Search USGSSearch

Geology topics

Research about Florida

Source-linked reports with geographic coverage including Florida.

22 records · Page 2Linked to original sources

An optimized network for phosphorus load monitoring for Lake Okeechobee, Florida

Phosphorus load data were evaluated for Lake Okeechobee, Florida, for water years 1982 through 1991. Standard errors for load estimates were computed from available phosphorus concentration and daily discharge data. Components of error were associated with uncertainty in concentration and discharge data and were calculated for existing conditions and for 6 alternative load-monitoring scenarios for each of 48 distinct inflows. Benefit-cost ratios were computed for each alternative monitoring scenario at each site by dividing estimated reductions in load uncertainty by the 5-year average costs of each scenario in 1992 dollars. Absolute and marginal benefit-cost ratios were compared in an iterative optimization scheme to determine the most cost-effective combination of discharge and concentration monitoring scenarios for the lake. If the current (1992) discharge-monitoring network around the lake is maintained, the water-quality sampling at each inflow site twice each year is continued, and the nature of loading remains the same, the standard error of computed mean-annual load is estimated at about 98 metric tons per year compared to an absolute loading rate (inflows and outflows) of 530 metric tons per year. This produces a relative uncertainty of nearly 20 percent. The standard error in load can be reduced to about 20 metric tons per year (4 percent) by adopting an optimized set of monitoring alternatives at a cost of an additional $200,000 per year. The final optimized network prescribes changes to improve both concentration and discharge monitoring. These changes include the addition of intensive sampling with automatic samplers at 11 sites, the initiation of event-based sampling by observers at another 5 sites, the continuation of periodic sampling 12 times per year at 1 site, the installation of acoustic velocity meters to improve discharge gaging at 9 sites, and the improvement of a discharge rating at 1 site.

Florida

Hydrologic and water-quality conditions in the Horse Creek basin, west-central Florida, October 1992-February 1995

A baseline study of the 241-square-mile Horse Creek basin was undertaken from October 1992 to February 1995 to assess the hydrologic and water-quality conditions of one of the last remaining undeveloped basins in west-central Florida. During the period of the study, much of the basin remained in a natural state, except for limited areas of cattle and citrus production and phosphate mining. Rainfall in 1993 and 1994 in the Horse Creek basin was 8 and 31 percent, respectively, above the 30-year long-term average. The lowest and highest maximum instantaneous peak discharge of the six daily discharge stations occurred at the Buzzard Roost Branch and the Horse Creek near Arcadia stations with 185 to 4,180 cubic feet per second, respectively. The Horse Creek near Arcadia station had the lowest number of no-flow days with zero days and the Brushy Creek station had the highest number with 113 days. During the study, the West Fork Horse Creek subbasin had the highest daily mean discharge per square mile with 30.6 cubic feet per second per square mile, and the largest runoff coefficient of 43.7 percent. The Buzzard Roost Branch subbasin had the lowest daily mean discharge per square mile with 5.05 cubic feet per second per square mile, and Brushy Creek and Brandy Branch shared the lowest runoff coefficient of 0.6 percent. Brandy Branch had the highest monthly mean runoff in both 1993 and 1994 with 11.48 and 19.28 inches, respectively. During the high-baseflow seepage run, seepage gains were 8.87 cubic feet per second along the 43-mile Horse Creek channel. However, during the low-baseflow seepage run, seepage losses were 0.88 cubic foot per second. Three methods were used to estimate average annual ground-water recharge in the Horse Creek basin: (1) well hydrograph, (2) chloride mass balance, and (3) streamflow hydrograph. Estimated average annual recharge using these three methods ranged from 3.6 to 8.7 inches. The high percentage of carbonate plus bicarbonate analyzed at the Carlton surficial aquifer well could indicate an upward ground-water flow from the underlying intermediate aquifer system. Based on constituent concentrations in water samples from the six daily discharge stations, concentrations generally are lower in the upper three subbasins, West Fork Horse Creek, Upper Horse Creek, and Brushy Creek than in the lower three subbasins. Typically, concentrations were highest for major ions at Buzzard Roost Branch and nutrients at Brushy Creek.

Florida

Application of acoustical methods for estimating water flow and constituent loads in Perdido Bay, Florida

Water flow and quality data were collected from December 1994 to September 1995 to evaluate variations in discharge, water quality, and chemical fluxes (loads) through Perdido Bay, Florida. Data were collected at a cross section parallel to the U.S. Highway 98 bridge. Discharges measured with an acoustic Doppler current profiler (ADCP) and computed from stage-area and velocity ratings varied roughly between + or - 10,000 cubic feet per second during a typical tidal cycle. Large reversals in flow direction occurred rapidly (less than 1 hour), and complete reversals (resulting in near peak net-upstream or downstream discharges) occurred within a few hours of slack water. Observations of simultaneous upstream and downstream flow (bidirectional flow) were quite common in the ADCP measurements, with opposing directions of flow occurring predominantly in vertical layers. Continuous (every 15 minutes) discharge data were computed for the period from August 18, 1995, to September 28, 1995, and filtered daily mean discharge values were computed for the period from August 19 to September 26, 1995. Data were not computed prior to August 18, 1995, either because of missing data or because the velocity rating was poorly defined (because of insufficient data) for the period prior to landfall of hurricane Erin (August 3, 1995). The results of the study indicate that acoustical techniques can yield useful estimates of continuous (instantaneous) discharge in Perdido Bay. Useful estimates of average daily net flow rates can also be obtained, but the accuracy of these estimates will be limited by small rating shifts that introduce bias into the instantaneous values that are used to compute the net flows. Instantaneous loads of total nitrogen ranged from -180 to 220 grams per second for the samples collected during the study, and instantaneous loads of total phosphorous ranged from -10 to 11 grams per second (negative loads indicate net upstream transport). The chloride concentrations from the water samples collected from Perdido Bay indicated a significant amount of mixing of saltwater and freshwater. Mixing effects could greatly reduce the accuracy of estimates of net loads of nutrients or other substances. The study results indicate that acoustical techniques can yield acceptable estimates of instantaneous loads in Perdido Bay. However, estimates of net loads should be interpreted with great caution and may have unacceptably large errors, especially when saltwater and freshwater concentrations differ greatly.

Florida

Magnitude and frequency of low flows in the Suwannee River Water Management District, Florida

Low-flow frequency statistics for 20 gaging stations having at least 10 years of continuous record and 31 other stations having less than 10 years of continu ous record or a series of at least two low- flow measurements are presented for unregulated streams in the Suwannee River Water Management District in north-central Florida. Statistics for the 20 continuous-record stations included are the annual and monthly minimum consecutive-day average low- flow magnitudes for 1, 3, 7, 14, and 30 consecutive days for recurrence intervals of 2, 5, 10, 20, and, for some long-term stations, 50 years, based on records available through the 1994 climatic year.Only theannual statistics are given for the 31 other stations; these are for the 7- and 30-consecutive day periods only and for recurrence intervals of 2 and 10 years only. Annual low-flow frequency statistics range from zero for many small streams to 5,500 cubic feet per second for the annual 30- consecutive-day average flow with a recurrenceinterval of 2 years for the Suwannee River near Wilcox (station 02323500). Monthly low-flow frequency statistics range from zero for many small streams to 13,800 cubic feet per second for the minimum 30-consecutive-day average flow with a 2-year recurrence interval for the month of March for the same station. Generally, low-flow characteristics of streams in the Suwannee River Water Management District are controlled by climatic, topographic, and geologic fac tors. The carbonate Floridan aquifer system underlies, or is at the surface of, the entire District. The terrane's karstic nature results in many sinkholes and springs. In some places, springs may contribute greatly to low streamflow and the contributing areas of such springs may include areas outside the presumed surface drainage area of the springs. In other places, water may enter sinkholes within a drainage basin, then reappear in springs downstream from a gage. Many of the smaller streams in the District go dry or have no flow for several months in many years. In addition to the low-flow statistics, four synoptic low-flow measurement surveys were conducted on 161 sites during 1990, 1995, and 1996. The measurements were made to provide "snapshots" of flow conditions of streams throughout the Suwannee River Water Management District. Magnitudes of low flows during the 1990 series of measurements were in the range associated with minimum 7-consecutive-day 50-year recurrence interval to the minimum 7-consecutive-day 20-year recurrence interval, except in Taylor and Dixie Counties, where the magnitudes ranged from the minimum 7-consecutive-day 5-year flow level to the7-consecutive-day 2-year flow level. The magnitudes were all greater than the minimum 7- consecutive-day 2-year flow level during 1995 and 1996. Observations of no flow were recorded at many of the sites for all four series of measurements.

Florida