Search USGS⌕ Search

Geology topics

Wayne C. Boncyk

Publications and source records attributed to Wayne C. Boncyk.

2 recordsLinked to original sources

Landsat-7 Enhanced Thematic Mapper plus radiometric calibration

Landsat-7 is currently being built and tested for launch in 1998. The Enhanced Thematic Mapper Plus (ETM+) sensor for Landsat-7, a derivative of the highly successful Thematic Mapper (TM) sensors on Landsats 4 and 5, and the Landsat-7 ground system are being built to provide enhanced radiometric calibration performance. In addition, regular vicarious calibration campaigns are being planned to provide additional information for calibration of the ETM+ instrument. The primary upgrades to the instrument include the addition of two solar calibrators: the full aperture solar calibrator, a deployable diffuser, and the partial aperture solar calibrator, a passive device that allows the ETM+ to image the sun. The ground processing incorporates for the first time an off-line facility, the Image Assessment System (IAS), to perform calibration, evaluation and analysis. Within the IAS, processing capabilities include radiometric artifact characterization and correction, radiometric calibration from the multiple calibrator sources, inclusion of results from vicarious calibration and statistical trending of calibration data to improve calibration estimation. The Landsat Product Generation System, the portion of the ground system responsible for producing calibrated products, will incorporate the radiometric artifact correction algorithms and will use the calibration information generated by the IAS. This calibration information will also be supplied to ground processing systems throughout the world.

Canadian Journal of Remote Sensing↗

Landsat-4/5 Band 6 relative radiometry

Relative radiometric responses for the thematic mapper (TM) band 6 data from Landsat-4 and Landsat-5 were analyzed, and an algorithm has been developed that significantly reduces the striping in Band 6 images due to detector mismatch. The TM internal calibration system as originally designed includes a DC restore circuit, which acts as a feedback system designed to keep detector bias at a constant value. There is a strong indication that the DC restore circuitry implemented in Band 6 does not function as it had been designed to. It operates as designed only during a portion of the calibration interval and not at all during acquisition of scene data. This renders the data acquired during the calibration shutter interval period virtually useless for correction of the individual responses of the four detectors in Band 6. It was observed and statistically quantified that the relative response of each of the detectors to the band average is stable over the dynamic range and throughout the lifetime of the instrument. This allows an alternate approach to relative radiometric correction of TM Band 6 images

IEEE Transactions on Geoscience and Remote Sensing↗