Long-term trends in microseismicity during operational shut-ins at the Coso Geothermal Field, California

Pausing injection and production can lead to induced seismicity in a variety of settings, with some of the largest events occurring during these so-called shut-ins. In geothermal fields, shut-ins are periodically conducted for maintenance on wells and surface infrastructure, thereby offering recurring means of estimating stress changes in the subsurface that lead to increased seismicity rates. Here, we examine daily production and microseismicity data from the Coso Geothermal Field (CGF) in California between 1996 and 2010 to investigate the repetitive trends of operational shut-in microseismicity. Using 24 local seismic stations, we first analyze spatial and temporal trends of over 60,000 earthquakes with magnitudes between -0.4 to 3.8. We find that the northern region exhibits no significant seismicity changes during shut-ins, whereas the rest of the field experiences induced seismicity during almost every shut-in with an increasing intensity towards the southern and eastern portions of the field, highlighting local differences in stress within the CGF. Additionally, we cluster the seismicity using waveform cross-correlation, revealing several earthquake clusters primarily occurring during shut-in periods. These observations suggest that certain fracture and fault sections respond quicker to changes in pore pressure and poroelastic stresses within the geothermal system, possibly highlighting main fluid pathways.

California↗

Micro-seismicity within the Coso Geothermal field, California, from 1996-2012

We extend our previous catalog of seismicity within the Coso Geothermal field by adding over two and a half years of additional data to prior results. In total, we locate over 16 years of seismicity spanning from April 1996 to May of 2012 using a refined velocity model, apply it to all events and utilize differential travel times in relocations to improve the accuracy of event locations. The improved locations elucidate major structural features within the reservoir that we interpret to be faults that contribute to heat and fluid flow within the reservoir. Much of the relocated seismicity remains diffuse between these major structural features, suggesting that a large volume of accessible and distributed fracture porosity is maintained within the geothermal reservoir through ongoing brittle failure. We further track changes in b value and seismic moment release within the reservoir as a whole through time. We find that b values decrease significantly during 2009 and 2010, coincident with the occurrence of a greater number of moderate magnitude earthquakes (3.0 ≤ ML < 4.5). Analysis of spatial variations in seismic moment release between years reveals that localized seismicity tends to spread from regions of high moment release into regions with previously low moment release, akin to aftershock sequences. These results indicate that the Coso reservoir is comprised of a network of fractures at a variety of spatial scales that evolves dynamically over time, with progressive changes in characteristics of microseismicity and inferred fractures and faults that are only evident from a long period of seismic monitoring analyzed using self-consistent methods.

California↗

Analysis and interpretation of stress indicators in deviated wells of the Coso Geothermal Field

Characterizing the tectonic stress field is an integral part of the development of hydrothermal systems and especially for enhanced geothermal systems (EGS). With a well characterized stress field the propensity of fault slip on faults with known location and orientation can be identified. Faults that are critically oriented for faulting with respect to the stress field are known to provide natural fluid pathways. A high slip tendency makes a fault a likely candidate for reactivation during the creation of an EGS. Similarly, the stress state provides insight for the potential of larger, damaging earthquakes should extensive portions of well-oriented, larger faults be reactivated. The analysis of stress indicators such as drilling-induced fractures and borehole breakouts is the main tool to infer information on the stress state of a geothermal reservoir. The standard procedure is applicable to sub-vertical wellbore sections and highly deviated sections have to be discarded. However, in order to save costs and reduce the environmental impact most recent wells are directionally drilled with deviations that require appropriate consideration of the deviated trajectory. Here we present an analysis scheme applicable to arbitrary well trajectories or a combination of wells to infer the stress state. Through the sampling of the stress tensor along several directions additional information on the stress regime and even relative stress magnitudes can be obtained. We apply this method on image logs from the pair of wells 58-10 and 58A-10 that were drilled from the same well pad. Both wells have image logs of about 2km of their trajectories that are separated by less than 300m. For both wells we obtain a mean orientation of S Hmax of N23° with large standard deviations of locations of stress indicators of 24° and 26°, respectively. While the local stress direction is highly variable along both wells with dominant wavelengths from around 50 to 500m, the mean directions are very consistent and also agree with previous stress estimates in the eastern part of the Coso Geothermal Field. In order to obtain a reliable estimation of the stress orientation in this setting, it is necessary to sample the stress field on an interval long to capture several of the dominant wavelengths.

California↗

Differentiating induced and natural seismicity using space-time-magnitude statistics applied to the Coso Geothermal field

A remarkable characteristic of earthquakes is their clustering in time and space, displaying their self-similarity. It remains to be tested if natural and induced earthquakes share the same behavior. We study natural and induced earthquakes comparatively in the same tectonic setting at the Coso Geothermal Field. Covering the preproduction and coproduction periods from 1981 to 2013, we analyze interevent times, spatial dimension, and frequency-size distributions for natural and induced earthquakes. Individually, these distributions are statistically indistinguishable. Determining the distribution of nearest neighbor distances in a combined space-time-magnitude metric, lets us identify clear differences between both kinds of seismicity. Compared to natural earthquakes, induced earthquakes feature a larger population of background seismicity and nearest neighbors at large magnitude rescaled times and small magnitude rescaled distances. Local stress perturbations induced by field operations appear to be strong enough to drive local faults through several seismic cycles and reactivate them after time periods on the order of a year.

California↗

Micro-seismicity and seismic moment release within the Coso Geothermal Field, California

We relocate 16 years of seismicity in the Coso Geothermal Field (CGF) using differential travel times and simultaneously invert for seismic velocities to improve our knowledge of the subsurface geologic and hydrologic structure. We expand on our previous results by doubling the number of relocated events from April 1996 through May 2012 using a new field-wide 3-D velocity model. Relocated micro-seismicity sharpens in many portions of the active geothermal reservoir, likely defining large-scale fault zones and fluid pressure compartment boundaries. However, a significant fraction of seismicity remains diffuse and does not cluster into sharply defined structures, suggesting that permeability is maintained within the reservoir through distributed brittle failure. The seismic velocity structure reveals heterogeneous distributions of compressional (Vp) and shear (Vs) wave speed, with Vs generally higher in the Main Field and East Flank and Vp remaining relatively uniform across the CGF, but with significant local variations. The Vp/Vs ratio appears to outline the two main producing compartments of the reservoir at depths below mean ground level of approximately 1 to 2.5 km, with a ridge of relatively high Vp/Vs separating the Main Field from the East Flank. Detailed analyses of spatial and temporal variations in earthquake relocations and cumulative seismic moment release in the East Flank reveal three regions with persistently high rates of seismic activity. Two of these regions exhibit sharp, stationary boundaries at the margins of the East Flank that likely represent barriers to fluid flow and advective heat transport. However, seismicity and moment release in a third region at the northern end of the East Flank spread over time to form an elongated NE to SW structure, roughly parallel both to an elongated cluster of seismicity at the southern end of the East Flank and to regional fault traces mapped at the surface. Our results indicate that high-precision relocations of micro-seismicity and simultaneous velocity inversions in conjunction with mapping of seismic moment release can provide useful insights into subsurface structural features and hydrologic compartmentalization within the Coso Geothermal Field.

California↗

The Coso EGS project - Recent developments

An Enhanced Geothermal System (EGS) field experiment will be conducted to hydraulically stimulate injection well 34-9RD2, located on the east flank of the Coso geothermal reservoir, with the objective of increasing the injection rate of this well to 750 gpm at a wellhead pressure of 100 psi or less. The stimulation of this well is expected to create hydraulic communication with the recently drilled production well 38C-9, which is directly south of 34-9RD2. We summarize the results of fracture and stress analyses based upon borehole image logs of 38C-9; petrographic and petrologic analyses of cuttings from both the injection well 34-9RD2 and the production well 38C-9; and plans for the redrilling and stimulation of 34-9RD2.

California↗

The Coso EGS project - Recent developments

An Engineered Geothermal System (EGS) field experiment will be conducted to hydraulically stimulate injection well 34-9RD2, located on the east flank of the Coso geothermal reservoir, with the objective of increasing the injection rate of this well to 750 gpm at a wellhead pressure of 100 psi or less. The stimulation of this well is expected to create hydraulic communication with the recently drilled production well 38C-9, which is directly south of 34-9RD2. We summarize the results of fracture and stress analyses based upon borehole image logs of 38C-9; petrographic and petrologic analyses of cuttings from both the injection well 34-9RD2 and the production well 38C-9; and plans for the redrilling and stimulation of 34-9RD2.

California↗