jersey