Search USGSSearch

Geology topics

Research about Milford, New Hampshire

Source-linked reports with geographic coverage including Milford, New Hampshire.

7 recordsLinked to original sources

Numerical modeling of groundwater flow in the crystalline-rock aquifer in the vicinity of the Savage Municipal Water-Supply Well Superfund site, Milford, New Hampshire

In 2010, tetrachloroethylene (PCE), a chlorinated volatile organic compound, was detected in groundwater from deep (more than 300 feet below land surface) fractures in monitoring wells tapping a crystalline-rock aquifer. The aquifer underlies the Milford-Souhegan glacial-drift aquifer, a high water-producing aquifer, and the Savage Municipal Water-Supply Well Superfund site in Milford, New Hampshire. Between 30 and 40 residential water-supply wells are near (0.25 mile north of) the PCE-contaminated monitoring wells. Some of the residential water-supply wells are likely installed in similar rock types and formations as those of the monitoring wells installed as part of the Superfund site. As of 2020, periodic sampling by the U.S. Environmental Protection Agency and New Hampshire Department of Environmental Services (cooperative partners for this study) since 1996 had not detected PCE in groundwater from the residential water-supply wells. Nevertheless, understanding the vulnerability of the residential water wells to capture PCE contaminated groundwater was of concern. A numerical groundwater flow model was developed by the U.S. Geological Survey to assess groundwater flow and advective transport of PCE-contaminated groundwater in the crystalline-rock aquifer of the Milford area. The model (called the area-wide model) encompasses a 26.5-square mile area to allow for more accurate computation of water fluxes near the PCE-contaminated monitoring wells and the residential water wells. Simulations with the area-wide model show that, with the 2016 configuration of residential wells, capture of PCE by the residential water wells appears unlikely for hydrologic conditions typical of 2010 based on steady-state, advective transport modeling. However, simulations also show that adding residential water wells to the north of the PCE-contaminated monitoring wells could affect the transport of PCE. Groundwater withdrawals at other adjacent wells in the overlying Milford-Souhegan glacial-drift aquifer affect advective transport in the crystalline-rock aquifer. Therefore, the potential for future changes in withdrawals in the area, as well as changes in hydrologic conditions, including groundwater recharge and streamflow amounts, should be considered in the remedial assessment process. The development of the area-wide model and linkages established by this study with previously developed Milford-Souhegan glacial-drift aquifer transport models will help facilitate the development of remedial strategies for this Superfund site.

New Hampshire

Geochemical, isotopic, and dissolved gas characteristics of groundwater in a fractured crystalline-rock aquifer, Savage Municipal Well Superfund site, Milford, New Hampshire, 2011

Tetrachloroethylene (PCE), a volatile organic compound, was detected in groundwater from deep (more than (>) 300 feet (ft) below land surface) fractures in monitoring wells tapping a crystalline-rock aquifer beneath operable unit 1 (OU1) of the Savage Municipal Well Superfund site (Weston, Inc., 2010). Operable units define remedial areas of contaminant concern. PCE contamination within the fractured-rock aquifer has been designated as a separate operable unit, operable unit 3 (OU3; Weston, Inc., 2010). PCE contamination was previously detected in the overlying glacial sand and gravel deposits and basal till, hereafter termed the Milford-Souhegan glacial-drift (MSGD) aquifer (Harte, 2004, 2006). Operable units 1 and 2 encompass areas within the MSGD aquifer, whereas the extent of the underlying OU3 has yet to be defined. The primary original source of contamination has been identified as a former manufacturing facility—the OK Tool manufacturing facility; hence OU1 sometimes has been referred to as the OK Tool Source Area (New Hampshire Department of Environmental Services, undated). A residential neighborhood of 30 to 40 houses is located in close proximity (one-quarter of a mile) from the PCE-contaminated monitoring wells. Each house has its own water-supply well installed in similar rocks as those of the monitoring wells, as indicated by the New Hampshire State geologic map (Lyons and others, 1997). An investigation was initiated in 2010 by the U.S. Environmental Protection Agency (USEPA) region 1, and the New Hampshire Department of Environmental Services (NHDES) to assess the potential for PCE transport from known contaminant locations (monitoring wells) to the residential wells. The U.S. Geological Survey (USGS) and the NHDES entered into a cooperative agreement in 2011 to assist in the evaluation of PCE transport in the fractured-rock aquifer. Periodic sampling over the last decade by the USEPA and NHDES has yet to detect PCE in groundwater from the residential-supply wells (as of 2012). However, part of assessing the potential for PCE transport involves understanding the origin of the groundwater in the monitoring and residential wells. One of the tools in delineating the movement of groundwater to wells, particularly in complex, highly heterogeneous fractured-rock aquifers, is the understanding of the geochemical and isotopic composition of groundwater (Lipfert and Reeve, 2004; Harte and others, 2012). This report summarizes findings from analyses of geochemical, isotopic, and dissolved gas characteristics of groundwater. Samples of groundwater were collected in 2011 from monitoring wells and nearby residential-supply wells in proximity to OU1.

New Hampshire

Bedrock geology and outcrop fracture trends in the vicinity of the Savage Municipal Well Superfund site, Milford, New Hampshire

The Savage Municipal Well Superfund site consists of an eastward-directed plume of volatile organic compounds, principally tetrachloroethylene (PCE), in alluvium and glacial sand and gravel in the Souhegan River valley, just south of the river and about 4 kilometers west of the town of Milford, New Hampshire. Sampling of monitoring wells at the site has helped delineate the extent of the plume and has determined that some contaminant has migrated into the underlying crystalline bedrock, including bedrock north of the river within 200 meters of a nearby residential development that was constructed in 1999. Borehole geophysical logging has identified a northeast preferential trend for bedrock fractures, which may provide a pathway for the migration of contaminant under and north of the Souhegan River. The current study investigates the bedrock geologic setting for the site, including its position relative to known regional geologic structures, and compiles new strike and dip measurements of joints in exposed bedrock to determine if there are dominant trends in orientation similar to what was found in the boreholes. The site is located on the northwestern limb of a northeast-trending regional anticlinorium that is southeast of the Campbell Hill fault zone. The Campbell Hill fault zone defines the contact between granite and gneiss of the anticlinorium and granite and schist to the northwest and is locally marked by lenses of massive vein quartz, minor faults, and fracture zones that could potentially affect plume migration. The fault zone was apparently not intercepted by any of the boreholes that were drilled to delineate the contaminant plume and therefore passes to the north of the northernmost borehole in the vicinity of the new residential area. Joints measured in surface exposures indicate a strong preferred direction of strike to the north-northeast corroborating the borehole data and previous outcrop and geophysical studies. The north-northeast preferred direction matches the direction of elongation of the cone of depression formed during a pump test of the bedrock wells and could explain a potential pathway for the migration of contaminant north of the river.

New Hampshire

Evaluation of modeling for groundwater flow and tetrachloroethylene transport in the Milford-Souhegan glacial-drift aquifer at the Savage Municipal Well Superfund site, Milford, New Hampshire, 2011

The U.S. Geological Survey and the New Hampshire Department of Environmental Services entered into a cooperative agreement to assist in the evaluation of remedy simulations of the MSGD aquifer that are being performed by various parties to track the remedial progress of the PCE plume. This report summarizes findings from this evaluation. Topics covered include description of groundwater flow and transport models used in the study of the Savage Superfund site (section 2), evaluation of models and their results (section 3), testing of several new simulations (section 4), an assessment of the representation of models to simulate field conditions (section 5), and an assessment of models as a tool in remedial operational decision making (section 6).

New Hampshire

Hydrostratigraphic mapping of the Milford-Souhegan glacial drift aquifer, and effects of hydrostratigraphy on transport of PCE, Operable Unit 1, Savage Superfund Site, Milford, New Hampshire

The Savage Municipal Well Superfund site in the Town of Milford, New Hampshire, was underlain by a 0.5-square mile plume (as mapped in 1994) of volatile organic compounds (VOCs), most of which consisted of tetrachloroethylene (PCE). The plume occurs mostly within highly transmissive stratified-drift deposits but also extends into underlying till and bedrock. The plume has been divided into two areas called Operable Unit 1 (OU1), which contains the primary source area, and Operable Unit 2 (OU2), which is defined as the extended plume area outside of OU1. The OU1 remedial system includes a low-permeability barrier wall that encircles the highest detected concentrations of PCE and a series of injection and extraction wells to contain and remove contaminants. The barrier wall likely penetrates the full thickness of the sand and gravel; in many places, it also penetrates the full thickness of the underlying basal till and sits atop bedrock. From 1998 to 2004, PCE concentrations decreased by an average of 80 percent at most wells outside the barrier wall. However, inside the barrier, PCE concentrations greater than 10,000 micrograms per liter (μg/L) still exist (2008). The remediation of these areas of recalcitrant PCE presents challenges to successful remediation. The U.S. Geological Survey (USGS), in cooperation with the New Hampshire Department of Environmental Services (NHDES) and the U.S. Environmental Protection Agency (USEPA), Region 1, is studying the solute transport of VOCs (primarily PCE) in contaminated groundwater in the unconsolidated sediments (overburden) of the Savage site and specifically assisting in the evaluation of the effectiveness of remedial operations in the OU1 area. As part of this effort, the USGS analyzed the subsurface stratigraphy to help understand hydrostratigraphic controls on remediation. A combination of lithologic, borehole natural gamma-ray and electromagnetic (EM) induction logging, and test drilling has identified 11 primary hydrostratigraphic units in OU1. These 11 units consist of several well-sorted sandy layers with some gravel that are separated by poorly sorted cobble layers with a fine-grained matrix. Collectively these units represent glacial sediments deposited by localized ice-margin fluctuations. For the most part, the units are semi-planar, particularly the cobble units, and truncated by an undulating bedrock surface. The lowermost unit is a basal till that ranges in thickness from zero to greater than 10 feet and mantles the bedrock surface. The 11 units have different lithologic and hydraulic characteristics. The hydraulic conductivity of the well-sorted sand and gravel units is typically greater than the conductivity of the poorly sorted cobble units and the basal till. The hydraulic conductivity ranges from 5 to greater than 500 feet per day. Lateral and vertical variation in lithology and hydraulic conductivity are inferred by variations in borehole natural gamma-ray counts and estimates of hydraulic conductivity. The comparison of hydrostratigraphic units with the spatial distribution of PCE concentrations suggests that solute transport away from source areas is primarily lateral within the permeable sandy units in the middle to lower parts of the aquifer. Along the centerline of the interior barrier area, highest PCE concentrations are in the sandy units to the east of suspected source areas.

New Hampshire