Search USGS⌕ Search

Geology topics

Research about Pennsylvania

Source-linked reports with geographic coverage including Pennsylvania.

At least 325 records · Page 18Linked to original sources

Evaluation of borehole geophysical logs and hydraulic tests, phase III, at AIW Frank/Mid-County Mustang Superfund Site, Chester County, Pennsylvania

Borehole geophysical logs, heatpulse-flowmeter measurements, and aquifer-isolation tests were used to characterize the ground-water-flow system at the AIW Frank/Mid-County Mustang Superfund Site. The site is underlain by fractured carbonate rocks. Caliper, natural-gamma, single-point-resistance, fluid-resistivity, and fluid-temperature logs were run in six wells, and an acoustic borehole televiewer and borehole deviation log was run in one well. The direction and rate of borehole-fluid movement was measured with a high-resolution heatpulse flowmeter for both nonpumping and pumping conditions in four wells. The heatpulse-flowmeter measurements showed flow within the borehole during nonpumping conditions in three of the four wells tested. Flow rates up to 1.4 gallons per minute were measured. Flow was upward in one well and both upward and downward in two wells. Aquifer-isolation (packer) tests were conducted in four wells to determine depth-discrete specific capacity values, to obtain depth-discrete water samples, and to determine the effect of pumping an individual fracture or fracture zone in one well on water levels in nearby wells. Water-level data collected during aquifer-isolation tests were consistent with and confirmed interpretations of borehole geophysical logs and heatpulse-flowmeter measurements. Seven of the 13 fractures identified as water-producing or water-receiving zones by borehole geophysical methods produced water at a rate equal to or greater than 7.5 gallons per minute when isolated and pumped. The specific capacities of isolated fractures range over three orders of magnitude, from 0.005 to 7.1 gallons per minute per foot. Vertical distribution of specific capacity between land surface and 298 feet below land surface is not related to depth. The four highest specific capacities, in descending order, are at depths of 174-198, 90-92, 118-119, and 34-37 feet below land surface.

Pennsylvania↗

Relation between selected well-construction characteristics and occurrence of bacteria in private household-supply wells, south-central and southeastern Pennsylvania

Total coliform and Escherichia coli ( E. coli ) bacteria were analyzed in ground water sampled from 78 private household-supply wells as part of a study by the U.S. Geological Survey in cooperation with the Pennsylvania Department of Environmental Protection to evaluate the relation between well construction characteristics and the occurrence of bacteria in ground water. Sampling was done in eight counties in south-central and southeastern Pennsylvania from September 2000 to March 2001. All samples were collected from wells in close proximity to agricultural land-use areas. Total coliform bacteria were found in water from 62 percent (48 of 78) of the wells, and bacteria were just as likely to be found in sanitary wells (grouted/loose-fitting well cap or grouted/sanitary sealed well cap) as in nonsanitary wells (nongrouted/ loose-fitting well cap). The areas underlain by carbonate bedrock had the highest percentages of total coliform detected (about 75 percent). Nearly half of the samples collected in the areas underlain by noncarbonate bedrock also were found to have total coliform present. E. coli bacteria were found in water from 10 percent of the wells. Seventeen percent of the samples that were positive for total coliform also were positive for E. coli . The presence of E. coli bacteria was more likely in water from nonsanitary wells. Additionally, the presence of E. coli bacteria was more likely in ground water from wells underlain by carbonate bedrock. A further breakdown of the data into four groups on the basis of sanitary construction and bedrock type indicated the presence of E. coli was more likely in water from nonsanitary wells in areas underlain by carbonate bedrock. Statistical analysis of other well-construction characteristics that might relate to occurrence of bacteria showed that the presence of total coliform bacteria was related to the depth to water-bearing zone in both sanitary and nonsanitary wells in areas underlain by carbonate bedrock. Relations also are present between the presence of total coliform bacteria and casing length in nonsanitary wells in areas underlain by noncarbonate bedrock. Bacteria were found in wells both with and without insects observed on the underside of the well cap. Because of the small number of wells sampled that had sanitary sealed caps, it is uncertain whether installation of sanitary sealed well caps would reduce the incidence of bacteria in ground water from wells or if the presence of bacteria is because of a combination of well-construction characteristics or aquifer-wide contamination of limited or broad areal extent.

Pennsylvania↗

Lateral ramps in the folded Appalachians and in overthrust belts worldwide— A fundamental element of thrust-belt architecture

Lateral ramps are zones where decollements change stratigraphic level along strike; they differ from frontal ramps, which are zones where decollements change stratigraphic level perpendicular to strike. In the Appalachian Mountains, the surface criteria for recognizing the subsurface presence of lateral ramps include (1) an abrupt change in wavelength or a termination of folds along strike, (2) a conspicuous change in the frequency of mapped faults or disturbed zones (extremely disrupted duplexes) at the surface, (3) long, straight river trends emerging onto the coastal plain or into the Appalachian Plateaus province, (4) major geomorphic discontinuities in the trend of the Blue Ridge province, (5) interruption of Mesozoic basins by cross-strike border faults, and (6) zones of modern and probable ancient seismic activity. Additional features related to lateral ramps include tectonic windows, cross-strike igneous intrusions, areas of giant landslides, and abrupt changes in Paleozoic sedimentation along strike. Proprietary strike-line seismic-reflection profiles cross three of the lateral ramps that were identified by using the surface criteria. The profiles confirm their presence and show their detailed nature in the subsurface. Like frontal ramps, lateral ramps are one of two possible consequences of fold-and-thrust-belt tectonics and are common elements in the Appalachian fold-and-thrust belt. A survey of other thrust belts in the United States and elsewhere strongly suggests that lateral ramps at depth can be identified by their surface effects. Lateral ramps probably are the result of thrust sheet motion caused by continued activation of ancient cratonic fracture systems. Such fractures localized the transform faults along which the continental segments adjusted during episodes of sea-floor spreading.

Pennsylvania↗

Naturally occurring radionuclides in the ground water of southeastern Pennsylvania

Naturally occurring radionuclides in the ground water of southeastern Pennsylvania may pose a health hazard to some residents, especially those drinking water from wells drilled in the Chickies Quartzite. Water from 46 percent of wells sampled in the Chickies Quartzite and 7 percent of wells sampled in other geologic formations exceeded the U.S. Environmental Protection Agency (USEPA) maximum contaminant level (MCL) for total radium. Radon-222 may pose a health problem for homeowners by contributing to indoor air radon-222 levels. The radon-222 activity of water from 89 percent of sampled wells exceeded 300 pCi/L (picocuries per liter), the proposed USEPA MCL, and water from 16 percent of sampled wells exceeded 4,000 pCi/L. Uranium does not appear to be present in elevated concentrations in ground water in southeastern Pennsylvania.

Pennsylvania↗

Estimated water withdrawals and use in Pennsylvania, 1995

In practical terms, water use is divided into two basic types: instream use and offstream use. Instream use is water used in its natural channel, basin, or behind a dam and includes activities such as fishing, boating, and other recreational activities. Instream use also includes hydroelectric power generation. Off-stream use is water pumped or diverted from its natural channel, basin, or aquifer. Off-stream uses are divided into the following categories: public supply, domestic, commercial, industrial, thermoelectric power, mining, livestock, and irrigation. This fact sheet provides an overview of offstream and hydroelectric power water use in Pennsylvania. It describes water withdrawals by source, water withdrawals and deliveries by category, changes in water use over time, and water-management responsibilities in the State.

Pennsylvania↗

Evaluation of geophysical logs, Phase II, November 1998 to May 1999, at Crossley Farms Superfund Site, Berks County, Pennsylvania

Between November 1998 and May 1999, geophysical logging was conducted in 29 boreholes at the Crossley Farms Superfund Site, Hereford Township, Berks County, Pa., to determine the fluidproducing zones, fluid-receiving zones, zones of vertical borehole flow, and casing depth. The wells range in depth from 96 to 500 feet below land surface. Gamma logs only were collected in three bedrock wells. The geophysical logging determined the placement of well screens and packers, which allow monitoring and sampling of water-bearing zones in the fractured bedrock so that the horizontal and vertical distribution of contaminated ground water migrating from known sources could be determined. Geophysical logging included collection of caliper, video, fluid-temperature, fluid-resistivity, single-point-resistance, natural-gamma, fluid-flow, and acoustic-televiewer logs. Caliper and video logs were used to locate fractures, joints, and weathered zones. Inflections on fluidtemperature and fluid-resistivity logs indicated possible water-bearing fractures, and flowmeter measurements verified these locations. Single-point-resistance and natural-gamma logs provided information on stratigraphy. After interpretation of geophysical, video logs, and drillers notes, 24 of the wells were reconstructed such that water levels can be monitored and water samples collected from discrete water-bearing fractures in each well.

Pennsylvania↗

Simulation of aquifer tests and ground-water flowpaths at the local scale in fractured shales and sandstones of the Brunswick Group and Lockatong Formation, Lansdale, Montgomery County, Pennsylvania

The U.S. Geological Survey, as part of technical assistance to the U.S. Environmental Protection Agency, has constructed and calibrated models of local-scale ground-water flow in and near Lansdale, Pa., where numerous sources of industrial contamination have been consolidated into the North Penn Area 6 Superfund Site. The local-scale models incorporate hydrogeologic structure of northwest-dipping beds with uniform hydraulic properties identified in previous studies. Computations associated with mapping the dipping-bed structure into the three-dimensional model grid are handled by a preprocessor using a programmed geographic information system (GIS). Hydraulic properties are identified by calibration of the models using measured water levels during pumping and recovery from aquifer tests at three sites. Reduced flow across low-permeability beds is explicitly simulated. The dipping high-permeability beds are extensive in the strike direction but are of limited extent in the dip direction. This model structure yields ground-water-flow patterns characteristic of anisotropic aquifers; preferred flow is in the strike direction. The transmissivities of high-permeability beds in the local-scale models range from 142 to 1,900 ft 2 /d (feet squared per day) (13 to 177 m 2 /d). The hydraulic conductivities of low-permeability parts of the aquifer range from 9.6 x 10 -4 to 0.26 ft/d (feet per day) (2.9 x 10 -4 to 0.079 m/d). Storage coefficients and specific storage are very low, indicating the confined nature of the aquifer system. The calibrated models are used to simulate contributing areas of wells under alternative, hypothetical ground-water-management practices. Predictive contributing areas indicate the general characteristics of ground-water flow towards wells in the Lansdale area. Recharge to wells in Lansdale generally comes from infiltration near the well and over an area that extends upgradient from the well. The contributing areas for two wells pumping at 10 gal/min (gallons per minute) extend about 1,500 ft (feet) upgradient from the wells. The contributing area is more complex at ground-water divides and can extend in more than one direction to capture recharge from more than 3,300 ft away, for pumping at a rate of 30 gal/min. Locally, all recharge in the area of the pumping well is not captured; recharge in the downgradient direction about 150 ft from the pumping well will flow to other discharge locations.

Pennsylvania↗

Hydrogeology and simulation of ground-water flow at the Gettysburg Elevator Plant Superfund Site, Adams County, Pennsylvania

Ground water in Triassic-age sedimentary fractured-rock aquifers in the area of Gettysburg, Pa., is used as drinking water and for industrial and commercial supply. In 1983, ground water at the Gettysburg Elevator Plant was found by the Pennsylvania Department of Environmental Resources to be contaminated with trichloroethene, 1,1,1-trichloroethane, and other synthetic organic compounds. As part of the U.S. Environmental Protection Agency?s Comprehensive Environmental Response, Compensation, and Liability Act, 1980 process, a Remedial Investigation was completed in July 1991, a method of site remediation was issued in the Record of Decision dated June 1992, and a Final Design Report was completed in May 1997. In cooperation with the U.S. Environmental Protection Agency in the hydrogeologic assessment of the site remediation, the U.S. Geological Survey began a study in 1997 to determine the effects of the onsite and offsite extraction wells on ground-water flow and contaminant migration from the Gettysburg Elevator Plant. This determination is based on hydrologic and geophysical data collected from 1991 to 1998 and on results of numerical model simulations of the local ground-water flow-system. The Gettysburg Elevator Site is underlain by red, green, gray, and black shales of the Heidlersburg Member of the Gettysburg Formation. Correlation of natural-gamma logs indicates the sedimentary rock strike about N. 23 degrees E. and dip about 23 degrees NW. Depth to bedrock onsite commonly is about 6 feet but offsite may be as deep as 40 feet. The ground-water system consists of two zones?a thin, shallow zone composed of soil, clay, and highly weathered bedrock and a thicker, nonweathered or fractured bedrock zone. The shallow zone overlies the bedrock zone and truncates the dipping beds parallel to land surface. Diabase dikes are barriers to ground-water flow in the bedrock zone. The ground-water system is generally confined or semi-confined, even at shallow depths. Depth to water can range from flowing at land surface to more than 71 feet below land surface. Potentiometric maps based on measured water levels at the Gettysburg Elevator Plant indicate ground water flows from west to east, towards Rock Creek. Multiple-well aquifer tests indicate the system is heterogeneous and flow is primarily in dipping beds that contain discrete secondary openings separated by less permeable beds. Water levels in wells open to the pumped bed, as projected along the dipping stratigraphy, are drawn down more than water levels in wells not open to the pumped bed. Ground-water flow was simulated for steady-state conditions prior to pumping and long-term average pumping conditions. The three-dimensional numerical flow model (MODFLOW) was calibrated by use of a parameter estimation program (MODFLOWP). Steady-state conditions were assumed for the calibration period of 1996. An effective areal recharge rate of 7 inches was used in model calibration. The calibrated flow model was used to evaluate the effectiveness of the current onsite and offsite extraction well system. The simulation results generally indicate that the extraction system effectively captures much of the ground-water recharge at the Gettysburg Elevator Plant and, hence, contaminated ground-water migrating from the site. Some of the extraction wells pump at low rates and have very small contributing areas. Results indicate some areal recharge onsite will move to offsite extraction wells.

Pennsylvania↗

Detecting change in water quality from implementation of limestone treatment systems in a coal-minded watershed

During 1996-97, a variety of limestone-based treatment systems were implemented to neutralize acidic mine drainage and reduce the transport of dissolved metals in the northern part of the Swatara Creek watershed, which drains a 43-mi2 (112-km2) area in the Southern Anthracite Field upstream from Ravine, Pa. Since 1996, the current project has monitored water quality upstream and downstream of each treatment and at integrator sites on lower reaches of Swatara Creek. Continuous measurements of pH and specific conductance and periodic sampling for alkalinity, acidity, sulfate, and metals upstream and downstream of each treatment system show that (1) open limestone channels and limestone-sand dosing generally had negligible effects on water quality and (2) limestone diversion wells and limestone drains generally were effective at producing near-neutral pH and attenuating dissolved metals during baseflow but were less effective during stormflow conditions. Storm runoff in this area commonly is acidic, and, as streamflow volume increases during stormflow conditions, a smaller fraction of total flow is treated and (or) residence time in the treatment system is reduced. Monitoring on the mainstem of Swatara Creek indicates watershed-scale effects owing primarily to changes in mining practices and secondarily to watershed-wide implementation of treatment systems. Most underground mines in the Swatara Creek Basin were abandoned before 1960 and are presently flooded. Drainage from these mines contributes substantially to baseflow in Swatara Creek. For Swatara Creek at Ravine, Pa., which is immediately downstream of the mined area, long-term data collected since 1959 indicate sulfate concentration declined from about 150 mg/L in 1959 to 75 mg/L in 1999; pH increased sharply from 3.5-4.4 (median ~4) to 4.6-7.0 (median ~6) after 1975. These trends resulted from a decline in pyrite oxidation and the onset of carbonate buffering. Because these long-term attenuation processes have had such a pronounced effect on water quality in Swatara Creek, the effects of recent implementation of limestone treatments are difficult to detect at a watershed scale. Nevertheless, during ecological surveys prior to 1991, no fish were found in Swatara Creek at Ravine. Only six species of fish were found in 1994 and 1996. However, increasing numbers of fish have been found annually since 1996. In 1999, 21 species of fish were documented. The recent monitoring on the mainstem of Swatara Creek indicates the limestone treatments mitigate extreme fluctuations in pH during storm events; however, additional buffering capacity is needed to maintain near-neutral pH of Swatara Creek during large storm events. Concentration 2 of sulfate, specific conductance, and pH are inversely related to streamflow at Ravine, indicating dilution and acidification during stormflow. Declines in stream-water pH to values approaching 5.0 could result in the remobilization of adsorbed or precipitated metals associated with sediments; declines in pH below 5.0 could cause injury to aquatic organisms. Generally, to maintain stream pH during storms, additional or larger limestone diversion wells could be constructed to begin or increase alkalinity production as the stream stage rises and/or additional or larger limestone drains could be constructed to produce greater amounts of alkalinity and enhance the buffering capacity of baseflow.

Pennsylvania↗

Relations among sulfate, metals, sediment, and streamflow data for a stream draining a coal-mined watershed in East-Central Pennsylvania

Streamflow and water-quality data for the northern part of Swatara Creek, which drains a 112-km 2 area in the Southern Anthracite Field of east-central Pennsylvania, indicate iron, copper, and lead, and to a lesser extent manganese and zinc, are transported with suspended particles during stormflow conditions. During stormflow conditions, concentrations of these constituents typically peak prior to peak stream stage as a result of scour and transport of streambed deposits. In contrast, sulfate is transported mostly as a dissolved ion. Concentrations of sulfate, specific conductance, and pH are inversely related to streamflow, indicating dilution and acidification during stormflow. This effect is attributed to the mixing of poorly buffered stream water having pH 6.0-6.5 with weakly acidic storm runoff having pH 4.0-4.5 and low dissolved solids.

Pennsylvania↗

Physical, chemical, and biological data for selected streams in Chester County, Pennsylvania, 1981-94

Physical, chemical, and biological data were collected at 51 sampling sites in Chester County, Pa., from 1970 through 1994 as part of the Stream Conditions of Chester County Program. This report presents data collected from 1981 through 1994. Physical data include water temperature, instantaneous stream discharge, pH, alkalinity, specific conductance, and dissolved oxygen. Chemical data include laboratory determinations of nutrients, major ions, and selected metals in whole water samples and selected metals, pesticides, gross polychlorinated biphenyls (PCB's), gross polychlorinated napthalenes (PCN's), and total carbon in stream-bottom sediment samples. The biological data consists of benthic macroinvertebrate population analyses and diversity indices. Chester County is undergoing rapid urbanization as agricultural lands are converted to residential, commercial, and industrial areas. The purpose of the Stream Conditions of Chester County Program is to further the understanding of stream habitat and chemical changes in response to this urbanization.

Pennsylvania↗

Analysis of geophysical logs, at North Penn Area 6 Superfund Site, Lansdale, Montgomery County, Pennsylvania

The U.S. Geological Survey (USGS), as part of technical assistance to the U.S. Environmental Protection Agency (USEPA), collected borehole geophysical log data in 34 industrial, commercial, and public supply wells and 28 monitor wells at the North Penn Area 6 Superfund Site, in Lansdale, Pa., from August 22, 1995, through August 29, 1997. The wells range in depth from 50 to 1,027 feet below land surface and are drilled in Triassic-age shales and siltstones of the Brunswick Group and Lockatong Formation. The geophysical log data were collected to help describe the hydrogeologic framework in the area and to provide guidance in the reconstruction of the 28 monitor wells drilled during summer 1997. At the time of logging, all wells had open-hole construction. The geophysical logs, caliper, fluid-resistivity, and fluid-temperature, and borehole video logs were used to determine the vertical distribution of water-bearing fractures. Heatpulse-flowmeter measurements were used to determine vertical borehole flow under pumping and nonpumping conditions. The most productive fractures generally could be determined from heatpulse-flowmeter measurements under pumping conditions. Vertical borehole flow was measured under nonpumping conditions in most wells that had more than one water-bearing fracture. Upward flow was measured in 35 wells and probably is a result of natural head differences between fractures in the local ground-water-flow system. Downward flow was measured in 11 wells and commonly indicated differences in hydraulic heads of the fractures caused by nearby pumping. Both upward and downward flow was measured in three wells. No flow was detected in eight wells. Natural-gamma-ray logs were used to estimate the attitude of bedding. Thin shale marker beds, shown as spikes of elevated radioactivity in the natural-gamma logs of some wells throughout the area, enable the determination of bedding-plane orientation from three-point correlations. Generally, the marker beds in and near Lansdale strike about N. 48°-60° E. and dip about 11° NW. Acoustic televiewer logs run in selected boreholes indicate that the attitude of many water-bearing fractures commonly is similar to that of bedding.

Pennsylvania↗

Evaluation of geophysical logs, Phase II, at Willow Grove Naval Air Station Joint Reserve Base, Montgomery County, Pennsylvania

Between March and April 1998, the U.S. Navy contracted Tetra Tech NUS Inc., to drill two monitor wells in the Stockton Formation at the Willow Grove Naval Air Station Joint Reserve Base, Horsham Township, Montgomery County, Pa. The wells MG-1634 and MG-1635 were installed to monitor water levels and sample contaminants in the shallow, intermediate, and deep water-producing zones of the fractured bedrock. Chemical analyses of the samples will help determine the horizontal and vertical distribution of any contaminated ground water migrating from known contaminant sources. Wells were drilled near the Fire Training Area (Site 5). Depths of all boreholes range from 69 to 149 feet below land surface. The U.S. Geological Survey conducted borehole geophysical logging and video surveys to identify water-producing zones in newly drilled monitor wells MG-1634 and MG-1635 and in wells MG-1675 and MG-1676. The logging was conducted from March 5, 1998, to April 16, 1998. This work is a continuation of the Phase I work. Caliper logs and video surveys were used to locate fractures; inflections on fluid-temperature and fluid-resistivity logs were used to locate possible water-producing fractures. Heatpulse-flowmeter measurements were used to verify the locations of water-producing or water-receiving zones and to measure rates of flow between water-bearing fractures. Single-point-resistance and natural-gamma logs provided information on stratigraphy. After interpretation of geophysical logs, video surveys, and driller's notes, wells MG-1634 and MG-1635 were screened such that water-levels fluctuations could be monitored and discrete water samples collected from one or more water-producing zones in each borehole.

Pennsylvania↗