Search USGSSearch

Geology topics

Yogesh C. Agrawal

Publications and source records attributed to Yogesh C. Agrawal.

2 recordsLinked to original sources

A comparison of near-bed acoustic backscatter and laser diffraction measurements of suspended sediments

As part of the U.S. Office of Naval Research (ONR, Arlington, VA) mine burial program, an experiment was conducted off the pier at Santa Cruz, CA, to measure the near-bed suspended sediment reference concentration under waves and currents. Two tripods were deployed to carry out the measurements; one consisting mainly of acoustical instrumentation and the other solely of optical instruments. The tripods were located within 15 m of one another on a sandy bed and measurements of the suspended sediment were made using acoustics and optics. Although the experiment was not primarily designed to conduct an intercomparison of acoustical and optical measurements, it was considered interesting to take advantage of the situation and to examine if these two techniques gave comparable results. In particular, measurements of particle size and concentration, obtained using a triple frequency acoustic backscatter system (ABS) have been compared with the commercially available laser miniature scattering and transmissometry instrument (MSCAT). It was found that the mean grain size estimated by the two methods was consistent; however, in contrast, the concentration time series showed differences, both in magnitude and form.

IEEE Journal of Oceanic Engineering

The LISST-SL streamlined isokinetic suspended-sediment profiler

The new manually deployed Laser In Situ Scattering Transmissometer-StreamLined profiler (LISST-SL) represents a major technological advance for suspended-sediment measurements in rivers. The LISST-SL is being designed to provide real-time data on sediment concentrations and particle-size distributions. A pressure sensor and current meter provide real-time depth and ambient velocity data, respectively. The velocity data are also used to control pumpage across an internal laser so that the intake velocity is constantly adjusted to match the ambient stream velocity. Such isokinetic withdrawal is necessary for obtaining representative sedimentary measurements in streamflow, and ensures compliance with established practices. The velocity and sediment-concentration data are used to compute fluxes for up to 32 particle-size classes at points, verticals, or in the entire stream cross section. All data are stored internally, as well as transmitted via a 2-wire conductor to the operator using a specially developed communication protocol. The LISST-SL's performance will be measured and compared to published sedimentological accuracy criteria, and a performance summary will be placed on-line.

Conference Paper