Search USGSSearch

Geology topics

William A. Pitt

Publications and source records attributed to William A. Pitt.

4 recordsLinked to original sources

Disposal of saltwater during well construction--Problems and solutions

The recent interest in the disposal of treated sewage effluent by deep-well injection into salt-water-filled aquifers has increased the need for proper disposal of salt water as more wells are drilled and tested each year. The effects on an unconfined aquifer of the improper disposal of salt water associated with the construction of three wells in southeastern Florida emphasize this need. In two of the wells provisions to prevent and detect salt-water contamination of the unconfined aquifer were practically nonexistent, and in one well extensive provisions were made. Of the three drilling sites the one with proper provision for detection presented no serious problem, as the ground water contaminated by the salt water was easily located and removed. The provisions consisted of drilling a brine-injection well to dispose of salt water discharged in drilling and testing operations, using a closed drilling circulation system to reduce spillage, installing shallow observation wells to map the extent and depth of any salt-water contamination of the shallow aquifer, and installing a dewatering system to remove contaminated ground water.

Groundwater

Ground-water quality in selected areas serviced by septic tanks, Dade County, Florida

During 1971-74, the U.S. Geological Survey investigated the chemical, physical, bacteriological, and virological characteristics of the ground water in five selected areas serviced by septic tanks in Dade County, Florida. Periodic water samples were collected from multiple-depth groups of monitor wells ranging in depth from 10 to 60 ft at each of the five areas. Analyses of ground water from base-line water-quality wells in inland areas remote from urban development indicated that the ground water is naturally high in organic nitrogen, ammonia, organic carbon and chemical oxygen demand. Some enrichment of ground water with sodium provided a possible key to differentiating septic-tank effluent from other urban ground-water contaminant sources. High ammonia nitrogen, phosphorus, and the repetitive detection of fecal coliform bacteria were characteristic of two 10-foot monitor wells that consistently indicated the presence of septic-tank effluent in ground water. Dispersion, dilution, and various chemical processes have presumably prevented accumulation of septic-tank effluent at depths greater than 20 ft, as indicated by the 65 types of water analyses used in the investigation. Fecal coliform bacteria were present on one or two occasions in many monitor wells but the highest concentration, 1,600 colonies/100 ml, was related to storm-water infiltration rather than septic-tank discharge. Areal variations in the composition and the hydraulic conductivity of the sand and limestone aquifer had the most noticeable influence on the overall ground-water quality. The ground water in the more permeable limestone in south Dade County near Homestead contained low concentrations of septic-tank related constituents, but higher concentrations of dissolved sulfate and nitrate. The ground water in north Dade County, where the aquifer is less permeable, contained the highest dissolved iron, manganese, COD, and organic carbon.

Florida

Effects of septic tank effluent on ground-water quality, Dade County, Florida: an interim report

At each of five sites in Dade County, where individual (residence) septic tanks have been in operation for at least 15 years and where septic tank concentration is less than 5 per acre, a drainfield site was selected for investigation to determine the effects of septic tank effluent on the quality of the water in the Biscayne Aquifer. At each site two sets of multiple depth wells were drilled. The upgradient wells adjacent to the drainfields in most places, were constructed in such a way that the aquifer could be sampled at 10, 20, 30, 40, and 60 feet below land surface. The down-gradient wells at each site are 35 feet or more from the up-gradient wells in the direction of ground-water flow, and allow. the aquifer to be sampled at various depths. Except at one site, no fecal coliforms were found below the 10-foot depth. Total coliforms exceeded a count of one colony per ml at the 60- foot depth at two sites. At one site a fecal streptococci count of 53 colonies per ml was found at the 60-foot depth and at another a count of seven colonies was found at the 40-foot depth. The three types of bacteria occur in higher concentration in the northern areas of the county than in the south. Bacteria concentrations were also higher where the septic tanks were more concentrated.

Florida