Search USGS⌕ Search

Geology topics

Yu-Feng Lin

Publications and source records attributed to Yu-Feng Lin.

4 recordsLinked to original sources

A new groundwater energy transport model for the MODFLOW hydrologic simulator

Heat transport in the subsurface is an important aspect of research related to the effects of a warming climate on ecological services (i.e., cold-water refugia); the development of geothermal resources for energy banking schemes (i.e., aquifer thermal energy storage [ATES]); and the effects of temperature on other aspects of groundwater quality, such as nutrient cycling. Historically, simulation of heat transport using the MODFLOW groundwater simulator and related codes was performed by scaling the input parameters of a solute-transport model to emulate heat transport. However, that approach required additional pre- and post-processing of input and output and could not account for the variation in effective thermal storage and transport properties during transient, unsaturated flow, for example. True heat-transport capabilities in the context of MODFLOW were first introduced in a variant called USG-Transport. More recently, a new groundwater energy-transport (GWE) model type has been added to MODFLOW 6, the core version of the MODFLOW hydrologic simulator. GWE supports the simulation of heat transport on structured or unstructured grids as well as within and between features of advanced packages that represent streams, lakes, multi-aquifer wells, and the unsaturated zone. GWE is integrated within MODFLOW 6 and is accessible through the FloPy Python package and the MODFLOW 6 application programming interface (API). An example simulation demonstrates conduction between grid cells through both the water and the solid aquifer material, including thermal bleeding from saturated overburden cells into a groundwater flow field.

Groundwater↗

City-scale geothermal energy everywhere to support renewable resilience – A transcontinental cooperation

Cities have important and varying incentives to transform their energy sector to all-electric with low carbon emissions. However, they often encounter a number of impediments when attempting to implement such a change. For example, while urban areas have the highest energy demand-density, cities often lack the space for installing additional energy generation and/or long-duration energy storage systems. Cities also have existing environmental issues from energy sources (e.g., pollution from dust, waste heat or noise) that make residents sensitive to energy infrastructure development. Utilizing power from conventional sources, such as natural gas, biomass and hydropower, which usually are distanced from the urban areas, also make cities more vulnerable to supply disruptions. One promising de-carbonizing energy option for cities focuses on their heating and cooling needs, which constitutes around 1/3 of U.S. and 1/2 of European energy consumption (including industrial processes like drying, pasteurization, etc.; Jadun and others, 2017; EU Commission 2022). If heating and cooling loads can be met by geothermal direct-use technologies, then the need for new electric sources can be greatly lessened. Despite the proven efficacy of geothermal energy as a city/community-scale heating and cooling resource, it is currently only a niche resource in the heating and cooling sector, though has significant potential for future growth. Historically, emphasis has been placed on geothermal electricity generation potential that requires higher temperature (greater than 90 °C) resources at drillable depths, but potentially viable areas are geographically limited and typically well removed from urban centers. Key drivers for investments were represented by greater political interest in renewable electricity production, higher revenues and less effort in distributing the produced energy via grids. In contrast, low-temperature (less than 90 °C) geothermal resources can be used directly for heating and cooling almost everywhere and are cost-effective in urban/suburban settings. In addition, the increased prominence of renewable electricity sources, such as wind and solar onto city-scale electric grids, has led to new urgency around questions of energy storage. Underground thermal energy storage (UTES), wherein surplus or waste heat is stored underground for later use, could present a long-duration energy storage solution. From October 2022 through September 2024, a transcontinental consortium consisting of geological surveys, geoscience organizations, industry representatives and universities aims to develop an understanding of the global potential for city-scale geothermal, proposing guidelines to aid in promoting the economic utilization of low temperature geothermal resources. Efforts will focus on providing city managers and other decision makers with the information needed to evaluate and implement suitable city/community-scale geothermal technologies. Funded by the U.S. Geological Survey’s John Wesley Powell Center for Analysis and Synthesis, this interdisciplinary consortium will showcase tools, datasets, and scientific recommendations to accelerate the broader understanding and adoption of renewable energy systems that access geothermal resources. The collaborative research activities include standardization of nomenclatures, resource description and characterization strategies globally. The results from these activities will be combined with a preliminary climate-driven, city-based energy needs related analysis to perform energy supply/demand matching analysis. The identification of city-specific applications that would benefit from the geothermal technologies provides the basis to up-scale city-specific determinations to regional and national assessments of resource estimates. The city-scale geothermal energy research initiative will ultimately provide the synergies and management analysis that can address benefits, environmental impacts, regulatory frameworks, sustainability, and suitability in retrofitted buildings or new as well as existing heating networks.

Conference Paper↗

Simulation of the shallow aquifer in the vicinity of Silver Lake, Washington County, Wisconsin, using analytic elements

Shallow ground-water flow in the vicinity of Silver Lake, Washington County, Wisconsin, was investigated to develop an understanding of the hydrology of the shallow aquifer, define a water balance for the lake, delineate ground-water recharge areas for the lake, and to estimate solute flux toward the lake. A single-layer, steady-state, analytic-element model was used to simulate shallow ground-water flow. Regional model parameters include a recharge rate of 4 inches per year, hydraulic conductivity of 50 feet per day and a model base of 800 feet above sea level. A model inhomogeneity was added to represent deviations from these regional values for an area roughly coincident with the Kettle Moraine Area that trends through the study area. Model calibration was accomplished by varying the regional parameter values and those of the inhomogeneity through trial-and-error to determine a best-fit match between simulated and measured values for head and streamflow targets. There was no change to the regional parameter values as a result of calibration, however, the calibrated values for the inhomogeneity are: recharge rate of 12 inches per year, hydraulic conductivity of 20 feet per day, and a model base of 900 feet. These changes represent a four- to five-fold reduction in transmissivity within the inhomogeneity as compared to the regional model. A Silver Lake water budget was defined using both published hydrologic data and simulations using the calibrated model. Model simulations show that 1.08 cubic feet per second of ground water enters Silver Lake on the upgradient (primarily western) side and 0.08 cubic feet per second recharges to ground water on the downgradient (primarily eastern) side. Net precipitation (precipitation minus evaporation) on the lake is 0.04 cubic feet per second. Collectively, these water-budget terms provide a residual value of 1.04 cubic feet per second flow to Silver Creek at the north end of Silver Lake, which is a very good match to the range of measured flow (0.7 to 5.2 cubic feet per second). Ground-water recharge areas for Silver Lake are largely on the western side of the lake. The recharge area for the northern two-thirds of Silver Lake is west toward Big Cedar Lake. Assuming a porosity of 20 percent, model results indicate that the 50-year time-of-travel for recharge to Silver Lake does not extend to Big Cedar Lake. The recharge area for the southern one-third of Silver Lake is west toward Little Cedar Lake. Model results indicate that time of travel for recharge to Silver Lake from Little Cedar Lake is about 15 to 20 years. For travel times greater than 15 or 20 years, the ground-water recharge area for Little Cedar Lake and inflow from Big Cedar Lake also should be considered recharge affecting Silver Lake. Solute flux toward Silver Lake was calculated based on simulated ground-water flux and measured concentrations in the upgradient piezometers and observation wells.

Wisconsin↗

Simulation of Fish, Mud, and Crystal Lakes and the shallow ground-water system, Dane County, Wisconsin

A new MODFLOW lake package (LAK3) that simulates ground-water/lake interaction was used in simulation of Fish, Mud and Crystal Lakes?three shallow seepage lakes located in northwestern Dane County, Wis. The simulations were done to help determine the cause of increasing lake stages and provide a tool to estimate the effect of pumping water from Fish lake on future lake stages. The ground-water-flow model was developed using a telescopic-mesh refinement of the Dane and southwestern Columbia Counties regional model previously developed by the U.S. Geological Survey and the Wisconsin Geological and Natural History Survey. The parameter estimation model, UCODE, was coupled to the steadystate ground-water model to automate and optimize the calibration procedure. The steady-state model was calibrated to measured ground-water levels, Spring Creek streamflow measured at Lodi, and Fish and Crystal Lake stages. The results of the steady-state model were used as initial conditions in a transient simulation beginning in 1966 and ending in 1998. Recharge based on annual baseflow in Black Earth Creek, runoff based on measured coefficients, and precipitation and evaporation from the lake surfaces, were varied during the transient simulation. Measured Fish Lake stage was matched to simulated stage to calibrate the transient model. Model results suggest that the increase in regional ground-water recharge resulted in increased ground-water flow to the lake, which in turn resulted in increased lake stages. Simulation results of withdrawal of water from Fish Lake at 500 gallons per minute, assuming 1990?98 climatic conditions, indicate that after 1 year of pumping the stage of Fish and Mud Lakes would be reduced more than 1 foot and the stage of Crystal Lake would be reduced by less than 0.2 foot. When pumping is stopped, the lake stages would recover to near pre-pumping levels within about 3 years. When pumping is extended to 5 years, Fish and Mud Lake stage would be reduced by a maximum of 3.8 feet and Crystal Lake stage is reduced a maximum of 0.8 feet. After 4 years of recovery, Fish and Mud Lake stages are within 0.9 foot of prepumping levels and Crystal Lake stage is within 0.7 foot.

Wisconsin↗